Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (126) (entfernen)
Schlagworte
- ICP-MS (21)
- Laser ablation (15)
- Nanoparticle (12)
- Traceability (10)
- Imaging (8)
- PFAS (7)
- Cell (6)
- Metrology (6)
- Copper (5)
- Fluorescence (5)
- LA-ICP-MS (5)
- Uncertainty (5)
- Absolute isotope ratio (4)
- Calibration (4)
- HR-CS-GFMAS (4)
- Immunohistochemistry (4)
- Isotope dilution (4)
- Magnetic resonance imaging (4)
- Mass spectrometry (4)
- Measurement uncertainty (4)
- Brain (3)
- Cement (3)
- Extractable organically bound fluorine (EOF) (3)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (3)
- Human serum (3)
- Isotope ratio (3)
- Isotope ratios (3)
- LC-MS/MS (3)
- MC-ICP-MS (3)
- Nanoparticles (3)
- Reference material (3)
- Sulfur (3)
- Affinity chromatography (2)
- Analytical Chemistry (2)
- Bioconjugation (2)
- Bioimaging (2)
- Cancer (2)
- Cells (2)
- Comparability (2)
- Contrast agent (2)
- Delta scale (2)
- Delta value (2)
- Diatoms (2)
- Editorial (2)
- Environmental speciation (2)
- Fluorine (2)
- Gadolinium (2)
- General Earth and Planetary Sciences (2)
- ICP-ToF-MS (2)
- Interlaboratory comparison (2)
- Iron (2)
- Isotope dilution mass spectrometry (2)
- Isotope reference material (2)
- Isotopic fractionation (2)
- Lithium (2)
- MRI (2)
- Mercury (2)
- Metals (2)
- Metrology in chemistry (2)
- Molar mass (2)
- Nanomaterials (2)
- Nickel (2)
- Peptide (2)
- Peptide library (2)
- Per- and polyfluorinated alkyl substances (PFASs) (2)
- Purity (2)
- Quantification (2)
- SI (2)
- SI traceability (2)
- SPM (2)
- Single particle ICP-MS (2)
- Solid-liquid extraction (2)
- Sr isotopes (2)
- Triple isotope fractionation (2)
- 150th anniversary (1)
- 3D ultrastructural analysis (1)
- 6xHis (1)
- AAS (1)
- ABC (1)
- AF4 (1)
- ATCUN (1)
- Absorption spectrometry (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Adsorption (1)
- Affinity (1)
- Affinity extraction (1)
- Alanine scan (1)
- Albumin (1)
- Algorithms (1)
- Aluminum oxide (1)
- Alzheimer’s disease (1)
- Amyloid-beta (1)
- Analysis (1)
- Analytical chemistry (1)
- Analytical sciences (1)
- Anemia (1)
- Antifouling biocides (1)
- Antifouling-Biozide (1)
- Antikensammlung Berlin (1)
- App (1)
- Argon (1)
- Array (1)
- Arsenite (1)
- Atomic Absorption Spectrometry (1)
- Atomic Force Microscopy (1)
- Atomic absorption spectrometry (1)
- Atomic weight (1)
- Automated system (1)
- Avogadro constant (1)
- BAM (1)
- Bacterial lysates (1)
- Binding molecule (1)
- Bioapatite (1)
- Biodiesel fuel (1)
- Biogenic carbonates (1)
- Biological boron recycling (1)
- Bioseparation (1)
- Boron isotope (1)
- Boron isotope fractionation (1)
- Boron isotopic composition (1)
- Brassica napus (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Böden (1)
- CCQM (1)
- CE/MC-ICP-MS (1)
- CIC (1)
- CRM (1)
- Calcification (1)
- Calcium (1)
- Calcium monofluoride (1)
- Capillary electrophoresis-mass spectrometry (1)
- Carbodiimide crosslinking (1)
- Carrier (1)
- Cconventional method (1)
- Cellular trafficking (1)
- Central Taurus (1)
- Certification (1)
- Chelate (1)
- Chemometrie (1)
- Chemometrik (1)
- Chenopodium album (1)
- Chicken antibodies (1)
- Chromatography (1)
- Ciaaw.org (1)
- Classical primary measurement method (CPM) (1)
- Cleaning (1)
- Climate (1)
- Cluster (1)
- Collection (1)
- Combinatorial chemistry (1)
- Combustion ion chromatography (1)
- Combustion ion chromatography (CIC) (1)
- Complementary MS (1)
- Comsumer good samples (1)
- Confocal laser scanning microscopy (1)
- Conventional isotope ratio (1)
- Corophium volutator (1)
- Cryo-soft X-ray tomography (1)
- Cytoplasm (1)
- Cytoplasmic remodeling (1)
- Data processing (1)
- Degradation (1)
- Delta isotope standard (1)
