Chemische Charakterisierung und Spurenanalytik
Filtern
Erscheinungsjahr
- 2021 (50) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (50)
Sprache
- Englisch (50)
Referierte Publikation
- ja (50) (entfernen)
Schlagworte
- Cancer (3)
- ICP-MS (3)
- Mass Spectroscopy (3)
- Metabolomics (3)
- Mycotoxins (3)
- Copper (2)
- Food analysis (2)
- Heart failure (2)
- Human serum (2)
- Immunoassay (2)
- Industry 4.0 (2)
- Isotope dilution (2)
- Lithium (2)
- MALDI-TOF MS (2)
- Modular Production (2)
- Quality assurance (2)
- Reference material (2)
- Sulfur (2)
- 2-propanol oxidation (1)
- AAS (1)
- AFM (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Adsorption (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Air analysis (1)
- AlCl (1)
- Alcohol electrooxidation (1)
- Algorithms (1)
- Allergy (1)
- Alzheimer’s disease (1)
- Amperometry (1)
- Amyloid-beta (1)
- Antagonists (1)
- Antibody Purification (1)
- Artificial Neural Networks (1)
- Artificial neural networks (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Automated Purification (1)
- Bawit (1)
- Bbeverages (1)
- Bioapatite (1)
- Biodiesel fuel (1)
- Biological & biomedical applications (1)
- Bisphenol-A (1)
- Blood-brain barrier (1)
- Borosilicate Glass (1)
- Borosilicate glass (1)
- Brain (1)
- CRM (1)
- Calibration (1)
- Cardiolipins (1)
- Catalysts (1)
- CdSe/ZnS quantum Dots (1)
- Cellular uptake (1)
- Cement (1)
- Certified reference material (1)
- Chemical Process Control (1)
- Chemical Safety (1)
- Chlorides (1)
- Chlorine (1)
- Citizen Science (1)
- Column holder (1)
- Combustion (1)
- Concentration step (1)
- Construction (1)
- Consumer Products (1)
- Coptic manuscripts (1)
- Corophium volutator (1)
- Crystallization (1)
- Cyber-Physical Systems (1)
- Cyber-physical systems (1)
- Cyclic voltammetry (1)
- Cycloparaphenylenes (1)
- Density functional theory (1)
- Diagenesis (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Diastolic dysfunction (1)
- Diatomic molecule (1)
- Diclofenac (1)
- Diesel exhaust (1)
- Digital Transformation (1)
- Direct alcohol fuel cells (1)
- Dispersive-XAS (1)
- Dityrosine (1)
- Down Stream Processing (1)
- EPMA (1)
- ETV (1)
- Editorial (1)
- Electrocatalysis (1)
- Electrochemical energy conversion (1)
- Electrochemical real-time mass spectrometry (1)
- Electrochemistry (1)
- Electronic nose (1)
- Elemental analysis (1)
- Emerging contaminants (1)
- Ergot alkaloids (1)
- Esterification (1)
- European Reference Material (1)
- Exhaust (1)
- Extraction (1)
- FPLC (1)
- Fast single pulse response (1)
- Filter crucible (1)
- Finow Canal (1)
- Fluorination (1)
- Food Analysis (1)
- Fusarium mycotoxin (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- Gas chromatography (1)
- Glass Support (1)
- Glucose (1)
- Graphite furnace (1)
- HERFD-XAS (1)
- HPLC (1)
- HT22 (1)
- Hay fever (1)
- HeLa (1)
- High-Speed Separations (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- High-resolution mass spectrometry (1)
- Host–guest systems (1)
- Hot-pressing (1)
- Human Plasma (1)
- Hydrazinolysis (1)
- Hydrogen (1)
- Hydrolytic resistance (1)
- Hypothalamus (1)
- ICP-OES (1)
- ISO 16000-6 (1)
- IgG determination (1)
- Imaging (1)
- Indoor air (1)
- Industry 4.0, (1)
- Ink analysis (1)
- Interlaboratory key comparison (1)
- Ionization (1)
- Iron (1)
- Isotope (1)
- Isotope dilution mass spectrometry (1)
- Isotopes (1)
- Isotopic analysis (1)
- LA-(MC-)ICP-MS (1)
- LA-ICP-MS (1)
- LA-ICP-SFMS (1)
- LA/ICP-MS Imaging (1)
- LC-MS/MS (1)
- Lactate (1)
- Laser ablation (1)
- Laser metal deposition (LMD) (1)
- Legacy pollution (1)
- Lipidomics (1)
- Lipids (1)
- Liver X receptor (1)
- MRI (1)
- Machine learning (1)
- Macrocycles (1)
- Magnetic beads (1)
- Magnetic resonance imaging (1)
