Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (1456)
- Zeitschriftenartikel (1264)
- Posterpräsentation (524)
- Beitrag zu einem Tagungsband (267)
- Sonstiges (64)
- Forschungsdatensatz (56)
- Forschungsbericht (36)
- Buchkapitel (33)
- Dissertation (20)
- Beitrag zu einem Sammelband (17)
Sprache
- Englisch (3093)
- Deutsch (657)
- Mehrsprachig (10)
- Spanisch (5)
- Russisch (4)
- Französisch (2)
- Italienisch (1)
- Polnisch (1)
Schlagworte
- Nanoparticles (120)
- Fluorescence (116)
- LIBS (102)
- Concrete (91)
- Quantum yield (80)
- Ultrasound (76)
- Mechanochemistry (74)
- NDT (71)
- Non-destructive testing (70)
- SAXS (70)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1237)
- 8 Zerstörungsfreie Prüfung (1118)
- 6 Materialchemie (1086)
- 6.1 Oberflächen- und Dünnschichtanalyse (368)
- 6.3 Strukturanalytik (346)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (326)
- 1.1 Anorganische Spurenanalytik (306)
- 8.4 Akustische und elektromagnetische Verfahren (259)
- 4 Material und Umwelt (234)
- 1.2 Biophotonik (226)
Paper des Monats
- ja (27)
While today, engineers can choose from a wide range of rheology modifying admixtures, in some parts of the world, these are difficult to access, due to their complex processing. However, alternatives can be bio‐based polymers such as polysaccharides from various sources. These are easily accessible all over the world, do not demand for complicated processing, and typically they are more sustainable than many established materials, which are crude oil‐based.
The paper presents the effects of acacia gum, cassava starch and the gum of triumfetta pendrata A. Rich on the rheological performance of cementitious systems. It is shown that acacia gum can be as efficient as polycarboxylate based superplasticisers, cassava starch can reduce the yield stress slightly with little effect on the plastic viscosity, and the gum of triumfet ta pendrata A. Rich increases the thixotropy of cement pastes with plasticizing polymers significantly.
Structural design and application have always been linked to the compressive strength of concrete as the main relevant criterion. This was justifiable in the past, where concrete consisted of water, ordinary Portland cement and aggregates, but this concept is no longer relevant for modern and more sustainable cement and concrete.
Despite these new developments, existing standards, guidelines and academic curricula have not been much updated and are still used worldwide. There is a need to change this situation by proper education of the users.
This overview describes the challenges that arise at a user Level from the higher complexity of modern concrete, and defines needs and requirements for enhanced applicability of sustainable concrete concepts.
Furthermore, recommendations are given on how better concrete practice can be communicated to all the involved parties, from civil and design engineers to constructors and site-appliers on the construction site.
Auf dem Weg zu Industrie 4.0: Bestimmung von Messunsicherheitsbudgets in der Oberflächentechnik
(2019)
Vorgestellt wurde die Bestimmung von Messunsicherheitsbudgets für sehr unterschiedliche physikalische Größen, die in der Oberflächentechnik von hoher Relevanz sind: Stufenhöhe h, Schichtdicke d, Eindringhärte HIT und Haftfestigkeit. Die Unterschiede betreffen die Art der Prüfmethodik (optisch zerstörungsfrei vs. mechanisch invasiv/zerstörend), die laterale Größe des Integrationsgebietes der Messung (lokal: nano bis sub-mikro vs. global: mikro bis makro) und die Art der Bestimmung von Messunsicherheitsbudgets (physikalische Größen: direkt rückführbar; Werkstoffkenngröße: genormt; Systemkenngröße: genormt).
