Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (127) (entfernen)
Schlagworte
- ICP-MS (22)
- Laser ablation (16)
- Nanoparticle (12)
- Traceability (10)
- Imaging (8)
- Cell (7)
- PFAS (7)
- Metrology (6)
- Copper (5)
- Fluorescence (5)
- LA-ICP-MS (5)
- Uncertainty (5)
- Absolute isotope ratio (4)
- Calibration (4)
- HR-CS-GFMAS (4)
- Immunohistochemistry (4)
- Isotope dilution (4)
- Magnetic resonance imaging (4)
- Mass spectrometry (4)
- Measurement uncertainty (4)
- Brain (3)
- Cement (3)
- Extractable organically bound fluorine (EOF) (3)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (3)
- Human serum (3)
- Isotope ratio (3)
- Isotope ratios (3)
- LC-MS/MS (3)
- MC-ICP-MS (3)
- Nanoparticles (3)
- Reference material (3)
- Sulfur (3)
- Affinity chromatography (2)
- Analytical Chemistry (2)
- Bioconjugation (2)
- Bioimaging (2)
- Cancer (2)
- Cells (2)
- Comparability (2)
- Contrast agent (2)
- Delta scale (2)
- Delta value (2)
- Diatoms (2)
- Editorial (2)
- Environmental speciation (2)
- Fluorine (2)
- Gadolinium (2)
- General Earth and Planetary Sciences (2)
- ICP-ToF-MS (2)
- Interlaboratory comparison (2)
- Iron (2)
- Isotope dilution mass spectrometry (2)
- Isotope reference material (2)
- Isotopic fractionation (2)
- Lithium (2)
- MRI (2)
- Mercury (2)
- Metals (2)
- Metrology in chemistry (2)
- Molar mass (2)
- Nanomaterials (2)
- Nickel (2)
- Peptide (2)
- Peptide library (2)
- Per- and polyfluorinated alkyl substances (PFASs) (2)
- Purity (2)
- Quantification (2)
- SI (2)
- SI traceability (2)
- SPM (2)
- Single particle ICP-MS (2)
- Solid-liquid extraction (2)
- Sr isotopes (2)
- Triple isotope fractionation (2)
- 150th anniversary (1)
- 3D ultrastructural analysis (1)
- 6xHis (1)
- AAS (1)
- ABC (1)
- AF4 (1)
- ATCUN (1)
- Absorption spectrometry (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Adsorption (1)
- Affinity (1)
- Affinity extraction (1)
- Alanine scan (1)
- Albumin (1)
- Algorithms (1)
- Aluminum oxide (1)
- Alzheimer’s disease (1)
- Amyloid-beta (1)
- Analysis (1)
- Analytical chemistry (1)
- Analytical sciences (1)
- Anemia (1)
- Antifouling biocides (1)
- Antifouling-Biozide (1)
- Antikensammlung Berlin (1)
- App (1)
- Argon (1)
- Array (1)
- Arsenite (1)
- Atomic Absorption Spectrometry (1)
- Atomic Force Microscopy (1)
- Atomic absorption spectrometry (1)
- Atomic weight (1)
- Automated system (1)
- Avogadro constant (1)
- BAM (1)
- Bacterial lysates (1)
- Binding molecule (1)
- Bioapatite (1)
- Biodiesel fuel (1)
- Biogenic carbonates (1)
- Biological boron recycling (1)
- Bioseparation (1)
- Boron isotope (1)
- Boron isotope fractionation (1)
- Boron isotopic composition (1)
- Brassica napus (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Böden (1)
- CCQM (1)
- CE/MC-ICP-MS (1)
- CIC (1)
- CRM (1)
- Calcification (1)
- Calcium (1)
- Calcium monofluoride (1)
- Capillary electrophoresis-mass spectrometry (1)
- Carbodiimide crosslinking (1)
- Carrier (1)
- Cconventional method (1)
- Cellular trafficking (1)
- Central Taurus (1)
- Certification (1)
- Chelate (1)
- Chemometrie (1)
- Chemometrik (1)
- Chenopodium album (1)
- Chicken antibodies (1)
- Chromatography (1)
- Ciaaw.org (1)
- Classical primary measurement method (CPM) (1)
- Cleaning (1)
- Climate (1)
- Cluster (1)
- Collection (1)
- Combinatorial chemistry (1)
- Combustion Ion Chromatography (1)
- Combustion ion chromatography (CIC) (1)
- Complementary MS (1)
- Comsumer good samples (1)
- Confocal laser scanning microscopy (1)
