Iron isotopes are used in a variety of fields from e.g., geologic question to medical applications. Measurements of iron isotopes are usually performed as delta measurements to an artificial based delta zero standard. In the case of Fe isotopes is that delta zero standard IRMM-014, a pure Fe metal. Unfortunately, that conventional delta zero reference material defining the 56/54Fe scale is out of stock and therefore unavailable. To overcome that situation and fulfill the need for laboratories that measure Fe isotope on a regular basis we will provide a set of solutions with IRMM-014 and a second anchor point for Fe isotope ratio measurements that is based on a pure Fe metal. This new second anchor point, a high purity Fe from BAM, will be calibrated against IRMM-014 and can be used as bracketing standard or as reference value for stable Fe isotope measurements.
We are in the good situation that BAM ordered a large stock of IRMM-014 several years ago. That stock of IRMM-014 Fe cubes and IRMM-014 Fe wires will be dissolved in 6M HCl in a large quantity. The new anchor point, the high purity Fe metal, that is commercially available at BAM, is a pure Fe metal with only trace amounts of impurities. The high purity BAM material will also be dissolved in 6M HCl in large quantity. Several aliquots of both solutions will be measured on the Neptune Plus MC-ICP-MS to define this second anchor point with a low uncertainty. Further will we send several aliquots of both solutions to different laboratories to also measure this second anchor point of high purity Fe on the 56/54Fe scale.
We will report the values of that study on BAM high purity Fe and will provide a guide for scale conversion to the IRMM-014 scale and for uncertainty calculation to use that new anchor point instead of the exhausted IRMM-014.
Introduction
Per- and polyfluorinated alkyl substances (PFASs) are a group of over 4730 individual compounds. Several PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their various chemical and physical properties as well as the high number of compounds. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate realistic PFAS pollution levels.
Methods
For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. In our study we used high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) which is a sensitive and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L.
Results
Here, we present an improved method for the determination of PFASs using HR-CS-GFMAS via GaF detection. The optimized method includes a modifier pretreatment step using a mixture of Mg, Pd and Zr and a correction measurement using perfluorooctanoic acid. The combination of both resulted in increased accuracy and precision as well as overall lower detection limits. Furthermore, during optimization the influence of species-specific responses during HR-CS-GFMAS analysis was reduced resulting in a more accurate determination of PFAS sum parameters. To test the applicability of the improved method, we analysed soil samples from a former fire-fighting training area combining the improved method for detection with our previously optimized extraction method for extractable organically bound fluorine (EOF) determination in soils.
Innovative aspects
• Highly sensitive and selective method for fluorine/PFASs analysis based on HR-CS-GFMAS
• Increased accuracy for the determination of EOF
• Reduction of PFAS species-specific responses by optimized modifier conditions
HR-CS-GFMAS turned out to be a sensitive, fast and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) at a temperature of 1550°C. GaF can be detected at 211.248 nm providing limits of quantificationin the low μg/L range. However, several species specific effects where observed when analyzing PFASs.
With the continuous release of anthropogenic pollutants into the environment, substantial risks for the human health arise. Concerning are especially persistent substances (e.g., PFAS) as they accumulate in food chains which inevitably result in the transgression of negative impact threshold levels. Environmental Analytical Chemsitry interfaces all disciplines of Risk Assessment. Therefore it is the important tool to identify, monitor, and remediate environmental pollutants. Based on the example of PFAS, a workflow to tackle environmental pollutants in a retro- and pro-spective way is shown. Within the project, the worldwide situation of environmental pollutants will be illustrated for the example of PFAS. As the major discipline to confront the problem, analytical chemistry will be shown as a key tool for contesting PFAS and creating safe-by-design materials in the future.
Per- and polyfluoroalkyl substances (PFAS) are a large group of organofluorine surfactants used in the formulations of thousands of consumer goods. The continuous use of PFAS in household products and the discharge of PFAS from industrial plants into the sewer system have been resulted in contaminated effluents and sewage sludge from wastewater treatment plants (WWTPs) which became an important pathway for PFAS into the environment. Because sewage sludge is often used as fertilizer its application on agricultural soils has been observed as significant input path for PFAS into our food chain. To produce high-quality phosphorus fertilizers for a circular economy from sewage sludge, PFAS and other pollutants (e.g. pesticides and pharmaceuticals) must be separated from sewage sludge. Normally, PFAS are analyzed using PFAS protocols typically with time-consuming extraction steps and LC-MS/MS target quantification. However, for screening of PFAS contaminations in wastewater-based fertilizers also the DGT technique can be used for the PFAS extraction. Afterwards, combustion ion chromatography (CIC) can be applied to analyze the “total” amount of PFAS on the DGT binding layer. The DGT method was less sensitive and only comparable to the extractable organic fluorine (EOF) method values of the fertilizers in samples with >150 µg/kg, because of different diffusion properties for various PFAS, but also kinetic exchange limitations. However, the DGT approach has the advantage that almost no sample preparation is necessary. Moreover, the PFAS adsorption on the DGT binding layer was investigated via surface sensitive spectroscopical methods, such as Fourier-transform infrared (FT-IR) and fluorine K-edge X-ray absorption near-edge structure (XANES) spectroscopy.
