Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2021 (42) (entfernen)
Dokumenttyp
- Vortrag (17)
- Zeitschriftenartikel (16)
- Posterpräsentation (7)
- Buchkapitel (1)
- Sonstiges (1)
Schlagworte
- HR-CS-GFMAS (9)
- ICP-MS (5)
- PFAS (5)
- Microbiologically influenced corrosion (4)
- Single cell analysis (4)
- Traceability (4)
- Archaea (3)
- Extractable organically bound fluorine (EOF) (3)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (3)
- Isotope dilution (3)
- Laser ablation (3)
- Lithium (3)
- Machine learning (3)
- Metrology (3)
- Per- and polyfluorinated alkyl substances (PFASs) (3)
- SC-ICP-ToF-MS (3)
- Soil (3)
- Uncertainty (3)
- Absolute isotope ratio (2)
- Atomic absorption spectrometry (2)
- CIC (2)
- Calibration (2)
- Cement (2)
- Copper (2)
- EOF (2)
- Finow Canal (2)
- Fluor (2)
- Human serum (2)
- ICP-ToF-MS (2)
- Isotope (2)
- Legacy pollution (2)
- Methylmercury (2)
- Nanoparticle (2)
- Sc-ICP-ToF-MS (2)
- Solid-liquid extraction (2)
- Sulfur (2)
- Triple isotope fractionation (2)
- AAS (1)
- AOF (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Algen (1)
- Algorithms (1)
- Alzheimer’s disease (1)
- Amyloid-beta (1)
- Archaeometry (1)
- Atomic Absorption Spectrometry (1)
- Battery (1)
- Bioapatite (1)
- Biodiesel fuel (1)
- Brain (1)
- Böden (1)
- CE/MC-ICP-MS (1)
- Cell (1)
- Circular economy (1)
- Cispaltin (1)
- Combustion ion chromatography (CIC) (1)
- Corophium volutator (1)
- Diagenesis (1)
- EPMA (1)
- ETV/ICP-MS (1)
- Editorial (1)
- Elemental analysis (1)
- Elementspezies & Isotope (1)
- Environmental & life science application (1)
- Environmental analysis (1)
- Flame retardants (1)
- Fluorination (1)
- Fluorine sum parameter (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- High-resolution continuum source atomic absorption spectrometer (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hot-pressing (1)
- Hydrogen (1)
- IC (1)
- ICP-MS & HR-CS-GFMAS (1)
- Imaging (1)
- Iron (1)
- Isotope dilution mass spectrometry (1)
- Isotope reference material (1)
- Isotopes (1)
- Isotopic analysis (1)
- Kopplungstechniken (1)
- LA-(MC-)ICP-MS (1)
- LA-ICP-MS (1)
- LA/ICP-MS Imaging (1)
- Laser Ablation/Imaging (1)
- Lightning talk (1)
- Lithium isotope (1)
- MALDI (1)
- Massenspektrometrie (1)
- Medicinal application (1)
- Mercury speciation (1)
- Metal toxicity (1)
- Metal uptake (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Nanomaterial (1)
- Non-target (1)
- Oberflächenwasser (1)
- Oberflächenwasser und Boden (1)
- Organically bound fluorine (1)
- Organophosphate esters (1)
- Oxygen evolution reaction (1)
- Phosphorus (1)
- Photocatalysis (1)
- Poster presentation (1)
- Programmed cell death (1)
- Provenance (1)
- Raman spectroscopy (1)
- Reference material (1)
- SC-ICP-MS (1)
- SERS (1)
- SI (1)
- Seawater (1)
- Sediment (1)
- Serum (1)
- Silicon (1)
- Solid phase extraction (SPE) (1)
- Spark plasma sintering (1)
- Special issue, young analytical scientists (1)
- Speciation Analysis (1)
- Speciation analysis (1)
- Species-specific Isotope Analysis (1)
- Sputtering (1)
- Sr isotopes (1)
- TCE (1)
- Tantalum oxyfluorides (1)
- Tau (1)
- Tetramethylammonium hydroxide (1)
- Tissue (1)
- Titanium hydride (1)
- Total element determination (1)
- Transferrin (1)
- Two-phase system (1)
- Zinc (1)
- lank characterization (1)
- tandard addition (1)
Organisationseinheit der BAM
- 1.1 Anorganische Spurenanalytik (42) (entfernen)
Eingeladener Vortrag
- nein (17)
Directing nanoparticles to the nucleus by attachment of nuclear localization sequences (NLS) is an aim in many applications. Gold nanoparticles modified with two different NLS were studied while crossing barriers of intact cells, including uptake, endosomal escape, and nuclear translocation. By imaging of the nanoparticles and by characterization of their molecular interactions with surface-enhanced Raman scattering (SERS), it is shown that nuclear translocation strongly depends on the particular incubation conditions. After an 1 h of incubation followed by a 24 h chase time, 14 nm gold particles carrying an adenoviral NLS are localized in endosomes, in the cytoplasm, and in the nucleus of fibroblast cells. In