Im Rahmen von Industrie 4.0 werden ausgehend der geforderten Spezifikation des beschichteten Produkts (Mittelwert mit Vertrauensbereich oder Mindestwert) durchgehende Toleranzbänder zur Oberflächenmodifizierung/Beschichtung des Substrats, einhergehend mit Prozessfenstern, die diese Toleranzbänder garantieren, erforderlich, die zuverlässig erfasst werden müssen. Die Frage der anzuwendenden Mess- und Prüftechnik und die damit notwendige Betrachtung von Messunsicherheitsbudgets ist für die Digitalisierung von Konditionierungs-, Zustands-, Regel- und Steuergrößen unverzichtbar. Mit Blick auf die Einhaltung von Prozessfenstern und die dafür notwendige Prozessführung wird technologisches Kern-Know-how digitalisiert, das es unbedingt zu schützen gilt. Nur lokale Netze können diese Sicherheit garantieren, in globalen Netzen ist die Datensicherheit bestenfalls maximierbar
Fresh cement paste is a suspension consisting of a hydraulic binder (cement), water, and numerous minor components – admixtures. Addition of admixtures aims at specific modification of properties of the fresh cement paste or hardened cementitious building material. Specific admixtures, so-called superplasticizers (SP), are used to improve the flowability of the fresh cement paste with reduced water content. The latter is the starting material for the high-strength concrete. Thus, SPs are essential for the ambitious construction projects.
However, uncontrollable retardation of the setting time in presence of SPs is occasionally observed. Obviously, SPs influence early products of the cement hydration leading to changes in the microstructure development. The hardening is thus delayed, and the quality of the resulting building material suffers. The mechanisms of the admixture action during the hydration process are still intensively investigated [1-7]. A detailed understanding of the admixture effects during the early hydration stage is the key to control and individual adjustment of the cement-based construction materials.
We use the unique combination of the wall-free sample holder and the time-resolved X-ray scattering analysis to achieve the full information about the hydrate phases formed under the influence of admixtures. We use ultrasonic levitator to start the cement hydration in levitated cement pellets [8, 9]. The sample levitation allows collection of the unimpaired information about cement hydrate phases. The most beneficial is the avoiding of the contributions of the sample holder material to the data signal.
We induce the cement hydration by adding water to unhydrated Portland cement during the data acquisition. The full phase composition of the hydrating cementitious system can be gathered in situ using wide angle X-ray scattering (WAXS). During the hydration of cement both crystalline and amorphous hydrate phases are formed. WAXS data contain the information about crystalline phases behind the Bragg reflections, whereas the amorphous hydrates influence the appearance of the background. Application of the data analysis specific for crystalline or amorphous phases is needed. The data quantification by the Rietveld method allows to conclude about the changes of the phase amounts due to the presence of admixture. The calculation of the pair distribution functions allows analysis of the amorphous hydrates. Based on this information, the SP effects and the extent of their involvement into the ongoing reactions can be concluded. A detailed understanding of the complex cement hydration process is envisioned.
Due to its advantages of being a direct comparison method, quantitative NMR spectroscopy (qNMR) becomes more and more popular in industry. While conventional high-field NMR systems are often associated with high investment and operational costs, the upcoming market of permanent-magnet based benchtop NMR systems show a considerable option for a lot of applications. The mobility of these systems allows to bring them more closely to the real production environment, e.g. for at-line quality control.
In this work we present an interlaboratory comparison study investigating the qNMR performance of state-of-the-art benchtop NMR spectrometers. Therefore, BAM prepared two samples of a mixture of NMR reference standards tetramethylbenzene (TMB) and tetrachloronitrobenzene (TCNB) at concentration levels of 200 mM and 10 mM. These “ready-to-use” samples were sent to participant laboratories, which performed analysis on their benchtop NMR equipment of different vendors and fields from 43 to 80 MHz. Raw data was reported back and further investigated by using different data analysis methods at BAM.
After this very first qNMR comparison study of benchtop NMR spectrometers show promising results, following studies are planned to cover more parts of the qNMR process, e.g. sample preparation and weighing, but also data analysis, as commonly done in similar studies for high-field NMR spectroscopy in industry and metrology.
