Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2019 (10) (entfernen)
Dokumenttyp
- Sonstiges (10) (entfernen)
Referierte Publikation
- nein (10)
Schlagworte
- Bauwesen (2)
- ABID (1)
- Ameisensäure (1)
- Berührungsloser Ultraschall (1)
- Clones (1)
- Compact spectrometers (1)
- Competitive Immunoassay (1)
- Corrosion (1)
- Delamination (1)
- Dickenbestimmung (1)
- Electrochemistry (1)
- False Positives (1)
- Festphasenextraktion (1)
- Fingerprint (1)
- Fluidische Anregung (1)
- Frequenzmodulation (1)
- Hapten Immunoassay (1)
- Hybridoma (1)
- Impedance spectroscopy (1)
- Kontaktloses Impakt-Echo (1)
- Korrelationsmatrix (1)
- Massenspektrometrie (1)
- Microplastics (1)
- Monoclonal Antibodies (1)
- Near-infrared (1)
- Peptide (1)
- Peptide mass fingerprinting (1)
- Plastic (1)
- Polymers of Intrinsic Microporosity (1)
- Protein G (1)
- Saure Hydrolyse (1)
- Small-angle scattering (1)
- Surface (1)
- Testing (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (3)
- 7 Bauwerkssicherheit (3)
- 7.6 Korrosion und Korrosionsschutz (3)
- 1.5 Proteinanalytik (2)
- 6 Materialchemie (2)
- 8 Zerstörungsfreie Prüfung (2)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 1.4 Prozessanalytik (1)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
Die steigende Nachfrage von zerstörungsfreien Prüfverfahren, welche die Zeitinvestition verbessern und eine kontinuierliche Messung ermöglichen, erfordert die Entwicklung des luftgekoppltes Impakt-Echo-Messverfahrens. Diese Entwicklung kann durch die fluidische Anregung ermöglicht werden.
Das Ziel dieser vorliegenden Arbeit war der Aufbau einer Messapparatur, die auf Schnelligkeit setzt und kontinuierlich misst. Nach der Durchführung der fluidischen Anregung wurden mit Hilfe eines Laservibrometers die Daten aufgenommen. Zur Analysierung der auf diese Weise erhobenen Messwerte wurden sie mittels der Fast-Fourier-Transformation in den Frequenzbereich transformiert.
Für den Zweck der Validierung wurden Zylinder-Probekörper und Platten-Probekörper wurden verwendet. Die Messungen an den Zylinder-Probekörpern lieferten erfolgreiche Ergebnisse, während die Messungen an den Platten-Probekörpern weitere Untersuchung und Entwicklung benötigten werden.
This textbook fulfills its dedication of being the “essential reference for the field, featuring protocols, analysis,fundamentals and the latest advances” of impedance spectroscopy to its readers. It really provides an insight in all facets of this powerful technique.
It should not be missed in the bookshelf of electrochemists and all other interested researchers and engineers who want to be on the current state of this technique.
The second edition of this textbook on physical electrochemistry, written by two experienced teachers of physical chemistry, corrosion engineering and materials science and engineering, covers the current knowledge which should be transferred to students of these fields.
In 20 chapters the fundamentals of electrochemistry, the most important electrochemical measurement techniques and applications of electrochemistry are covered.
It can be concluded that this study fulfills its intension of “serving as a key textbook in undergraduate courses” dealing with electrochemistry and being “a reference source for graduated students, researchers and engineers” interested in this field. Teachers will find sufficient content for preparing lectures on this topic. Even self‐learning is well supported by the clear structure, presented content and provided sources for further reading.
Die vorliegende Arbeit beschäftigt sich mit der Entwicklung eines Versuchsstandes zur Di-ckenbestimmung von Werkstoffen mithilfe von frequenzmoduliertem luftgekoppelten Ultra-schall. Zur Erzeugung des frequenzmoduliertem Signals wird ein fluidischer Oszillator ver-wendet. Die Schwingungsfrequenz des Oszillators ist von der Größe, der Geometrie und den Druckverhältnissen im Oszillator abhängig, welche durch ein Druckventil veränderbar sind. Zur Datenfassung dienen zwei Laservibrometer. Weiterhin soll die schlussendliche Dicken-bestimmung mithilfe eines Kreuzkorrelationsverfahrens erreicht werden. Während der Ent-wicklung wurden Messungen im Medium Luft, als auch mit Polyamid-Probekörpern durchge-führt. Für die Luftmessungen wurde das Ultraschallsignal an zwei Messpunkten erfasst und der Abstand zwischen diesen Messpunkten daraufhin versucht zu ermitteln. Diese Abstand-messungen wurden mit unterschiedlichen Abständen von 6 bis 15 Zentimeter durchgeführt, wobei der Abstand anhand der Daten mit einer Abweichung von unter einem Zentimeter er-folgreich bestimmt werden konnte. Die Messungen am Probekörper waren weniger Erfolg-reich, da keine reproduzierbare Dickenbestimmung erreicht werden konnte. Trotzdem kann die Entwicklung aufgrund der erfolgreichen Abstandmessung in der Luft sowie den neuen Erkenntnissen aus den Messungen am Probekörper als Erfolg betrachtet werden.