contrast, the cells display no nanoparticles in the cytoplasm or nucleus when continuously incubated with the nanoparticles for 24 h. The ultrastructural and spectroscopic data indicate different processing of NLS-functionalized particles in endosomes compared to unmodified particles. NLS functionalized nanoparticles form larger intraendosomal aggregates than unmodified gold nanoparticles. SERS spectra of cells with NLS-functionalized gold nanoparticles contain bands assigned to DNA and were clearly different from those with unmodified gold nanoparticles. The different processing in the presence of an NLS is influenced by a continuous exposure of the cells to nanoparticles and an ongoing nanoparticle uptake. This is supported by mass-spectrometry-based quantification that indicates enhanced uptake of NLS-functionalized nanoparticles compared to unmodified particles under the same conditions. The results contribute to the optimization of nanoparticle analysis in cells in a variety of applications, e.g., in theranostics, biotechnology, and bioanalytics.
Zellen, als Grundeinheit für Organismen, bilden einen wesentlichen Eckpfeiler für das Leben. Die Untersuchung von einzelnen Zellen liefert wertvolle Einblicke in fundamentale Prozesse des Lebens. So können Anomalien auf der Zelleebene Indikatoren für Krankheiten sein und durch eine Analyse früh erkannt werden. Weiterhin kann durch ein tiefgreifendes Verständnis von Vorgängen in Zellen auch gezielt Forschung zu z.B. neuen Medikamenten betrieben werden. Damit können die Wirksamkeit erhöht und die Nebenwirkungen reduziert werden.
Materials in contact with the environment release e.g., metal-ions, elemental species and/or (nano-)particles. Once these species and/or particles are released, they are ingested by organisms and cells and thus, might have a negative impact on the environment. Thus, identification as well as quantification of potentially harmful substances is of utmost importance and highly needed to assess ecotoxicological impact of (emerging) pollutants.
The oral presentation provides an overview on the power of elemental analytical techniques, in particular ICP-MS as well as HR-CS-GFMAS in environmental research. Current research topics from Division 1.1 @ BAM - Inorganic trace analysis will be highlighted:
i) Elemental Speciation & Isotope analysis - new tools:
Among elemental species separation and quantification, one of the main challenges in environmental elemental speciation analysis is the distinction between anthropogenic and natural elemental species. The on-line combination of elemental speciation and isotope analysis combines “the best from both worlds” - species specific isotopic information becomes available.
As an application example the analysis of current anti-fouling agents via CE/MCICP-MS will be highlighted.
ii) HR-CS-GFMAS for PFC analysis:
Per- and polyfluorinated compounds (PFC) are emerging contaminants in particular in soil and surface water samples. Due to the large number of compounds (>4700), target analytical methods are not sufficient and sum parameter methods for organically bound fluorine are highly needed.
High resolution-continuum source-graphite furnace molecular absorption spectroscopy (HR-CS-GFMAS) based methods for organically bound fluorine analysis will be presented. Application examples (soil and surface water) will be highlighted.
iii) Single cell-ICP-ToF-MS - ecotox. assessment:
Single cell and single organism analysis for e.g. ecotoxicological/medicinal assessment are hot topics in the research field of ICP-MS. In particular ICP-ToF-MS is a powerful, emerging techniques in terms of single cell/particle analysis.
Automated single cell/diatom-ICP-ToF-MS as a potential tool in ecotoxicological testing will be presented.
In this poster for the SCIX Conference, we apply an analytical procedure based on the monitoring of the lithium isotope through the partially resolved isotope shift in the electronic transition 22P<-22S around wavelength 670.80 nm using high-resolution continuum source atomic absorption spectrometer (HR-CS-AAS) in combination with machine learning (ML) for the determination of Li Isotope ratio analysis.
