Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (490)
- Vortrag (336)
- Posterpräsentation (205)
- Sonstiges (15)
- Forschungsdatensatz (11)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (4)
- Dissertation (4)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
- Forschungsbericht (2)
- Handbuch (1)
- Newsletter (1)
Sprache
- Englisch (1078) (entfernen)
Schlagworte
- Fluorescence (104)
- Quantum yield (69)
- Nanoparticle (52)
- ICP-MS (49)
- Quality assurance (49)
- Laser ablation (48)
- Dye (47)
- LIBS (41)
- Lifetime (41)
- Nano (41)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1078) (entfernen)
Paper des Monats
- ja (12)
Sr isotope ratio analysis
(2023)
Pb isotope ratio analysis
(2023)
Detector deadtime
(2023)
Isotope Ratio Analysis
(2023)
Here, we elucidate nonclassical multistep crystallization pathways of transition metal phosphates from aqueous solutions. We followed precipitation processes of M-struvites, NH4MPO4·6H2O, and M-phosphate octahydrates, M3(PO4)2·8H2O, where M = Ni, Co, or NixCo1–x, by using in situ scattering and spectroscopy-based techniques, supported by elemental mass spectrometry analyses and advanced electron microscopy. Ni and Co phosphates crystallize via intermediate colloidal amorphous nanophases, which change their complex structures while agglomerating, condensing, and densifying throughout the extended reaction times. We reconstructed the three-dimensional morphology of these precursors by employing cryo-electron tomography (cryo-ET). We found that the complex interplay between metastable amorphous colloids and protocrystalline units determines the reaction pathways. Ultimately, the same crystalline structure, such as struvite, is formed. However, the multistep process stages vary in complexity and can last from a few minutes to several hours depending on the selected transition metal(s), their concentration, and the Ni/Co ratio.
Surface functionalized silica nanoparticles (SiO2-NP) gained great interest in the life and material sciences, as they can be used e.g. as drug carriers, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. They are highly stable, are easily produced and modified on a large scale at low cost and can be labeled or stained with a multitude of sensor dyes. These dye modified particle conjugates have several advantages as compared to conventional molecular probes like enhanced brightness, ease of designing ratiometric systems by combining analyte-sensitive and inert reference dyes, and increased photostability. Moreover, stained nanoparticles can enable the use of hydrophobic dyes in aqueous environments.
Here we present our work on multicolored sensors for the measurement of pH, oxygen and saccharides utilizing amorphous SiO2 NPs.
In recent years, chromium (III) complexes have received a lot of attention as novel near-infrared (NIR) emitters triggered by the report on the first molecular ruby Cr(ddpd)2(BF4)3 with a high photoluminescence quantum yield of 13.7% of its near infrared (NIR) emission band and a long luminescence lifetime of 1.122 ms at room temperature.[1] However, in an oxygen-containing environment, the photoluminescence quantum yields and luminescence lifetimes of these chromium(III) complexes show only very small values. This hampers their application as NIR luminescence labels. This application, that cannot be tackled by conventional deoxygenating approaches, requires suitable strategies to protect the luminescence of the chromium(III) complexes from oxygen quenching. An elegant approach to reduce the undesired luminescence quenching by triplet oxygen explored by us presents the incorporation of these chromium(III) complexes into different types of amorphous, non-porous silica nanoparticles, that can be simply surface functionalized, e.g., with targeting ligands and/or other sensor molecules. In this work, as first proof-of-concept experiments, a set of chromium (III) complexes constituting of different ligands and counter anions, were embedded into the core of silica nanoparticles. Subsequently, the optical properties of the resulting luminescent silica nanoparticles were spectroscopically assessed by steady state and time-resolved luminescence spectroscopy. First results of time-resolved luminescence measurements confirm our design concept of nanoscale NIR emissive Cr(III) complex-based reporters
Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage which improve the quality of life and European prosperity. NP function, performance, interaction with biological species, and environmental fate are largely determined by their surface functionalities. Standardized repeatable surface characterization methods are therefore vital for quality control of NPs, and to meet increasing concerns regarding their safety. Therefore, industry, regulatory agencies, and policymakers need validated traceable measurement methods and reference materials. This calls for fit-for-purpose, validated, and standardized methods, and reference data and materials on the surface chemistry of engineered NPs. Here, we present a concept for the development of such standardized measurement protocols utilizing method cross-validation and interlaboratory comparisons (ILCs) with emphasis on both advanced measurement methods such as quantitative Nuclear Magnetic Resonance (qNMR), X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS) and cost-efficient, non-surface specific methods like optical assays and electrochemical titration methods.
