Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (1456)
- Zeitschriftenartikel (1264)
- Posterpräsentation (524)
- Beitrag zu einem Tagungsband (267)
- Sonstiges (64)
- Forschungsdatensatz (56)
- Forschungsbericht (36)
- Buchkapitel (33)
- Dissertation (20)
- Beitrag zu einem Sammelband (17)
Sprache
- Englisch (3093)
- Deutsch (657)
- Mehrsprachig (10)
- Spanisch (5)
- Russisch (4)
- Französisch (2)
- Italienisch (1)
- Polnisch (1)
Schlagworte
- Nanoparticles (120)
- Fluorescence (116)
- LIBS (102)
- Concrete (91)
- Quantum yield (80)
- Ultrasound (76)
- Mechanochemistry (74)
- NDT (71)
- Non-destructive testing (70)
- SAXS (70)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1237)
- 8 Zerstörungsfreie Prüfung (1118)
- 6 Materialchemie (1086)
- 6.1 Oberflächen- und Dünnschichtanalyse (368)
- 6.3 Strukturanalytik (346)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (326)
- 1.1 Anorganische Spurenanalytik (306)
- 8.4 Akustische und elektromagnetische Verfahren (259)
- 4 Material und Umwelt (234)
- 1.2 Biophotonik (226)
- 6.6 Physik und chemische Analytik der Polymere (210)
- 1.4 Prozessanalytik (202)
- 8.0 Abteilungsleitung und andere (201)
- 8.5 Röntgenbildgebung (196)
- 1.7 Organische Spuren- und Lebensmittelanalytik (144)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (142)
- 8.3 Thermografische Verfahren (135)
- 1.8 Umweltanalytik (127)
- 7 Bauwerkssicherheit (121)
- S Qualitätsinfrastruktur (119)
- 1.6 Anorganische Referenzmaterialien (117)
- 4.5 Kunst- und Kulturgutanalyse (108)
- 1.9 Chemische und optische Sensorik (101)
- S.2 Digitalisierung der Qualitätsinfrastruktur (95)
- 6.7 Materialsynthese und Design (86)
- 1.5 Proteinanalytik (80)
- 5 Werkstofftechnik (80)
- 1.3 Instrumentelle Analytik (70)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (59)
- VP Vizepräsident (49)
- VP.1 eScience (49)
- 2 Prozess- und Anlagensicherheit (46)
- 9 Komponentensicherheit (46)
- 4.3 Schadstofftransfer und Umwelttechnologien (45)
- P Präsident (43)
- 4.2 Material-Mikrobiom Wechselwirkungen (42)
- P.0 Präsident und andere (39)
- 5.1 Mikrostruktur Design und Degradation (38)
- 4.1 Biologische Materialschädigung und Referenzorganismen (37)
- 6.0 Abteilungsleitung und andere (37)
- 7.6 Korrosion und Korrosionsschutz (37)
- 1.0 Abteilungsleitung und andere (36)
- 2.1 Sicherheit von Energieträgern (30)
- 7.4 Baustofftechnologie (29)
- 3 Gefahrgutumschließungen; Energiespeicher (28)
- 6.2 Material- und Oberflächentechnologien (28)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (25)
- 7.1 Baustoffe (24)
- 8.6 Faseroptische Sensorik (24)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (23)
- 9.0 Abteilungsleitung und andere (22)
- S.1 Qualität im Prüfwesen (20)
- 9.4 Integrität von Schweißverbindungen (13)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (12)
- 5.4 Multimateriale Fertigungsprozesse (12)
- 5.2 Metallische Hochtemperaturwerkstoffe (11)
- 5.3 Polymere Verbundwerkstoffe (10)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (9)
- 3.2 Gefahrguttanks und Unfallmechanik (9)
- 4.0 Abteilungsleitung und andere (9)
- 5.0 Abteilungsleitung und andere (9)
- 9.6 Additive Fertigung metallischer Komponenten (9)
- 9.5 Tribologie und Verschleißschutz (8)
- 9.2 Versuchsanlagen und Prüftechnik (7)
- PST Präsidiale Stabsstelle (7)
- 2.0 Abteilungsleitung und andere (5)
- 3.5 Sicherheit von Gasspeichern (5)
- 7.0 Abteilungsleitung und andere (5)
- 7.2 Ingenieurbau (5)
- 5.6 Glas (3)
- S.0 Abteilungsleitung und andere (3)
- VP.2 Informationstechnik (3)
- 2.3 Einstufung von Gefahrstoffen und -gütern (2)
- 3.6 Elektrochemische Energiematerialien (2)
- 7.3 Brandingenieurwesen (2)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- Z Zentrale Dienstleistungen (2)
- Z.1 Organisation, Controlling (2)
- 3.4 Sicherheit von Lagerbehältern (1)
- 5.5 Materialmodellierung (1)
- 7.7 Modellierung und Simulation (1)
- MP Mitglied des Präsidiums (1)
- MP.0 Mitglied des Präsidiums und andere (1)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (1)
Paper des Monats
- ja (27)
Small variations in the isotopic composition of some elements have been used as proof of provenance of mineral and biological samples, to describe geological processes, and to estimate a contamination source. Routinely, isotope compositions are measured by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time-consuming and they require a high qualified analyst.