- Conventional isotope ratio (1)
- Corophium volutator (1)
- Cryo-soft X-ray tomography (1)
- Cytoplasm (1)
- Cytoplasmic remodeling (1)
- Data processing (1)
- Degradation (1)
- Delta isotope standard (1)
- Dendritic polyglycerol sulfate (1)
- Diagenesis (1)
- Diagnostics (1)
- Diatomeenanalytik (1)
- Diffusion (1)
- Digestion (1)
- Dip-stick assay (1)
- Direct metal assay (1)
- Dissolution (1)
- Docking (1)
- Downstream processing (1)
- Dyes/pigments (1)
- EDTAD (1)
- ELISA (1)
- EPMA (1)
- Early Earth (1)
- Ecotoxicity (1)
- Ecotoxicological Testing (1)
- Ecotoxicology testing (1)
- Einzelzellanalyse (1)
- Elemental analysis (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Environment (1)
- Environmental pollution monitoring (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Exposure (1)
- Extracellular matrix (1)
- Extrahierbar organisch gebundenes Fluor (EOF) (1)
- Fe nanoparticles metabolism (1)
- Fertilizer (1)
- Finow Canal (1)
- Fluor (1)
- Fluorescence label (1)
- Fluorination (1)
- Fluorophilic interactions (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- GF-MAS (1)
- Gadolinium-based contrast agents (GBCAs) (1)
- Geochemistry (1)
- Geochemistry and Petrology (1)
- Geological material (1)
- Geophysics (1)
- Glycosaminoglycan (1)
- Graphite furnace (1)
- Greek curse tablets (1)
- Group profile (1)
- HF free Digestion (1)
- HPLC-ICP-MS (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Heat flow (1)
- HexaHis-Tag (1)
- High pH (1)
- High pressure experiments (1)
- High-fired gypsum mortar (1)
- High-purity elements (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- His6 (1)
- His8 (1)
- Hot-pressing (1)
- Hydrated silicate melts (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrogen (1)
- Hydrolysis products (1)
- Hydrothermal fluid (1)
- Hyphenated (1)
- ICP (1)
- ICP-MS/MS (1)
- ICP-TOF-MS (1)
- ICP-TOFMS (1)
- IDMS (1)
- ILC (1)
- IMAC purification (1)
- IgY (1)
- Iinductively coupled plasma mass spectrometry (1)
- Immunoaffinity extraction (1)
- Immunocapture (1)
- Immunofluorescence (1)
- Immunology (1)
- Impurity assessment (1)
- In situ (1)
- In vitro (1)
- In-house calibration solution (1)
- Industrielle Analytik (1)
- Inflammation (1)
- Inorganic chemical analysis (1)
- Instrumental isotope fractionation (1)
- Iposomes (1)
- Iridium (1)
- Iron nanoparticles (1)
- Iron oxide (1)
- Isotope (1)
- Isotope Dilution (1)
- Isotope amount ratio (1)
- Isotope delta (1)
- Isotope delta value (1)
- Isotope fractionation (1)
- Isotopes (1)
- Isotopic analysis (1)
- Isotopic dilution (1)
- Jahrestag (1)
- Kapillarelektrophorese-Massenspektrometrie (1)
- Kidney (1)
- Kilogram (1)
- Komplementäre Massenspektrometrie (1)
- Kristallolgraphie (1)
- LA-(MC-)ICP-MS (1)
- LA/ICP-MS Imaging (1)
- LSVEC (1)
- Lab-on-a-chip (1)
- Labeling (1)
- Lanthanide (1)
- Laser (1)
- Laser Ablation (1)
- Laser Ablation/Imaging (1)
- Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) (1)
- Lead (1)
- Lead isotope composition (1)
- Lead isotope ratios (1)
- Lead isotope variations (1)
- Lead isotopes (1)
- Legacy pollution (1)
- Life sciences (1)
- Limit of detection (1)
- Lymnaea stagnalis (1)
- MALDI-TOF MS (1)
- MC-TIMS (1)
- MST (1)
- Machine learning (1)
- Magnesium (1)
- Magnesium isotope ratios (1)
- Mass cytometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) (1)
- Measuremment uncertainty (1)
- Medicinal application (1)
- Mercury speciation (1)
- Mesoporous materials (1)