Engineered and tailored nanomaterials (NM) are of great interest in the life and material sciences, as they can be used, e.g., as drug carriers, barcodes, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. Their performance and safety depend not only on their particle size, size distribution, and morphology, but also on their surface chemistry, i.e., the total number of surface functional groups (FG) and the number of FG accessible for subsequent functionalization with ligands or biomolecules, which in turn determines surface charge, colloidal stability, biocompatibility, and toxicity. It also underlines the importance of validated analytical methods that provide accurate information on these application-relevant physicochemical properties with a known uncertainty. In the case of FG quantification, this calls for robust, fast, inexpensive, and reliable methods which allow for the characterization of a broad variety of NM differing in size, chemical composition, and optical properties.
Methods
Aiming at the development of simple, versatile, and multimodal tools for the quantification of bioanalytically relevant FG such as amine, carboxy, thiol, and aldehyde functionalities, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance (NMR), mass spectrometry (MS), and thermal analysis methods.
Results
Here, we will present examples for different types of NMs and FGs including results from a currently running interlaboratory comparison (ILC) with the National Research Council of Canada (NRC) to pave the road for method standardization.
Innovative aspects
• Surface analysis
• Performance and safety of nanomaterials
• Standardization
Engineered nanomaterials (NM) with their large surface-to-volume ratios and their for some materials observed size-dependent functional properties are of increasing relevance for current and future developments in various fields such as medical and pharmaceutical industry, computing and electronics or food and consumer products. The performance and safety of NM are determined by the sum of their intrinsic physicochemical properties. Especially, the particle surface chemistry, which is largely controlled by the chemical nature and density of functional groups (FG) and ligands, is an important key driver for NM performance, stability, and processibility as well as the interaction of NM with the environment. Thus, methods for FG quantification can foster the sustainable development of functional and safe(r) NM.
Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made polymeric and silica particles of varying FG, used as optical pH sensors. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
In recent years, the use of functionalized micro- and nanomaterials has increased rapidly for a wide range of applications in the life and material sciences, due to their unique properties in combination with their high surface-to-volume ratio and stability. For instance, functionalized micro- and nanomaterials, that are labeled or stained with a multitude of sensor dyes can be used for monitoring, and quantification of neutral and ionic analytes. These materials have several advantages as compared to conventional molecular probes like enhanced brightness, ease of designing ratiometric systems by combining analyte-sensitive and inert reference dyes, and increased photostability. Moreover, stained nanoparticles can enable the use of hydrophobic dyes in aqueous environments.
Versatile templates and carriers for the fabrication of nanosensors by staining and/or labeling with different fluorophores and sensor molecules are biocompatible silica and polymeric particles, because they can be synthesized in large scales at low costs with different surface chemistries.
Here we present our work on multicolored sensors for the measurement of pH, oxygen and saccharides utilizing commercially available or in-house synthesized silica and polymeric particles.
Nowadays amorphous silica nanoparticles (SiO2-NP) are one of the most abundant engineered nanomaterials, that are highly stable and can be easily produced on a large scale at low cost. Surface functionalized SiO2-NP are of great interest in the life and material sciences, as they can be used e.g. as
drug carriers, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. Their performance in such applications depends not only on particle size, size distribution, and morphology, but also on surface chemistry, i.e. the total number of surface functional groups (FG)
and the number of FG accessible for subsequent functionalization with ligands or biomolecules, which in turn determines surface charge, colloidal stability, biocompatibility, and toxicity. Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made silica particles of varying FG, showing not only an influence of the synthesis methods on the number of FG but also on the performance. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
In the focus of division Biophotonics are the design, preparation, analytical and spectroscopic characterization, and application of molecular and nanoscale
functional materials, particularly materials with a photoluminescence in the visible, near infrared (NIR) and short-wave infrared (SWIR). This includes optical reporters for bioimaging and sensing, security and authentication barcodes, and materials for solid state lighting, energy conversion, and photovoltaics. For the identification of optimum particle structures quantitative spectroscopic studies are performed under application-relevant conditions, focusing on the key performance parameter photoluminescence quantum yield. In addition, simple, cost-efficient, and standardizable strategies for quantifying functional groups on the surface of nano- and microparticles are developed, here with a focus on optical assays and electrochemical titration methods, cross-validated by more advanced methods such as quantitative NMR. In addition, reference materials and reference products are developed for optical methods, particularly luminescence techniques, and for analytical methods utilized for the characterization of nanomaterials.
For fluorescence microscopy, there is an increasing need for suitable calibration tools and reference materials for microscope calibration, the determination of performance parameters, and the regular control and validation of instrument performance. This is addressed in the BmWk-financed project FluMikal (WIPANO program) by two research groups from academia and two companies, that is coordinated by BAM. Here we present different approaches to liquid and solid fluorescence standards for the determination of the wavelength-dependent spectral sensitivity of fluorescence microscopes and ideas concerning the choice of suitable fluorescence lifetime standard for increasingly utilized fluorescence lifetime imaging (FLIM).
