Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2018 (8) (entfernen)
Dokumenttyp
- Buchkapitel (8) (entfernen)
Schlagworte
- Aqueous phase of cement paste (1)
- Archäometrie (1)
- BAM (1)
- Bologna process (1)
- Broadband dielectric spectroscopy (1)
- Computed radiography (1)
- Depth information (1)
- Digital detector arrays (1)
- Discotic liquid crystals (1)
- Distributed sensor (1)
Organisationseinheit der BAM
- 6 Materialchemie (3)
- 8 Zerstörungsfreie Prüfung (3)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 4 Material und Umwelt (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 7 Bauwerkssicherheit (1)
- 7.4 Baustofftechnologie (1)
The book chapter first analyses the history of higher education in Europe. Second step describes the current Bologna process. Finally, the rule of the Bundesanstalt für Materialforschung und -Prüfung (BAM) in supporting PhD-students during their research and preparation of theire theses in cooperation with Universities is described
The paper presents rheometric results and hydration curves for cementitious systems based on cement mixed with different aqueous phases at solid volume fraction of = 0.45. The varied aqueous phases were deionized water, limewater, the filter residue of a cement paste mixed at w/c = 2.0, and the filtrate of cement paste at solid volume fraction of 0.45. Each cementitious system provided different amounts and sizes of particles formed in the aqueous phase. The pastes were observed with and without polycarboxylate ether based superplasticizer. It was observed that the presence of particles causes higher PCE saturation dosages to achieve a minimum value, but the minimum value is only affected in the case of large particles. In all cases with and without PCE, the presence of small particles causes increased plastic viscosity. In addition, with decreased number and size of hydrates in the aqueous phase the hydration was retarded, which was specifically pronounced in the presence of PCE
In Goethes naturwissenschaftlichen Sammlungen, die als Arbeits- und Studiensammlungen, zum Teil aber auch als Lehrsammlung für den Sohn August angelegt sind, haben sich sowohl die eigentlichen Sammlungsobjekte als auch deren vermeintlich ursprünglichen Kontexte durch Beschriftungen, Etiketten und in Teilen noch existierende Präsentationsmedien erhalten. Es stellt sich jedoch die grundsätzliche Frage nach deren Ursprünglichkeit. Präsentieren sich die Objekte noch so wie zur Goethezeit oder erfuhren die historischen Dichotomien im Laufe der Zeit Veränderungen, sodass die zeitgenössischen Präsentationsformen und die damit verbundenen didaktischen Funktionen heute nicht mehr lesbar sind?
This chapter gives an overview about polymer optical fiber (POF) sensors with the focus on structural and civil engineering applications. POF properties such as the high-strain range, the low Young’s modulus, and specific scattering effects open new fields for fiber-optic sensing applications. POF properties, sensitivities, and cross-sensitivities that are relevant for sensing are introduced. Advantages and limitations are discussed. State-of-the-art POF sensors and application examples are presented in subsections with regard to their underlying measurement principles.
A combination of different complementary methods is employed to investigate scaling of the molecular dynamics of two different liquid crystals. Each method is sensitive to different kind of fluctuations and provides therefore a different window to look at the molecular dynamics. In detail, broadband dielectric spectroscopy is combined with specific heat spectroscopy and neutron scattering. As systems the nematic liquid crystal E7 and a discotic liquid crystalline pyrene are considered. First of all it was proven that both systems show all peculiarities which are characteristic for glassy dynamics and the glassy state. Especially for the nematic liquid crystal E7 it could be unambiguously shown by a combination of dielectric and specific heat spectroscopy that the tumbling mode is the underlying motional process responsible for glassy dynamics. Dielectric investigations on the discotic liquid crystalline pyrene reveal that at the phase transition from the plastic crystalline to the hexagonal columnar liquid crystalline phase the molecular dynamics changes from a more strong to fragile temperature dependence of the relaxation rates. Moreover a combination of results obtained by specific heat spectroscopy with structural methods allows an estimation of the length scale relevant for the glass transition.
Raw data from metabolomics experiments are initially subjected to peak identification and signal deconvolution to generate raw data matrices m × n, where m are samples and n are metabolites. We describe here simple statistical procedures on such multivariate data matrices, all provided as functions in the programming environment R, useful to normalize data, detect biomarkers, and perform sample classification.
Heterogeneous catalysis is a key technology in modern industrial societies. The main steps of a catalytic process take place at the surfaces of complex materials. For the investigations of these surfaces X-ray photoelectron spectroscopy is widely used and fits ideally. At some suitable examples, it will be explained how XPS can help to understand such catalysts better. The focus is on selective oxidation catalysts, one of the main challenges of present research. Here it will illustrate, how changes in the near surface region influence the catalyst performance and, herewith the different stages (activation, maximum performance and deactivation) in the life of catalysts. Additionally, it will be stressed out how important information at different depth regions (surface, near-surface region, bulk) can be useful for comprehensive understanding of the material.
Another important subject is nanostructured catalysts with molecular sieves as supports or defined complexes as precursors. Finally, the combination of XPS with other methods used in the analysis of catalysts, e.g. electron microscopy, X-ray absorption spectroscopy and low energy ion scattering will be discussed.
Industrial Radiology is used for volumetric inspection of industrial objects. By penetration of these objects (typically weldments, pipes or castings) with X-ray or Gamma radiation the 3D-volume is projected onto a 2D image detector. The X-ray film is the oldest radiographic image detector and still in wide use in industry. The industrial X-ray film systems used today differ from these used in medicine. Medical film systems are described well in the literature, but industrial film systems not. So we start with a description of the properties and standards for industrial film systems. The requirements on image quality are defined by several standards and can be verified with different image quality indicators (IQIs). They describe the ability of the human being to detect small and low contrast indications in a noisy image background. The essential parameters for digital industrial radiology are described.
Since about 30 years electronic image detectors are gradually replacing the industrial film. These detectors are based on storage phosphor imaging plates in combination with Laser scanners (“Computed Radiography”, CR) or a variety of different digital detector arrays (DDA). Typical applications of CR and DDAs are discussed as well as new possibilities by digital image processing, which is enabled by the computer based image handling, processing and analysis.