- Metal nanoclusters (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metalloprotein (1)
- Method (1)
- Methylmercury (1)
- Metrology in Chemistry (1)
- Micro-sublimation (1)
- Microdroplet generator (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Mixture toxicity (1)
- Mobile phase (1)
- Mole (1)
- Molecular imaging (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multielementanalytik (1)
- Multielementanalytik in kurzen transienten Signalen (1)
- Multimodal (1)
- Multimodale Analytik (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Nano-carrier (1)
- Nanocluster (1)
- Nanoparticle characterization (1)
- Nanopartikel (1)
- Nickel chelate (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Non-metal analysis (1)
- Non-target (1)
- OBOC library (1)
- Oberflächengewässer (1)
- Oberflächenwasser (1)
- On-chip screening (1)
- On-line CE/MC-ICP-MS (1)
- One-bead-one-compound library (1)
- Ore provenance (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- Pb isotopes (1)
- Peptide aptamers (1)
- Peptides and Proteins (1)
- Per- and Polyfluoroalkyl substances (PFAS) (1)
- Per- and polyfluorinated alkly substances (PFASs) (1)
- Photocatalysis (1)
- Plant tissue (1)
- Polarised light microscopy (1)
- Polishing (1)
- Pollutant (1)
- Pollution (1)
- Polyethylenimine (1)
- Polymer membrane (1)
- Pore fluids (1)
- Portland cement (1)
- Portland clinker (1)
- Priam's treasure (1)
- Primary calibration solution (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Programmed cell death (1)
- Protein imaging (1)
- Provenance (1)
- Provenancing (1)
- Prozessanalytik (1)
- Prozessindustrie (1)
- Pt-based drugs (1)
- PtNP (1)
- Purity assessment (1)
- Quality assurance (1)
- Quantitative protein analysis (1)
- Radiogenic isotopes (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Recombinant protein (1)
- Reference (1)
- Reference Materials (1)
- Reference measurements (1)
- Remediation (1)
- Revision of the SI (1)
- River water (1)
- River water sulfate (1)
- SC-ICP-MS (1)
- SERS (1)
- SI-traceability (1)
- SPR (1)
- Sample-sample bracketing (1)
- Sapphire (1)
- Scale anchor (1)
- Scale conversion (1)
- Schwebstoffe (1)
- Seawater (1)
- Sediment (1)
- Selenium (1)
- Sensor (1)
- Serum (1)
- Sewage sludge (1)
- Silbernanopartikel (1)
- Silica diagenesis (1)
- Silicon (1)
- Silicon isotopes (1)
- Single Cell (1)
- Single cell analysis (1)
- Single cell-ICP-MS (1)
- Single cell-ICP-ToF-MS (1)
- Single-cell analysis (1)
- Soil (1)
- Soil available boron (1)
- Soils (1)
- Solid phase extraction (SPE) (1)
- Spark plasma sintering (1)
- Special issue (1)
- Special issue, young analytical scientists (1)
- Speciation analysis (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrometer (1)
- Speroid (1)
- Spheroid (1)
- Sputtering (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stability (1)
- Stable isotopes (1)
- Standard atomic weight (1)
- Standardization (1)
- Statistical analysis (1)
- Strontium isotope (1)
- Sulfur isotopes (1)
- Sulphur isotope (1)
- Sum parameter (1)
- Surface plasmon resonance (1)
- Surface water (1)
- Surface waters (1)
- Synthetic peptides (1)
- Tantalum oxyfluorides (1)
- Tau (1)
- Test strips (1)
- Tetramethylammonium hydroxide (1)
- Thin tissue sections (1)
- Tissue (1)
- Tissue soldering (1)
- Titanium hydride (1)
- Total element content (1)
- Total element determination (1)
- Toxic elements (1)
- Toxicity (1)
- Transferrin (1)
- Transient signal (1)
- Trojan silver artefacts (1)
- Two-phase system (1)
