- nein (25)
This paper explores combining a gimbal-mounted tunable diode laser absorption spectroscopy (TDLAS) sensor and a video camera to create a virtual gas camera for methane leak detection. This provides a low-to-zero-cost extension of typical TDLAS gas tomography systems. A prototype setup mounted on a ground robot is evaluated. Results acquired using a simulated methane leak show the feasibility of the virtual gas camera, accurately detecting methane leaks by overlaying concentrations onto a visual image. While the acquisition time is significantly longer than for traditional gas cameras, potential enhancements are discussed. The study concludes that the virtual gas camera is feasible and useful, despite its longer acquisition time. It serves as a valuable software-only addition to typical TDLAS gas tomography systems, offering quickly-available on-site data augmentation for visual leak assessment at low-to-zero cost.
This paper outlines significant advancements in our previously developed aerial gas tomography system, now optimized to reconstruct 2D tomographic slices of gas plumes with enhanced precision in outdoor environments. The core of our system is an aerial robot equipped with a custom-built 3-axis aerial gimbal, a Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor for CH4 measurements, a laser rangefinder, and a wide-angle camera, combined with a state-of-the-art gas tomography algorithm. In real-world experiments, we sent the aerial robot along gate-shaped flight patterns over a semi-controlled environment with a static-like gas plume, providing a welldefined ground truth for system evaluation. The reconstructed cross-sectional 2D images closely matched the known ground truth concentration, confirming the system’s high accuracy and reliability. The demonstrated system’s capabilities open doors for potential applications in environmental monitoring and industrial safety, though further testing is planned to ascertain the system’s operational boundaries fully.
This paper explores combining a gimbal-mounted tunable diode laser absorption spectroscopy (TDLAS) sensor and a video camera to create a virtual gas camera for methane leak detection. This provides a low-to-zero-cost extension of typical TDLAS gas tomography systems. A prototype setup mounted on a ground robot is evaluated. Results acquired using a simulated methane leak show the feasibility of the virtual gas camera, accurately detecting methane leaks by overlaying concentrations onto a visual image. While the acquisition time is significantly longer than for traditional gas cameras, potential enhancements are discussed. The study concludes that the virtual gas camera is feasible and useful, despite its longer acquisition time. It serves as a valuable software-only addition to typical TDLAS gas tomography systems, offering quickly-available on-site data augmentation for visual leak assessment at low-to-zero cost.
This paper outlines significant advancements in our previously developed aerial gas tomography system, now optimized to reconstruct 2D tomographic slices of gas plumes with enhanced precision in outdoor environments. The core of our system is an aerial robot equipped with a custom-built 3-axis aerial gimbal, a Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor for CH4 measurements, a laser rangefinder, and a wide-angle camera, combined with a state-of-the-art gas tomography algorithm. In real-world experiments, we sent the aerial robot along gate-shaped flight patterns over a semi-controlled environment with a static-like gas plume, providing a welldefined ground truth for system evaluation. The reconstructed cross-sectional 2D images closely matched the known ground truth concentration, confirming the system’s high accuracy and reliability. The demonstrated system’s capabilities open doors for potential applications in environmental monitoring and industrial safety, though further testing is planned to ascertain the system’s operational boundaries fully.
Digital Calibration Certificates: Transforming Efficiency and Safety in Hydrogen Refuelling Station
(2023)
Digital Certificates have emerged as a pivotal element in automation and digitalisation. This presentation highlights the added value of a digitalised metrology, its impact on the workflows on the calibration service providing and receiving side as well as their significance in enhancing the quality infrastructure. An overview of digital calibration certificates (DCC) for temperature sensors, including their structure and role in establishing trust in hydrogen refuelling stations (HRS), will be discussed. Additionally, it explores the impact of DCC on optimising efficiency in the hydrogen refuelling process.
Exploring the paradigm shift brought about by Industry 4.0, where machines possess the ability to autonomously interpret digital certificate data, leads to streamlined safety checks and reduced human intervention. We will discuss how automated verification of machine-readable certificates contributes to maintaining and elevating safety standards over human-readable certificates. Furthermore, we will take a deep dive into the application of DCCs in HRS, showcasing how they enhance operational efficiency, accuracy, and maintenance by enabling real-time monitoring and adjustment of process data.
By exploring the interdependent relationship between digital certificates, machine-readable environments, and HRS optimisation, this presentation will provide valuable insights into harnessing cutting-edge technologies to create a safer, more efficient, and technologically empowered hydrogen refuelling process.
Die Magnetpulverprüfung ist eine weit verbreitete Prüfmethode für ferromagnetische Bauteile. Hierbei werden Oberflächenfehler wie Risse mit ferromagnetischem Pulver sichtbar gemacht, wodurch eine qualitative Bewertung des Bauteils ermöglicht wird. Allerdings können die Anzeigen kaum zu einer quantitativen Bewertung herangezogen werden. Hierfür sind Magnetfeldsensoren nötig, die die Stärke der Streufelder messen, wodurch z. B. die Tiefe der Risse abgeschätzt werden kann. Bei kommerziellen Magnetfeldsensoren sind die sensitiven Elemente auf Platinen angebracht bzw. in eine Verkapselung integriert. Hierdurch erhöht sich der Abstand der Elemente zur Oberfläche und kleine Fehler können unter Umständen nicht mehr detektiert werden. Auch wird eine automatisierte Prüfung komplexer Geometrien durch die starren Sonden erschwert.
Um Streufelder von kleinen Fehlern in komplexen Bauteilen quantitativ bewerten zu können, validiert die BAM den Einsatz neuartiger, flexibler Magnetfeldsensoren. Hierbei sind die sensitiven Elemente auf flexiblen Folien aufgebracht und lassen sich verformen, wodurch sie auf viele mögliche Oberflächenformen appliziert werden können. Es wird ein geringerer Abstand der Elemente zur Oberfläche erreicht und Streufelder von kleinen Defekten können besser aufgelöst werden. Zudem verlieren die Sensoren durch Verformung weder ihre Sensitivität noch werden sie hierdurch zerstört. Dies macht diese Sensoren zu perfekten Kandidaten für die quantitative Bewertung von Rissstreufeldern in komplex geformten, ferromagnetischen Bauteilen.
Der Beitrag präsentiert die Charakterisierung der Sensoren sowie erste Versuche an komplexen Bauteilen. Schließlich wird eine Einschätzung hinsichtlich weiterer Anwendungsmöglichkeiten gegeben.