- Dendritic polyglycerol sulfate (1)
- Diagenesis (1)
- Diagnostics (1)
- Diatomeenanalytik (1)
- Diffusion (1)
- Digestion (1)
- Dip-stick assay (1)
- Direct metal assay (1)
- Dissolution (1)
- Docking (1)
- Downstream processing (1)
- Dyes/pigments (1)
- EDTAD (1)
- ELISA (1)
- EPMA (1)
- Early Earth (1)
- Ecotoxicity (1)
- Ecotoxicological Testing (1)
- Ecotoxicology testing (1)
- Einzelzellanalyse (1)
- Elemental analysis (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Environment (1)
- Environmental pollution monitoring (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Exposure (1)
- Extracellular matrix (1)
- Extrahierbar organisch gebundenes Fluor (EOF) (1)
- Fe nanoparticles metabolism (1)
- Fertilizer (1)
- Finow Canal (1)
- Fluor (1)
- Fluorescence label (1)
- Fluorination (1)
- Fluorophilic interactions (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- GF-MAS (1)
- Gadolinium-based contrast agents (GBCAs) (1)
- Geochemistry (1)
- Geochemistry and Petrology (1)
- Geological material (1)
- Geophysics (1)
- Glycosaminoglycan (1)
- Graphite furnace (1)
- Greek curse tablets (1)
- Group profile (1)
- HF free Digestion (1)
- HPLC-ICP-MS (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Heat flow (1)
- HexaHis-Tag (1)
- High pH (1)
- High pressure experiments (1)
- High-fired gypsum mortar (1)
- High-purity elements (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- His6 (1)
- His8 (1)
- Hot-pressing (1)
- Hydrated silicate melts (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrogen (1)
- Hydrolysis products (1)
- Hydrothermal fluid (1)
- Hyphenated (1)
- ICP-MS/MS (1)
- ICP-TOF-MS (1)
- ICP-TOFMS (1)
- IDMS (1)
- ILC (1)
- IMAC purification (1)
- IgY (1)
- Iinductively coupled plasma mass spectrometry (1)
- Immunoaffinity extraction (1)
- Immunocapture (1)
- Immunofluorescence (1)
- Immunology (1)
- Impurity assessment (1)
- In situ (1)
- In vitro (1)
- In-house calibration solution (1)
- Industrielle Analytik (1)
- Inflammation (1)
- Inorganic chemical analysis (1)
- Instrumental isotope fractionation (1)
- Iposomes (1)
- Iridium (1)
- Iron nanoparticles (1)
- Iron oxide (1)
- Isotope (1)
- Isotope Dilution (1)
- Isotope amount ratio (1)
- Isotope delta (1)
- Isotope delta value (1)
- Isotope fractionation (1)
- Isotopes (1)
- Isotopic analysis (1)
- Isotopic dilution (1)
- Jahrestag (1)
- Kapillarelektrophorese-Massenspektrometrie (1)
- Kidney (1)
- Kilogram (1)
- Komplementäre Massenspektrometrie (1)
- Kristallolgraphie (1)
- LA-(MC-)ICP-MS (1)
- LA/ICP-MS Imaging (1)
- LSVEC (1)
- Lab-on-a-chip (1)
- Labeling (1)
- Lanthanide (1)
- Laser (1)
- Laser Ablation (1)
- Laser Ablation/Imaging (1)
- Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) (1)
- Lead (1)
- Lead isotope composition (1)
- Lead isotope ratios (1)
- Lead isotope variations (1)
- Lead isotopes (1)
- Legacy pollution (1)
- Life sciences (1)
- Limit of detection (1)
- Lymnaea stagnalis (1)
- MALDI-TOF MS (1)
- MC-TIMS (1)
- MST (1)
- Machine learning (1)
- Magnesium (1)
- Magnesium isotope ratios (1)
- Mass cytometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) (1)
- Measuremment uncertainty (1)
- Medicinal application (1)
- Mercury speciation (1)
- Mesoporous materials (1)
- Metal nanoclusters (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metalloprotein (1)
- Method (1)
- Methylmercury (1)
- Metrology in Chemistry (1)
- Micro-sublimation (1)
- Microdroplet generator (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Mixture toxicity (1)
- Mobile phase (1)
- Mole (1)
- Molecular imaging (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multielementanalytik (1)
- Multielementanalytik in kurzen transienten Signalen (1)
- Multimodal (1)