The quantification of the sulphur mass fraction in pure copper and copper alloys by GDMS and LA-ICP-MS revealed a lack of traceability mainly due to a lack of suitable certified reference materials for calibrating the instruments. Within this study GDMS and LA-ICP-MS were applied as routine analytical tools to quantify sulphur in copper samples by applying reference materials as calibrators, which were characterized for their sulphur mass fraction by IDMS beforehand. Different external calibration strategies were applied including a matrix cross type calibration. Both techniques with all calibration strategies were validated by using certified reference materials (others than those used for calibration) and good agreement with the reference values was achieved except for the matrix cross type calibration, for which the agreement was slightly worse. All measurement results were accompanied by an uncertainty statement. For GDMS, the relative expanded (k = 2) measurement uncertainty ranged from 3% to 7%, while for LA-ICP-MS it ranged from 11% to 33% when applying matrix-matched calibration in the sulphur mass fraction range between 25 mg kg-1 and 1300 mg kg-1. For cross-type calibration the relative expanded (k = 2) measurement uncertainty need to be increased to at least 12% for GDMS and to at least 54% for LA-ICP-MS to yield metrological compatibility with the reference values. The so obtained measurement results are traceable to the international system of units (SI) via IDMS reference values, which is clearly illustrated by the unbroken chain of calibrations in the metrological traceability scheme.
In many scientific fields, isotopic analysis can offer valuable information, e.g., for tracing the origin of food products, environmental contaminants, forensic and archaeological samples (provenance determination), for age determination of minerals (geochronological dating) or for elucidating chemical processes. Up to date, typically bulk analysis is aimed at measuring the isotopic composition of the entire elemental content of the sample. However, the analyte element is usually present under the form of different species. Thus, separating species of interest from one another and from matrix components prior to isotope ratio measurements can provide species-specific isotopic information, which could be used for tracing the origin of environmental pollutants and elucidation of (environmental) speciation. Using on-line hyphenations of separation techniques with multicollector-ICP-MS (MC-ICP-MS) can save time and effort and enables the analysis of different species during a single measurement.
In this work, we developed an on-line hyphenation of CE with multicollector-ICP-MS (CE/MC-ICP-MS) for isotopic analysis of sulfur species using a multiple-injection approach for instrumental mass bias correction by standard-sample bracketing. With this method, the isotopic composition of sulfur in sulfate originating from river water could be analyzed without sample preparation. The results were compared to data from off-line analysis of the same samples to ensure accuracy. The precision of the results of the on-line measurements was promising regarding the differentiation of the river systems by the isotopic signature of river water sulfate. The great potential of this method is based on the versatility of the applied separation technique, not only in the environmental field but also for, e.g., biomolecules, as sulfur is the only covalently bound constituent of proteins that can be analyzed by MC-ICP-MS.
Technologie-kritische Elemente (TCE) sind unentbehrliche Materialien für High-Tech Produkte wie Smartphones, Notebooks und Monitors. Ihr Bedarf wird voraussichtlich aufgrund des gesellschaftlichen Wandels hin zu einer grünen Ökonomie exponentiell ansteigen. Dieser Wandel wird vor allem auch durch erneuerbare Energien und Elektromobilität geprägt (European Green Deal). Diese Entwicklung in Verbindung mit einer nahezu fehlenden TCE Produktion in Europa setzt den Markt unter Druck und führt zu steigenden Preisen. Die Sicherung des TCE Nachschubs wurde in der gegenwärtigen Gesundheitskrise noch dringender und wurde daher auch zu einem der Hauptthemen des COVID-19 Recovery Plan, der eine Stärkung der europäischen Resilienz und Autonomie zum Ziel hat. Ein nachhaltige Lösung ist das Recycling der Abfall- bzw. Wertstoffe und letztendlich eine Circular Economy. Allerdings ist die Analyse von Abfallströmen schwierig und erfordert geeignete analytische Lösungen, die SI-rückführbare und somit vergleichbare Messergebnisse im gesamten Recyclingprozess ermöglichen. Die dafür erforderlichen, für TCE zertifizierte, Referenzmaterialien und nötige standardisierte Verfahren fehlen bisher nahezu vollständig. In diesem Beitrag werden die analytischen Herausforderungen, wie z.B. die extreme Heterogenität der Materialien, Schwierigkeiten beim Probenaufschluss und das Fehlen von Referenzmaterialien diskutiert. Und es wird das EMPIR-Projekt MetroCycleEU vorgestellt, dessen Ziel es ist Referenz- und Routineverfahren für ausgewählte TCE (Co, Ga, Ge, In, Ta, Nd, Pr, Dy, Gd, La, Au, Pt, Pd, Rh) zu entwickeln und Referenzmaterialien für Platinen, LEDs und Li-Batterien bereitzustellen.