Es handelt sich hierbei um die erste Veröffentlichung einer verifizierbaren eAttestation (DCC mit DAkkS-Siegel). Sie wurde vom akkreditierten Kalibrierlabor D-K-11075-08, im Rahmen des QI-Digital Vorhabens, für den Fachbereich 8.1 erstellt und dient im Zusammenhang mit dem Vortrag "Digitale Kalibrierzertifikate – die Umsetzung in akkreditierten Laboratorien" auf dem 324. PTB-Seminar "Berechnung der Messunsicherheit – Empfehlungen für die Praxis" als Anschauungsmaterial für die Digitalisierung in der Metrologie.
Die PKI zum digitalen Akkreditierungssymbol der DAkkS sowie dessen Funktionsweise und daraus resultierende Mehrwerte für Kalibrierlaboratorien und Endanwender werden vorgestellt. Im Anschluss wird der aktuelle Stand bei der Einführung des digitalen Kalibrierscheins (DCC) im akkreditierten Kalibrierlabor der BAM wiedergegeben. Eine Roadmap für die Digitalisierung des Kalibrierlabors sowie die Vorstellung des Quality-X Konzeptes geben einen Ausblick in die nähere Zukunft.
In order to detect small and hidden material defects or micro-cracks, weak and localized magnetic stray fields need to be detected and characterized on the magnetic surface. Current flux leakage sensor elements are rigid and rely on air gaps to detect stray fields several hundred micrometers above the surface. Furthermore, the increasing complexity of critical components, enabled by novel fabrication technologies, primarily additive manufacturing, poses a significant challenge to the available flux leakage testing technologies.
The emergence of flexible magneto-electronics paves the way to a compliant form of magnetic sensors that, on one hand, are able to adapt to highly curved surfaces, allowing these measurements to be conducted on irregularly formed components, which are inaccessible for nowadays electromagnetic NDT equipment and, on the other hand, could enhance the detection limit for small magnetic stray fields, by allowing the magneto-sensitive elements to approximate the object’s surface until only a few µm, mediated by thin and flexible packaging.
The finite volume method (FVM), like the finite element method (FEM), is a numerical method for determining an approximate solution for partial differential equations. The derivation of the two methods is based on very different considerations, as they have historically evolved from two distinct engineering disciplines, namely solid mechanics and fluid mechanics. This makes FVM difficult to learn for someone familiar with FEM. In this paper we want to show that a slight modification of the FEM procedure leads to an alternative derivation of the FVM. Both numerical methods are starting from the same strong formulation of the problem represented by differential equations, which are only satisfied by their exact solution. For an approximation of the exact solution, the strong formulation must be converted to a so-called weak form. From here on, the two numerical methods differ. By appropriate choice of the trial function and the test function, we can obtain different numerical methods for solving the weak formulation of the problem. While typically in FEM the basis functions of the trial function and test function are identical, in FVM they are chosen differently. In this paper, we show which trial and test function must be chosen to derive the FVM alternatively: The trial function of the FVM is a “shifted” trial function of the FEM, where the nodal points are now located in the middle of an integration interval rather than at the ends. Moreover, the basis functions of the test function are no longer the same as those of the trial function as in the FEM, but are shown to be a constant equal to 1. This is demonstrated by the example of a 1D Poisson equation.
Nach einer kurzen Einführung in die Schallemissionsprüfung und -Analyse wird ein Versuchsstand vorgestellt, der im Rahmen des Themenfeldprojektes Seal Waste Safe installiert wurde. Schwerpunkt des Vortrages sind die Schallemissionsmessungen an einem 150 l Demonstrator aus Salzbeton und einem weiteren aus alkali-aktiviertem Material. Neben der konventionellen Schallemissionsanaylse mit Aktivitäts- und Intensitätsparametern der Zeitsignale, werden auch frequenzbasierte Parameter zur Analyse andiskutiert.
Intelligent sensor systems, certified reference materials and instrumental analytical-chemical methods contribute to safety and functionality in hydrogen technologies.
This article gives a brief overview of SensRef activities in the Competence Centre H2Safety@BAM on the issues: Analytical methods for the determination of hydrogen purity, certified reference materials as measurement standards with regard to gas quality (primary calibrators) of BAM, test methods for gas sensor systems to detect hydrogen in air as well as the application of fibre-optic sensor systems to monitor the expansion and ageing behaviour of composite containers in hydrogen technologies.
Der Vortrag zum Mess- und Prüfverfahren mit verschiedenen Sensortechnologien und Ultraschallwellen beinhaltet die Themen:
Metrologie zur Wasserstoffspeicherung - Euramet-Vorhaben "MefHySto",
Erkennung von freigesetztem Wasserstoff sowie die Bestimmung des Wasserstoff-Luftverhälntisses mit Gassensoren, zerstörungsfreie Fehlstellenerkennung mit integriertem Zustandsüberwachungssystem basierend auf geführten Ultraschallwellen zur Lebensdauerüberwachung von Composite-Behältern (Wasserstoffspeicher) sowie faseroptische Sensorik zur Schadenfrüherkennung von Wasserstoffspeichern aufgrund erkennbarer Dehnungsänderungen an Druckbehältern.
The determination of the measurement uncertainty of quantitative and qualitative results is an important quality management tool, for example to describe measuring equipment, procedures, measurement results and the quality of products. The lecture presents the process description for the determination of the measurement uncertainty according to GUM, the determination of uncertainties in qualitative measurement results and the application of the measurement uncertainty for conformity assessment.