Accurate and precise isotope ratio measurements of heavy elements are playing an increasinglyimportant role in modern analytical sciences and have numerous applications. Today, isotope ratio measurements are typically performed with two principal techniques: thermal ionization mass spectrometry (TIMS) and multiple collector-inductively coupled plasma mass spectrometry (MC-ICP-MS). To obtain accurate results by mass spectrometry, isotopic certified reference materials (iCRMs) are needed for mass bias correction and for the validation of the method used for analysis.Thus, it is of paramount importance to achieve measurement comparability of all data reported, and to assess measurement capability of each CRM producer/National Metrology Institute (NMI). Therefore, the international comparison (CCQM-P213) was performed to assess the analytical capabilities of NMIs for the accurate determination of copper isotope ratio delta values in high purity materials. The study was proposed by the coordinating laboratories, National Research Council Canada (NRC), National Institute of Standards and Technology (NIST), Bundesanstalt für Materialforschung und -prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB), as an activity of the Isotope Ratio Working Group (IRWG) of the Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). Participants included six NMIs and one designated institute (DI) from the six countries. Although no measurement method was prescribed by the coordinating laboratories, MC-ICP-MS with either standard-sample bracketing (SSB) or combined SSB with internal normalization (C-SSBIN) models for mass bias correction were recommended. Results obtained from the six NMIs and one DI were in good agreement.
This dataset represents the electronic supplementary material (ESM) of the publication entitled "Characterisation of conventional 87Sr/86Sr isotope ratios in cement, limestone and slate reference materials based on an interlaboratory comparison study", which is published in Geostandards and Geoanalytical Research under the DOI: 10.1111/GGR.12517. It consists of four files. 'ESM_Data.xlsx' contains all reported data of the participants, a description of the applied analytical procedures, basic calculations, the consensus values, and part of the uncertainty assessment. 'ESM_Figure-S1' displays a schematic on how measurements, sequences and replicates are treated for the uncertainty calculation carried out by PTB. 'ESM_Technical-protocol.pdf' is the technical protocol of the interlaboratory comparison, which has been provided to all participants together with the samples and which contains bedside others the definition of the measurand and guidelines for data assessment and calculations. 'ESM_Reporting-template.xlsx' is the Excel template which has been submitted to all participants for reporting their results within the interlaboratory comparison. Excel files with names of the the structure 'GeoReM_Material_Sr8786_Date.xlsx' represent the Rcon(87Sr/86Sr) data for a specific reference material downloaded from GeoReM at the specified date, e.g. 'GeoReM_IAPSO_Sr8786_20221115.xlsx' contains all Rcon(87Sr/86Sr) data for the IAPSO seawater standard listed in GeoReM until 15 November 2022.
Detector deadtime
(2023)
Determination of absolute (SI‐traceable) isotope ratios: The use of Gravimetric Isotope Mixtures
(2023)
The presentation is brief overview on how to use gravimetric isotope mixtures to determine SI traceable isotope ratios. There is no mass spectrometer on earth that directly measures isotope ratios. Mass spectrometers will always measure signal intensity ratios instead. The actual problem is that the measured intensity ratios differ more or less from the isotope ratios. The difference can be up to more than 10 % in case of lithium while it‘s below 1 % in case of the heavier elements like lead or uranium. Consequently, the signal intensity ratios are expressed for example in V/V depending on the type of mass spectrometer you are using, while the isotope ratios are expressed in mol/mol. This phenomenon is called Instrumental Isotopic Fractionation (or short IIF) but the more common name is still mass bias (even though this name is not entirely correct). To convert the measured into the isotope ratio usually a simple multiplication with a so-called correction (or short K) factor is done. Therefore, the problem is to determine the K factor. In absence of isotope reference materials the golden route is via gravimetric isotope mixtures, which will be explained within the presentation.
The need for quality assessment of anthropogenic impact on environmental pollution is increasing due to discharge from various industries, the use of chemicals in agriculture and the consumption of fossil fuels. Diminishing resources such as natural waters used for the cultivation of agricultural products, plant and animal habitats are under severe pollution pressure and are at constant risk. Several parameters, such as Pb, Cd, Ni, Hg were listed by Water Framework Directive in Directive(2008/105/EC) in the priority substances. Cadmium and Hg were identified as priority hazardous substances whereas As is an important contaminant for its potential toxicological and carcinogenic effects. An inter-comparison study is organised in EURAMET TC-MC in order to demonstrate the capability participants for measuring five elements in river water. The participants carried out measurements for analytes: Pb, Cd, Ni and As as mandatory elements, and Se as an optional one. Participants were asked to perform the measurements with respect to the protocol provided. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).