Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (3)
- Vortrag (2)
- Posterpräsentation (1)
Sprache
- Englisch (6)
Schlagworte
- Molecularly imprinted polymers (6) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (2)
Small-molecule oxoanions are often imprinted noncovalently as carboxylates into molecularly imprinted polymers (MIPs), requiring the use of an organic counterion. Popular species are either pentamethylpiperidine (PMP) as a protonatable cation or tetraalkylammonium (TXA) ions as permanent cations. The present work explores the influence of the TXA as a function of their alkyl chain length, from methyl to octyl, using UV/vis absorption, fluorescence titrations, and HPLC as well as MD simulations. Protected phenylalanines (Z-L/D-Phe) served as templates/analytes. While the influence of the counterion on the complex stability constants and anion-induced spectral changes shows a monotonous trend with increasing alkyl chain length at the prepolymerization stage, the cross-imprinting/rebinding studies showed a unique pattern that suggested the presence of adaptive cavities in the MIP matrix, related to the concept of induced fit of enzyme−substrate interaction. Larger cavities formed in the presence of larger counterions can take up pairs of Z-X-Phe and smaller TXA, eventually escaping spectroscopic detection. Correlation of the experimental data with the MD simulations revealed that counterion mobility, the relative distances between the three partners, and the hydrogen bond lifetimes are more decisive for the response features observed than actual distances between interacting atoms in a complex or the orientation of binding moieties. TBA has been found to yield the highest imprinting factor, also showing a unique dual behavior regarding the interaction with template and fluorescent monomer. Finally, interesting differences between both enantiomers have been observed in both theory and experiment, suggesting true control of enantioselectivity. The contribution concludes with suggestions for translating the findings into actual MIP development.
Molecularly Imprinted Polymers with Integrated Fluorescence as Versatile Biomimetic Sensing Matrices
(2018)
Molecularly imprinted polymers (MIPs) are an established, versatile and high-performance matrix for the selective separation or enrichment of (bio)chemical species, especially small molecules of biochemical or environmental relevance. MIPs are prepared through the polymerization of a mixture of functional monomers and cross-linkers in the presence of the template with subsequent extraction of the latter. Conceptionally, this process can be seen as mimicking in a strongly accelerated, though single-step manner a biological process such as antibody formation. Because the resulting MIPs contain cavities in their matrix that are complementary in size, shape and electronic/ electrostatic or hydrogen bonding demand to the imprinted target molecule or template, these polymers are frequently termed “artificial antibodies”. Compared to natural antibodies, they are chemically and physically much more robust. Regarding sensitivity and selectivity, however, there is still a gap to bridge before MIPs can fully compete with antibodies.
Another favorable aspect that distinguishes MIPs from antibodies is that they can be endowed with an explicit function, allowing the use of MIPs in applications that require more than only an efficient binder. For instance, if specifically designed and polymerizable fluorescent indicators are integrated as functional monomers into a MIP, direct fluorescence sensing can be accomplished. Because MIPs can be prepared in a variety of different formats, their combination with miniaturized or other specific analytical techniques or sensory devices is possible, especially when the transduction mode is light. This presentation will introduce basic design considerations, challenges, limitations and the potential that lies with such sensor materials with some recent examples of our group, targeting various organic oxoanions as analytes.
Sphingosine-1-phosphate (S1P) is a bioactive sphingo-lipid with a broad range of activities coupled to its role in G-protein coupled receptor signalling. Monitoring of both intra and extra cellular levels of this lipid is challenging due to its low abundance and lack of robust affinity assays or sensors. We here report on fluorescent sensory core-shell molecularly imprinted polymer (MIP) particles responsive to near physiologically relevant levels of S1P and the S1P receptor modulator fingolimod phosphate (FP) in spiked human serum samples. Imprinting was achieved using the tetrabutylammonium (TBA) salt of FP or phosphatidic acid (DPPA·Na) as templates in combination with a polymerizable nitrobenzoxadiazole (NBD)-urea monomer with the dual role of capturing the phospho-anion and signalling its presence. The monomers were grafted from ca 300 nm RAFT-modified silica core particles using ethyleneglycol dimethacrylate (EGDMA) as crosslinker resulting in 10–20 nm thick shells displaying selective fluorescence response to the targeted lipids S1P and DPPA in aqueous buffered media. Potential use of the sensory particles for monitoring S1P in serum was demonstrated on spiked serum samples, proving a linear range of 18–60 μM and a detection limit of 5.6 μM, a value in the same range as the plasma concentration of the biomarker.