- Multimodale Analytik (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Nano-carrier (1)
- Nanocluster (1)
- Nanoparticle characterization (1)
- Nanopartikel (1)
- Nickel chelate (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Non-metal analysis (1)
- Non-target (1)
- OBOC library (1)
- Oberflächengewässer (1)
- Oberflächenwasser (1)
- On-chip screening (1)
- On-line CE/MC-ICP-MS (1)
- One-bead-one-compound library (1)
- Ore provenance (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- Pb isotopes (1)
- Peptide aptamers (1)
- Peptides and Proteins (1)
- Per- and polyfluorinated alkly substances (PFASs) (1)
- Per- and polyfluoroalkyl substances (PFAS) (1)
- Photocatalysis (1)
- Plant tissue (1)
- Polarised light microscopy (1)
- Polishing (1)
- Pollutant (1)
- Pollution (1)
- Polyethylenimine (1)
- Polymer membrane (1)
- Pore fluids (1)
- Portland cement (1)
- Portland clinker (1)
- Priam's treasure (1)
- Primary calibration solution (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Programmed cell death (1)
- Protein imaging (1)
- Provenance (1)
- Provenancing (1)
- Prozessanalytik (1)
- Prozessindustrie (1)
- Pt-based drugs (1)
- PtNP (1)
- Purity assessment (1)
- Quality assurance (1)
- Quantitative protein analysis (1)
- Radiogenic isotopes (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Recombinant protein (1)
- Reference (1)
- Reference Materials (1)
- Reference measurements (1)
- Remediation (1)
- Revision of the SI (1)
- River water (1)
- River water sulfate (1)
- SC-ICP-MS (1)
- SERS (1)
- SI-traceability (1)
- SPR (1)
- Sample-sample bracketing (1)
- Sapphire (1)
- Scale anchor (1)
- Scale conversion (1)
- Schwebstoffe (1)
- Seawater (1)
- Sediment (1)
- Selenium (1)
- Sensor (1)
- Serum (1)
- Sewage sludge (1)
- Silbernanopartikel (1)
- Silica diagenesis (1)
- Silicon (1)
- Silicon isotopes (1)
- Single Cell (1)
- Single cell analysis (1)
- Single cell-ICP-MS (1)
- Single cell-ICP-ToF-MS (1)
- Single-cell analysis (1)
- Soil (1)
- Soil available boron (1)
- Soils (1)
- Solid phase extraction (SPE) (1)
- Spark plasma sintering (1)
- Special issue (1)
- Special issue, young analytical scientists (1)
- Speciation analysis (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrometer (1)
- Speroid (1)
- Spheroid (1)
- Sputtering (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stability (1)
- Stable isotopes (1)
- Standard atomic weight (1)
- Standardization (1)
- Statistical analysis (1)
- Strontium isotope (1)
- Sulfur isotopes (1)
- Sulphur isotope (1)
- Sum parameter (1)
- Surface plasmon resonance (1)
- Surface water (1)
- Surface waters (1)
- Synthetic peptides (1)
- Tantalum oxyfluorides (1)
- Tau (1)
- Test strips (1)
- Tetramethylammonium hydroxide (1)
- Thin tissue sections (1)
- Tissue (1)
- Tissue soldering (1)
- Titanium hydride (1)
- Total element content (1)
- Total element determination (1)
- Toxic elements (1)
- Toxicity (1)
- Transferrin (1)
- Transient signal (1)
- Trojan silver artefacts (1)
- Two-phase system (1)
- Umwelt-Speziation (1)
- Validation (1)
- WWTP (1)
- XRCD method (1)
- Xerogel (1)
- Ytterbium (1)
- Zinc (1)
- Zirconium (1)
- bell pepper (1)
- boron (1)
- delta value (1)
- isotope fractionation (1)
- lank characterization (1)
- measurement uncertainty (1)
- metabolism (1)
- silicon (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- Ägyptisches Museum Berlin (1)
- β-lactam (1)
Organisationseinheit der BAM
- 1.1 Anorganische Spurenanalytik (126) (entfernen)
Paper des Monats
- ja (4)
Previously applied methods for the quantification of sulphur in copper and other pure metals revealed a lack of SI-traceability and additionally showed inconsistent results, when different methods were compared.