- Mass Spectrometry (1)
- Mass spectrometry (1)
- Mechanism (1)
- Medicinal application (1)
- Mercury speciation (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metformin (1)
- Methylmercury (1)
- Metrology (1)
- Microbe interactions (1)
- Microdialysis (1)
- Microplastic (1)
- Mixed ink (1)
- Mobile analysis (1)
- Molecular imaging (1)
- Molecular marker (1)
- Molecular recognition (1)
- Monoclonal Antibodies (1)
- Monolith (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multivariate analysis (1)
- Nanoparticle (1)
- Near-infrared refectography (1)
- Nitrotyrosine (1)
- Nontarget analysis (1)
- Nuclear Magnetic Resonance Spectroscopy (1)
- Nuclear magnetic resonance spectroscopy (1)
- Nuclear receptor (1)
- Ochratoxin A (1)
- Open Science (1)
- Optical sensor (1)
- Outdoor odor emissions (1)
- Oxygen evolution reaction (1)
- PAHs (1)
- PLS regression (1)
- Papyrus (1)
- Photocatalysis (1)
- Plastic bottles (1)
- Polyclonal Antibodies (1)
- Polycyclic aromatic hydrocarbons (1)
- Polylactide (1)
- Priority effect (1)
- Process Analytical Technology (1)
- Process control (1)
- Programmed cell death (1)
- Prostate cancer (1)
- Protein (1)
- Protein A (1)
- Protein Purification (1)
- Provenance (1)
- Purity assessment (1)
- Quantitative bioimaging (1)
- Quick-XAS (1)
- RXES (1)
- Raman spectroscopy (1)
- Regeneration (1)
- Robustness (1)
- SAXS (1)
- SERS (1)
- SI (1)
- SOM-SM (1)
- Screening (1)
- Screening method (1)
- Seawater (1)
- Secondary alcohols (1)
- Serum (1)
- Silicon (1)
- Single cell (1)
- Sintered Material (1)
- Soda-lime glass (1)
- Solvents (1)
- Spark plasma sintering (1)
- Special issue, young analytical scientists (1)
- Spectrometry (1)
- Sputtering (1)
- Sr isotopes (1)
- Sum parameter method (1)
- Supramolecular chemistry (1)
- TD-GC-MS (1)
- TED-GC/MS (1)
- TXRF-XAS (1)
- Tantalum oxyfluorides (1)
- Tau (1)
- Tetramethylammonium hydroxide (1)
- Therapeutic Antibodies (1)
- Thermal desorption (1)
- Thermal model (1)
- Titanium hydride (1)
- Total element determination (1)
- Toys (1)
- Traceability (1)
- Transferrin (1)
- Two-phase system (1)
- Uncertainty (1)
- VOC (1)
- Vegetable edible oil (1)
- Volatile marker (1)
- Water (1)
- Water analysis (1)
- X-ray fuorescence (1)
- Zinc (1)
- lank characterization (1)
- pL-droplets (1)
- tandard addition (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (42)
- 1.1 Anorganische Spurenanalytik (14)
- 1.7 Organische Spuren- und Lebensmittelanalytik (11)
- 1.8 Umweltanalytik (9)
- 1.6 Anorganische Referenzmaterialien (8)
- 1.4 Prozessanalytik (7)
- 6 Materialchemie (7)
- 6.3 Strukturanalytik (5)
- P Präsident (4)
- P.0 Präsident und andere (4)
This study shows remarkably different features between the oxidation of secondary and primary C₃-C₅ alcohols. The oxidation of primary alcohols is controlled by the oxidative removal of blocking adsorbates, such as CO, formed after the dissociative adsorption of alcohol molecules. Conversely, secondary alcohols do not undergo dissociative adsorption and therefore their oxidation is purely controlled by the energetics of the elementary reaction steps. In this respect, a different role of ruthenium is revealed for the electrooxidation of primary and secondary alcohols on bimetallic platinum-ruthenium catalysts. Ruthenium enhances the oxidation of primary alcohols via the established bifunctional mechanism, in which the adsorption of (hydr)oxide species that are necessary to remove the blocking adsorbates is favored. In contrast, the oxidation of secondary alcohols is enhanced by the Ru-assisted stabilization of an O-bound intermediate that is involved in the potential-limiting step. This alternative pathway enables the oxidation of secondary alcohols close to the equilibrium potential.
Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are critical components of every industrial chemical process as they provide information on the concentrations of individual compounds and by-products. These processes are carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been developed to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra to train an ANN with better prediction performance and speed than state-of-theart analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a possible strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control.
Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.
The CCQM-K148.a comparison was coordinated by the BIPM on behalf of the CCQM Organic Analysis Working Group for NMIs and DIs which provide measurement services in organic analysis under the CIPM MRA. It was undertaken as a "Track A" comparison within the OAWG strategic plan. CCQM-K148.a demonstrates capabilities for assigning the mass fraction content of a solid organic compound having moderate molecular complexity, where the compound has a molar mass in the range (75 - 500) g/mol and is non-polar (pKow < −2), when present as the primary organic component in a neat organic solid and where the mass fraction content of the primary component in the material is in excess of 950 mg/g.
Participants were required to report the mass fraction of Bisphenol A present in one supplied unit of the comparison material. Participants using a mass balance method for the assignment were also required to report their assignments of the impurity components present in the material. Methods used by the seventeen participating NMIs or DIs were predominantly based on either stand-alone mass balance (summation of impurities) or qNMR approaches, or the combination of data obtained using both methods. The results obtained using thermal methods based on freezing-point depression methods were also reported by a limited number of participants. There was excellent agreement between assignments obtained using all three approaches to assign the BPA content.
The assignment of the values for the mass fraction content of BPA consistent with the KCRV was achieved by most of the comparison participants with an associated relative standard uncertainty in the assigned value in the range (0.1 - 0.5)%.
Directing nanoparticles to the nucleus by attachment of nuclear localization sequences (NLS) is an aim in many applications. Gold nanoparticles modified with two different NLS were studied while crossing barriers of intact cells, including uptake, endosomal escape, and nuclear translocation. By imaging of the nanoparticles and by characterization of their molecular interactions with surface-enhanced Raman scattering (SERS), it is shown that nuclear translocation strongly depends on the particular incubation conditions. After an 1 h of incubation followed by a 24 h chase time, 14 nm gold particles carrying an adenoviral NLS are localized in endosomes, in the cytoplasm, and in the nucleus of fibroblast cells. In contrast, the cells display no nanoparticles in the cytoplasm or nucleus when continuously incubated with the nanoparticles for 24 h. The ultrastructural and spectroscopic data indicate different processing of NLS-functionalized particles in endosomes compared to unmodified particles. NLS functionalized nanoparticles form larger intraendosomal aggregates than unmodified gold nanoparticles. SERS spectra of cells with NLS-functionalized gold nanoparticles contain bands assigned to DNA and were clearly different from those with unmodified gold nanoparticles. The different processing in the presence of an NLS is influenced by a continuous exposure of the cells to nanoparticles and an ongoing nanoparticle uptake. This is supported by mass-spectrometry-based quantification that indicates enhanced uptake of NLS-functionalized nanoparticles compared to unmodified particles under the same conditions. The results contribute to the optimization of nanoparticle analysis in cells in a variety of applications, e.g., in theranostics, biotechnology, and bioanalytics.
The ubiquitous Fusarium genus is responsible for the spoilage of vast amounts of cereals and fruits.