Typically, the near-eutectic Al-Si alloys consist of highly interconnected three-dimensional network of the eutectic Silicon (Si) and intermetallics embedded into Aluminium (Al) matrix. For further improvement of the mechanical properties of such alloys, often, one single ceramic reinforcement phase, e.g. silicon carbide (SiC) or aluminium oxide (Al2O3) in the form of fibres or particles is added. However, hybrid reinforcements (fibres and particles) can further improve wear resistance and fracture toughness, and additionally, reduce anisotropy of the material. The engineering of metal matrix composites (MMC) for specific application requirements benefits from a comprehensive knowledge of the failure behaviour. Therefore, damage evolution under compression was investigated on:
- pure near-eutectic AlSi12CuMgNi matrix alloy
- type I: matrix reinforced with random-planar oriented Al2O3 short fibres (15 vol.%)
- type II: matrix reinforced with random-planar oriented Al2O3 short fibres (7 vol.%) and additional SiC particles (15 vol.%)
The analysis of damage mechanism was carried out in two rather independent but complementary studies. First, selected sister samples of every material were exposed to quasi-static compression (traverse control). The compression tests were interrupted at different strain levels. Miniature cylinders with a diameter of 1mm were extracted from the pre-strained samples and investigated by synchrotron computed tomography (SX-µCT) with a spatial resolution of about 0.7 µm. For the pure matrix alloy, microcracks are confined to the intermetallic particles and to the eutectic Si, hence no damage was observed in the Aluminium. The composite type II revealed a more effective strain accumulation (less damage) than type I at low plastic strain (up to 5 %), but a more catastrophic damage development due to cracking of the SiC clusters at higher strain levels.
The second approach to study the damage initiation and accumulation in the materials subjected to compressive load was Acoustic Emission (AE) analysis. In this case the in-situ monitoring of the acoustic emission signal was performed during compression tests on specimens with dimension of several mm. For all three material types, AE activity set at 2% strain. Differences in AE behaviour of the three materials was proven based on AE hitrate, signal peak amplitudes as well as weighted peak frequencies (WPF). Future work focuses on combination of AE and SX-µCT aiming for more detailed knowledge on damage mechanism of metal matrix composites.
Von den Zellulosefibrillen über die Zellwand und die Anordnung der Früh- und Spätholzzellen in einem Jahrring bis hin zum Balken von Natur aus ist Holz ein optimierter Hochleistungswerkstoff, der Handwerker, Architekten, Ingenieure und Wissenschaftler fasziniert und begeistert. Im digitalen Zeitalter werden neben Standard-Laborexperimenten zunehmend Modelle und Simulationen eingesetzt, um das Verhalten des Materials unter verschiedenen Belastungen besser zu verstehen und vorherzusagen. Dazu werden Zahlenwerte von Verformungen im subzellulären Maßstab benötigt, die nun in Experimenten an der TOMCAT-Beamline (TOmographic Microscopy and Coherent rAdiology ExperimenTs) der SLS (Swiss Light Source) gewonnen werden konnten: Holzproben aus Fichte ( Picea abies Karst.) mit einem Prüfquerschnitt von mindestens 1 mm² auf Zug oder Druck beansprucht. Die strukturellen Veränderungen auf Zellebene wurden mittels Computertomographie erfasst. Für die nachträgliche Analyse der 3D-Mikrostruktur von Holz wurde ein Ansatz entwickelt, der es ermöglicht, einzelne Zellen, die in mehreren Tomogrammen unterschiedlicher Belastungszustände erfasst wurden, zu verfolgen. Dabei wurden die Zellgeometrien und das subzelluläre Deformationsverhalten quantifiziert. Unter Zugbelastung beispielsweise verengt sich die Zellwanddicke um ca. 0,8%, das sind bei der gemessenen mittleren Zellwanddicke von 3,5 µm ca. 28 nm. Diese und andere Erkenntnisse liefern nun einen direkten numerischen Zusammenhang zwischen Verformungen der Holzmikrostruktur und dem daraus resultierenden makroskopischen Verhalten.
Von den Zellulosefibrillen über die Zellwand und die Anordnung der Früh- und Spätholzzellen in einem Jahrring bis hin zum Balken von Natur aus ist Holz ein optimierter Hochleistungswerkstoff, der Handwerker, Architekten, Ingenieure und Wissenschaftler fasziniert und begeistert. Im digitalen Zeitalter werden neben Standard-Laborexperimenten zunehmend Modelle und Simulationen eingesetzt, um das Verhalten des Materials unter verschiedenen Belastungen besser zu verstehen und vorherzusagen. Dazu werden Zahlenwerte von Verformungen im subzellulären Maßstab benötigt, die nun in Experimenten an der TOMCAT-Beamline (TOmographic Microscopy and Coherent rAdiology ExperimenTs) der SLS (Swiss Light Source) gewonnen werden konnten: Holzproben aus Fichte ( Picea abies Karst.) mit einem Prüfquerschnitt von mindestens 1 mm² auf Zug oder Druck beansprucht. Die strukturellen Veränderungen auf Zellebene wurden mittels Computertomographie erfasst. Für die nachträgliche Analyse der 3D-Mikrostruktur von Holz wurde ein Ansatz entwickelt, der es ermöglicht, einzelne Zellen, die in mehreren Tomogrammen unterschiedlicher Belastungszustände erfasst wurden, zu verfolgen. Dabei wurden die Zellgeometrien und das subzelluläre Deformationsverhalten quantifiziert. Unter Zugbelastung beispielsweise verengt sich die Zellwanddicke um ca. 0,8%, das sind bei der gemessenen mittleren Zellwanddicke von 3,5 µm ca. 28 nm. Diese und andere Erkenntnisse liefern nun einen direkten numerischen Zusammenhang zwischen Verformungen der Holzmikrostruktur und dem daraus resultierenden makroskopischen Verhalten.
Poor air quality, particularly in urban areas, causes various diseases and degrades living standards. Air Quality could be affected by emissions of odor, Volatile Organic Compounds (VOCs), and other gases. Therefore, assessment and monitoring of odorous air quality using sensitive, simple, rapid, accurate and portable tools is very important for public health. This study aimed to characterize odor emissions to detect malfunctions in facilities and to prevent air pollution and olfactory nuisance in the environment. A gas chromatographic method, in conjunction with sensorial analysis were performed for odorous air samples analysis collected from neighborhood of Meknes city (Morocco). Advanced multivariate statistical approaches, such as Principal Components Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to describe samples similarities. The electronic nose (e-nose) data processing exhibits a satisfactory discrimination between the odorous air samples. Twenty-four VOCs with known molecular formulas were identified with Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS). A validated Partial Least Square (PLS) model foresees good calibration between e-nose measurement and TD-GCMS analysis. The finding indicates that TD-GC–MS approach in conjunction with e-nose unit could be suitable tool for environmental measurement-based odor emissions.