Therefore, a reference procedure is required which allows SI-traceable values accompanied by a Sound uncertainty budget. In this study a procedure was developed for the quantification of total sulphur in copper at low concentration levels using inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS). The major part of the copper matrix was separated by adding ammonia which forms a complex with the copper while releasing the sulphur followed by chromatographic separation using a weak cation resin. After that the sulphur fraction was further purified by chromatographic means using first an anion exchange method and second a chelating resin. The developed procedure shows high performance, especially concerning high efficiency in matrix removal (>99.999%) while keeping the recovery of sulphur above 80%. Procedure blanks are in the order of 3–53 ng resulting in LOD and LOQ values of 0.2 mg g1 and 0.54 mg g1, respectively. The procedure is sufficient to facilitate value assignment of the total sulphur mass fraction in reference materials. Additionally, relative measurement uncertainties were calculated to be below 1% and the measurement results were traceable to the SI. The procedure reported in this study is a new reference procedure for sulphur measurement in copper, being fit for two major purposes, certification of reference materials and assignment of reference values for inter-laboratory comparison.
Silicon isotope fractionation during silicification is poorly understood and impedes our ability to decipher paleoenvironmental conditions from Si isotopes in ancient cherts. To investigate isotope fractionation during silica-for-carbonate replacement we analyzed the microscale Si and O isotope composition in different silica phases in a silicified zebra dolostone as well as their bulk δ18O and Δ’17O compositions. The subsequent replacement of carbonate layers is mimicked by decreasing δ18O and δ30Si. The textural relationship and magnitude of Si and O isotope fractionation is best explained by near-quantitative silica precipitation in an open system with finite Si. A Rayleigh model for silicification suggests positive Ɛ30/28Si during silicification, conforming with predictions for isotope distribution at chemical equilibrium from ab-initio models. Application of the modelled Ɛ30Si-T relationship yields silicification temperatures of approx. 50°C. To reconcile the δ18Ochert composition with these temperatures, the δ18O of the fluid must have been between -2.5 and -4 ‰, compositions for which the quartz phases fall close to the oxygen equilibrium fractionation line in three-isotope space. Diagenetic silica replacement appears to occur in O and Si isotopic equilibrium allowing reconstructions of temperatures of silicification from Si isotopes and derive the δ18O composition of the fluid – a highly desired value needed for accurate reconstructions of the temperature- and δ18O histories of the oceans.
Asymmetrical Flow Field-Flow Fractionation (AF4), as a cleaning technique, was combined on-line with the multielemental analytical capabilities of an Inductively Coupled Plasma-Time of Flight-Mass Spectrometer (ICP-ToF-MS). In that manner, the heavy ionic matrix effect of untreated cells' samples can be significantly reduced. As a proof of concept, commercial baker's yeast cells were analysed.
