Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Vortrag (24)
- Zeitschriftenartikel (12)
- Beitrag zu einem Tagungsband (7)
- Posterpräsentation (7)
- Buchkapitel (1)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
- Sonstiges (1)
- Forschungsbericht (1)
Sprache
- Englisch (34)
- Deutsch (20)
- Mehrsprachig (1)
Schlagworte
- Wood materials (4)
- Acoustic emission (3)
- Coulometric sensors (3)
- Elektrolyseverfahren (3)
- Gas Source Localisation (3)
- Gas Spectroscopy (3)
- Individual cell tracking (3)
- Measurement uncertainty (3)
- QI-Digital (3)
- Schallemission (3)
Organisationseinheit der BAM
- 8.1 Sensorik, mess- und prüftechnische Verfahren (55) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (24)
Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren
(2018)
Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales.
Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren
(2018)
Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales.
Multi-functional coatings are a key requirement for surface engineering. General demands are adhesion and long-term stability under service conditions. The modification of surfaces by means of PVD-, ECD- or hybrid processes allows an add-on functionalization of surfaces by a huge diversity of materials with both lateral and vertical micro-/nano-designs. This fact is a prerequisite for micro- and sensor-systems in lab-on-chip and sensor-on-chip technology. Two layer-based sensor principles are presented, i.e. surface plasmon resonance enhanced spectroscopic ellipsometry (SPREE) for detection of hazardous gases and magneto-optical sensors on smart-coated fiber Bragg gratings (FBG) for structural health monitoring (SHM).
The interdependence of substrate features, coating properties, and layer design is discussed firstly for gas sensitivity and selectivity of SPREE-sensors and secondly for sensitivity and selectivity of magneto-strictive coatings to mechanical strain or external magnetic fields resulting in an optical displacement of the Bragg wavelength of FBG-sensors. Moreover, generic features such long-term stability, crucial process-related fabrication conditions, and effects of operational and environmental parameters are discussed with respect to the sensor performance. It has been shown that appropriate layer design and adapted selection of layer materials (SnOx/Au, Fe/Ni:SnOx/Au; Ni/NiFe-Cu-Cr) result in improved sensor parameters and may enable new sensor applications.
Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors.
Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors.
This work reported the investigation on the effect of relaxation to the permittivity (epsilon' r ) characteristic of Mg1-x Zn x TiO3 ceramics for x = 0 – 0.5 (MZT0 – MZT0.5) measured from 1 Hz to 330 MHz. Within that frequency range, the relaxation effect that consists of the space charge (SC) and the dipolar (D) polarization mechanisms were identified. The contribution of the D relaxation in MZT0 – MZT0.2 systems extents overall from about 100 Hz to 330 MHz, while that in MZT0.3 – MZT0.5 systems is from 50 kHz to 330 MHz. The remaining frequencies, i.e. from 1 to 90 Hz for MZT0 – MZT0.2 and from 1 Hz to 50 kHz for MZT0.3 – MZT0.5, are attributed to the SC relaxation. The D polarization mechanism provides constant epsilon' r values which vary from (15.4 – 17.0) ± 0.3 throughout the samples. Contribution of the SC polarization mechanism to the characteristic is supported by the simultaneous presence of different content and level of resistivity of the secondary phase of (Mg1-αZnα)2TiO4 in MZT0 – MZT0.2 systems and of (Zn1-αMgα)2TiO4 in MZT0.3 – MZT0.5, along with the presence of the main Mg1-x Zn x TiO3 phase, as a result of the variation of zinc content in the systems.
Die Spurenfeuchte ist eine wichtige Messgröße bei der Qualitätsbeurteilung von technischen und medizinischen Gasen und muss daher zuverlässig gemessen werden. Der Spurenbereich ist definiert durch einen Wasserdampf-Stoffmengenanteil kleiner als 2600 µmol/mol bzw. einer Frostpunkttemperatur kleiner -10 °C. Eine geeignete Methode für die kontinuierliche Spurenfeuchtemessung stellt das Elektrolyseverfahren bzw. coulometrische Messprinzip dar. Bei diesem Prinzip strömt ein feuchtes Gas über eine hygroskopische Phosphorpentoxid-Schicht, welche kontinuierlich Wasserdampf absorbiert. Durch das Anlegen einer Zersetzungsspannung wird das absorbierte Wasser elektrolysiert und der resultierende Elektrolysestrom korreliert zum Feuchtegehalt im Gas. Neben dem Einfluss von unterschiedlichen Gasen auf das Messverfahren, wurde der Einfluss der Druckfeuchte im Druckbereich von 2 bis 15 bar untersucht. Des Weiteren wurde eine neuartige Sensorbeschichtung basierend auf einer ionischen Flüssigkeit getestet und es wurde ein Prototyp für die abgestufte Bestimmung der Wasseraktivität und der Materialfeuchte aufgebaut.