In this study, nanoscopic particles of magnesium Fluoride (MgF2) and calcium fluoride (CaF2) also known as nano metal fluorides (NMFs), were evaluated for their potential to improve wood durability. Even though these fluorides are sparingly soluble, their synthesis in the form of nano-sized particles turns them into promising candidates for wood preservation. Their distinct property of low-water solubility is proposed to maintain long-lasting protection of treated wood by reducing the leaching of fluoride. Analytical methods were used to characterize the synthesized NMFs and their distribution in treated wood specimens. Transmission electron microscopy images showed that these fluoride particles are smaller than 10 nm. In nano metal fluoride (NMF) treated specimens, aggregates of these particles are uniformly distributed in the wood matrix as confirmed with scanning electron microscopy images and their corresponding energy-dispersive X-ray spectroscopy maps. The fluoride aggregates form a protective layer around the tracheid walls and block the bordered pits, thus reducing the possible flow path for water absorption into wood. This is reflected in the reduced swelling and increased hydrophobicity of wood treated with NMFs. The biocidal efficacy of NMFs was tested against brown-rot fungi (Coniophora puteanaand Rhodonia placenta), white-rot fungus (Trametes versicolor), and termites (Coptotermes formosanus). The fungal and termite tests were performed in accordance with the EN 113 (1996) and EN 117 (2012) standards, respectively. Prior to fungal tests, the NMF treated wood specimens were leached according to the EN 84 (1997)standard. Compared to untreated specimens, the NMF treated wood specimens have a higher resistance to decay caused by brown-rot fungi, white-rot fungus, and termites. Although all NMF treatments in wood reduce the mass loss caused by fungal decay, only the combined treatment of MgF2 and CaF2 has efficacy against both brown-rot fungi and white-rot fungus. Similarly, wood treated with the combined NMF formulation is the least susceptible to attack by C. formosanus.It is proposed that combining MgF2 and CaF2changes their overall solubility to promote the release of fluoride ions at the optimal concentration needed for biocidal efficacy against fungi and termites. In this thesis, it was proven that even after leaching, sufficient fluoride was present to protect NMF treated wood from fungal decay. This shows that NMFs are robust enough for above ground contact outdoor applications of wood, where permanent wetness cannot be avoided according to Use Class 3.2, as per the EN 335 (2013) standard. Also, they pose a low risk to human health and the environment because they are sparingly soluble. Since NMFs significantly reduce the decay of wood, the CO2 fixed in it will be retained for longer than in unpreserved wood. Overall, the novel results of this study show the potential of NMFs to increase the service life of building materials made from non-durable wood.
Ein Durchlaufkühler ist im Betrieb explodiert. Die zerborstenen Gehäuseteile aus Kunststoff führten zu einem Austreten der Kühlflüssigkeit am Betriebsort sowie zu einem Personenschaden mit Knalltrauma. Bei Funktionsprüfungen am beschädigten Gerät traten unerwartet, aber reproduzierbar Knalleffekte auf der Kupfer-Kühlschlange auf. Ein möglicher Mechanismus konnte im Labor durch Synthese von Kupferazid auf Kupferproben und Auslösung vergleichbarer Knalleffekte nachgestellt werden. Damit ist die Plausibilität des beschriebenen Schadensereignisses mit diesem oder einem ähnlich reagierenden Stoff belegt. Ein eindeutiger Nachweis darüber, dass beim aufgetretenen Schadensfall dieselbe chemische Reaktion stattgefunden hat ist nicht möglich, da die Belag-Überreste aus dem explodierten Kühlgerät für eine Analyse nicht mehr in ausreichender Menge verfügbar waren.
The applicability of three methods developed by finite element analysis (FEM) and proposed in the literature are studied on steel S355. Instrumented indentation tests using spherical indenters of radius 200 and 500 μ m are performed in the macro range at depths of more than 6 μ m. The results of the selected methods are compared with the tensile test. To evaluate the partially strongly varying results, the uncertainties of the calculated strain hardening exponent, n, and yield stress, Y, are estimated. Recommendations for an appropriated procedure of the indentation test are given. The machine compliance and the determination of the zero point of Depth play an essential role. If the certain conditions are considered, the instrumented indentation Tests can be used, in particular for investigations of specimens with inhomogeneous elastoplasticity.
Mess- und prüftechnische Verfahren sind zur Prozesskontrolle und Sicherheitsüberwachung in Wasserstofftechnologien von hoher Bedeutung. Typische Anwendungsgebiete von Sensoren sind Sicherheitsüberwachung, Leckdetektion und Prozesskontrolle. In diesem Beitrag werden Themen zur Erkennung von freigesetztem Wasserstoff sowie die Bestimmung des Wasserstoff-Luftverhältnisses mit Gassensoren, Fehlstellenerkennung mit geführten Ultraschallwellen zur Lebensdauerüberwachung (Structural Health Monitoring) von Wasserstoffspeichern sowie der Einsatz faseroptischer Sensoren zur Überwachung des Dehnungs- und Alterungsverhaltens sowie zur Schadensfrüherkennung von Wasserstoffspeichern vorgestellt.
High quality tubular products are essential to the oil and gas industry. Quality control during their production focuses on the non-destructive detection of surface defects. The structured light technique is a candidate for the challenge to detect, monitor and evaluate such defects in real-time.
In the present study the automatic processing of structured light measurements is performed and validated. The algorithm for the automatic Analysis of inspection data has an advantage over current data evaluation methods based on individual assessments of operators.
The evaluation of measurement uncertainty is essential for testing and calibration laboratories. This paper provides a general process description for the determination of the measurement uncertainty of quantitative data and its application to the conformity assessment with examples, and how to deal with the uncertainty of qualitative (Boolean) results, e. g. when "Alarm" or "No alarm" occours in an instrument display.
Wood-based composites hold the promise of sustainable construction. Understanding the influence on wood cellular microstructure in the macroscopic mechanical behavior is key for engineering highperformance composites. In this work, we report a novel Individual Cell Tracking (ICT) approach for in-situ quantification of nanometer-scale deformations of individual wood cells during mechanical loading of macroscopic millimeter-scale wood samples. Softwood samples containing > 104 cells were subjected to controlled radial tensile and longitudinal compressive load in a synchrotron radiation micro-computed tomography (SRμCT) setup. Tracheid and wood ray cells were automatically segmented, and their geometric variations were tracked during load. Finally, interactions between microstructure deformations (lumen geometry, cell wall thickness), cellular arrangement (annual growth rings, anisotropy, wood ray presence) with the macroscopic deformation response were investigated. The results provide cellular insight into macroscopic relations, such as anisotropic Poisson effects, and allow direct observation of previously suspected wood ray reinforcing effects.