Diatoms play a key role in assessing the eco-toxicology of metals and are already part of several national and international guidelines and regulations. Data on metal uptake and its correlation with a natural metal composition of the diatoms are mostly lacking on a cellular basis - mainly due to the lack of a suitable method on both the preparation and detection side. Therefore, within this work a fully automated approach based on the on-line coupling of a high performance liquid chromatograph (HPLC) and an inductively coupled plasma-time of flight-mass spectrometer (ICP-ToF-MS) was applied to analyze single cells of the alga Cyclotella meneghiniana multi-elementally in order to provide a deeper insight into the metal composition and its response to environmental stress. Multi-elemental analysis in single diatoms also enables assessment of combined toxicity of a set of metals. A set of four fingerprint elements, characteristically for diatoms (Mg, P, Si, Fe), were identified and hence the investigation of environmental stress onto the cells was enabled by performing incubation experiments with environmentally relevant toxic elements. It could be shown at moderate environmental stress caused by increasing the metal concentration in the medium (zinc) that the fingerprint element concentrations remained stable and thus the suitability of the selected elements for algae tracing was demonstrated. With regard to further ecotoxicological assessments, a multivariate approach was successfully applied allowing for cell classification upon different incubation concentration levels. This multivariate approach also facilitated an effective identification of three different diatom species (Cyclotella meneghiniana, Thalassiosira weissflogii and Thalassiosira pseudonana).
An automated and straightforward detection and data treatment strategy for the determination of the protein relative concentration in individual human cells by single cell–inductively coupled plasma–time-of-flight mass spectrometry (sc-ICP-ToF-MS) is proposed. Metal nanocluster (NC)-labeled specific antibodies for the target proteins were employed, and ruthenium red (RR) staining, which binds to the cells surface, was used to determine the number of cell events as well as to evaluate the relative volume of the cells. As a proof of concept, the expression of hepcidin, metallothionein-2, and ferroportin employing specific antibodies labeled with IrNCs, PtNCs, and AuNCs, respectively, was investigated by sc-ICP-ToF-MS in human ARPE-19 cells. Taking into account that ARPE-19 cells are spherical in suspension and RR binds to the surface of the cells, the Ru intensity was related to the cell volume (i.e., the cell volume is directly proportional to (Ru intensity)3/2), making it possible to determine not only the mass of the target proteins in each individual cell but also the relative concentration. The proposed approach is of particular interest in comparing cell cultures subjected to different supplementations. ARPE-19 cell cultures under two stress conditions were compared: a hyperglycemic model and an oxidative stress model. The comparison of the control with treated cells shows not only the mass of analyzed species but also the relative changes in the cell volume and concentration of target proteins, clearly allowing the identification of subpopulations under the respective treatment.
Single-cell analysis by ICP-MS/MS as a fast tool for cellular bioavailability studies of arsenite
(2018)
Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) has become a powerful and fast tool to evaluate the elemental composition at a single-cell level. In this study, the cellular bioavailability of arsenite (incubation of 25 and 50 μM for 0-48 h) has been successfully assessed by SC-ICP-MS/MS for the first time directly after re-suspending the cells in water. This procedure avoids the normally arising cell membrane permeabilization caused by cell fixation methods (e.g. methanol fixation). The reliability and feasibility of this SC-ICP-MS/MS approach with a limit of detection of 0.35 fg per cell was validated by conventional bulk ICP-MS/MS analysis after cell digestion and parallel measurement of sulfur and phosphorus.
Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) has become an effective tool for the detection and quantification of inorganic nanoparticles (NPs). While sizing of NPs suspended in water is relatively straightforward by sp-ICP-MS, accurate mass quantification of NPs in complex media, such as consumer products and natural systems still remains a challenge. When NPs are suspended in a complex medium, the matrix may affect the analyte sensitivity and lead to inaccurate NP sizing. Here, we investigate the use of an online microdroplet calibration system to size NPs in a single step. In this setup, microdroplets—which are used as the calibrant to determine elemental sensitivities—and nebulized NP-containing solutions are introduced concurrently into the ICP via a dual-inlet sample introduction system. Because calibrant microdroplets and analyte NPs experience the same plasma conditions, both the microdroplets and the NPs are subjected to the same matrix-related signal enhancement or suppression. In this way, the microdroplet calibration standards are automatically matrix matched with the NP-containing solution. The online microdroplet calibration system is combined with an ICP-TOFMS instrument for simultaneous measurement of multiple elements in microdroplets and NPs. We investigate the ability of online microdroplet calibration to compensate for matrix effects through a series of experiments, in which Ag and Au NPs are measured with variable plasma-sampling positions, varying concentrations of HCl and HNO3, varying concentrations of single element solutions, and high concentrations of a salt matrix, i.e. phosphate buffered saline (PBS). Through these experiments, we demonstrate that the online microdroplet calibration strategy provides a matrix-independent mass quantification of analyte NPs in the presence of several established types of matrix effects, including acid effects, space-charge effects, and ionisation suppression. In results presented here, we focus on the size determination of the NPs.
