Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2018 (657) (entfernen)
Dokumenttyp
- Vortrag (250)
- Zeitschriftenartikel (201)
- Posterpräsentation (140)
- Beitrag zu einem Tagungsband (42)
- Sonstiges (10)
- Buchkapitel (7)
- Dissertation (3)
- Forschungsdatensatz (2)
- Beitrag zu einem Sammelband (1)
- Forschungsbericht (1)
Sprache
- Englisch (657) (entfernen)
Schlagworte
- Concrete (33)
- Nanoparticles (31)
- LIBS (29)
- Fluorescence (26)
- Nanoparticle (25)
- XPS (19)
- Mechanochemistry (18)
- Thermography (16)
- Ultrasound (16)
- Laser ablation (15)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (237)
- 6 Materialchemie (217)
- 8 Zerstörungsfreie Prüfung (174)
- 6.1 Oberflächen- und Dünnschichtanalyse (88)
- 6.3 Strukturanalytik (69)
- 1.1 Anorganische Spurenanalytik (64)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (57)
- 8.0 Abteilungsleitung und andere (51)
- 4 Material und Umwelt (45)
- 1.2 Biophotonik (40)
Eingeladener Vortrag
- nein (250)
Raw data from metabolomics experiments are initially subjected to peak identification and signal deconvolution to generate raw data matrices m × n, where m are samples and n are metabolites. We describe here simple statistical procedures on such multivariate data matrices, all provided as functions in the programming environment R, useful to normalize data, detect biomarkers, and perform sample classification.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which require excessive calibration effort. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environ¬ments for advanced process monitoring and control, as demonstrated within the European Union’s Horizon 2020 project CONSENS.
We present a range of approaches for the automated spectra analysis moving from conventional multivariate statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants or derivatives and robust automation schemes.
A systematic study of the luminescence properties of monodisperse β-NaYF4: 20% Yb3+, 2% Er3+ upconversion nanoparticles (UCNPs) with sizes ranging from 12–43 nm is presented utilizing steady-state and time-resolved fluorometry.
Special emphasis was dedicated to the absolute quantification of size- and environment-induced quenching of upconversion luminescence (UCL) by highenergy O–H and C–H vibrations from solvent and ligand molecules at different excitation power densities (P). In this context, the still-debated Population pathways of the 4F9/2 energy level of Er3+ were examined. Our results highlight the potential of particle size and P value for color tuning based on the pronounced near-infrared emission of 12 nm UCNPs, which outweighs the red Er3+ emission under “strongly quenched” conditions and accounts for over 50% of total UCL in water. Because current rate equation models do not include such emissions, the suitability of these models for accurately simulating all (de)population pathways of small UCNPs must be critically assessed. Furthermore, we postulate population pathways for the 4F9/2 energy level of Er3+, which correlate with the size-, environment-, and P-dependent quenching states of the higher Er3+ energy levels.
Cerro do Jarau is a conspicuous, circular morpho‐structural feature in Rio Grande do Sul State (Brazil), with a central elevated core in the otherwise flat “Pampas” terrain typical for the border regions between Brazil and Uruguay. The structure has a diameter of approximately 13.5 km. It is centered at 30o12′S and 56o32′W and was formed on basaltic flows of the Cretaceous Serra Geral Formation, which is part of the Paraná‐Etendeka Large Igneous Province (LIP), and in sandstones of the Botucatu and Guará formations. The structure was first spotted on aerial photographs in the 1960s. Ever since, its origin has been debated, sometimes in terms of an endogenous (igneous) origin, sometimes as the result of an exogenous (meteorite impact) event. In recent years, a number of studies have been conducted in order to investigate its nature and origin. Although the results have indicated a possible impact origin, no conclusive evidence could be produced. The interpretation of an impact origin was mostly based on the morphological characteristics of the structure; geophysical data; as well as the occurrence of different breccia types; extensive deformation/silicification of the rocks within the structure, in particular the sandstones; and also on the widespread occurrence of low‐pressure deformation features, including some planar fractures (PFs). A detailed optical microscopic analysis of samples collected during a number of field campaigns since 2007 resulted in the disclosure of a large number of quartz grains from sandstone and monomict arenite breccia from the central part of the structure with PFs and feather features (FFs), as well as a number of quartz grains exhibiting planar deformation features (PDFs). While most of these latter grains only carry a single set of PDFs, we have observed several with two sets, and one grain with three sets of PDFs. Consequently, we here propose Cerro do Jarau as the seventh confirmed impact structure in Brazil. Cerro do Jarau, together with Vargeão Dome (Santa Catalina state) and Vista Alegre (Paraná State), is one of very few impact structures on Earth formed in basaltic rocks.
The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. We demonstrate this by imaging a line pattern and a star-shaped structure through a metal sheet with a resolution four times better than the width of the thermal point-spread-function. The ground-breaking concept of super-resolution can be transferred from optics to diffusive imaging by defining a thermal point-spread-function similar to the Abbe limit for a certain optical wavelength.
The detection of cracks before the failure is highly significant when it comes to safety-relevant structures. Crack detection in metallic samples at high surface temperature is one of the challenging situation in manufacturing industries.
Laser thermography has already proved its detection capability of surface cracks in metallic samples at room temperature. In this work a continuous wave (CW) laser use to generate a laser, which is using to scan the metal surface with notch.
The corresponding heat distribution on the surface monitored using infrared thermal (IR) camera. A simplified 3D model for laser thermography is developed and validated with experimental results. A dedicated image processing algorithm developed to improve the detectability of the cracks. To understand the dependency of surface temperature, laser power, laser scanning speed etc. in defect detection, we carried out parametric studies with our validated model. Here we Report the capability of laser thermography in crack detection at elevated temperature.
X-ray fluorescence analysis, due to its non-destructive nature and ist suitability to work with historic objects in situ, quickly became one of the most important methods for the evaluation of iron-gall ink. The main advantage of this qualitative and semi-quantitative method is that it makes it easy to differentiate between inks, based on the assumption that the differences result from the manufacture of the ink.
This work explores the question whether the ink ‘fingerprint’ results strictly from the elemental composition of the basic ink ingredients even if it is stored in vessels made of metals or metal alloys. In addition, we tested and compared the performance of three different XRF spectrometers.
We prepared various lab-grade inks according to historical ink recipes and measured the metal content of the ink deposited on sized cotton Linters paper with three types of XRF spectrometers: a simple hand-held device with an interaction spot of 4 mm and two devices equipped with poly-capillary Xray optics for line scanning and imaging. Since the exact elemental mass composition of the non-aged ink samples was known, we were able to evaluate the accuracy of the research procedure. Lab-grade inks were then aged in the metal jars imitating inkwells. The aging of the inks in the metal containers resulted in the significant change of the primary inks fingerprint as opposed to that of the control inks stored in glass containers. This effect was independently confirmed by the measurements conducted with every instrument we used. We will present a brief comparison of the results 43 achieved when using different spectrometers and a possible hypothesis explaining the processes that occurred.
We examine the behavior of reinforced concrete components subjected to impact induced loading conditions which might be caused by vessels collisions such as aircraft fuel tanks The concrete plates were impact damaged at TU Dresden and shipped to BAM At BAM laminar tomography as the imaging method is used to determine and quantify the damage state An automatic crack detection method based on template matching is applied to find the cracks and we aim to develop a new method using machine learning Algorithms In addition numerical models are developed to understand the experiment and to predict the damage structures based on failure mechanisms.