The method is also appropriate for investigation of non-linear deformation effects, such as buckling and deformation recovery after failure, and gives insight into less studied aspects, such as changes in lumen diameter and cell wall thickness during uniaxial load. ICT provides an experimental tool for direct validation of hierarchical mechanical models on real biological composites.
Fluorides are well-known as wood preservatives. One of the limitations of fluoride-based wood preservatives is their high leachability. Alternative to current fluoride salts such as NaF used in wood protection are low water-soluble fluorides. However, impregnation of low water-soluble fluorides into wood poses a challenge. To address this challenge, low water-soluble fluorides like calcium fluoride (CaF2) and magnesium fluoride (MgF2) were synthesized as nanoparticles via the fluorolytic sol−gel synthesis and then impregnated into wood specimens. In this study, the toxicity of nano metal fluorides was assessed by termite mortality, mass loss and visual analysis of treated specimens after eight weeks of exposure to termites, Coptotermes formosanus. Nano metal fluorides with sol concentrations of 0.5 M and higher were found to be effective against termites resulting in 100% termite mortality and significantly inhibited termite feeding. Among the formulations tested, the least damage was found for specimens treated with combinations of CaF2 and MgF2 with an average mass loss less than 1% and visual rating of “1”. These results demonstrate the efficacy of low water-soluble nano metal fluorides to protect wood from termite attack.
Um die Versagensabläufe über die verschiedenen Skalen im Holzwerkstoff verfolgen zu können, werden Zugversuche an Lagenhölzern mittels Schallemissionsmessung überwacht. Synchron erfolgen In-situ-Messungen mit Digitaler Bildkorrelation bzw. Synchrotron-Mikro-Computertomographie. Die Kombination aller Ergebnisse wie auch die Anwendung der frequenzbasierten Mustererkennung und die Simulation ausgewählter Versuche zielen auf die Identifizierung zugrunde liegender Mechanismen hin. Abschließend werden Ansätze für ein Monitoring von Holzstrukturen diskutiert.
Over decades, the German Federal Institute for Materials Research and Testing (BAM) has established a sophisticated calibration laboratory for force, temperature and electrical quantities. Since more than 15 years it is accredited, currently by the national accreditation body (DAkkS), and offers its service also to external entities on a global scale. As a public provider, we are furthermore committed to research and development activities that demand measurements with highest quality and low level of uncertainties. Two R&D examples are highlighted within this contribution.
To better understanding the failure of adhesive joints tensile tests were carried out on miniature test specimens from Norway spruce in the synchrotron. Urea-formaldehyde resin was used as adhesive. e. For comparison purposes, tensile tests were carried out on solid wood and on bonded miniature tensile shear samples with acoustic emission. The acoustic emission signals of all the experiments occurred with classified pattern recognition. This resulted in two classes of signals for each two frequency peaks. One class consisted of the low-frequency and the other of the higher-frequency peak of higher intensity, but this was essentially independent from the structure (solid wood or plywood) and size scale of the test specimens. The influence of the adhesive layers was determined on wood test specimens on laboratory scale and on miniature test specimens with an adhesive layer and selected fiber orientations. This gave evidence that the sound emission signals from the failure of the adhesive layer presumably of the class with low frequency signals peak in the range of services can be assigned.
Der Mangel an Anwendungsrichtlinien und Validierungsverfahren für struktur-eingebettete faseroptische Dehnungssensoren, insbesondere auf Faser-Bragg-Gitter (FBG)-Basis, führte bislang dazu, dass diese Sensoren trotz ihrer hervorragenden Eigenschaften im Bereich der kommerziellen Material- und Strukturüberwachung nur in geringem Umfange eingesetzt wurden. Fragen zur Degradation der Sensoren unter Beanspruchung, Alterung durch klimatische Einflüsse und Enthaftung infolge Belastung der Struktur konnten bisher nur theoretisch simuliert oder anhand exemplarischer Proben für einzelne einflussnehmende Parameter im Labor untersucht werden. Die Erfassung des Sensorverhaltens im Bauteil unter komplexen Umwelteinflüssen während des Bauteilbetriebes, um damit eine Aussage zur Zuverlässigkeit der Sensormessdaten zu gewinnen, war bisher nicht möglich.
Im Forschungsprojekt FAMOS² wurde deshalb von 2014 bis 2018 die Realisierung eines Autodiagnoseverfahrens für faseroptische Dehnungssensoren erarbeitet, um die Funktionszuverlässigkeit und Langzeitstabilität der Sensoren während des Bauteilbetriebes innerhalb einer Bauteilstruktur bewerten zu können. Im Rahmen des Forschungsprojektes wurde gezeigt, dass ein FBG-Sensor mit einer speziell angepassten magnetostriktiven Schicht magnetisch so angeregt werden kann, dass mit einer zugeschnittenen Messmethodik zu jedem Zeitpunkt eine Bewertung der Sensorzuverlässigkeit unter Betriebsbedingungen möglich ist. Die auf den Sensor aufgebrachte magnetostriktive Schicht erzeugt bei Anregung mit einem passenden Magnetfeld eine gepulste, synthetische Dehnung. Diese Dehnung steht in einem definierten Verhältnis zum anregenden Magnetfeld und wird optisch über die Verschiebung der Bragg-Wellenlänge ausgelesen. Die Konstanz dieses Verhältnisses stellt dann ein Maß für die korrekte Funktionsfähigkeit des Sensors dar. Das Beschichtungs-verfahren, das magnetische Anregungs- und optische Ausleseverfahren, wie auch die Validierung des Sensors unter Berücksichtigung faseroptischer Effekte wurden während des Projekts konzeptionell entwickelt, aufgebaut und charakterisiert. Qualitativ kann mit diesem Verfahren zunächst eine Gut-/Schlecht-Beurteilung des Sensors vorgenommen werden. Perspektivisch bietet das Verfahren jedoch auch die Möglichkeit, verschiedene Versagensmechanismen bestimmen und klassifizieren zu können. Es zeichnete sich schon während des Projektverlaufs ab, dass sich aus den erzielten Ergebnissen über das Autodiagnoseverfahren hinaus weitere Anwendungsmöglichkeiten für den Einsatz des kombinierten magnetostriktiv-faseroptischen Sensorprinzips, beispielsweise als reiner Magnetfeldsensor, ergeben.
