Chemische Charakterisierung und Spurenanalytik
Filtern
Dokumenttyp
- Vortrag (395) (entfernen)
Sprache
- Englisch (293)
- Deutsch (99)
- Mehrsprachig (2)
- Französisch (1)
Referierte Publikation
- nein (395)
Schlagworte
- Mikroplastik (22)
- Synchrotron (19)
- Process Analytical Technology (18)
- BAMline (16)
- XRF (16)
- Online NMR Spectroscopy (15)
- TED-GC/MS (14)
- HR-CS-GFMAS (13)
- PFAS (13)
- Prozessanalytik (13)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (270)
- 1.1 Anorganische Spurenanalytik (99)
- 6 Materialchemie (92)
- 1.4 Prozessanalytik (78)
- 1.6 Anorganische Referenzmaterialien (56)
- 6.6 Physik und chemische Analytik der Polymere (46)
- 6.3 Strukturanalytik (39)
- 4 Material und Umwelt (34)
- 1.8 Umweltanalytik (28)
- 1.7 Organische Spuren- und Lebensmittelanalytik (23)
- 4.2 Material-Mikrobiom Wechselwirkungen (15)
- 1.2 Biophotonik (13)
- 1.9 Chemische und optische Sensorik (13)
- 8 Zerstörungsfreie Prüfung (12)
- 4.3 Schadstofftransfer und Umwelttechnologien (9)
- P Präsident (9)
- P.0 Präsident und andere (9)
- 4.5 Kunst- und Kulturgutanalyse (8)
- 4.1 Biologische Materialschädigung und Referenzorganismen (7)
- 1.3 Instrumentelle Analytik (6)
- 6.1 Oberflächen- und Dünnschichtanalyse (6)
- 8.6 Faseroptische Sensorik (6)
- 3 Gefahrgutumschließungen; Energiespeicher (5)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (5)
- S Qualitätsinfrastruktur (5)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (4)
- S.1 Qualität im Prüfwesen (4)
- 1.0 Abteilungsleitung und andere (3)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (3)
- 4.0 Abteilungsleitung und andere (3)
- 7 Bauwerkssicherheit (3)
- 8.0 Abteilungsleitung und andere (3)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (3)
- 9 Komponentensicherheit (3)
- 9.0 Abteilungsleitung und andere (3)
- 1.5 Proteinanalytik (2)
- 3.5 Sicherheit von Gasspeichern (2)
- 5 Werkstofftechnik (2)
- 6.2 Material- und Oberflächentechnologien (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 9.4 Integrität von Schweißverbindungen (2)
- VP Vizepräsident (2)
- VP.1 eScience (2)
- 3.2 Gefahrguttanks und Unfallmechanik (1)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.6 Glas (1)
- 7.1 Baustoffe (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
- 7.6 Korrosion und Korrosionsschutz (1)
- 9.2 Versuchsanlagen und Prüftechnik (1)
- PST Präsidiale Stabsstelle (1)
- S.0 Abteilungsleitung und andere (1)
Photophysical and mechanistic studies, the comparison of different emitter classes, and the rational design of the next generation of molecular and nanoscale reporters require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR. To improve the reliability and comparability of photoluminescence and QY measurements across laboratories, pitfalls, achievable uncertainties, and material-specific effects related to certain emitter classes must be explored. Also, suitable protocols and reference materials are needed which have been validated in interlaboratory comparisons for different wavelength regions and transparent and scattering luminophores.[1] Based on absolute and relative photoluminescence measurements of functional dyes and nanomaterials like semiconductor quantum dots and rods, spectrally shifting lanthanide upconversion nanocrystals, perovskites, and YAG:Cer converter materials, reliable methods for determining QY of transparent and scattering luminophores, nonlinear emitters, and solid luminescent nanomaterials have been developed.[2,3] Thereby, material- and method-related uncertainties of relative and absolute QY measurements and achievable uncertainties could be quantified for linear and nonlinear UV/vis/NIR/SWIR emitters and lately for also luminescent and scattering materials and solid phoshors, here in an interlaboratory comparison of three labs utilizing integrating sphere spectroscopy.[4,5] In addition, to provide simple tools for a better comparability of QY measurements, recently, a first set of UV/vis/NIR quantum yield standards has been developed and certified with complete uncertainty budgets.[6] In the following, the outcome of these studies will be presented, thereby addressing common pitfalls and providing recommendations on the performance of reliable QY measurements of linear and non-linear emitters in transparent, scattering, and solid samples.