Besides the economic damage, the danger to human and animal health by the concomitant exposure to mycotoxins represents a serious problem. A large number of Fusarium species produce a variety of different mycotoxins of which the class of trichothecenes are of particular importance due to their toxicity.
Being identified as the common volatile precursor during the biosynthesis of trichothecenes, (−)-trichodiene (TD) is considered to be a biomarker for the respective mycotoxin content in food samples. We postulated that the development of a non-invasive, on-site GC-IMS method for the quantification of (−)-trichodiene supplemented with a stationary SIDA headspace GC-MS reference method would allow circumventing the laborious and expensive analyses of individual trichothecenes in large cereal samples.
In this work we present the syntheses of the required native calibration standard and an isotope labeled (TD-D3) internal standard.
Abstract Alternariol (AOH) and alternariol-9-monomethyl ether (AME) are two secondary metabolites of Alternaria fungi which can be found in various foodstuff like tomatoes, nuts, and grains. Due to their toxicity and potential mutagenic activity the need for the development of high-throughput methods for the supervision of AOH- and AME-levels is of increasing interest. As the availability of both native and labeled AOH and AME analytical standards is very limited we herein wish to present a novel concise approach towards their synthesis employing a ruthenium-catalyzed ortho-arylation as the key step. Finally, we demonstrate their suitability as internal standards in stable-isotope dilution assay (SIDA)-HPLC-MS/MS analysis commonly used for the quantification of the natural products in food and feed.
Polycyclic aromatic hydrocarbons (PAHs) are a large group of priority organic pollutants, which contaminate environmental compartments, food, and consumer products as well. Due to their frequent occurrence associated with elevated Levels of PAHs, plastic and rubber parts of consumer products and toys are particular sources of exposure. Although European maximum levels exist for eight carcinogenic PAHs in consumer products and toys according to REACH Regulation (EC) No. 1907/2006, certified reference materials (CRM) are still not available. To overcome this lack, the first CRM for the determination of PAHs in rubber toys (BAM-B001) was developed according to the requirements of ISO Guide 35. The whole process of CRM development including preparation, homogeneity and stability studies, and value assignment is presented.
The assignment of the certified mass fractions was based upon in-house study at BAM using stable isotope Dilution analysis (SIDA) gas chromatography mass spectrometry (GC–MS). The obtained values were confirmed by the results of two interlaboratory comparison (ILC) studies with more than 50 expert laboratories from Germany and China. The mass fractions of 14 PAHs including all REACH and GS mark regulated compounds were certified ranging between 0.2 and 15.4 mg/
kg accompanied by expanded uncertainties (coverage factor k = 2). In addition, informative values were determined for 4 PAHs, mainly due to higher uncertainties and/or lack of ILC data for confirmation. BAM-B001 is intended for analytical quality control particularly based on the AfPS GS 2019:01 PAK method and contributes to improve the chemical safety of consumer products including toys.
Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are valuable analytical and quality control methods for most industrial chemical processes as they provide information on the concentrations of individual compounds and by-products. These processes are traditionally carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been realized to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra, to train an ANN with better prediction performance and speed than state-of-the-art analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control.
Stir bar sorptive extraction (SBSE) was compared with standardized pump sampling regarding the prospects to assess airborne levels of polycyclic aromatic hydrocarbons (PAHs) in indoor environments. A historic railway water tower, which will be preserved as a technical monument for museum purposes, was sampled with both approaches because the built-in insulationmaterial was suspected to release PAHs to the indoor air. The 16 PAHs on the US EPA list were quantified using gas chromatography with mass spectrometric detection in filters from pump sampling after solvent extraction and on SBSE devices after thermal desorption. SBSEwas seen to sample detectable PAHmasseswith excellent repeatability and a congener pattern largely similar to that observed with pump sampling. Congener patterns were however significantly different from that in the PAH source because release from the insulation material is largely triggered by the respective congener vapor pressures. Absolute masses in the ng range sampled by SBSE corresponded to airborne concentrations in the ng L−1 range determined by pump sampling. Principle differences between SBSE and pump sampling as well as prospects of SBSE as cost-effective and versatile complement of pump sampling are discussed.