- Umwelt-Speziation (1)
- Validation (1)
- WWTP (1)
- XRCD method (1)
- Xerogel (1)
- Ytterbium (1)
- Zinc (1)
- Zirconium (1)
- bell pepper (1)
- boron (1)
- delta value (1)
- isotope fractionation (1)
- lank characterization (1)
- measurement uncertainty (1)
- metabolism (1)
- silicon (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- Ägyptisches Museum Berlin (1)
- β-lactam (1)
Organisationseinheit der BAM
- 1.1 Anorganische Spurenanalytik (127) (entfernen)
Paper des Monats
- ja (3)
An alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry. For isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions, ranging from 0.06 to 0.99 mol mol–1, previously determined by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS). The calibration ML model was validated with two certified reference materials (LSVEC and IRMM-016). The procedure was applied toward the isotope amount ratio determination of a set of stock chemicals (Li2CO3, LiNO3, LiCl, and LiOH) and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. The results of these determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9 to 6.2‰. This precision was sufficient to resolve naturally occurring variations, as demonstrated for samples ranging from approximately −3 to +15‰. To assess its suitability to technical applications, the NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification. The results obtained were metrologically compatible with each other.
Boron (B) is an essential micronutrient for plant growth. Lack of valid methods for pretreatment and measurement of δ11B in plant restrict applications of it in the biosphere. Dry ashing, one step cation exchange and micro-sublimation were combined to separate and purify boron (B) in plant tissues. The low procedure blank, high B recovery and the accurate δ11B values of the plant reference materials demonstrate that this method is suitable and valid for B pretreatment and δ11B measurement in plant samples by MC-ICP-MS. Based on this method, the δ11B in different plants (Brassica napus, Chenopodium album L, moss, lichen, and Nostoc commune) was analyzed. For Brassica napus, δ11B increased gradually from root to leaf, and then decreased to rapeseed. For the same parts, the δ11B increased from the lower parts to the higher parts. This variation may be due to the B(OH)3 transporter of NIP6;1 and the incorporation of B into the cell. The reason for lower δ11B values in shell and rapeseed compared to those in leaves presumably is to the preferred Transport of borate in the phloem. The largest δ11B fractionation between leaf and root in Brassica napus and Chenopodium album L was +24.2‰ and +26.6‰, respectively. The large variation and fractionation of δ11B within plants indicates that δ11B is a good tracer to study the B translocation mechanisms and metabolism within plants. The δ11B in Nostoc commune, lichen, and moss showed variations of -4.1‰ to +21.5‰, −9.4‰ to +7.3‰, and −18.3‰ to +11. 9‰, respectively. In the same site, δ11B in different plants ranked Nostoc commune>moss>lichen and δ11B in mosses growing in different environment ranked soil>tree>rock. Rain and soil available B are the main B sources for these plants. The δ11B in Nostoc commune, lichen, and moss may be a useful tracer to study the atmospheric B input. In the future, plants culture experiments under certain environments and studies from molecular level are necessary to decipher the variation of δ11B and fractionation mechanisms within plants.
