HR-CS-GFMAS turned out to be a sensitive, fast and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) at a temperature of 1550°C. GaF can be detected at 211.248 nm providing limits of quantificationin the low μg/L range. However, several species specific effects where observed when analyzing PFASs.
Iron isotopes are used in a variety of fields from e.g., geologic question to medical applications. Measurements of iron isotopes are usually performed as delta measurements to an artificial based delta zero standard. In the case of Fe isotopes is that delta zero standard IRMM-014, a pure Fe metal. Unfortunately, that conventional delta zero reference material defining the 56/54Fe scale is out of stock and therefore unavailable. To overcome that situation and fulfill the need for laboratories that measure Fe isotope on a regular basis we will provide a set of solutions with IRMM-014 and a second anchor point for Fe isotope ratio measurements that is based on a pure Fe metal. This new second anchor point, a high purity Fe from BAM, will be calibrated against IRMM-014 and can be used as bracketing standard or as reference value for stable Fe isotope measurements.
We are in the good situation that BAM ordered a large stock of IRMM-014 several years ago. That stock of IRMM-014 Fe cubes and IRMM-014 Fe wires will be dissolved in 6M HCl in a large quantity. The new anchor point, the high purity Fe metal, that is commercially available at BAM, is a pure Fe metal with only trace amounts of impurities. The high purity BAM material will also be dissolved in 6M HCl in large quantity. Several aliquots of both solutions will be measured on the Neptune Plus MC-ICP-MS to define this second anchor point with a low uncertainty. Further will we send several aliquots of both solutions to different laboratories to also measure this second anchor point of high purity Fe on the 56/54Fe scale.
We will report the values of that study on BAM high purity Fe and will provide a guide for scale conversion to the IRMM-014 scale and for uncertainty calculation to use that new anchor point instead of the exhausted IRMM-014.
The variation of isotope ratios is increasingly used to unravel natural and technical questions. With new upcoming techniques and research topics in the last two decades, such as material provenance or food authenticity to animal and human migration studies, the number of published isotope data has strongly increased. Here, isotope reference materials are indispensable to enable a reliable method validation or even SI-traceability. The fast development and broad availability of inductively coupled plasma mass spectrometry instrumentation (ICP-MS) also lead to an expansion of the classical research areas and new elements are under investigation. Owing to this large expansion of the field, the production and certification of isotope reference materials for calibration and validation is lagging behind, even for classical applications such as conventional 87Sr/86Sr isotope ratio analysis. To improve this situation, BAM organized an interlaboratory comparison (ILC) comprising of thirteen international laboratories for the characterisation of 87Sr/86Sr isotope ratios in geochemical and industrial reference materials. Six reference materials (four cements and two rocks) were provided as powder requiring extensive sample preparation prior to isotopic measurement. Additional requirements included the use of the conventional method for obtaining 87Sr/86Sr isotope ratios, also known as radiogenic 87Sr/86Sr isotope ratios, and the assessment of the measurement uncertainty. The primary goal was to evaluate potential differences in the application of multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for conventional 87Sr/86Sr isotope ratio determination, with a secondary goal to provide reference values for the 87Sr/86Sr isotope ratios in these potential new reference materials. All reported results are accompanied by an uncertainty statement and are traceable to the conventional method, which will be described in detail within this presentation. Current state-of-the-art statistical models were used to ensure the proper evaluation of the reported results and their associated measurement uncertainties within the frame of this ILC. Combined with results from appropriate homogeneity assessment, reference values for 87Sr/86Sr isotope ratios will be assigned.
In the interest of exploring their potential in the field of single particle analysis, a Microdroplet Generator (MDG) was coupled to an ICP-ToF-MS. Isotopic Dilution Analysis was also incorporated for the size determination of three different Platinum nanoparticles samples (50, 63 and 70 nm). The performance of the technique was validated by comparison to traditional size characterization techniques (sp-ICP-ToF-MS, TEM), while the robustness of the technique was proven by incorporating NaCl in the samples’ matrix, up to 100 mg/L.
The Federal Institute for Materials Research and Testing (BAM) organised an interlaboratory comparison (ILC) for the characterisation of 87Sr/86Sr isotope ratios in limestone (IAG/CGL ML-3) and Penrhyn slate (IAG OU-6) reference materials by applying the conventional method for 87Sr/86Sr isotope ratios. Samples were sent to thirteen analytical laboratories . Since both samples are powdered, rock materials, dissolution of the sample and Sr isolation via ion exchange chromatography were mandatory. This was done using acid, microwave/acid, bomb/acid digestion or borate fusion and subsequent isolation of Sr by means of commercially available ion exchange resins. In this study, we present and discuss the potential effects that differences between laboratories, and between two instrumental measurement techniques (i.e., MC-ICP-MS and MC-TIMS), may have upon the dispersion of measurement results of the 87Sr/86Sr isotope ratio in the two aforementioned reference materials. We used a statistical mixed effects model to assess the potential effects of both the laboratory and the measurement technique. Consensus values for both materials and associated standard uncertainties {(IAG/CGL ML-3 (0.708245±0.000004) mol/mol; IAG OU-6 (0.729769±0.000008) mol/mol} were estimated by fitting a linear, Gaussian mixed effects model (Pinheiro and Bates 2000) using the R function “lmer” defined in package “lme4”. The statistical results showed that there is no significant effect attributable to differences between instrumental techniques when both materials are considered together, or separately. The p-value of the test of significance of the measurement technique effect is greater than 0.54. For both materials there were statistically significant effects attributable to differences between laboratories when the measurement results for both materials were considered together and separately. This effect is less than 0.00004 in absolute value. However, for neither material did consideration or disregard for such differences induce significant changes in the estimate of the consensus value for the 87Sr/86Sr isotope ratio. Therefore, the effects attributable to differences between instrumental techniques or between laboratories can safely be disregarded when computing the best estimate for the true value of 87Sr/86Sr isotope ratio in these materials, by the community of expert laboratories represented in this study.