Lanthanide Nanocrystals as Authentication and Security Tags and Reporters for Optical Sensors
(2023)
Counterfeiting of goods has serious economic implications worldwide and can present a considerable threat to human health and national security, rendering product authentication more and more important. This led to an increasing interest in simple tags for anticounterfeiting and authentication applications for the integration into different materials and matrices that are robust enough to survive the respective production processes and can be read out in-situ with simple instrumentation.
Here we present a platform of chemically inert, multi-color luminescent lanthanide nanocrystals (LnNC) consisting of a NaYF4 matrix doped with Yb, Er, Tm, or Ho as promising candidates for such applications.
LnNC with characteristic multi-color emission patterns, composed of narrow bands of varying intensity in the ultraviolet, visible, near-infrared, and short-wave were synthesized via a thermal decomposition approach under inert conditions[1]. The tailor-made design of different emission pattern was achieved by tuning particle size, material composition, and particle surface chemistry in upscaleable syntheses.[2] Particle size and morphology were determined by dynamic light scattering and transmission electron microscopy and the optical properties were characterized by absorption and fluorescence spectroscopy as well as fluorescence lifetime measurements.
The particles were then incorporated into security inks and consumer products. In addition, microenvironment-specific changes in the emission properties of the LnNC tag were utilized to study and sense changes of physico-chemical parameters in different matrices.
Counterfeiting of goods has serious economic implications worldwide and can be a threat to human health and safety. Upconversion nanoparticles (UCNPs)are ideal candidates for optical encoding of various materials. Particles with tailor-made emission patterns can be used as anti-counterfeiting markers and luminophores in security inks and to track material flows. Microenvironment-specific changes in the emission properties of the UCNP tags can be used to study, signal, and sense changes of physico-chemical parameters in different environments, e.g., building
materials.
Demonstrating competency and equivalence for the measurement capacity of contaminants and nutrients in primary foodstuffs is a priority of the OAWG 10-year strategy for Track A core comparisons. Such measurements have posed significant challenges for reference material producers and calibration service providers. This key comparison (KC), under the topic of “non- polar analyte in high carbohydrate food matrix: trans-Zearalenone (trans-ZEN) in maize powder” , was a sector of the model system selected to align with this class within the OAWG strategy. Evidence of successful participation in formal, relevant international comparisons is needed to demonstrate the Calibration and Measurement Capabilities (CMCs) of national metrology institutes (NMIs) and designated institutes (DIs).
17 NMIs and DIs participated in the Track A KC CCQM- 168 “non-polar analyte in high carbohydrate food matrix: trans-ZEN in maize powder” . Participants were requested to evaluate the mass fraction (μg/kg) of trans-ZEN in maize powder material. Methods like liquid-liquid extraction and SPE were applied in the pre-treatment, and HPLC-MS/MS and HPLC-FLD were used for detection by the participants. The mass fractions for trans-ZEN were in the range of (91.8 to 169) μg/kg with standard uncertainties of (1.5 to 24.7) μg/kg, and corresponding relative standard uncertainties from 1.5% to 14.6%. Two labs, INTI and BAM were excluded from the KCRV evaluation. INTI result was identified as an outlier and confirmed their method had insufficient specificity. For BAM the calibration approach they used does not meet the CIPM traceability requirements. The other 15 labs included in the calculation of the consensus KCRV all agreed within their standard uncertainties. Hierarchical Bayes was used as estimators in calculating KCRV and standard uncertainty.
Successful participation in CCQM-K168 demonstrates the measurement capabilities in determining mass fraction of organic compounds, with molecular mass of 100 g/mol to 500 g/mol, having low polarity pKow < -2, in mass fraction range from 1 μg/kg to 1000 μg/kg in a high carbohydrate food matrix.