Die NMR-Spektroskopie stellt heutzutage eine der wichtigsten Analysenmethoden in der organischen Chemie dar. Während der Großteil aller Untersuchungen qualitativ mit dem Ziel der Stoffidentifikation und Strukturaufklärung erfolgt, erlangt die quantitative NMR-Spektroskopie (qNMR) zunehmend an Bedeutung in Forschung und Industrie. Der entscheidende Vorteil gegenüber anderen Analysenmethoden liegt in der direkten Proportionalität der Signalfläche zur Anzahl Kernspins im Messvolumen. Dies erlaubt eine kalibrationsfreie Relativquantifizierung. Zur Absolutquantifizierung reicht die Zugabe einer definierten Menge eines vom Analyten unabhängigen NMR-Standards aus.
Trotz dieser Vorteile findet sich die qNMR bislang nur vereinzelt in Normen und Standardverfahren wieder. Zahlreiche Ringversuche in Metrologie und Industrie demonstrieren die Leistungsfähigkeit moderner NMR-Spektrometer und stärken das Vertrauen in die Methode. Die Entwicklung von Validierungskonzepten, sowie die kommerzielle Verfügbarkeit geeigneter zertifizierter Referenzmaterialien erleichtern die Anwendung, insbesondere im zumeist stark regulierten industriellen Umfeld.
Neben etablierten Hochfeld-NMR Spektrometern hat sich in den letzten Jahren ein stark wachsender Markt für kompakte Benchtop-NMR Geräte auf Permanentmagnetbasis entwickelt. Die geringeren Anschaffungs- und Betriebskosten, sowie die einfache Bedienbarkeit erlaubt es auch kleineren Unternehmen in diese Analysenmethode einzusteigen. Weiterhin besteht die Möglichkeit diese mobilen Systeme näher an die Produktion zu bringen, welches von der klassischen Qualitätskontrolle bis hin zur Online-Prozesskontrolle als vollautomatisierter Analysator reicht. Die geringere Feldstärke der Systeme erfordert hier oft den Einsatz modellbasierter Ansätze zur Spektrenauswertung (z.B. Indirect Hard Modeling).
Dieser Beitrag gibt eine Übersicht über aktuelle Anwendungen und Entwicklungen der qNMR von der universellen, hochgenauen Labormethode bis hin zur robusten Anwendung als Online-Analysator im Feld.
X-ray absorption fine structure (XAFS) spectroscopy is a powerful and widely used tool for material characterization. It is non-destructive, element-sensitive and requires no long-range order of the sample, making it suitable for the investigation of amorphous phases. XAFS includes the X-ray absorption near edge structure (XANES) and the extended X-ray absorption fine structure (EXAFS), providing information about the electronical state of the absorbing atom and the spatial order of the neighboring atoms respectively.
Our new approach presented here is derived from the classical dispersive XAFS setup. The aim is to have a scanningless, stable and reproducible setup for applications, in which dynamic processes occur in the second time scale.
A broad polychromatic beam passes through the sample and is dispersed afterwards by a convexly bent Si (111) crystal. All energies are reflected under different angles and thus spatially separated, allowing a position sensitive detector to record a spectrum over the energy range of the incoming beam in a single shot.
Tests of this setup were performed at the BAMline @ BESSY-II (Berlin, Germany) with different metal foils. First in situ measurements comprised the investigation of the early stages of the zinc(II)2-methylimidazolate (ZIF-8) crystallization. This topic of metal-organic-frameworks (MOF) research is of interest for medical applications. Structural changes with a time resolution of 1 s could be followed. The second dimension of the broad beam can be used for a lateral resolution.
In der Prozessindustrie findet die optische Spektroskopie (z. B. NIR- und Raman-Spektroskopie) als Online-Analytik zunehmend Anwendung zur Überwachung che-mischer Qualitäts¬attribute in der Produktion. Ihr ganzes Potential entfalten die Methoden aber meist nur in Kombination mit einer aufwendigen, multivariaten Kalibrierung. Diese muss alle relevanten Zustände des Systems abdecken und bedarf einer geeigneten Referenz¬analytik. Moderne instrumentelle Analysengeräte weisen eine hohe Empfind¬lich¬keit und Robustheit auf, sind aber dennoch stark von Fehler und Variabilität der Probennahme beeinflusst, was sich auf die Richtigkeit und Qualität des multivariaten Modells auswirkt.