In the last years, the Process Analytical Technology (PAT) research field has become of great importance due to its connection with the industrial world. This industry related research, along with the evolutionary progress that technology has seen lately, has allowed that key analytical techniques in an industrial environment have undergone a radical development. One of these techniques has been the near-infrared spectroscopy (NIRS). This technique, currently common in "online" industrial analysis, has seen a remarkable revolution, especially since the introduction of the microelectromechanical systems technology (MEMS) in the spectroscopy field. Nowadays it is possible to find compact spectrometers no bigger than a wristwatch in the market. Although there is an unavoidable question: can these compact spectrometers actually compete against the traditional spectrometers?
In this project different calibration parameters of two compact NIR spectrometers ("Spectral Engines Oy NIR-One Sensor NM2.0", with 1550 to 1950 nm range; and "NeoSpectra Si-ware", with 1300 to 2550 nm range) were evaluated, and the obtained results were compared with a reference spectrometer ("Bruker Optik GmbH Matrix-F", with 15000 to 4000 cm–1 range). In order to obtain the different calibration parameters, a sequence of quality performance tests were conducted. The results obtained after the different experiments carried out with both compact spectrometers prove that their performance is more than acceptable for routine analysis.
Afterward, model samples of different microplastics in soil at different known concentration were analyzed with all three spectrometers. Chemometric models capable to identify and classify microplastics in soil were established. For this analysis five of the most used plastics worldwide were used: polyethylene (PE), polyethylene terephthalate (PET), polypropylene (PP), polystyrene (PS), and polyvinyl chloride (PVC). After the Principal component analysis (PCA), it can be seen that only the NIR-One NM2.0 is capable to differentiate all types of microplastics in soil at concentrations of 1–2 %, while the NeoSpectra Si-ware is unable to identify the PET sample.
The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence a risky venture. We think that it is crucial to improve the screening process to eliminate most of the immanent deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and simultaneous performance of competition experiments. The latter can directly be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones and blank supernatant has been designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the IgG concentration, which is unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration is not possible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media had been used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system, we conclude that this approach should be preferable to most other protocols leading to many of false positives, causing expensive and lengthy confirmation steps to weed out the poor clones.
Ultra-SAXS can enhance the capabilities of existing SAXS/WAXS beamlines and laboratory instruments. A compact Ultra-SAXS module has been developed, which extends the measurable q-range with 0:0015 < q 1/nm) < 0:2, allowing structural dimensions between 30 < D(nm) < 4000 to be probed in addition to the range covered by a high-end SAXS/WAXS instrument. By shifting the module components in and out on their respective motor stages, SAXS/WAXS measurements can be easily and rapidly interleaved with USAXS measurements.
Im Vergleich zu anderen Proteinen ist die Identifizierung von Antikörpern anhand ihrer Sequenz zum Beispiel mittels "peptide mass fingerprinting" schwierig. Da die Sequenzinformation eines Antikörpers aufgrund der hypersomatischen Mutation während der Affinitätsreifung nicht im Genom eines Organismus gespeichert ist, kann die Aminosäuresequenz nicht auf einfachem Weg der DNA-Sequenzierung gewonnen werden. Das ist nur in seltenen Fällen möglich, wenn dem Endanwender der Zellklon der Antikörper-produzierenden Zelle zugänglich ist. Eine Sequenzierung auf Protein-Ebene ist sehr aufwändig und teuer und wird daher fast nie für die Charakterisierung von analytischen Antikörpern verwendet. Der Mangel an Validierung dieser analytischen Antikörper, die bei Experimenten verwendeten werden, löst aber eine Reihe Probleme aus, die die Wiederholbarkeit dieser Experimente schwierig und in einigen Fällen unmöglich macht. Das sorgt jährlich für verschwendete Forschungsgelder in Milliardenhöhe und hindert den wissenschaftlichen Fortschritt.
Ziel der vorliegenden Arbeit war die Entwicklung einer einfachen und schnellen Methode, die es trotzdem ermöglicht, die Identifikation von Antikörpern sicherzustellen. Dazu wurde eine Methode basierend auf dem "peptide mass fingerprinting" gewählt. Das Problem der unbekannten Aminosäuresequenz der Antikörper wurde gelöst, indem lediglich die Peptidmuster der entstehenden Fingerprint-Spektren zur Identifikation herangezogen wurden. MALDI wurde dabei als Ionisationsmethode für die Massenspektrometrie gewählt, da die resultierenden Spektren im Gegensatz zu ESI-MS einfach auszuwerten sind. Auch kann auf eine vorige Trennung der Peptide mittels LC verzichtet werden, was zusätzlich Analysenzeit spart. Für die Proteinspaltung wurde eine simple saure Hydrolyse mittels Ameisensäure gewählt. Im Vergleich zum herkömmlichen Trypsin-Verdau konnten auf zeitraubende Arbeitsschritte wie Denaturierung, Reduktion und Alkylierung der Antikörper verzichtet werden. Die Hydrolyse mittels Ameisensäure wurde bisher nur auf kleine und mittelgroße Proteine angewendet, sodass im ersten Teil dieser Arbeit mehrere Schritte optimiert wurden bevor zufriedenstellende Fingerprint-Spektren von Antikörpern erhalten wurden.