Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2019 (17) (entfernen)
Dokumenttyp
- Vortrag (12)
- Zeitschriftenartikel (3)
- Beitrag zu einem Tagungsband (2)
Schlagworte
- Industrielle Radiographie (3)
- X-ray back scattering (3)
- Additive Fertigung (2)
- Additive manufacturing (2)
- Bildqualitätsnachweis (2)
- International Institute of Welding (2)
- Radiographische Prüfung (2)
- Additive Manufacturing (1)
- Art restauration (1)
- Bildqualität (1)
- Cold to fast neutron testing (1)
- Computertomographie (1)
- DGZfP-Richtlinien (1)
- Data Processing (1)
- Digitale Radiographie (1)
- Digitaler Filmersatz (1)
- Direktumwandelnde Detektoren (1)
- Dual Energy Imaging (1)
- Energieauflösende Detektoren (1)
- Fiber reinforced polymer (1)
- Filmersatz (1)
- General Assembly (1)
- Klassifizierung (1)
- Laminography (1)
- Metal Magnetic Memory (1)
- Mikropartikel (1)
- Neutron Imaging (1)
- Non-destructive testing (1)
- Nondestructive Testing (1)
- Nondestructive tesing (1)
- Normung (1)
- Personnel Education (1)
- Photon Counting Detectors (1)
- Photon counting detector (1)
- Radiographic Testing (1)
- Radiographic testing (1)
- Radiography based weld inspection (1)
- Repair patch (1)
- Requirements of Standards (1)
- Revision of ISO 24497 (1)
- Röntgenrückstreuung (1)
- Stand der Normung (1)
- Standardisierung bei DIN, CEN und ISO (1)
- Standards (1)
- Status in Germany (1)
- Sub-Commission V-A (1)
- Tomography of wood samples (1)
- Wind energy (1)
- X-ray (1)
- Zerstörungsfreie Prüfung (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17) (entfernen)
Eingeladener Vortrag
- nein (12)
X-ray back scatter imaging is rarely applied compared to classical X-ray projection imaging. More than 20 years ago the company Philips developed “COMSCAN”, a first application case for aircraft industry, which allowed even a depth resolution using back scatter imaging. The company AS&E in Boston offers back scatter imaging solutions for the security market. The principle is to scan the object with a highly collimated X-ray needle beam from one side only and to detect the backscattered radiation by a large area detector side by side with the collimation wheel. A new prototype is investigated at BAM for application and optimization in non-destructive testing. As modern industrial application field in-situ inspection in additive manufacturing is targeted. The accessibility of the printed part during the production process is very limited. This prevent the application of a two sided X-ray inspection or Computed Tomography, were an rotation of the object is required to acquire projections from 360 degrees. An important advantage for the X-ray back scatter technique are also the materials used in additive manufacturing (polymers, ceramics, light metals like Aluminum or Titanium). These materials with lower density and lower Z values give better scatter signals than metals with higher densities and Z values. The back scatter intensity decreases with increasing density and Z value of the material. But the requirements on spatial resolution and contrast sensitivity are more stringent for non-destructive testing of additive manufactured parts compared to the security area. In NDT sizes of indications smaller than 1 mm have to be detected clearly. The investigation of these limits on a state-of-the-art prototype for X-ray back scattering using rotating collimated X-ray needle beams is a part of the BAM project “ProMoAM”. The contribution shows first results of the optimization for NDT and the achieved application limits for several example cases.
X-ray back scatter imaging is rarely applied compared to classical X-ray projection imaging. 20 years ago the company Philips developed “COMSCAN”, a first application case in the aircraft industry, which allowed even a depth resolution using back scatter imaging. The company AS&E in Boston offers back scatter imaging solutions for the security market. Their principle is to scan the object with a highly collimated X-ray needle beam from one side only and detect the backscattered radiation by a large area detector side by side with the collimation wheel. A new prototype is investigated at BAM for application and optimization in non-destructive testing. As modern industrial application field in-situ testing in additive manufacturing is targeted. The accessibility of the printed part during the production process is very limited. This prevent the application of a two sided X-ray inspection or Computed Tomography, were an rotation of the object is required to acquire projections from 360 degrees. An important advantage for the X-ray back scatter technique are also the materials used in additive manufacturing (polymers, ceramics, light metals like Aluminum or Titanium). These materials with lower density and lower Z values give better scatter signals than metals with higher densities and Z values. The back scatter intensity decreases with increasing density and Z value of the material. But the requirements on spatial resolution and contrast sensitivity are more stringent for non-destructive testing of additive manufactured parts compared to the security area. In NDT sizes of indications smaller than 1 mm have to be detected clearly. The investigation of these limits on a stateof-the-art prototype for X-ray back scattering using rotating collimated X-ray needle beams is a part of the BAM project “ProMoAM”. The contribution shows first results of the optimization for NDT and the achieved application limits for several example cases.