Boron isotope fractionation in soil-plant systems and its influence on biogeochemical cycling
(2022)
Boron (B) is an essential mineral nutrient for higher plants. Although B plant nutrition is well studied, the B isotope fractionation at the soil-plant interface, within plant metabolism, and its influence on biogeochemical cycling is not fully understood. Boron concentrations and isotope variations (δ11B) of the dicotyledonous plants of Chenopodium album and Brassica napus and their growing soils along a climatic gradient were analyzed to decipher these unresolved issues of the B behavior. The boron concentrations and δ11B values show an increasing trend from roots to leaves for both plants, while a decreasing trend from flower to shell and to seed for Brassica napus. A large boron isotope fractionation occurs within the plants with median Δ11Bleaf-root ≈ +20‰, which is related to different boron transporters and transportation ways. Formation of borate dimerized rhamnogalacturonan II in cell and B(OH)3 transportation in xylem lead to heavier δ11B values from root to stem and leaf while B(OH)4 transportation in phloem lead to lighter δ11B values from flower to shell and seed. Although samples cover a distinct transect with systematically different climatic conditions, Δδ11B within the individual plant compartments and between the bulk plants and the soil available B do not show any systematic variation.
This suggests that B uptake from the soil into Chenopodium album and Brassica napus occurs without a distinct isotope fractionation at the soil-plant interface (median Δ11Bbulkplant-soil = 0.2‰) and plants are able to regulate boron uptake. Both the observed large B fractionation within plant and low or absent B isotope fractionation at the soil-plant interface may have profound implications for the biological and geological B cycle. If this observed boron behavior also exists in other plants, their litters would be an important source for exporting 11B-rich biological material from continental ecosystems via rivers to the global oceans. This may be helpful for the explanation of ocean B cycle and the increasing δ11B values over the Cenozoic.
Accurate and precise isotope ratio measurements of heavy elements are playing an increasinglyimportant role in modern analytical sciences and have numerous applications. Today, isotope ratio measurements are typically performed with two principal techniques: thermal ionization mass spectrometry (TIMS) and multiple collector-inductively coupled plasma mass spectrometry (MC-ICP-MS). To obtain accurate results by mass spectrometry, isotopic certified reference materials (iCRMs) are needed for mass bias correction and for the validation of the method used for analysis.Thus, it is of paramount importance to achieve measurement comparability of all data reported, and to assess measurement capability of each CRM producer/National Metrology Institute (NMI). Therefore, the international comparison (CCQM-P213) was performed to assess the analytical capabilities of NMIs for the accurate determination of copper isotope ratio delta values in high purity materials. The study was proposed by the coordinating laboratories, National Research Council Canada (NRC), National Institute of Standards and Technology (NIST), Bundesanstalt für Materialforschung und -prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB), as an activity of the Isotope Ratio Working Group (IRWG) of the Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). Participants included six NMIs and one designated institute (DI) from the six countries. Although no measurement method was prescribed by the coordinating laboratories, MC-ICP-MS with either standard-sample bracketing (SSB) or combined SSB with internal normalization (C-SSBIN) models for mass bias correction were recommended. Results obtained from the six NMIs and one DI were in good agreement.
In this study, we demonstrate the applicability of nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) for Ca, Fe, and Se quantification in human serum using isotope dilution (ID) analysis. The matrix tolerance of MICAP-MS in Na matrix was investigated, uncovering that high Na levels can suppress the signal intensity. This suppression is likely due to the plasma loading and the space charge effect. Moreover, 40Ca and 44Ca isotopic fractionation was noted at elevated Na concentration. Nine certified serum samples were analyzed using both external calibration and ID analysis. Overestimation of Cr, Zn, As, and Se was found in the results of external calibration, which might be resulted from C-induced polyatomic interference and signal enhancement, respectively. Further investigations performed with methanol showed a similar enhancement effect for Zn, As, and Se, potentially supporting this assumption. The mass concentrations determined with ID analysis show metrological compatibility with the reference values, indicating that MICAP-MS combined with ID analysis can be a promising method for precise Ca, Fe, and Se determination. Moreover, this combination reduces the influences of matrix effects, broadening the applicability of MICAP-MS for samples with complex matrix.