Nach Abschluss dieses Forschungsprojekts besteht nun die Möglichkeit, den Funktionszustand faseroptischer Dehnungssensoren jederzeit unabhängig von Alter, Belastung oder Kenntnis eines Referenzzustands zu einem bestimmten Zeitpunkt bestimmen zu können. Aufbauend auf diesen Ergebnissen können weiterführende Forschungen die Messmethodik vertiefend charakterisieren und weitere Anwendungsfälle erschließen.
In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures. The method is based on a ratiometric measurement principle, exploiting the pH sensitive colour switching of thymol blue in the basic pH regime and the emissive properties of two different (Zn)CdSe/ZnS core shell quantum dots. The transition point of thymol blue in a Hydrogel D4 matrix was determined to be at around pH 11.6, which fits ideally to the intended application. Next to the fundamental spectroscopic characterization of the ratiometric response, a new design for a sensor head, suitable for the incorporation into concrete matrices is presented. Toward this, a manufacturing process was developed which includes the preparation of a double layer of polymers containing either thymol blue or a quantum dot mixture inside a porous ceramic tube. Results of a proof-of-priciple performance test of the sensor head in solutions of different pH and in cement specimens are presented, with encouraging results paving the way for future field tests in concrete.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.
This paper describes the development of a semi-automatic gas measurement device presenting potentially a broad range of applications, noteworthy in the agricultural sector. Non-reversible fluorescent molecular sensors were designed and syn-thesized. Upon, integration into a hydrogel matrix with an optimal ratio of co-solvents, the sensors reacting selectively to ammonia were illuminated by excitation light to produce a concentration-correlated fluorescence emission. An automated mechanical-elec-trical device initiates a given gas mixture and thus simulates con-centrations similar to a threshold value. The aim of this project is to develop a sensor or a low-cost method which can monitor low concentrations of harmful gases and aid in their elimination or regulation in livestock housing, barns or stables.
Against the background of sustainable resource management and efficiency, wood-based materials are currently experiencing a revival and, among others, plywood, Laminated Veneer Lumber and glued laminated timber are becoming increasingly more important in the building sector. Even though these materials are so-called engineered products, the element wood is naturally grown with intrinsic variability in mechanical properties and requires professional handling on-site. Otherwise, load-bearing structures made of wood materials may entail certain risks. Critical situations can, in principle, be avoided by implementing a structural health monitoring system into components or structures made from wood material. The aim is to indicate accumulation of mechanical damage and to eliminate or at least significantly reduce the risk of unexpected failure. Toward this purpose, the failure behavior of several layered wood materials under quasi-static tension was investigated in laboratory-scale experiments by means of acoustic emission (AE) measurement. Based on spectral analysis and pattern recognition, two classes of AE signals are identified for each investigated lay-up that are characterized by either low or high frequency contents in the respective power spectra. AE activity and intensity of both signal classes are analyzed, striving for predictors appropriate for AE monitoring concepts.
Against the background of sustainable resource management and efficiency, wood-based materials are currently experiencing a revival and, among others, plywood, Laminated Veneer Lumber and glued laminated timber are becoming increasingly more important in the building sector. Even though these materials are so-called engineered products, the element wood is naturally grown with intrinsic variability in mechanical properties and requires professional handling on-site. Otherwise, load-bearing structures made of wood materials may entail certain risks. Critical situations can, in principle, be avoided by implementing a structural health monitoring system into components or structures made from wood material. The aim is to indicate accumulation of mechanical damage and to eliminate or at least significantly reduce the risk of unexpected failure. Toward this purpose, the failure behavior of several layered wood materials under quasi-static tension was investigated in laboratory-scale experiments by means of acoustic emission (AE) measurement. Based on spectral analysis and pattern recognition, two classes of AE signals are identified for each investigated lay-up that are characterized by either low or high frequency contents in the respective power spectra. AE activity and intensity of both signal classes are analyzed, striving for predictors appropriate for AE monitoring concepts.
Der Fokus des Arbeitsfelds ist die messtechnisch fundierte Anwendung der 3D-Verfahrenskombination zur Lösung vielfältiger Messaufgaben mit optimaler Datenqualität für interne und externe Kunden.
Das setzt insbesondere eine jeweils problembezogene Messmethodik voraus. Dazu setzen wir kameragestützte 3D-Koordinatenmessverfahren ein, die auf dem fotogrammetrischen Prinzip der Bildtriangulation beruhen. Darunter fallen folgende miteinander flexibel kombinierbare Verfahrensmodifikationen: Mehrbildfotogrammetrie, Messadapter für Geometriemerkmale, Streifenprojektionsverfahren, statische bis hochdynamische Stereofotogrammetrie auf Punktebasis oder aufgabenangepasster Oberflächenmuster und mechanisch-optische Taster.
Das Projekt befasst sich mit einem neuen Ansatz, den pH-Wert im Beton zu bestimmen.
Der pH-Wert ist vor allem für Stahlbeton-Bauwerke von Bedeutung, da dieser maßgeblich die Korrosion des Stahls beeinflusst. Im frischen Beton liegt der pH-Wert im basischen Bereich.
Der Stahl ist in diesem Bereich passiviert, also vor schädlicher Korrosion geschützt. Durch die sogenannte Karbonatisierung sinkt der pH-Wert und die Korrosionswahrscheinlichkeit steigt deutlich an. Die Stabilität von Bauwerken in denen Stahlbeton verbaut ist, wird durch diese Korrosion langfristig beeinträchtigt. Allein in deutscher Infrastruktur rechnet man mit circa 5 Milliarden Euro Schaden jährlich.
Die entwickelte Methode verwendet Sonden, welche die Korrosion Monitoren sollen. Im Sondeninneren befindet sich eine Schicht pH-Indikator (Thymolblau) und eine Schicht mit Quantenpunkten. Die Quantenpunkte fluoreszieren, nach Anregung durch zum Beispiel einen Laser, bei circa 440 nm (blau) beziehungsweise 610 nm (gelb-orange). Das Thymolblau ist im basischen Milieu (pH > 9,6) blau, im neutralen Milieu (um pH 7) gelb-orange. Der Indikator wirkt wie ein Farbfilter und lässt, je nach pH-Wert, unterschiedliche Wellenlängen zur Glasfaser durch. Aus der gemessenen Intensität bei 440 nm und 610 nm kann ein Verhältnis ermittelt werden. Dieses Verhältnis lässt erkennen, welchen pH-Wert das Milieu besitzt, in dem sich die Sonde befindet.