X-ray back scatter imaging is rarely applied compared to classical X-ray projection imaging. 20 years ago the company Philips developed “COMSCAN”, a first application case in the aircraft industry, which allowed even a depth resolution using back scatter imaging. The company AS&E in Boston offers back scatter imaging solutions for the security market. Their principle is to scan the object with a highly collimated X-ray needle beam from one side only and detect the backscattered radiation by a large area detector side by side with the collimation wheel. A new prototype is investigated at BAM for application and optimization in non-destructive testing. As modern industrial application field in-situ testing in additive manufacturing is targeted. The accessibility of the printed part during the production process is very limited. This prevent the application of a two sided X-ray inspection or Computed Tomography, were an rotation of the object is required to acquire projections from 360 degrees. An important advantage for the X-ray back scatter technique are also the materials used in additive manufacturing (polymers, ceramics, light metals like Aluminum or Titanium). These materials with lower density and lower Z values give better scatter signals than metals with higher densities and Z values. The back scatter intensity decreases with increasing density and Z value of the material. But the requirements on spatial resolution and contrast sensitivity are more stringent for non-destructive testing of additive manufactured parts compared to the security area. In NDT sizes of indications smaller than 1 mm have to be detected clearly. The investigation of these limits on a stateof-the-art prototype for X-ray back scattering using rotating collimated X-ray needle beams is a part of the BAM project “ProMoAM”. The contribution shows first results of the optimization for NDT and the achieved application limits for several example cases.
Modern wind turbine rotor blades consist of sandwich shell segments made from glass fiber reinforced polymers. During manufacturing, defects can arise which could lead to failure of the whole component under dynamic mechanical and thermal loads. Hence during operation defects can arise which, if detected, can be repaired locally and in-situ by applying repair patches instead of taking the whole rotor blade down and repair it remotely. This method is much more time and cost effective, since the shut-down time of the energy converter is limited to a minimum. These repair patches can, however, also lead to new defects if not applied optimally. Therefore, it is necessary to control the quality of the repair patches to ensure the best possible restoration of structural integrity of the component. As a rotor blade is an object with a large aspect ratio, X-ray laminography is predestined to provide 3D information of the objective volume. To enhance the amount of information gained from laminographic reconstruction, we use in this study a photon counting and energy discriminating X-ray detector and apply a material decomposition algorithm to the data. By inherently separating the incident spectra within the detection process into two distinct energy bins, the basis material decomposition can provide material resolved images. Choosing glass and epoxy resin as basis materials and numerically solving the inverse dual-energy equation system, the reconstructed laminographic datasets contain highly valuable information about the distribution of the basis materials within the structure. Furthermore, cross- artifacts arising from the limited angle of the projection data can be reduced by this method which allows to investigate structures that were hidden underneath the artefacts.
Metallische Mikropartikel in der Größenfraktion von ca. 10 – 100 Mikrometer bilden das Grundmaterial für den additiven Aufbau komplexer Strukturen durch lokales Aufschmelzen mit einem Laserstrahl. Entscheidend für dieses Verfahren ist die Kenntnis der Größen-, Form- und Defektverteilungen von Partikelfraktionen, da sie direkten Einfluss auf die Fließfähigkeit des Pulvers während des lagenweisen Auftragens, als auch auf die finale innere Porosität des Bauteils haben. Im Pulver vorhandene Poren verlassen in der Regel das Schmelzbad vor dem Erstarren nicht wieder, da deren Konvektionszeiten größer sind als die Zeit, während der das lokale Schmelzbad besteht, so dass einmal durch die Ausgangspartikel eingebrachte Poren in der Regel auch im fertigen Bauteil verbleiben. Eine strenge Qualitätskontrolle des Ausgangspulvers ist also Voraussetzung, um hochwertige Bauteile mit geringer Restporosität zu erhalten. Der Vorteil der Röntgentomographie ist dabei, dass mit nur sehr geringem Präparationsaufwand innenliegende Poren bis zu einem Durchmesser von wenigen Mikrometern detektiert werden können. Dies ist mit konkurrierenden Verfahren (Licht- / Elektronenmikroskopie, Laserbeugung) so nicht möglich. Zusammenfassend werden wir zeigen, dass die zerstörungsfreie Bildgebung mit der Röntgen-Mikrotomographie für die Qualitätskontrolle in der additiven Fertigung ein leistungsfähiges Werkzeug ist. Wir erörtern die Grenzen der Methode durch eine numerische Studie mithilfe des Simulationsprogramms aRTist. Dabei werden verschiedene Partikelgrößen dahingehend untersucht, welche Poren mit mikroradiographischen Verfahren detektierbar sind. Dazu wird ein Modell für eine dreilagige dichteste Kugelpackung entwickelt, so dass auch Überlagerungen von Anzeigen untersucht werden können. Im Ergebnis werden verschiedene Partikel- und Porengrößenkombinationen untersucht und die entsprechenden Detektionsgrenzen bestimmt.