Ergot alkaloids play a significant role in human history for more than 1000 years and are part of the most common contaminants of food and feed worldwide. Their high toxicity against humans and livestock even at low concentrations causes a high demand for quick and reliable analytics even though no European limits for ergot alkaloids have been determined yet. Currently the most common methods for the quantitation of the six major ergot alkaloids and their corresponding stereoisomers are HPLC based, using either fluorescence or mass spectrometric detection. Whereas these conventional detection methods measure each compound individually, a novel approach is to transfer all ergot alkaloids to one basic structure, which could be measured as a sum parameter.
Since all ergots contain a lysergic acid amide moiety and a differing peptide component, cleaving the molecule into a simple lysergic acid derivative, which could be quantified via either HPLC-FLD or MS/MS, is intended. To clean up the cleavage reaction mixture molecularly imprinted polymers (MIPs) are a simple and effective way to separate the desired structure. Due to the selectivity of MIPs, an improved matrix separation is expected, which results in fewer interferences in the FLD and the possibility to measure samples with more complex matrices. When fully developed, the novel method could overcome some major drawbacks of the conventional detection methods. Higher throughput and the need for less well-trained personnel are just two advantages, that should lead to a quick and cheap quantitation of ergot alkaloids. First results of this project will be presented, funded by the German ZIM program (Zentrales Innovationsprogramm Mittelstand) of the Federal Ministry for Economic Affairs and Energy.
Ergot alkaloids play a significant role in human history for more than 1000 years and are part of the most common contaminants of food and feed worldwide. Their high toxicity against humans and livestock even at low concentrations causes a high demand for quick and reliable analytics even though no European limits for ergot alkaloids have been determined yet. Currently the most common methods for the quantitation of the six major ergot alkaloids and their corresponding stereoisomers are HPLC based, using either fluorescence or mass spectrometric detection. Whereas these conventional detection methods measure each compound individually, a novel approach is to transfer all ergot alkaloids to one basic structure, which could be measured as a sum parameter.
Since all ergots contain a lysergic acid amide moiety and a differing peptide component, cleaving the molecule into a simple lysergic acid derivative, which could be quantified via either HPLC-FLD or MS/MS, is intended. To clean up the cleavage reaction mixture molecularly imprinted polymers (MIPs) are a simple and effective way to separate the desired structure. Due to the selectivity of MIPs, an improved matrix separation is expected, which results in fewer interferences in the FLD and the possibility to measure samples with more complex matrices. When fully developed, the novel method could overcome some major drawbacks of the conventional detection methods. Higher throughput and the need for less well-trained personnel are just two advantages, that should lead to a quick and cheap quantitation of ergot alkaloids. First results of this project will be presented, funded by the German ZIM program (Zentrales Innovationsprogramm Mittelstand) of the Federal Ministry for Economic Affairs and Energy.
Glycoproteins are abundant on the cell surface of mammals, providing structural support, modulating cell Membrane properties, and acting as signaling agents. Variation of glycosylation patterns has been found to indicate various disease states, including cell malignancy. Sialic acid (SA) is present as a terminating group on cell-surface glycans, and its overexpression has been linked to several types of cancer. Detection of SA on the cell surface is therefore critical for detection of cancer in its early stages. In this work, a fluorescent molecularly imprinted polymer layer targeting SA was synthesized on the surface of silica-coated polystyrene (PS) particles. Compared to previous works, a PS core supplies a lighter, lower-density support for improved suspension stability and scattering properties. Moreover, their smaller size provides a higher surface-area-to-volume ratio for binding. The incorporation of a fluorescent monomer in the MIP shell allowed for simple and rapid determination of binding specificity in polar media due to a deprotonation−reprotonation interaction mechanism between the fluorescent monomer and SA, which led to spectral changes.
Upon titration of the MIP particles with SA in suspension, an increase in fluorescence emission of the particles was observed, with the MIP particles binding SA more selectively compared to the nonimprinted polymer (NIP) control particles. In cell staining experiments performed by flow cytometry, the binding behavior of the MIP particles compared favorably with that of SA-binding lectins. NIPs prepared with a “dummy” template served as a better negative control in cell binding assays due to the favorable inward orientation of template-binding functional groups in the polymer shell, which reduced nonspecific binding. The results show that fluorescent MIPs targeting SA are a promising tool for in vitro fluorescence staining of cancerous cells and for future diagnosis of cancer at early stages.