Here, an alternative faster and low-cost optical method for isotope ratio determination is investigated: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X = Li, B, Mg, Ca and Sr have been determined by monitoring the absorption spectra of their in situ generated hydrides (XH) in graphite furnace HR-CS-MAS. For example, the system of two stable isotopes of boron (10B and 11B) was studied via its hydride for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, isotopic composition of samples and reference materials are calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results are metrologically compatible with those reported by mass spectrometric methods. [1] Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shift of their isotopologues can be resolved as shown in Fig.1 b. The extension of this methodology to other elements like Li, Ca and Sr is discussed [2].
References:
[1] C. Abad, S. Florek, H. Becker-Ross, M.-D. Huang, H.-J. Heinrich, S. Recknagel, J. Vogl, N. Jakubowski, U. Panne, Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers, Spectrochim. Acta, Part B, 136 (2017) 116-122.
[2] C. Abad et al., unpublished results, 2018.
Following fluorinated drugs by molecular absorption spectrometry – from cancer cells to body fluids
(2018)
Fluorine has been widely introduced into pharmaceutical drugs. Due to the high C-F bond strength, a single atom substitution with fluorine produces drastic desirable and tunable changes in the molecular properties. However, the clinical monitoring of these drugs is not straightforward.
Organofluorine compounds are elusive for a non-targeted analysis; a significant problem in fluorine determination is the lack of suitable detection techniques. Standard atomic absorption and emission spectrometers cannot access fluorine, because their resonance lines lie in the VUV spectral range below 100 nm. In the case of conventional inductively coupled argon plasmas (ICP), the plasma energy is too low to generate a significant population of excited fluorine atoms. Recently, our group introduces high-resolution continuum source absorption spectrometry (HR-CS MAS) as a new way for the indirect monitoring of fluorinated compounds. Main benefits of HR-CS-MAS includes low limits of detection, complete analyte recovery, simple to no sample preparation, and short time analysis.
We propose an alternative faster and low-cost optical method for isotope analysis: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS).
Stable isotope amount composition of X = Li, B, Mg, Ca and Sr were determined by monitoring the absorption spectra of their in situ generated mono-hydrides (XH) in graphite furnace HR-CS-MAS. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results with an accuracy of 0.15 ‰ are metrologically compatible with those reported by mass spectrometric methods. Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved as shown in Fig.1b. The extension of this methodology to other elements like Li, Ca and Sr is discussed.
Mass spectrometric methods (MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
We propose a lower-cost and faster optical alternative for the analysis of isotope ratios of selected elements: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated mono-hydrides and halide (MH and MX) using graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. The extension of this methodology to other elements like Li, Ca, Cu, and Sr is discussed.
Advances and Applications of Molecular Absorption Spectrometry: from Non-Metals to Isotope Analysis
(2020)
The present work covers two main aspects of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS), an analytical technique for elemental trace analysis.