Neben der klassischen Durchstrahlung wird die bildgebende Röntgen-rückstreuung bisher nur sehr begrenzt eingesetzt. Vor über 20 Jahren hatte Philips mit „COMSCAN“ eine erste industrielle Anwendung in der Luftfahrt gefunden, die sogar eine Tiefenauflösung besaß. Die Firma AS&E in Boston bietet Röntgenrückstreu-Anlagen für den Sicherheitsbereich an. In diesen wird mit einem hochkollimierten Nadelstrahl aus einem rotierenden Blendenrad ein Objekt einseitig abgetastet. Zur Detektion der gestreuten Strahlung aus dem Objekt werden großflächige Detektoren direkt neben dem rotierenden Nadelstrahlkollimator eingesetzt. Ein solcher Prototyp wird an der BAM für den Einsatz in der zerstörungsfreien Prüfung untersucht und optimiert. Als neues industrielles Einsatzgebiet wird dabei die in situ Überwachung in der additiven Fertigung avisiert. Hier ist die Zugänglichkeit zum entstehenden Werkstück in den 3D-Druckanlagen stark eingeschränkt, was den Einsatz einer zweiseitigen Durchstrahlung oder der Computer-Tomographie, bei der das Objekt rotiert wird, verhindert. Auch sind die in der additiven Fertigung eingesetzten Werkstoffe (Polymere, Keramik, Leichtmetalle wie Al oder Ti) für die Rückstreuung besser geeignet als Metalle höherer Dichte, da das Streusignal mit der Ordnungszahl und der Materialdichte abnimmt. Allerdings sind die Anforderungen an räumliche Auflösung und Kontrastempfindlichkeit in der zerstörungsfreien Prüfung additiv gefertigter Bauteil deutlich höher als im Sicherheitsbereich, da hier Bauteilfehler mit typischen Dimensionen kleiner als 1 mm sicher detektiert werden müssen. Die Untersuchung dieser Grenzen des derzeitigen Standes der Röntgenrückstreutechnik mit Nadelstrahl ist ein Teilbereich des mehrjährigen BAM-Themenfeldprojektes „ProMoAM“. Im Vortrag werden die ersten Ergebnisse der Optimierung sowie die gefundenen Anwendungsgrenzen an Beispielen erläutert.
The revision of ISO 24497:2007 started in 2017 (by decision of Com-V at the IIW annual assembly in Shanghai). After 3 years of discussions and incorporation of many comments from all over the world the working group C-V-E-b headed by Uwe Zscherpel finalized the work with a final draft to be forwarded for final vote at ISO TC 44. The working group C-V-E-b finalised the work and can be resolved. The chair thanks for all the successfully work done, the vote to forward the latest draft to ISO for final vote was done without any negative.
Neues aus der BAM 2019
(2019)
Die Technologie der hybriden Teilchen (oder Photonen) zählenden Bilddetektoren wurde seit mehr als 2 Jahrzehnten durch Institutionen wie das CERN (MediPix-/ TimePix-Chips) oder das Paul-Scherrer-Institut (Pilatus-/ Eiger-Chips) entwickelt. Die Ursprünge dieser Technologie kommen aus der Hochenergie-Physik mit ihren Beschleuniger-basierten Experimenten, bei denen ein zuverlässiger und rauschfreier Nachweis jedes ionisierten Teilchens gefordert wird. Eine Energieauflösung wird ebenfalls oft verlangr. Das ist auch in der klassischen Radiographie von Nutzen, so wurden diese Detektoren auch dafür optimiert. Neueste Photonen zählenden Detektoren besitzen folgende exzellenten Bildeigenschaften: rauschfreie Photonen-Detektion in einem hohen Dynamikbereich (SNR >2500 erreichbar), hohe räumliche Auflösung (bis zu 10 µm Pixelgröße), Energieschwellen bis zur vollen spektralen Auflösung und eine sehr hohe Geschwindigkeit (bis zu Tausenden Bildern pro Sekunde). Diese hybriden Detektoren können mit hochabsorbierenden Sensorschichten aus CdTe, CZT oder GaAs bestückt werden, um bildgebende Anwendungen mit Gamma- oder harten Röntgenstrahlen zu realisieren, in denen bisher Szintillator basierende Bilddetektoren dominierten (z.B. für NDT, SPECT, PET). Im Beitrag wird der erste wirklich große Photonen zählende Detektor mit CdTe und einer lückenlosen Detektionsfläche, die aus einer theoretisch unbegrenzten Anzahl von MediPix-/ TimePix-Modulen besteht, gezeigt. Die erste kommerzielle Version eines solchen Detektors hat eine Fläche von 7cm x7cm, 1,6 Megapixel und erfüllt die Anforderungen der Prüfklasse „B“ in der industriellen Radiographie. Die Energie auflösenden Fähigkeiten dieses Detektors erlauben eine „Farb-Radiographie“, in der verschiedene Materialien in verschiedene Farben dargestellt werden. Der 2. Teil dieses Beitrags stellt einen voll spektral auflösenden Gamma- und Röntgen-Bilddetektor mit dickem CdTe und 2,4 Megapixel vor, der auf TimePix3-Chips basiert und eine sehr hohe Ortsauflösung von ~10 µm erreicht. Die hohe Zeitauflösung von TimePix3 wird mit großem Nutzen für eine substantielle Verbesserung der erhaltenen Bilder und Spektren zur Unterdrückung interner Fluoreszenzstrahlung sowie Comptonstreuungsanteilen, die die Bildinformation verschmieren, verwendet.