Die entwickelte Methodik ist zerstörungsfrei, das heißt kein Material muss aus den Bauwerken entnommen werden. Vielmehr sollen die Sonden beim Betonieren in das Bauwerk eingebettet werden. Über Glasfasern können die Sonden jederzeit angesprochen werden. Dies ermöglicht permanentes pH-Monitoring, was die Früherkennung von Korrosionsgefahr verbessert und die Sanierungskosten verringert.
Um ein tieferes Verständnis über die Schallemission bei der Entstehung und Ausbreitung von Rissen in Stahlrohrleitungen zu erlangen, wurde ein Stahlrohr der Güte S355J2H im Vierpunkt-Biegeversuch quasistatisch bis hin zum Wanddurchbruch (Leckage) belastet und mittels Schallemissionsmessung und Gleichstrompotentialmessung überwacht. Das Rohrsegment wurde durch einen 90°- Außenumfangskerb in der Mitte der Rohrlänge definiert vorgeschädigt, um davon ausgehend ein stabiles Risswachstum zu induzieren und die Analyse von Schallemission aus Rissereignissen, die am Kerb eintraten, sicherzustellen. Für die Schallemissionsmessung wurden vier Breitbandsensoren max. 105 mm vom Kerb entfernt montiert. Die Signalaufzeichnung erfolgte kontinuierlich und schwellwertunabhängig. Für die Gleichstrompotentialmessung wurde ein Gleichstrom von 300 A eingeleitet und der Potentialabfall über dem Kerb mit fünf Sonden entlang des Kerbs gemessen. Beide Messverfahren identifizieren die Rissinitiierung sowie Veränderungen im Risswachstum. Die detektierten Schallemissionsereignisse werden, unter Berücksichtigung spektraler Eigenschaften, mit fortschreitender Belastung und Rissentwicklung analysiert. Diese Studien wurden im Rahmen des interdisziplinären Forschungsprojekts AGIFAMOR, Aging infrastructure - Faseroptisches Monitoring von Rohrleitungen, an der BAM durchgeführt.
Um ein tieferes Verständnis über die Schallemission bei der Entstehung und Ausbreitung von Rissen in Stahlrohrleitungen zu erlangen, wurde ein Stahlrohr der Güte S355J2H im Vierpunkt-Biegeversuch quasistatisch bis hin zum Wanddurchbruch (Leckage) belastet und mittels Schallemissionsmessung und Gleichstrompotentialmessung überwacht. Das Rohrsegment wurde durch einen 90°- Außenumfangskerb in der Mitte der Rohrlänge definiert vorgeschädigt, um davon ausgehend ein stabiles Risswachstum zu induzieren und die Analyse von Schallemission aus Rissereignissen, die am Kerb eintraten, sicherzustellen. Für die Schallemissionsmessung wurden vier Breitbandsensoren max. 105 mm vom Kerb entfernt montiert. Die Signalaufzeichnung erfolgte kontinuierlich und schwellwertunabhängig. Für die Gleichstrompotentialmessung wurde ein Gleichstrom von 300 A eingeleitet und der Potentialabfall über dem Kerb mit fünf Sonden entlang des Kerbs gemessen. Beide Messverfahren identifizieren die Rissinitiierung sowie Veränderungen im Risswachstum. Die detektierten Schallemissionsereignisse werden, unter Berücksichtigung spektraler Eigenschaften, mit fortschreitender Belastung und Rissentwicklung analysiert. Diese Studien wurden im Rahmen des interdisziplinären Forschungsprojekts AGIFAMOR, Aging infrastructure - Faseroptisches Monitoring von Rohrleitungen, an der BAM durchgeführt.
The book chapter first analyses the history of higher education in Europe. Second step describes the current Bologna process. Finally, the rule of the Bundesanstalt für Materialforschung und -Prüfung (BAM) in supporting PhD-students during their research and preparation of theire theses in cooperation with Universities is described
The presented development of a damping model is a research component of an experimental feasibility study about moisture in building materials measured with Bluetooth® Low Energy (BLE) signals. This study may be part of a structural health- and long-term monitoring aiming at early damage detection in the built infrastructure and is increasingly focusing on wireless sensor network technology. It is investigated, how the Received Signal Strength Indicator (RSSI) of a BLE signal, transmitted from the BLE-module embedded in building materials with changing moisture content is damped. The aim of the modelling is the derivation of a damping equation for the formal model to determine the moisture damping exponent to finding a correlation.
Leaking methane (CH4) from infrastructures, like pipelines, industrial complexes and landfills, or accidental hazardous goods transports is critical for the environment, but can also pose a risk to human life. To enable a fast detection and localisation of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. The platform combines an unmanned micro aircraft (UAV), a 3-axis aerial stabilisation gimbal and an open-path gas detector based on the tunable diode laser absorption spectroscopy (TDLAS).
An unmanned micro aircraft (UAV) is equipped with an open-path gas detector to localise gas sources and to generate gas distribution maps. The gas detector is based on the tunable diode laser absorption spectroscopy (TDLAS) and attached to a 3-axis aerial stabilisation gimbal. Sensor validation experiments and first gas tomography reconstructions are shown.
Trace humidity was measured by using miniaturized planar coulometric sensors in technical gases such as hydrogen, nitrogen, helium, nitrous oxide, and synthetic air. Frost point temperatures tf in the gases ranged from −60 °C to −30 °C, which is equivalent to a vapour mole fraction xv from 10 μmol mol−1 to 376 μmol mol−1. In addition, the generated humidity was determined by using a precision dew point hygrometer as reference. Nonlinear calibration functions were calculated that correlated electric current (sensor signal) and reference humidity. Parameters of functions were tested with one-way analysis of variances (ANOVA) to prove if all used sensors had a similar behavior in the same gas during experiments. Results of ANOVA confirmed that averaged functions can be applied for trace humidity measurement in nitrogen, helium, nitrous oxide, and synthetic air. The calculated functions were negligibly different for nitrogen, helium, and synthetic air. In humidified nitrous oxide, a minor change of parameters was observed due to lower electrical currents. In total contrast to that, the measured sensor signals were significantly higher in humidified hydrogen and each sensor required its own calibration function. The reason was a recombination effect that favoured multiple measurements of water molecules. Nevertheless, it was possible to measure continuously trace humidity in all tested gases by using coulometric sensors with an expanded uncertainty below 2 K (k = 2).