Diese Probleme lassen sich verringern, indem die Referenzanalytik ebenfalls online erfolgt. Eine mögliche Lösung stellt die hochauflösende NMR-Spektroskopie als quanti¬tative Online-Referenzanalytik dar. Insbesondere kom¬pakte NMR-Spektrometer auf Basis von Permanent¬magneten sind für diesen Zweck geeignet. Ausschlusskriterien für herkömmlicher NMR-Systeme, wie der große Wartungs-aufwand (Kryotechnik) und der Platz¬bedarf, werden damit vermieden.
Im Rahmen des EU-Projekts CONSENS wurde die Nutzung einer Online-Referenz¬analytik mit NMR-Spektroskopie am Beispiel einer industriellen Pilotanlage erfolgreich realisiert. Untersuchungsgegenstand war die kontinuierliche Synthese eines Aus¬gangsstoffs für die pharmazeutische Industrie. Die enthaltenen metallorganischen Verbindungen sind für die bisher genutzte HPLC Analytik unzu-gänglich und die Analyse ausgewählter Proben erfolgte nach dem Quenchen der Lösung oft mit einem großen zeitlichen Abstand zur Probennahme. Konzen-trationswerte auf Basis von Online-NMR-Spektren standen hingegen mit einer zeitlichen Auflösung von drei Spektren pro Minute über den gesamten Reaktionsverlauf hinweg zur Verfügung. Außerdem konnten durch die NMR-Spektroskopie intermediär auftretende Spezies erstmal quantitativ bestimmt und diese Daten für die Kalibrierung eines NIR-Spektrometers genutzt werden.
Working towards a comprehensive understanding of introduction pathways, number, and fate of micro¬plastics in the environment, suitable analytical methods are a precondition. Micro-spectroscopic methods are probably the most widely used techniques. Besides their ability to measure single spectra of a particle or fiber, most modern FTIR- and Raman microscopes are also capable of two-dimensional imaging. This is very appealing to microplastics research because it allows to simultaneously characterize the analytes chemically as well as their size (distribution) and shape.
Two-dimensional imaging on extensive sample areas with FTIR-micros¬copes is facilitated by focal plane array (FPA) detectors resulting in large data sets comprised of up to several million spectra. With numbers too large for manual inspection of each individual spectrum, automated data evaluation is inevitable. Identifying different polymers based on the comparison with known reference spectra (library search) has proven to be a suitable approach. For that purpose, FTIR-spectra of common plastics can be collected to create an individual reference library.
To Supplement this ‘targeted analysis’, looking for known substances via library search, an exploratory approach was tested. Principal component analysis (PCA) proved to be a helpful tool to drastically reduce the size of the data set while maintaining the significant information. Subsequently, cluster analysis was used to find groups of similar spectra. Spectra found in different clusters could be assigned to different polymer types. The variation observed within clusters gives a hint on chemical variability of microplastics of the same polymer found in the sample. Spectra labeled according to the respective cluster/polymer type were used to build a classification model which allowed to quickly predict the polymer type based on the FTIR spectrum. Classification was tested on a second, independent data set and results were compared to the spectral library search procedure.
