Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2020 (8) (entfernen)
Dokumenttyp
- Vortrag (8) (entfernen)
Sprache
- Englisch (8) (entfernen)
Referierte Publikation
- nein (8)
Schlagworte
- Reference materials (3)
- Dye (2)
- EMPIR 18HLT01 MetVesII (2)
- Extracellular vesicles (EV) (2)
- Flow cytometry (FCM) (2)
- Fluorescence (2)
- Fluorescent particles (2)
- Integrating sphere spectroscopy (2)
- Measurement uncertainty (2)
- Method (2)
- Nano particle (2)
- Quality assurance (2)
- Aaerosol particles (1)
- Airborne particulate pollutants (1)
- Assay (1)
- Characterization (1)
- Core/shell particle (1)
- Electron microscopy (1)
- Fluorescence microscopy (1)
- Fluorescence quantum yield (1)
- Fluorescence spectroscopy (1)
- Fluorescence standard (1)
- Fluorescent glasses (1)
- Instrument calibration (1)
- Iron oxide nanoparticles (1)
- Linearity (1)
- Method development (1)
- Multiplexing (1)
- Nanoplattform (1)
- Optical probes (1)
- Particle size (1)
- Particle, imaging (1)
- Quantification (1)
- Quantitative spectroscopy (1)
- Quantum yield (1)
- Reference material (1)
- Risk assessment (1)
- Safety (1)
- Sensor molecules (1)
- Single particle spectroscopy (1)
- fluorescence standards (1)
- surface group analysis (1)
- synthesis (1)
Organisationseinheit der BAM
- 1.2 Biophotonik (8) (entfernen)
Eingeladener Vortrag
- nein (8)
Monodisperse iron oxide nanoparticles as reference material candidate for particle size measurements
(2020)
In order to utilize and rationally design materials at the nanoscale the reliable characterization of their physico-chemical properties is highly important, especially with respect to the assessment of their environmental or biological impact. Furthermore, the European Commission’s REACH Regulations require the registration of nanomaterials traded in quantities of at least 1 ton. Powders or dispersions where 50% (number distribution) of the constituent particles have sizes ≤ 100 nm in at least one dimension are defined as nanomaterials. This creates a need for industrial manufacturers and research or analytical service facilities to reliably characterize potential nanomaterials. Currently, BAM is developing reference nanoparticles, which shall expand the scarce list of worldwide available nano reference materials certified for particle size distribution and will also target other key parameters like shape, structure, porosity or functional properties. In this respect, materials like iron oxide or titanium dioxide are considered as candidates to complement the already available silica, Au, Ag, and polystyrene reference nanoparticles.
The thermal decomposition of iron oleate precursors in high boiling organic solvents can provide large quantities of iron oxide nanoparticles that can be varied in size and shape.[1, 2] The presence of oleic acid or other hydrophobic ligands as capping agents ensures stable dispersion in nonpolar solvents. Such monodisperse, spherical particles were synthesized at BAM and pre-characterized by electron microscopy (TEM, SEM including the transmission mode STEM-in-SEM) and dynamic light scattering comparing cumulants analysis and frequency power spectrum.
1. REACH regulations and nanosafety concerns create a strong need for nano reference materials with diverse properties.
2. Iron oxide nanoparticles are under development as new candidate reference material at BAM.
3. Narrow particle size distribution confirmed by light scattering and electron microscopy.
Standardisation of concentration measurements of extracellular vesicles for medical diagnoses
(2020)
Extracellular vesicles (EVs) are cell-derived particles in body fluids, which have excellent potential as next generation biomarkers for the early diagnosis of common diseases, such as cancer and thrombosis. This project aims to tap into the clinical potential of EVs by developing traceable measurements of number concentration, size distribution, refractive index (RI) and fluorescence intensity of cell-specific EVs in human blood and urine.
To realise our aims, we will develop synthetic reference materials with physical properties resembling EVs (WP1), instrumentation and procedures to standardise EV measurements in clinical laboratories (WP2), and ready-to-use biological test samples (WP3). These will then be evaluated in an inter-laboratory comparison study across a range (>20) of standard flow cytometers in clinical labs (WP4).
A brief perspective of BAM on advanced materials is presented including examples for nanomaterials and other systems presenting advanced materials with special emphasis on characterization methods used in different division of BAM for the determination of functional or safety parameters of such materials. In this respect, also ongoing activities of the capacity building project nanoplatform of BAM aiming at the development of nanometer-sized reference materials are briefly summarized.
A brief introduction to fluorescence spectroscopy will be provided, ranging from typically measured fluorescence quantities over instrument-specific contributions to measured fluorescence signals to selected applications. In this context, an overview of the photoluminescence properties of molecular and nanoscale luminescence reporters will be given including a brief insight into their photophysics and fluorescence standards designed by division Biophotonics for the calibration and instrument performance validation of fluorescence measuring devices will be presented.
Research of division Biophotonics at the Federal Institute for Materials Research and Testing (BAM) covers several topics including photophysics of molecular and nanocrystalline emitters, the development of signal enhancement, multiplexing, and barcoding strategies, surface group quantification, the rational design of different types of stimuli-responsive optical probes, and concepts and reference materials for the validation of optical-spectroscopic measurements. In the following representative examples for each of these topics are given. Also, current developments like single particle spectroscopy and flow cytometry with lifetime detection and newly certified fluorescence quantum yield standards are presented.
Aiming at the development of a non-destructive optical measurement methods for the characterization of nano-sized airborne particulate pollutants we performed fluorescence spectroscopic investigations of their relevant emission properties. Here, we present first results from studies of soot particles from synthetic aerosols deposited on PTFE membranes.
The aim of task 1.4 within the EMPIR project 18HLT01 MetVesII is to produce low-RI solid particles with an effective RI between 1.37 and 1.42. To prepare these low-RI solid particles, polymer cores will be coated with a silica shell. Although the bulk RI of polymers, such as polystyrene (RI = 1.59) and PMMA (RI = 1.49), and fused silica (RI = 1.46) are higher than desired, an effective RI below 1.42 will be achieved by using a mesoporous silica shell with tuneable shell-thickness and a polymer core with sufficiently small size. This approach has four advantages: (1) monodisperse commercial polymer particles and silica shell chemistry are available, (2) low-RI solid particles will have a tuneable size and RI, (3) fluorescence can be added by incorporating fluorescent dyes into the polymer cores via an established staining procedure, and (4) fluorescent dyes within the polymer cores are shielded against influences from the sample matrix, e.g. fluorescence quenching effects altering the emission properties of the reference materials.
Photoluminescence techniques are amongst the most widely used tools in the life sciences, with new and exciting applications in medical diagnostics and molecular imaging continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. General drawbacks are, however, signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are also time-dependent due to aging of instrument-components, and difficulties to measure absolute fluorescence intensities. Moreover, scattering systems require special measurement geometries and the interest in new optical reporters with emission > 1000 nm strategies for reliable measurements in the second diagnostic for the comparison of material performance and the rational design of new fluorophores with improved properties.
Here, we present strategies to versatile method-adaptable liquid and solid fluorescence standards for different fluorescence parameters. Examples are multi-emitter glasses, spectral fluorescence standards, and quantum yield standards for the UV/vis/NIR.