Fluorometric sensing is a versatile approach for trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them as superior active component for the preparation of optical sensing devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents, illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications.
In the interdisciplinary project presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable. The dyes presented follow a “turn-on” fluorescence schematic, which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing. Further steps in the project include the assembly of instruments for test-atmosphere generation, the referencing of the sensor system, development and implementation of an optical setup, and the testing of the prototype device under laboratory conditions and in the field.
In this presentation, we give an overview over the recent developments on this topic in our groups. Highlights are hydrogen sulfide sensitive, BODIPY based transition metal complexes, which allow for a sensitive as well as selective detection of the toxic gas. In addition, we present a novel class of highly substituted BODIPY derivatives – pocket-BODIPYs – which are of a synthetically high versatility and can readily be modified to create pockets in the periphery of the molecule of defined geometries. This is illustrated on the successful encapsulation of benzene by a pocket-BODIPY derivative, confirmed by X-ray crystallographic analysis as well as by further spectroscopic and analytical methods.
Fluorometric sensing is a versatile approach for trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them as superior active component for the preparation of optical sensor devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents,illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications.
In the interdisciplinary approach presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable.
The dyes presented follow a “turn-on” fluorescence schematic, which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing. Further steps in the project include the assembly of instruments for test-atmosphere generation, the referencing of the sensor system, development and implementation of an optical setup, and the testing of the prototype device under laboratory conditions and in the field.
In this presentation, we give an overview over the recent developments on this topic in our groups, including fluorophore designs investigated for the detection of benzene, ammonia, and hydrogen sulfide as well as approaches for the design of the sensing device.
This work reported the investigation on the effect of relaxation to the permittivity (epsilon' r ) characteristic of Mg1-x Zn x TiO3 ceramics for x = 0 – 0.5 (MZT0 – MZT0.5) measured from 1 Hz to 330 MHz. Within that frequency range, the relaxation effect that consists of the space charge (SC) and the dipolar (D) polarization mechanisms were identified. The contribution of the D relaxation in MZT0 – MZT0.2 systems extents overall from about 100 Hz to 330 MHz, while that in MZT0.3 – MZT0.5 systems is from 50 kHz to 330 MHz. The remaining frequencies, i.e. from 1 to 90 Hz for MZT0 – MZT0.2 and from 1 Hz to 50 kHz for MZT0.3 – MZT0.5, are attributed to the SC relaxation. The D polarization mechanism provides constant epsilon' r values which vary from (15.4 – 17.0) ± 0.3 throughout the samples. Contribution of the SC polarization mechanism to the characteristic is supported by the simultaneous presence of different content and level of resistivity of the secondary phase of (Mg1-αZnα)2TiO4 in MZT0 – MZT0.2 systems and of (Zn1-αMgα)2TiO4 in MZT0.3 – MZT0.5, along with the presence of the main Mg1-x Zn x TiO3 phase, as a result of the variation of zinc content in the systems.
Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors.
Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors.
Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren
(2018)
Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales.
Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren
(2018)
Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales.
Acoustic emission testing
(2018)
Die Spurenfeuchte ist eine wichtige Messgröße bei der Qualitätsbeurteilung von technischen und medizinischen Gasen und muss daher zuverlässig gemessen werden. Der Spurenbereich ist definiert durch einen Wasserdampf-Stoffmengenanteil kleiner als 2600 µmol/mol bzw. einer Frostpunkttemperatur kleiner -10 °C. Eine geeignete Methode für die kontinuierliche Spurenfeuchtemessung stellt das Elektrolyseverfahren bzw. coulometrische Messprinzip dar. Bei diesem Prinzip strömt ein feuchtes Gas über eine hygroskopische Phosphorpentoxid-Schicht, welche kontinuierlich Wasserdampf absorbiert. Durch das Anlegen einer Zersetzungsspannung wird das absorbierte Wasser elektrolysiert und der resultierende Elektrolysestrom korreliert zum Feuchtegehalt im Gas. Neben dem Einfluss von unterschiedlichen Gasen auf das Messverfahren, wurde der Einfluss der Druckfeuchte im Druckbereich von 2 bis 15 bar untersucht. Des Weiteren wurde eine neuartige Sensorbeschichtung basierend auf einer ionischen Flüssigkeit getestet und es wurde ein Prototyp für die abgestufte Bestimmung der Wasseraktivität und der Materialfeuchte aufgebaut.
Multi-functional coatings are a key requirement for surface engineering. General demands are adhesion and long-term stability under service conditions. The modification of surfaces by means of PVD-, ECD- or hybrid processes allows an add-on functionalization of surfaces by a huge diversity of materials with both lateral and vertical micro-/nano-designs. This fact is a prerequisite for micro- and sensor-systems in lab-on-chip and sensor-on-chip technology. Two layer-based sensor principles are presented, i.e. surface plasmon resonance enhanced spectroscopic ellipsometry (SPREE) for detection of hazardous gases and magneto-optical sensors on smart-coated fiber Bragg gratings (FBG) for structural health monitoring (SHM).
The interdependence of substrate features, coating properties, and layer design is discussed firstly for gas sensitivity and selectivity of SPREE-sensors and secondly for sensitivity and selectivity of magneto-strictive coatings to mechanical strain or external magnetic fields resulting in an optical displacement of the Bragg wavelength of FBG-sensors. Moreover, generic features such long-term stability, crucial process-related fabrication conditions, and effects of operational and environmental parameters are discussed with respect to the sensor performance. It has been shown that appropriate layer design and adapted selection of layer materials (SnOx/Au, Fe/Ni:SnOx/Au; Ni/NiFe-Cu-Cr) result in improved sensor parameters and may enable new sensor applications.
Wood treated with nano metal fluorides is found to resist fungal decay. Sol−gel synthesis was used to synthesize MgF2 and CaF2 nanoparticles. Electron microscopy images confirmed the localization of MgF2 and CaF2 nanoparticles in wood. Efficacy of nano metal fluoride-treated wood was tested against brown-rot fungi Coniophora puteana and Rhodonia placenta. Untreated wood specimens had higher
mass losses (∼30%) compared to treated specimens, which had average mass loss of 2% against C. puteana and 14% against R. placenta, respectively. Nano metal fluorides provide a viable alternative to current wood preservatives.