First, a comprehensive mechanistic study of molecule formation in graphite furnaces is presented, which is a key step into the recovery of analytical signals. For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in HR-CS-GFMAS. A zirconium coating catalyzes the CaF formation, and its structure was investigated. The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. Here a mechanism is proposed, where ZrO2 works as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface.
Second, analytical methods were developed by using HR-CS-MAS as detector for non-metals and isotope analysis. Therefore, the determination of organic absorbable chlorine in water, the quantification of fluorine in consume care products with declared perfluorinated ingredients, and the determination of sulfur content in crude oils were investigated. Finally, the high resolution of the instrumentation allows to measure isotopic shifts with high precision in some observed molecular spectra. Consequently, the molecular spectra of enriched isotopes of boron and magnesium were investigated, establishing so the potential of HR-CS-MAS for the accurate and precise determination of isotopic amount ratios.
Isotope analysis can be used to determine the age and provenance of geological samples or to study dynamic systems like Li-ion batteries. Modern techniques in optical spectrometry allow us a fast and slow-cost isotope analysis. These techniques include high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS) and laser ablation molecular isotopic spectrometry. This seminar will discuss our recent work on precise and accurate isotope analysis of boron, magnesium, and lithium with geology, climate, and energy research applications.
Wie lässt sich die Herkunft von Rohstoffen, Lebensmitteln oder Umweltschadstoffen einfacher, schneller und kostengünstiger als mit bisherigen Methoden bestimmen?
Die Dissertation zeigt auf, dass man das grundlegende physikalische Prinzip einer Isotopverschiebung mit in Adlershof entwickelten Optik-Instrumenten für die Herkunftsbestimmung nutzen kann. Die entwickelte Methode ermöglicht es in Zukunft den Ursprung von Rohstoffen, Lebensmitteln oder Umweltschadstoffen kostengünstiger und wesentlich schneller bestimmen, als dies mit bisherigen Methoden möglich ist.
Kann man das grundlegende physikalische Prinzip einer Isotopieverschiebung mit einem Optik-Instrument für die Herkunftsbestimmung nutzen? Carlos Abad hat eine wegweisende Methode entwickelt, die es in Zukunft ermöglicht den Ursprung von Rohstoffen, Lebensmitteln oder Umweltschadstoffen kostengünstiger und wesentlich schneller bestimmen, als dies mit bisherigen Techniken möglich ist.
Isotope analysis can be used to determine the age and provenance of geological samples. Modern techniques in optical spectrometry allow us a stand-off isotope analysis. This seminar will discuss how planetary science with the next Moon and Mars missions drive optical spectrometry into precise and accurate isotope analysis and how BAM will contribute.
Magnesium (Mg) is a major element in a range of silicate and carbonate minerals, the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg with natural abundances of 79 %, 10 %, and 11 %, respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight variations of isotope amount ratios n(26Mg)/n(24Mg) in biological, environmental and geological samples. Traditionally, isotope ratios are measured by mass spectrometric methods and isotope ratios are expressed as deviation from an internationally agreed upon material, i.e. the zero-point of the δ-value scale. Drawbacks of this method include the high costs for instruments and their operation, experienced operators and elaborate, time-consuming chromatographic sample preparation.
Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high- resolution continuum source graphite furnace molecular absorption spectrometry (HR- CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS).
For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X2Σ → A2Πi and X 2Σ → B2Σ+ around wavelengths 358 nm and 268 nm, respectively. In the case of LAMIS, we investigated the MgF molecule for the electronic transition A2Πi → X2Σ as well as the MgO molecule for the electronic transition A1Π+ → X1Σ around 500 nm. The MgF and MgO spectra are described by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by partial least square regression (PLS) calibrated with enriched isotope spikes. Isotope amount ratios in rock samples with and without matrix separation were analyzed. Calculated δ-values were accurate and obtained with precisions ranging between 0.2 ‰ and 0.5 ‰ (1 SD, n = 10). On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared to MC-ICP-MS.
Mass spectrometric Methods MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
Optical spectrometric methods are proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS) and laser ablation molecular isotopic spectrometry (LAMIS). First, stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated heteronuclear diatomic molecules (MH or MX) in graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. Finally, the application of molecular spectrometry via emission by LAMIS is compared and discussed.