Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (495)
- Vortrag (339)
- Posterpräsentation (206)
- Sonstiges (14)
- Forschungsdatensatz (11)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (4)
- Dissertation (4)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
- Forschungsbericht (2)
- Handbuch (1)
- Newsletter (1)
- Preprint (1)
Sprache
- Englisch (1087) (entfernen)
Schlagworte
- Fluorescence (107)
- Quantum yield (71)
- Nanoparticle (52)
- Quality assurance (51)
- ICP-MS (49)
- Laser ablation (48)
- Dye (47)
- Nano (43)
- Lifetime (42)
- LIBS (41)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1087) (entfernen)
Paper des Monats
- ja (12)
Nano- and microparticles are of increasing importance for a wide range of applications in the material and life sciences. Examples are their use as carriers for dye molecules and drugs, multichromophoric reporters for signal enhancement strategies in optical assays, targeted probes for bioimaging, and biosensors. All these applications require surface functionalization of the particles with e.g., ligands (to tune the dispersibility and prevent unspecific interactions), crosslinkers, sensor dyes, or analyte recognition moieties like biomolecules, and subsequently, the knowledge of the chemical nature and total number of surface groups as well as the number of groups accessible for coupling reactions. Particularly attractive for the latter are sensitive and fast photometric or fluorometric assays, which can be read out with simple, inexpensive instrumentation. Here, we present a novel family of cleavable photometric and multimodal reporters for the quantification of conjugatable amino and carboxyl surface groups on nano- and microparticles. These probes allow for the determination of particle-bound labels, unbound reporters in the supernatant, and reporters cleaved off from the particle surface as well as the remaining thiol groups on the particles by photometry and inductively coupled optical emission spectrometry (32S ICP-OES).3 Comparison of the performance of these cleavable reporters with conventional labels, utilizing changes in intensity and/or colour of absorption and/or emission, underlines the analytical potential of this versatile concept which elegantly circumvents signal distortions by light scattering and encoding dyes, and enables straightforward validation by method comparison.
An overview about different analytical approaches will be presented of how to detect metals in individual biological cells by use of ICP-MS. For this purpose, we are using different sample introduction systems for ICP-MS for detection, imaging and quantification of metals at cellular levels.
By use of laser ablation, we have studied the up-take by and distribution of nanoparticles in single cells. Recently we have developed staining techniques to measure protein and DNA content of cells and identifying the cell status by immunoassays using metal-tagging of antibodies. New research based on cell arrays will be shortly discussed.
Using pneumatic nebulization and microdroplet generation, we have also studied the up-take of nanoparticles and toxic metals as well as essential elements in single cells using different ICP-MS mass spectrometric concepts (sector field instrument, triple-quad instrument, time of flight (CyTOF) instrument).
The different ICP-MS based methods will be compared concerning their analytical figures of merit and their strengths and weaknesses will be evaluated.
Certification of the mass fractions of trace elements in a medium purity graphite reference material
(2018)
The increasing application of graphite materials in various fields of technology and science enhances the demand for strictly controlled properties which are often directly correlated to the contents of trace element impurities. Therefore, the availability of powerful, rapid and reliable analytical methods for the determination of trace impurities is essential for process and quality control. Certified reference materials, indispensable for the development and validation of appropriate trace analytical methods for the characterization of special purity graphite materials are still lacking. Therefore, BAM in co-operation with the working group “Special Materials” of the committee of chemists of GDMB (Gesellschaft der Metallurgen und Bergleute e.V.) certified an industrially sourced graphite material with genuine elemental impurities.
The candidate material was a commercial product (NBG 18) taken from the customary production line of the producer SGL CARBON, Chedde (France). The homogeneity of the powdered material was assessed by means of ETV-ICP OES and DC Arc-OES. Certification of the candidate reference material was based on an inter-laboratory comparison involving 17 expert laboratories from Germany, France, Slovenia, USA, South Africa. A variety of different mineralization, digestion, leaching, fusion and combustion techniques prior to ICP OES and photometry, methods without sample preparation (INAA, k0-INAA) as well as typical solid sampling methods (ETV-ICP OES, ETV-ICP-MS, SS-ET AAS, DC Arc-OES, MF-DC Arc-OES) were used to characterise the material. Certified mass fractions and their expanded uncertainties (k = 2) were assigned for 27 elements (Al, B, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, S, Si, Sr, Ti, V, W, Y, Zn, Zr), ranging from (0.00050 ± 0.00027) mg/kg for Be to (41 ± 6) mg/kg for Si. Additionally, informative values are given for the: trace element contents of Ag, As, Au, Bi, Cd, Cs, Dy, Eu, Ga, Gd, Hg, In, La, Nb, Rb, Re, Rh, Sb, Sc, Se, Sm, Sn, Ta, Tb, Te, Th, U; method specific values obtained by ETV-ICP OES (BETV and SiETV) and the ash content of the material.