Deciphering microbiological influenced corrosion processes on steel with single cell-ICP-ToF-MS
(2022)
Microbiologically influenced corrosion (MIC) is a highly unpredictable process dictated by the environment, microorganisms, and the respective electron source. Interaction pathways between cells and the metal surface remain unclear. The development of this novel single cell-inductively coupled plasma-time of flight-mass spectrometry analytical method and a MIC-specific staining procedure facilitate the investigation of steel-MIC interactions. With this it is possible to analyze the multi-elemental fingerprint of individual cells. The detection method revealed elemental selectivity for the corrosive methanogenic archaeal strain Methanobacterium-affiliated IM1. The interface between material and environmental analysis thus receives special attention, e.g., when considering MIC on solid steel. Hence, the possible uptake of individual elements from different steel samples is investigated. Results showed the cells responded at a single-cell level to the different types of supplemented elements and displayed the abilities to interact with chromium, vanadium, titanium, cobalt, and molybdenum from solid metal surfaces. The information obtained will be used in the future to elucidate underlying mechanisms and develop possible material protection concepts, thus combining modern methods of analytical sciences with materials research.
References.
Per- and polyfluorinated alkyl substances (PFASs) are a group of several thousand individual compounds. Many PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their various chemical and physical properties as well as the high number of compounds. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate realistic PFAS pollution levels.
PFAS sum parameters display the proportion of organically bound fluorine that can either be extracted (EOF) or adsorbed to activated carbon (AOF). For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) is a sensitive and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L.
In the present work a HR-CS-GFMAS method for EOF analysis was utilized for suspended particulate matter (SPM) analysis in German rivers in time lines from 2005–2020. Therefore, time and spatial resolved trends were investigated. In addition, SPM samples were analyzed for the Σ41PFAS using target analysis based on UHPLC-HRMS. Overall, target analysis drastically underestimated the total PFAS burden in SPM of German rivers compared to the EOF HR-CS-GFMAS analysis. Using a fluorine mass balance approach, only 0.2% to 38.6% of the EOF was explainable using the Σ41PFAS determined with target analysis. Our study highlights the need to integrate PFAS sum parameters (e.g., EOF with HR-CS-GFMAS) in PFAS risk assessment strategies.
Contamination of the environment with antibiotics is of great concern as it promotes the evolution of antimicrobial resistances. In case of amoxicillin (AMX) in the aquatic environment, further risk arises from hydrolysis products (HPs) which can cause allergy. To assess these risks, a comprehensive investigation and understanding of the degradation of AMX is necessary. We investigated the hydrolysis rate of AMX in different types of water as well as the influence of temperature and irradiation. The content of the heavy metal ions copper and zinc was found to be crucial for the hydrolysis rate of AMX and stability of HPs. Eventually, a new degradation pathway for AMX could be elaborated and confirmed by tandem mass spectrometry (LC-MS/MS).
Thirteen laboratories participated in an international interlaboratory comparison for the determination of 87Sr/86Sr isotope ratios in four cement reference materials (RM) using the conventional method for 87Sr/86Sr isotope ratios analyses. Sample dissolution and Sr isolation via ion exchange chromatography were required since the cement samples were distributed as powders. Analytical preparation included the use of various digestion methods including mixed mineral acids, microwave/acid, bomb/acid digestion or borate fusion, followed by Sr separation using ion exchange chromatography. In this study, we evaluated whether any statistically significant differences were attributable to instrumental differences (i.e., MC-ICP-MS and MC-TIMS), or to laboratory-specific techniques (different sample preparation techniques, Sr isolation and the procedures for correcting the data outputs). To evaluate these effects, consensus values for cement RMs and associated standard uncertainties were estimated by fitting a linear, Gaussian mixed effects model using the R function “lmer” defined in package “lme4”. No statistically significant effects (SSE) attributable to instrumental differences regardless of whether the materials are considered together or separately were evident. There were SSE attributable to differences between laboratories for three cement RMs when the individual cements were considered separately. Since consideration or disregard for such differences does not induce significant changes in the estimate of the consensus values for the 87Sr/86Sr isotope ratios in cement RMs, these effects can safely be neglected when calculating the best estimates for the true values of 87Sr/86Sr isotope ratios in these RMs.
Per- and polyfluorinated alkyl substances (PFASs) are a substance class of over 4730 individual compounds. Several PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their different chemical and physical properties as well as the high number of target substances. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate a realistic PFAS pollution level.
PFAS sum parameters compromise the proportion of organically bound fluorine that can either be extracted (EOF) or adsorbed to activated carbon (AOF). For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) is a sensitive and highly selective tool for indirect fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L.
Here, we describe a fast and simple extraction method for the determination of the EOF using HR-CS-GFMAS in soil samples. Common approaches for the EOF determination use solid phase extraction (SPE). To omit the bias of this time consuming and expensive step we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol. Comparison of the method with and without an SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. In the next step, the applicability of our method was tested for other solid matrices. In view of steadily increasing numbers of PFASs, our method will make an important contribution in assessing the pollution situation as well as support policy makers in deriving exposure limits for PFASs in the future.