Reversible polycondensations are polycondensations that include equilibration reactions at any stage of the process. Syntheses of Polyesters in bulk involving transesterification reactions and syntheses of polyamides in bulk involving transamidation are typical examples. In 1950, Jacobson and Stockmayer published a first theory of reversible polycondensations based on experimental studies with aliphatic polyesters.[1,2] They explained the reversibility by the reversible formation of cyclic oligomers and low molar mass polymers from an active chain end (so-called “back-biting”). The formation of cycles via end-to-end cyclization was excluded in agreement with Flory´s theory of irreversible polycondensations.[3] The reinvestigation of the Jacobson-Stockmayer experiments by the authors in combination with theoretical considerations shows that the JS theory is wrong. [4,5] It turned out that the experimental scenario is far from the reality. In real polycondensations, intermolecular equilibration is faster than “back-biting”, and end-to-end cyclization is quite normal. The revised theory of step-growth polymerization predicts that in the ideal case of 100% conversion, all reaction products are cycles, regardless, of whether the step-growth polymerization is reversible or not.
Photophysical and mechanistic studies, the comparison of different emitter classes, and the rational design of the next generation of molecular and nanoscale reporters require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR.
As part of the "Journées de Chimie Analytique, JCA Dschang 2024", this plenary scientific conference will explore how analytical electrochemistry is fundamentally changing modern chemical analysis methods. We will highlight key innovations such as wearable/handheld sensors, lab-on-a-chip, lab-on-paper, lab-on-a-glove, integrated detection systems with artificial intelligence, and point-of-care (POC) technologies. We will also address the couplings between analytical electrochemistry and various analytical techniques such as mass spectrometry (EC-MS), chromatography (EC-LC), spectroscopy [EC-spectroscopy (UV-VIS, Raman, IR, NMR)], microscopy [EC-microscopy (EM, AFM)], and capillary electrophoresis (EC-CE). These advances enable faster, more accurate, and more accessible analyses, opening new perspectives for research and practical applications in environmental science, food and agriculture, public health, and advanced materials.
Ergot alkaloids, potent mycotoxins produced by Claviceps spp., particularly Claviceps purpurea, pose significant health risks when they contaminate rye and related cereals, leading to ergotism in humans and mammals [1]. In response, the European Union has established Regulation 2023/915, setting maximum residue levels for the sum of 12 principal ergot alkaloids and other mycotoxins including fumonisins (FUM), deoxynivalenol (DON), zearalenone (ZEN), and T2/HT2 toxins in food products. Given the prevalent co-occurrence of mycotoxins, their simultaneous detection is crucial for ensuring the safety of food and feed [2, 3].
Traditionally, chromatographic techniques such as liquid chromatography coupled with (tandem) mass spectrometry (LC-MS/MS) have been employed for multiplex detection of mycotoxins [4, 5]. While effective, these methods require specialized facilities, expensive equipment, and skilled personnel. Immunoassays like ELISA and lateral flow assays offer a more accessible alternative for rapid mycotoxin detection, yet they generally lack the capability for concurrent multi-toxin screening.