The certified material “BAM-S009 Medium Purity Graphite Powder” is available for purchase from BAM.
Equipping ZIF particles with a polyelectrolyte membrane provides functional groups at their interface, enabling further conjugations necessary for applications such as targeted drug delivery. Previous approaches to coat ZIF particles with polyelectrolytes led to surface corrosion of the template material. This work overcomes previous limitations by performing a Layer-by-Layer (LbL) polyelectrolyte coating onto ZIF-8 and ZIF-67 particles in nonaqueous environment. Using the 2-methylimidazolium salt of polystyrensulfonic acid instead of the acid itself and polyethyleneimine in methanol led to intact ZIF particles after polyelectrolyte coating. This was verified by electron microscopy. Further, zetapotential and atomic force microscopy measurements confirmed a continuous polyelectrolyte multilayer built up. The here reported adaption to the well-studied (LbL) polyelectrolyte selfassembly process provides a facile method to equip ZIF particles with a nanometer thin polyelectrolyte multilayer membrane.
Small organic molecule drugs are one of the key classes, taking increasingly important roles in modern drug development strategies. With the focus on small molecule drugs, difficulties originate frequently from a pronounced lipophilic character, resulting in poor water solubility, low bioavailability and unfavored pharmacokinetics. Recently, peptide-poly(ethylene glycol) conjugates (peptide-PEG conjugates) were described as precisely tunable platforms to solubilize a broad scope of fluorescent or non-fluorescent small organic molecules [1-2]. Selection of drug hosting peptides was achieved by combinatorial means, which can further be extended by implementation of a drug release screening step.
One-bead-one-compound peptide libraries are powerful tools to select high affinity binders. However, the selection of positive hits from the peptide libraries remains tedious as it occurs by handpicking, strongly limiting the pool of investigated beads. Here we report our recent results on improving the analytical platform, using automated fluorescence scanning and MALDI-ToF-ToF MS/MS imaging to screen larger sets of beads, broadening the statistical base and unraveling more precisely suitable peptides. The screening puts special emphasis on loading capacities and drug-release of transporters by performing additional washing steps in different media (cf. Fig. 1). Peptides representing strong, medium, weak releaser were chosen for further analysis and synthesized as peptide-polymer transporters. Release was analyzed by fluorescence anisotropy and fluorescence correlation spectroscopy, due to the fluorescent characteristics of the drug.
Solubilization studies confirmed sufficient loading capacities for a potential anti-Alzheimer disease drug of three transporter molecules representing strong/weak drug releaser, reaching solubilization of up to 1:3.4 (µmol drug/µmol conjugate). Fluorescence anisotropy and fluorescence correlation spectroscopy of the drug-loaded transporter showed significant differences in drug releasing properties, confirming the screening process.
2-Amino-2-(hydroxymethyl)-1,3-propanediol (TRIS) and ethylene-diaminetetraacetic acid (EDTA) are key components of biological buffers and are frequently used as DNA stabilizers in irradiation studies. Such surface or liquid phase studies are done with the aim to understand the fundamental mechanisms of DNA radiation damage and to improve cancer radiotherapy. When ionizing radiation is used, abundant secondary electrons are formed during the irradiation process, which are able to attach to the molecular compounds present on the surface. In the present study we experimentally investigate low energy electron attachment to TRIS and methyliminodiacetic acid (MIDA), an analogue of EDTA, supported by quantum chemical calculations. The most prominent dissociation channel for TRIS is through hydroperoxyl radical formation, whereas the dissociation of MIDA results in the formation of formic and acetic acid. These compounds are well-known to cause DNA modifications, like strand breaks. The present results indicate that buffer compounds may not have an exclusive protecting effect on DNA as suggested previously.