Within this work, the combination of a microdroplet generator and an ICP-ToF-MS for nanoparticle analysis is presented. For the size determination of platinum nanoparticles an on-line isotope dilution analysis approach was developed. The 194Pt/195Pt isotopic ratio was used for the characterization of the particles, while the 182W/183W isotopic ratio was monitored simultaneously for mass bias correction. The on-line ID-MDG-sp-ICP-ToF-MS approach was deployed for the size determination of three platinum nanoparticle samples (50 nm, 63 nm, 70 nm); for validation, complementary size characterization techniques (sp-ICP-ToF-MS and TEM) were used. The robustness of this technique was evidenced, by using sodium chloride concentrations up to 100 mg L−1 as a matrix component. Our new on-line ID MDG-sp-ICP-ToF-MS approach is a promising tool for the fast and reliable determination of nanoparticles' size in severe matrix concentrations, e.g., environmental samples.
A recently introduced inductively coupled plasma-time-of-flight-mass spectrometer (ICP-ToF-MS) shows enhanced sensitivity compared to previous developments and superior isotope ratio precision compared to other ToF and commonly used single-collector ICP-MS instruments. Following this fact, an improvement for isotope dilution ICP-MS using the new instrumentation has been reported. This study aimed at investigating whether this improvement also meets the requirements of species-specific isotope dilution using GC/ICP-MS, where short transient signals are recorded. The results of the analysis of monomethylmercury (MMHg) of a sediment reference material show that isotope ratio precision of ICP-MS instruments equipped with quadrupole, sector-field, and time-of-flight mass analyzers is similar within a broad range of peak signal-to-noise ratio when analyzing one isotopic system. The procedural limit of quantification (LOQ) for MMHg, expressed as mass fraction of Hg being present as MMHg, w(Hg)MMHg, was similar as well for all investigated instruments and ranged between 0.003 and 0.016 μg/kg. Due to the simultaneous detection capability, the ICP-ToF-MS might, however, be more favorable when several isotopic systems are analyzed within one measurement. In a case study, the GC/ICP-ToF-MS coupling was applied for analysis of MMHg in sediments of Finow Canal, a historic German canal heavily polluted with mercury. Mass fractions between 0.180 and 41 μg/kg (w(Hg)MMHg) for MMHg, and 0.056 and 126 mg/kg (w(Hg)total) for total mercury were found in sediment samples taken from the canal upstream and downstream of a former chemical plant.
Metal tags find application in a multitude of biomedical systems and the combination with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) offers an opportunity for multiplexing. To lay the foundation for an increase of the signal intensities in such processes, we herein present a general approach for efficient functionalization of a well-defined metal oxido cluster [Bi6O4(OH)(4)(SO3CF3)(6)(CH3CN)(6)].2 CH3CN (1), which can be realized by selecting 7mer peptide sequences via combinatorial means from large one-bead one-compound peptide libraries. Selective cluster-binding peptide sequences (CBS) for 1 were discriminated from non-binders by treatment with H2S gas to form the reduction product Bi2S3, clearly visible to the naked eye. Interactions were further confirmed by NMR experiments. Extension of a binding peptide with a maleimide linker (Mal) introduces the possibility to covalently attach thiol-bearing moieties such as biological probes and for their analysis the presence of the cluster instead of mononuclear entities should lead to an increase of signal intensities in LA-ICP-MS measurements. To prove this, CBS-Mal was covalently bound onto thiol-presenting glass substrates, which then captured 1 effectively, so that LA-ICP-MS measurements demonstrated drastic signal amplification compared to single lanthanide tags.