Ziel des Projektes HARFE (Haftfestigkeit Reproduzierbarkeit Festigkeit) war es, eine Er-höhung der Haft- bzw. Klebfestigkeit auf Niedrigenergie-Polymeren (PE, PP, PTFE) zu erreichen. SENTECH realisierte dazu plasmachemische Oberflächenaktivierungen mit O2 und die Abscheidung von Aluminiumoxidschichten (Al2O3) mittels Atomic Layer Deposition (ALD), wobei die Ellipsometrie zum in-situ Monitoring der ALD-Prozesse diente. Die BAM charakterisierte die modifizierten Oberflächen bezüglich der Oberflächenenergie (OFE) und bestimmte die Verbund- bzw. Klebfestigkeit mittels der Zentrifugentechnologie
Ziel des Projektes HARFE (Haftfestigkeit Reproduzierbarkeit Festigkeit) war es, eine Er-höhung der Haft- bzw. Klebfestigkeit auf Niedrigenergie-Polymeren (PE, PP, PTFE) zu erreichen. SENTECH realisierte dazu plasmachemische Oberflächenaktivierungen mit O2 und die Abscheidung von Aluminiumoxidschichten (Al2O3) mittels Atomic Layer Deposition (ALD), wobei die Ellipsometrie zum in-situ Monitoring der ALD-Prozesse diente. Die BAM charakterisierte die modifizierten Oberflächen bezüglich der Oberflächenenergie (OFE) und bestimmte die Verbund- bzw. Klebfestigkeit mittels der Zentrifugentechnologie
Um in einem veränderten Umfeld erfolgreich bestehen zu können, müssen Chemie-unternehmen neue Pfade beschreiten. Dazu gehört insbesondere das Potential digi-taler Technologien. Mit flexiblen, modularen chemischen Vielzweck-Produktionsanlagen lassen sich häufig wechselnde Produkte mit kürzeren Vorlauf- und Stillstandzeiten zwischen den Kampagnen und dennoch hoher Qualität realisie-ren. Intensivierte, kontinuierliche Produktionsanlagen erlauben auch den Umgang mit schwierig zu handhabenden Substanzen.
Grundvoraussetzung für solche Konzepte ist eine hochautomatisierte "chemische" Prozesskontrolle zusammen mit Echtzeit-Qualitätskotrolle, die "chemische" Informati-onen über den Prozess bereitstellt. In einem Anwendungsbeispiel wurde eine phar-mazeutische Lithiierungsreaktion aus einer modularen Pilot-Anlage betrachtet und dabei die Vorzüge eines vollautomatischen NMR-Sensors untersucht. Dazu wurde ein kommerziell erhältliches Benchtop-NMR-Spektrometer mit Permanentmagnet auf die industriellen Anforderungen, wie Explosionsschutz, Feldkommunikation und voll-automatischer, robuster Datenauswertung angepasst. Der NMR-Sensor konnte schließlich erfolgreich im vollautomatischen Betrieb nach fortschrittlichen Regelkon-zepten und für die Echtzeitoptimierung der Anlage getestet werden. Die NMR-Spektroskopie erwies sich als hervorragende Online-Methode und konnte zusammen mit einer modularen Datenauswertung sehr flexibel genutzt werden. Die Methode konnte überdies als zuverlässige Referenzmethode zur Kalibrierung konventioneller Online-Analytik eingesetzt werden.
Zukünftig werden voll integrierte und intelligent vernetzte "smarte" Sensoren und Pro-zesse eine kontinuierliche Produktion von Chemikalien und Pharmazeutika mit ver-tretbaren Qualitätskosten möglich machen.
Visualisierung von mikro- und nanoskalierten Oberflächenstrukturen mittels abbildender Ellipsometrie
(2019)
In den letzten Jahren hat die Einbindung der abbildenden Ellipsometrie in die Gruppe der optischen Verfahren zur Oberflächencharakterisierung ein enormes Potential bei der Analyse von topologischen Strukturänderungen gezeigt. Der dabei abgebildete Kon-trast wurde typischerweise auf Änderungen im Brechungsindex, Absorptionseffekte oder Schichtdickenänderungen zurückgeführt. In späteren Studien wurde festgestellt, dass auch andere Faktoren, wie etwa die Krümmung der Oberfläche oder Kanten von Struktu-ren einen signifikanten Einfluss auf die Messung der ellipsometrischen Paramater haben. Um diese Effekte aus der ellipsometrischen Messung extrahieren zu können, wird auf die Analyse der Müller-Matrix zurückgegriffen.
In dem hier vorliegenden Beitrag wird gezeigt, wie die Müller-Matrix-Imaging Ellipsomet-rie (MM-IE) zur Charakterisierung von Oberflächenstrukturen verwendet werden kann. Dazu werden mikro- und nanoskaliert gekrümmte Oberflächen zunächst mit verschiede-nen Referenzmethoden, wie Rasterelektronenmikroskopie (SEM), Lichtmikroskopie (OM), Weißlichtinterferenzmikroskopie (WLIM) und Rasterkraftmikroskopie (AFM) vali-diert erfasst. Der anschließende Vergleich mit den Ergebnissen der Müller-Matrix-Ima-ging-Ellipsometrie ermöglicht eine Korrelation der zugrunde liegenden Strukturphäno-mene mit den ellipsometrischen Daten. In diesem Artikel wird das Prinzip an drei industriell relevanten Strukturgruppen demonstriert: Sub-Mikropartikel, Mikropartikel und sub-mikroskalierte Vertiefungen.