Acoustic emission testing
(2018)
Der Mangel an Anwendungsrichtlinien und Validierungsverfahren für struktur-eingebettete faseroptische Dehnungssensoren, insbesondere auf Faser-Bragg-Gitter (FBG)-Basis, führte bislang dazu, dass diese Sensoren trotz ihrer hervorragenden Eigenschaften im Bereich der kommerziellen Material- und Strukturüberwachung nur in geringem Umfange eingesetzt wurden. Fragen zur Degradation der Sensoren unter Beanspruchung, Alterung durch klimatische Einflüsse und Enthaftung infolge Belastung der Struktur konnten bisher nur theoretisch simuliert oder anhand exemplarischer Proben für einzelne einflussnehmende Parameter im Labor untersucht werden. Die Erfassung des Sensorverhaltens im Bauteil unter komplexen Umwelteinflüssen während des Bauteilbetriebes, um damit eine Aussage zur Zuverlässigkeit der Sensormessdaten zu gewinnen, war bisher nicht möglich.
Im Forschungsprojekt FAMOS² wurde deshalb von 2014 bis 2018 die Realisierung eines Autodiagnoseverfahrens für faseroptische Dehnungssensoren erarbeitet, um die Funktionszuverlässigkeit und Langzeitstabilität der Sensoren während des Bauteilbetriebes innerhalb einer Bauteilstruktur bewerten zu können. Im Rahmen des Forschungsprojektes wurde gezeigt, dass ein FBG-Sensor mit einer speziell angepassten magnetostriktiven Schicht magnetisch so angeregt werden kann, dass mit einer zugeschnittenen Messmethodik zu jedem Zeitpunkt eine Bewertung der Sensorzuverlässigkeit unter Betriebsbedingungen möglich ist. Die auf den Sensor aufgebrachte magnetostriktive Schicht erzeugt bei Anregung mit einem passenden Magnetfeld eine gepulste, synthetische Dehnung. Diese Dehnung steht in einem definierten Verhältnis zum anregenden Magnetfeld und wird optisch über die Verschiebung der Bragg-Wellenlänge ausgelesen. Die Konstanz dieses Verhältnisses stellt dann ein Maß für die korrekte Funktionsfähigkeit des Sensors dar. Das Beschichtungs-verfahren, das magnetische Anregungs- und optische Ausleseverfahren, wie auch die Validierung des Sensors unter Berücksichtigung faseroptischer Effekte wurden während des Projekts konzeptionell entwickelt, aufgebaut und charakterisiert. Qualitativ kann mit diesem Verfahren zunächst eine Gut-/Schlecht-Beurteilung des Sensors vorgenommen werden. Perspektivisch bietet das Verfahren jedoch auch die Möglichkeit, verschiedene Versagensmechanismen bestimmen und klassifizieren zu können. Es zeichnete sich schon während des Projektverlaufs ab, dass sich aus den erzielten Ergebnissen über das Autodiagnoseverfahren hinaus weitere Anwendungsmöglichkeiten für den Einsatz des kombinierten magnetostriktiv-faseroptischen Sensorprinzips, beispielsweise als reiner Magnetfeldsensor, ergeben.
Nach Abschluss dieses Forschungsprojekts besteht nun die Möglichkeit, den Funktionszustand faseroptischer Dehnungssensoren jederzeit unabhängig von Alter, Belastung oder Kenntnis eines Referenzzustands zu einem bestimmten Zeitpunkt bestimmen zu können. Aufbauend auf diesen Ergebnissen können weiterführende Forschungen die Messmethodik vertiefend charakterisieren und weitere Anwendungsfälle erschließen.