Determination of elemental mass fractions in sediments plays a major role in evaluating the environmental status of aquatic ecosystems. Herewith, the optimization of a new total digestion protocol and the subsequent analysis of 48 elements in different sediment reference materials (NIST SRM 2702, GBW 07313, GBW 07311 and JMC-2) based on ICP-MS/MS detection is presented. The developed method applies microwave acid digestion and utilizes HBF4 as fluoride source for silicate decomposition. Similar to established protocols based on HF, HBF4 ensures the dissolution of the silicate matrix, as well as other refractory oxides. As HBF4 is not acutely toxic; no special precautions have to be made and digests can be directly measured via ICP-MS without specific sample inlet systems, evaporation steps or the addition of e.g. H3BO3, in order to mask excess HF. Different acid mixtures with and without HBF4 were evaluated in terms of digestion efficiency based on the trace metal recovery. The optimized protocol (5 mL HNO3, 2 mL HCL, 1 mL HBF4) allows a complete dissolution of the analyzed reference materials, as well as quantitative recoveries for a wide variety of certified analytes. Low recoveries for e.g. Sr, Ba and rare earth elements due to fluoride precipitation of HF-based digestions protocols, can be avoided by the usage of HBF4 instead. Based on the usage of high purity HBF4 all relevant trace, as well as matrix elements can be analyzed with sufficiently low LOQs (0.002 μg L−1 for U up to 6.7 μg L−1 for Al). In total, 34 elements were within a recovery range of 80%–120% for all three analyzed reference materials GBW 07313, GBW 07311 and JMC-2. 14 elements were outside a recovery range of 80%–120% for at least one of the analyzed reference materials.
Per- and polyfluoroalkyl substances (PFAS) are widely used for durable water-repellent finishing of different fabrics and textiles like outdoor clothing, carpets, medical textiles and more. Existing PFAS extraction techniques followed by target analysis are often insufficient in detecting widely used side-chain fluorinated polymers (SFPs) that are barely or non-extractable. SFPs are typically copolymers consisting of a non-fluorinated backbone with perfluoroalkyl side-chains to obtain desired properties. We compared the accessible analytical information and performance of complementary techniques based on oxidation (dTOP assay, PhotoTOP), hydrolysis (THP assay), standard extraction, extractable organic fluorine (EOF), and total fluorine (TF) with five functional textiles and characterized 7 further textiles only by PhotoTOP oxidation. The results show that when applied directly to textile samples, oxidation by dTOP and PhotoTOP and also hydrolysis by the THP are able to capture large fractions of the TF in form of perfluoroalkyl side-chains present in the textiles while methods relying on extracts (EOF, target and non-target analysis) were much lower (e.g., factor ~25-50 lower). The conversion of large fractions of the measured TF into PFCAs or FTOHs from fluorinated side chains is in contrast to previous studies. Concentrations ranged from <LOQ to over ~1000 mg F/kg after oxidation/hydrolysis and <LOQ to over 2000 mg F/kg for TF, while EOF and target PFAS in extracts were detected at much lower concentrations (up to ~ 60 mg F/kg) (amount of fluorine in the order: extraction << EOF << oxidation/hydrolysis ≤ TF). Perfluoroalkyl carboxylic acids (PFCAs) and fluorotelomer alcohols (FTOHs) from THP and PhotoTOP both represented the chain-length distribution in the textiles showing that long-chain SFPs are still used in current textiles. Further advantages and disadvantages of the applied methods are discussed.