Visualisierung von mikro- und nanoskalierten Oberflächenstrukturen mittels abbildender Ellipsometry
(2019)
In den letzten Jahren hat die Einbindung der abbildenden Ellipsometrie in die Gruppe der optischen Verfahren zur Oberflächencharakterisierung ein enormes Potential bei der Analyse von topologischen Strukturänderungen gezeigt. Der dabei abgebildete Kon-trast wurde typischerweise auf Änderungen im Brechungsindex, Absorptionseffekte oder Schichtdickenänderungen zurückgeführt. In späteren Studien wurde festgestellt, dass auch andere Faktoren, wie etwa die Krümmung der Oberfläche oder Kanten von Struktu-ren einen signifikanten Einfluss auf die Messung der ellipsometrischen Paramater haben. Um diese Effekte aus der ellipsometrischen Messung extrahieren zu können, wird auf die Analyse der Müller-Matrix zurückgegriffen.
In dem hier vorliegenden Beitrag wird gezeigt, wie die Müller-Matrix-Imaging Ellipsomet-rie (MM-IE) zur Charakterisierung von Oberflächenstrukturen verwendet werden kann. Dazu werden mikro- und nanoskaliert gekrümmte Oberflächen zunächst mit verschiede-nen Referenzmethoden, wie Rasterelektronenmikroskopie (SEM), Lichtmikroskopie (OM), Weißlichtinterferenzmikroskopie (WLIM) und Rasterkraftmikroskopie (AFM) vali-diert erfasst. Der anschließende Vergleich mit den Ergebnissen der Müller-Matrix-Ima-ging-Ellipsometrie ermöglicht eine Korrelation der zugrunde liegenden Strukturphäno-mene mit den ellipsometrischen Daten. In diesem Artikel wird das Prinzip an drei industriell relevanten Strukturgruppen demonstriert: Sub-Mikropartikel, Mikropartikel und sub-mikroskalierte Vertiefungen.
The DNA origami technique has great potential for the development of brighter and more sensitive reporters for fluorescence based detection schemes such as a microbead-based assay in diagnostic applications. The nanostructures can be programmed to include multiple dye molecules to enhance the measured signal as well as multiple probe strands to increase the binding strength of the target oligonucleotide to these nanostructures. Here we present a proof-of-concept study to quantify short oligonucleotides by developing a novel DNA origami based reporter system, combined with planar microbead assays. Analysis of the assays using the VideoScan digital imaging platform showed DNA origami to be a more suitable reporter candidate for quantification of the target oligonucleotides at lower concentrations than a conventional reporter that consists of one dye molecule attached to a single stranded DNA. Efforts have been made to conduct multiplexed analysis of different targets as well as to enhance fluorescence signals obtained from the reporters. We therefore believe that the quantification of short oligonucleotides that exist in low copy numbers is achieved in a better way with the DNA origami nanostructures as reporters.
Increasing numbers of implant revisions are a current clinical issue. Interactions of the endoprosthesis biomaterial with the body affect implantation time by wear processes, i.e. corrosion and abrasion. Previously, cobalt-chrome implants were shown to cause high levels of cobalt ions being deposited in the bone matrix. To determine a poten- tial functional role of these ions on bone homeostasis, we have developed a non-destructive dual analysis of highly sensitive elemental analysis by synchrotron XRF directly in undecalcified histological bone thin sections (4 μm). In this study, samples from 28 bone samples from hip endoprosthesis carriers (Surface Replacement Arthroplasty, metal-on-metal bearing) with an implant lifetime of 17–1750 days were used. Results were compared to age- matched control specimens. The histological analysis identified areas of bone cell activity and assigned them for XRF measurements. Co-Cr wear particles were identified in the bone marrow. In addition, Co ions were highly enriched in the mineralized bone matrix. The cobalt deposits were not homogeneously distributed, and areas of high signal intensity were identified. Co was distinctly deposited in the newly formed osteoid layer, but also within deeper layers of the bone matrix, whereby the Co concentration increased with higher degrees of bone matrix mineralization. In the current study, we determined cobalt accumulations in the bone matrix and showed for the first time via synchrotron XRF with a high spatial resolution direct on histological slides, that cobalt deposits in the mineralized bone matrix in a mineral-specific way that is dependent upon the implant lifetime.
