Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Vortrag (7)
- Posterpräsentation (5)
- Buchkapitel (1)
Referierte Publikation
- nein (13) (entfernen)
Schlagworte
- Spectroscopy (13) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (4)
- 6 Materialchemie (4)
- 4 Material und Umwelt (3)
- 5 Werkstofftechnik (3)
- 5.0 Abteilungsleitung und andere (3)
- 6.3 Strukturanalytik (3)
- 1.2 Biophotonik (2)
- 1.6 Anorganische Referenzmaterialien (1)
- 1.9 Chemische und optische Sensorik (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
Eingeladener Vortrag
- nein (7)
Contamination of natural bodies of water with oil and lubricants (or generally, hydrocarbon derivatives such as petrol, fuel and others) is a commonly found phenomenon around the world due to the extensive production, transfer and use of fossil fuels. The timely identification of these contaminants is of utmost importance, since they directly affect water quality and represent a risk for wildlife and human health even in trace amounts.
In this work, we develop a simple system for the on-field detection of total petroleum hydrocarbons (TPH) in water and soil, the "Spectrocube". The test is based on the measurement of the fluorescence signal emitted by the molecular rotor 4-DNS-OH dye. This dye is embedded in a hydrophobic polymeric matrix (PVDF), avoiding interactions of water with the dye and providing a robust support for use in test-strip fashion. The test-strip’s fluorescence intensity increases linearly at low concentrations of TPH, reaching a saturation value at higher concentrations.
For excitation and evaluation of the test-strip fluorescence, a simple miniature optical system was designed. The system works semi-quantitatively as solvent-free TPH detection kit, as well as quantitatively when using a simple cyclopentane extraction step. To simplify the fluorescence read-out, the device is coupled to a tablet computer via Bluetooth, running a self-programmed software ("app").
The technique of painting on the reverse side of a glass panel was rediscovered by German artists at the beginning of the 20th century. They appreciated the impressive gloss, luminosity, and depth of colours in this genre. Compared to stained glass, the distinctive properties of this technique are: (1) the paint is applied “cold”, hence, it doesn’t involve a firing step, (2) reverse paintings on glass are framed and always viewed in reflected light and (3) the reverse paint stratigraphy is different from canvas paintings, starting with the front most layer and ending with the backing layer. In 1908 several artists, including Gabriele Münter, Wassily Kandinsky, Heinrich Campendonk, August Macke and Franz Marc of the “Der Blaue Reiter” (the Blue Rider) collective took an interest in this technique and started to share their interest with other colleagues in Europe. Our pioneering project is tracing this transfer of knowledge by a multidisciplinary approach in terms of art history, paint technology and material science. More than 100 artists and >1000 reverse paintings on glass were identified during the project. This high number of objects clearly points out that this technique was by far more important for modern art than previously assumed. In-situ, non-invasive measurements (XRF, Raman, VIS, DRIFTS) on a well-considered selection of 67 paintings reveal the broad palette of colorants ranging from traditional to experimental. Special attention is paid to the impact of synthetic organic pigments (SOP) in artists palette. Demonstrative examples by W. Kandinsky, L. G. Buchheim and F. Jespers are used to discuss analytical challenges and highlights.
A wide range of methods are used to estimate the plant-availability of soil phosphorus (P). Published research has shown that the diffusive gradients in thin films (DGT) technique has a superior correlation to plant-available P in soils compared to standard chemical extraction tests. In order to identify the plant-available soil P species, we combined DGT with infrared and P K- and L-edge X-ray adsorption near-edge structure (XANES) spectroscopy. This was achieved by spectroscopically investigating the dried binding layer of DGT devices after soil deployment. All three spectroscopic methods were able to distinguish between different kinds of phosphates (poly-, trimeta-, pyro- and orthophosphate) on the DGT binding layer. However, infrared spectroscopy was most sensitive to distinguish between different types of adsorbed inorganic and organic phosphates. Additionally, also intermediates of the time-resolved hydrolysis of trimetaphosphate in soil could be analyzed. Furthermore, infrared and XANES microspectroscopy make it also possible to analyze P compounds on the binding layer with a lateral resolution down to 1 µm2. Therefore, P species of a spatial soil segment (e.g. rhizosphere) can be mapped and analyzed.