This study introduces the SAFIA (Suspension Array Fluorescence Immunoassay), a particle-based immunoassay utilizing fluorescence-encoded microparticles for the simultaneous detection of multiple analytes [6, 7]. The assay's innovative advancement comes with the inclusion of ergot alkaloids, a novel addition to its existing detection capabilities for fusarium toxins and trichothecenes, thereby expanding its scope to a broader range of mycotoxins. The assay employs antibodies targeting the ergoline moiety common to all major ergot alkaloids, facilitated by a synthesized hapten mimicking the ergoline structure. This hapten was conjugated to amino-functionalized beads, and a panel of five monoclonal antibodies was evaluated for hapten recognition, binding specificity, and competitive binding efficiency.
Our findings demonstrate that all antibodies displayed similar affinities towards the hapten and lysergol (a stable and less hazardous analogue of lysergic acid used for calibration), achieving detection limits as low as 2 ppb. Cross-reactivity studies and analysis of round-robin test material indicated a significant underestimation of ergot alkaloid levels in samples. However, accurate detection of ergot alkaloids remains feasible through the application of a correction factor to the results, which compensates for this underestimation and ensures the assay's effectiveness. Despite this adjustment, the necessity for enhancements in antibody specificity to improve assay accuracy is evident. Furthermore, the inclusion of the ergot assay in a multiplexed setup for detecting FUM, DON, ZEN, and T-2 toxins showed no interference, although an unexpected inhibition among four out of five ergot antibodies was observed. This underscores the need for an improved immunogen structure to achieve optimal detection of ergot alkaloids.
In conclusion, our study presents a promising approach for the multiplexed detection of ergot alkaloids alongside other mycotoxins, highlighting the potential of SAFIA in enhancing food and feed safety through improved mycotoxin screening. Future work will focus on refining antibody specificity and assay configurations to overcome current limitations and ensure accurate, comprehensive mycotoxin detection.
Weitestgehendes Recycling vorhandener Materialien und Produkte ist ein wesentlicher Bestandteil der Kreislaufwirtschaft. Verpackungen auf Kunststoffbasis, darunter Behälter für Lebensmittel und Getränke, aber auch für die Lagerung und den Transport von Chemikalien und Gefahrgütern, werden derzeit größtenteils aus fossilen Rohstoffen hergestellt. Doch selbst für diese „kontaktempfindlichen“ Produkte besteht weiterhin das Ziel der Nachhaltigkeit durch den Einsatz von Recyclingmaterialien. Diese sehr aktuelle Diskussion findet derzeit im Rahmen der EU-Verpackungs- und Verpackungsabfallverordnung (PPWR) statt, die voraussichtlich noch in diesem Jahr abgeschlossen sein wird. Bei Verpackungen für den Transport gefährlicher Güter sind die Sicherheitseigenschaften der Behälter aus „neuen“ Materialien, einschließlich Polyethylen (PE), gut bekannt und werden im Rahmen ihrer Bauartzulassung getestet. Über ihre Gegenstücke aus Recyclingmaterialien ist jedoch weitaus weniger bekannt. Abgesehen von Materialschwächung kann der Eintrag von Rückständen in recycelte Kunststoffe zu einer Verunreinigung der Waren in der Verpackung führen.
Um diese Lücke zu schließen, haben wir Kanister aus hochdichtem PE (HDPE) aus Post-Consumer-Abfällen auf die Freisetzung von Kunststoffzusätzen und Verunreinigungen untersucht. Mithilfe eines umfassenden, nicht zielgerichteten Ansatzes mit hochauflösender Massenspektrometrie (HRMS) konnten wir je nach Art der gelagerten Chemikalie und Lagerdauer 895 verschiedene Komponenten detektieren. Die meisten Komponenten waren alleinig oder in wesentlich höherer Konzentration in recyceltem HDPE als in herkömmlichem HDPE nachzuweisen. 154 der Komponenten konnten identifiziert und auf ihre funktionale Verwendung hin analysiert werden. Interessanterweise ergab diese Analyse „Kosmetik“, „Duftstoffe“ und „Geschmacksstoffe“ als Hauptassoziationen neben bekannten und erwarteten Verwendungen im Bereich „Kunststoffe“. Dies deutete auf einen erheblichen Eintrag von Fremdverunreinigungen in das Produkt hin. Rezyklierte Kanister zeigten damit deutliche Nachteile im Vergleich zu herkömmlichen Kanistern. Eine detaillierte Bewertung der Ergebnisse im Hinblick auf die Materialsicherheit in diesem Produktsegment steht noch aus.