Dieses erste Memorandum zur Lehre und Forschung an deutschsprachigen Hochschulen auf dem Gebiet der zerstörungsfreien Prüfung im Bauwesen gibt einen Überblick hinsichtlich der akademischen Ausbildung und zeigt mögliche Schwerpunkte vor allem in der Lehre auf. Diese Schwerpunkte berücksichtigen auch aktuelle Entwicklungen und Themen auf dem Gebiet der Forschung. Es werden Anregungen zur Entwicklung bzw. Weiterentwicklung der Lehr-Curricula im Hinblick auf eine umfassende und solide fachliche Ausbildung der Studierenden des Bauwesens und angrenzender Fachrichtungen gegeben. Inhaltlich und formal lehnt sich der Beitrag an dem Memorandum der Hochschullehrer im Fachgebiet „Werkstoffe im Bauwesen“ (Breit et al., 2012) an und beruht auf einer Initiative des Unterausschusses Ausbildung – Arbeitsgruppe Ausbildung in der Hochschule – des Fachausschusses ZfP im Bauwesen der Deutschen Gesellschaft für zerstörungsfreie Prüfung (DGZfP). Die Hauptredaktion wurde übernommen von Prof. Christian U. Grosse (TU München) und Prof. Ralf W. Arndt (FH Erfurt).
We show that complex physical and chemical interactions between boehmite nanoparticles and epoxy drastically affect matrix properties, which in the future will provide tuning of material properties for further optimization in applications from automotive to aerospace. We utilize intermodulation atomic force microscopy (ImAFM) for probing local stiffness of both particles and polymer matrix. Stiff particles are expected to increase total stiffness of nanocomposites and the stiffness of polymer should remain unchanged. However, ImAFM revealed that stiffness of matrix in epoxy/boehmite nanocomposite is significantly higher than unfilled epoxy. The stiffening effect of the boehmite on epoxy also depends on the particle concentration. To understand the mechanism behind property alteration induced by boehmite nanoparticles, network architecture is investigated using dynamic mechanical thermal analysis (DMTA). It was revealed that although with 15 wt% boehmite nanoparticles the modulus at glassy state increases, crosslinking density of epoxy for this composition is drastically low.
Carrier gas hot extraction (CGHE) is a commonly applied technique for determination of hydrogen in weld joints using a thermal conductivity detector (TCD) for hydrogen measurement. The CGHE is based on the accelerated hydrogen effusion due to thermal activation at elevated temperatures. The ISO 3690 standard suggests different specimen geometries as well as necessary minimum extraction time vs. temperature. They have the biggest influence on precise hydrogen determination. The present study summarizes the results and experience of numerous test runs with different specimen temperatures, geometries (ISO 3690 type B and small cylindrical samples), and factors that additionally influence hydrogen determination. They are namely specimen surface (polished/as-welded), limited TCD sensitivity vs. specimen volume, temperature measurement vs. effects of PI-furnace controller, as well as errors due to insufficient data assessment. Summarized, the temperature is the driving force of the CGHE. Two different methods are suggested to increase the heating rate up to the desired extraction temperature without changing the experimental equipment. Suggestions are made to improve the reliability of hydrogen determination depended on the hydrogen signal stability during extraction accompanied by Evaluation of the recorded data. Generally, independent temperature measurement with dummy specimens is useful for further data analysis, especially if this data is used for calculation of trapping kinetics by thermal desorption analysis (TDA).