We developed a setup for time- and lateral-resolved X-ray absorption fine structure (XAFS) spectroscopy. A dispersive element is placed behind the sample to investigate. The broadband incoming beam transmits the sample, is then dispersed and finally collected by a position sensitive detector. This allows the recording of a whole X-ray absorption near edge structure (XANES) or extended X-ray absorption fine structure (EXAFS) spectrum in a single shot. The dispersive element is a Si(111) crystal, bent by means of a so called wafer bender, developed in house. Our setup is very flexible, easy to adjust and allows a time resolution down to one second which can be used to follow chemical reactions with dynamics on this time scale.
In civil engineering, the investigation of existing infrastructure is of major importance for maintaining and ensuring stability of the structures. To ensure durability, uniform regulations and standards apply e.g. the European standard EN 206-1. In some countries, the EN-standard is supplemented by additional standards, as in Germany with DIN 1045-2. Here, specific application rules are described, e.g. for the cement type, to ensure the resistant to different exposures. Therefore, the knowledge of the materials originally used is important in assessing the condition of existing concrete structure. Unfortunately, these are often unknown and must be determined retrospectively. Therefore, we present the application of the laser-induced breakdown spectroscopy to distinguish between different types of cement. Spectral information’s are used to build a classification model. First, the accuracy of the classification is analyzed on ten pure laboratory cement samples. To investigate possible sources of error, the model was then applied to cement samples with different moisture content. The study shows that LIBS is a promising tool for distinguishing between cement types. For further industrial application, however, factors influencing the LIBS signal must be included to ensure a robust model.
Our aim is to develop a new simple and inexpensive method for full field X-ray fluorescence imaging . We combine an energy dispersive array detector with a coded aperture to obtain high resolution images . To obtain the information from the recorded image a reconstruction step is necessary . The reconstruction methods we have developed , were tested on simulated data and then applied to experimental data . The first tests were carried out at the BAM line @ BESSY II. This method enables the simultaneous detection of multiple elements , which is important e.g. in the field of catalysis.
Die metallischen Verunreinigungen in Metallen lassen sich mittels hochauflösender Massenspektrometer relativ einfach ermitteln. Die Glimmentladungs-Massenspektrometrie (GD-MS) stellt hierfür eine schnelle Multielementmethode dar. Aufgrund ihrer höheren Anregungs- und Ionisationsenergien ist die Bestimmung von Nichtmetallen eine weit größere Herausforderung. Außerdem fehlt es an für die direkte Feststofftechnik notwendigen Kalibrierstandards z.B. in Form zertifizierter Referenzmaterialien. Für die quantitative Bestimmung von Verunreinigungen wurden mit Standards dotierte Pulverpresslinge und dotierte, gesinterte Materialien auf ihre Eignung als Kalibrierstandards für die GD-MS untersucht. Dabei kamen unterschiedliche Plasmabedingungen (gepulster/ kontinuierlicher Betrieb; verschiedene Plasmagase) zum Einsatz. Ein Überblick über analytische Kenngrößen und Grenzen der verwendeten Kalibrierstrategien wird gegeben. Zur Validierung des Verfahrens wurde die hochauflösende Continuum Source Absorptionsspektrometrie (HR-CS-MAAS) verwendet. Die analytische Nutzung der Molekül-absorptionsspektrometrie zur Bestimmung von Halogenen basiert auf der Bildung insitu-generierter zweiatomiger Moleküle (AlCl, GaF). Die entstehenden Molekülspektren werden im Echelle-Spektrometer aufgespalten und mittels CCD-Array detektiert, was eine sehr empfindliche Messung und präzise Quantifizierung ermöglicht.
High-temperature corrosion is a widespread problem in various industries.
As soon as a hot and reactive gas (CO2, O2, H2O, SO2, NOx, etc.) is in contact with a solid, physico-chemical processes at the surface and interfaces lead to material degradation. The processes are dynamic and controlled by thermodynamic and kinetic boundary conditions. Whether a reaction product is protective or not depends on various factors, such as chemical composition of the solid and the reactive media, surface treatment as well as diffusion and transport paths of cations and anions. Resulting chemical and structural inhomogeneities with the corrosion layers are characterized by off stoichiometry within cationic and anionic sub lattices. The competitive processes can be studied by various techniques of applied crystallography.
This chapter gives an overview on the challenges of chemical-structural Analysis of reaction products by crystallographic methods such as X-ray diffraction and X-ray near-edge structure spectroscopy and scanning electron microscopy electron backscatter diffraction (SEM-EBSD) for corrosion science.