Therapeutic monoclonal antibodies are the fastest-growing class of biological agents and the development of reliable analytical methods for their quantification is becoming increasingly important. Liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) represents one of the leading technologies for antibody quantification. The serin protease trypsin has emerged as the gold standard enzyme for digesting intact protein into peptides for this approach. However, many protocols exist that often lead to different results. The talk will provide a brief introduction to the application of novel thermostable and surface-functionalized trypsin particles for improved antibody digestion as well as initial successes in polymer functionalization of the corundum surface to prevent nonspecific protein adsorption during the digestion procedure.
Every day, there are new headlines in the media about microplastics (1-1000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) findings all over the planet with high variations in particle number and mass. The challenges in analytics are very complex, e.g. representative sampling, non-destructive sample preparation with concentrated particles and homogeneous distribution and true detection. All together lead to lacks in harmonization and results, which are hardly comparable. On the other hand, monitoring of microplastics is mandatory in the future strictly regulated by the EU commission in the Drinking water and Wastewater Framework Directive. One step to accurate and precise results will be the development of suitable reference materials mimicking particles in the environment.
BAM developed test materials, which are produced by mixing a small portion of microplastic particles with a water-soluble matrix. After solid phase dilution and homogenisation small portions are pressed into tablets and bottled in glass vials (Figure 1). These tablets are well characterized with particle size distribution and SEM images. Additionally, they are tested as reference material candidate according to homogeneity and stability for particle number with µ-IR and µ-Raman as well as on particle mass with Py-GC/MS and TED-GC/MS after ISO Guide 35. Results are promising. The material passed the homogeneity control. No changes are observed within 6 months of storage.
The same tested reference material is finally used in sample preparation experiments, where environmental suspended particular matter from surface water or baby milk powders are spiked with the tablets.
Die Gruppe der PFAS (Per- und polyfluorierte Alkylsubstanzen) mit mehr als 10.000 Substanzen stellt ein zunehmendes Problem bei der Bewertung und Entsorgung belasteter Abfälle dar. Die zuverlässige PFAS-Analytik stellt hier aufgrund der Vielzahl an Einzelparametern mit zum Teil sehr großen Konzentrationsunterschieden eine komplexe Herausforderung dar.
Der Vortrag gibt zunächst einen Überblick über grundlegende Anforderungen an die LC-MS/MS Analytik von PFAS-Targetsubstanzen. Am Beispiel eines von BAM und SenMVKU organisierten Ringversuches 2024 zur Bestimmung von PFAS in Bodenproben (Feststoffe und Eluate) wird auf spezifische Fragestellungen zur PFAS-Analytik eingegangen.
Zur Verbesserung von Richtigkeit und Vergleichbarkeit ist die Einhaltung von Normvorgaben und die Anwendung von Qualitätssicherungsmaßnahmen unerlässlich. Hierzu gehören u.a. die Verwendung zuverlässiger Kalibrierstandards, die Kalibrierung mit definierten n-Isomeren, die Quantifizierung der Summe aus n-/br-Isomeren, der Einsatz isotopenmarkierter interner Standards für die LC-MS/MS Analyse, die Verwendung von Matrix-Referenzmaterialien sowie die Teilnahme an Ringversuchen.
Eurachem is an international network of national organisations having the objective of establishing a system for the international traceability of chemical measurements and the promotion of good quality practices. It also provides a forum for discussing common problems and exchanging information on quality assurance issues in analytical chemistry. The presentation will explain how Eurachem is organised, the requirements for participation and the opportunities for collaboration and networking. In particular, it will discuss why Eurachem offers an interesting network for young scientists to exchange experiences and further their own education.