During cancer radiation therapy high‐energy radiation is used to reduce tumour tissue. The irradiation produces a shower of secondary low‐energy (<20 eV) electrons, which are able to damage DNA very efficiently by dissociative electron attachment. Recently, it was suggested that low‐energy electron‐induced DNA strand breaks strongly depend on the specific DNA sequence with a high sensitivity of G‐rich sequences. Here, we use DNA origami platforms to expose G‐rich telomere sequences to low‐energy (8.8 eV) electrons to determine absolute cross sections for strand breakage and to study the influence of sequence modifications and topology of telomeric DNA on the strand breakage. We find that the telomeric DNA 5′‐(TTA GGG)2 is more sensitive to low‐energy electrons than an intermixed sequence 5′‐(TGT GTG A)2 confirming the unique electronic properties resulting from G‐stacking. With increasing length of the oligonucleotide (i.e., going from 5′‐(GGG ATT)2 to 5′‐(GGG ATT)4), both the variety of topology and the electron‐induced strand break cross sections increase. Addition of K+ ions decreases the strand break cross section for all sequences that are able to fold G‐quadruplexes or G‐intermediates, whereas the strand break cross section for the intermixed sequence remains unchanged. These results indicate that telomeric DNA is rather sensitive towards low‐energy electron‐induced strand breakage suggesting significant telomere shortening that can also occur during cancer radiation therapy.
Absolute Isotope Ratios
(2018)
Measurement results and scientific models leading to important decisions in forensics, food fraud or climatology are based on isotope ratio data. Molar masses of multi-isotopic elements are as well based on isotope ratio data. Thus, in the case of Si, isotope ratios directly impact the redefinition of the SI base units kilogram and mole. Therefore, new strategies are required leading to new primary isotope reference materials, whose isotope ratios are traceable to the SI. This in turn will ensure the comparability of isotope ratio data and will render the traceability exception requested by the CCQM superfluous. Such new procedures will be developed for the key elements S, Si, Ca, Sr and Nd at relative uncertainty levels of ≤ 0.01 %.
In chemical elements with three or more stable isotopes, mass-dependent stable isotope fractionation is expressed by co-varying isotope ratios. In the three-isotope space ((δ’m2/δ’m1)/(( δ’m3/δ’m1)) these plot along a line with a slope (β), the so called ‘terrestrial fractionation line’. This partitioning of stable isotopes results from both kinetic and equilibrium reactions that are characterized by specific β-values.
For the natural range of isotope ratios of ‘novel’ stable isotope systems such as Si, Mg, Fe, Zn, Cu this information cannot be accessed because samples fall close to the delta-zero standard where the current measurement precision is too low to resolve small differences in β. We present a new approach to resolve deviations from a reference slope β by standard-sample bracketing against material offset from the natural range. We use this approach to explore the isotope fractionation mechanism in the mammalian food web. We have analyzed Mg stable isotope ratios in bone bioapatite of herbivore, omnivore and carnivore mammals. Positive shifts in δ26/24Mg along the trophic chain (from herbivore to carnivore) together with β= 0.513 suggest the presence of two isotope fractionation mechanisms operating during biomineralization. While positive shifts in δ26/24Mg are in favor of equilibrium isotope fractionation process, the proximity of β to the theoretically calculated β(kinetic) of typically 0.511 suggests the presence of a second component that fractionates stable isotopes kinetically. The herein presented approach is applicable to any element with 3+ stable isotopes analyzed by multi-collector inductively coupled plasma mass spectrometry.
This is the first time that PE frits were used to quantify sulfur in copper and its alloys by isotope dilution combined with LA-ICP-MS: an alternative approach for sample preparation. The following properties of the PE frit meet the requirements for isotope dilution LA-ICPMS:: porous material, thermo plastic (melting point >100oC), chemical resistance (nitric acid >70%) and high adsorption efficiency. The breakthrough, however, as a support material, especially when comparing the PE frit with other materials such gelatin or sodium silicate is the low blank, which is only two times of the gas flow blank (2.3-4.0 x 104 cps). Additionally, the porosity of the frit was considered, as it directly affects the adsorption efficiency for the sample solution, which is present in the cavities of the frit.
Adsorption efficiency was studied by depositing sulfur standards with varying sulfur amounts (0, 2, 5, 10, 20, 40 and 80 µg S) on the frits. The remaining sulfur which was not absorbed by the frit was rinsed off and was measured by ICP-MS. This indirect method shows that more than 99.5 % of the loaded sulfur was absorbed by the frit. Such high absorption efficiency is completely sufficient for a support material to be used in LA-ICP-IDMS. The so prepared frits whith increasing sulfur amount were measured by LA-ICP-MS showing a good linearity between 0 µg S and 40 µg S whit a correlation coefficient r2 of 0.9987 and sensitivy of 3.4x104 cpsµg-1 for 32S.
Three copper reference materials produced by BAM were selected to develop and validate the LA-ICP-IDMS procedure. The IDMS technique was applied to these samples as follows: the samples were spiked, dissolved, digested and then the digest was adsorbed on the frits.