Trace element (TE) analysis of pyrite via LA-ICP-MS can be used to reconstruct the conditions of pyrite formation in complex mineral systems. The Carpentaria province in northern Australia is host to some of the world’s highest value Zn-Pb (+Ag, Cu) deposits. The genesis of many of these deposits is controversial, with competing models of single-vs. multi-stage ore formation. In this study, LA-ICP-MS data of paragenetically constrained pyrite from the George Fisher Zn-Pb-Ag deposit has been analysed to investigate the chemistry of different stages of ore formation. Pyrite from correlative unmineralized host rocks has also been analysed to investigate evidence of distal hydrothermal anomalism. All LA-ICP-MS data have been statistically evaluated (principal component analysis) and interpreted together with whole rock lithogeochemical data of the same samples. Pre-ore diagenetic pyrite is compositionally similar to other Proterozoic diagenetic pyrite, with some evidence of minor hydrothermal anomalism that with further analysis could help define distal alteration. Pyrite from the different ore stages are compositionally distinct, consistent with a multi-stage system. Ore stage 1 pyrite exceeds background contents of Co, Cu, Zn, As, Ag, Sb, Tl, and Pb and has elevated Co/Ni ratios, whereas only Ni and Co are above background abundances in ore stage 2 and 3 pyrite, of which only ore stage 3 pyrite has high Co/Ni ratios. Ore stage 1 pyrite has a similar composition to hydrothermal pyrite in the undeformed northern Carpentaria CD-type deposits and was likely syn-diagenesis. Ore stage 2 was syn-deformation, and resulted in replacement and recrystallization of pre-existing pyrite, and the expulsion of incompatible TEs. Ore stage 3 formed via a later Cu-Zn-Pb mineralizing event that resulted in a new geochemically distinct generation of Co-rich pyrite. Overall, this study demonstrates the value of paragenetically-constrained pyrite TE data for refining genetic models in complex sediment hosted mineral systems.
AbstractThe minor and trace element composition of minerals provides critical insights into a variety of geological processes. Multi-element mapping by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is an important technique applied for this purpose and although the method is rapidly advancing, there remains a fundamental compromise between spatial resolution, detection limit, and experiment duration when using sequential mass analyzers. To address the limitation of limited analyte selection for high spatial resolution maps imposed by the sequential nature of typical quadrupole (Q)-ICP-MS, we tested the Aerosol Rapid Introduction System (ARIS) for repeat mapping of the same area. The ARIS is a high-speed transfer tubing system that reduces aerosol washout times, permitting resolution of individual pulses at 40–60 Hz. Here, the ARIS was tested not for pulse resolution but with novel operating conditions optimized to perform fast, high spatial resolution mapping of minor and trace element distribution in pyrite and marcasite. For this purpose, ablation was conducted with a 5 µm beam aperture, a repetition rate of 50 Hz, and a continuous stage scan speed of 40 µm s−1. For each LA-Q-ICP-MS map, data were acquired for six elements with an acquisition time of 20 ms per element. This deliberately reduced the individual pulse resolution of the ARIS but instead exploited the spatial resolution and sensitivity gains afforded by the high-laser repetition rate combined with efficient aerosol transfer. The new method successfully mapped trace elements at single to double-digit parts per million levels, and the maps reveal fine-scale zoning of trace elements with an effective x and y resolution of 5 µm, while white light interferometry showed that for each experiment, only ca. 1 µm of the sample was removed. Repeated mapping of the same area showed excellent correspondence not only between element concentrations in successive experiments but also in the shape, dimension, and location of regions of interest defined by concentration criteria. The very good repeatability of the elemental maps indicates that for studies requiring more analytes, successive mapping of additional elements is possible. By contrast with conventional very small spot (i.e., 5 µm) analysis, fast repetition rate and stage scan speed mapping avoids down-hole fractionation effects and minimizes accidental analysis of buried invisible inclusions. Compared to conventional LA-ICP-MS mapping, the method reduces the experiment time by 4–8 times.
Molten sulfur is found in various subaerial volcanoes. However, limited records of the pools and flows of molten sulfur have been reported: therefore, questions remain regarding the physicochemical processes behind this phenomenon. A suite of new sulfur flows, some of which active, was identified at the Lastarria volcano (northern Chile) and studied using satellite imagery, in situ probing, and temperature and video recording. This finding provides a unique opportunity to better understand the emplacement mechanisms and mineral and chemical compositions of molten sulfur, in addition to gaining insight into its origin. Molten sulfur presented temperatures of 124–158°C, with the most prolonged sulfur flow reaching 12 m from the source. Photogrammetric tools permitted the identification of levees and channel structures, with an estimated average flow speed of 0.069 m/s. Field measurements yielded a total volume of 1.45 ± 0.29 m3 of sulfur (equivalent to ∼2.07 tons) mobilized during the January 2019 event for at least 408 min. Solidified sulfur was composed of native sulfur with minor galena and arsenic- and iodine-bearing minerals. Trace element analysis indicated substantial enrichment of Bi, Sb, Sn, Cd, as well as a very high concentration of As (&gt;40.000 ppm). The January 2019 molten sulfur manifestations in Lastarria appear to be more enriched in As compared to the worldwide known volcanoes with molten sulfur records, such as the Shiretoko-Iozan and Poás volcanoes. Furthermore, their rheological properties suggest that the “time of activity” in events such as this could be underestimated as flows in Lastarria have moved significantly slower than previously thought. The origin of molten sulfur is ascribed to the favorable S-rich chemistry of fumarolic gases and changes in host rock permeability (fracture opening). Molten sulfur in Lastarria correlates with a peak in activity characterized by high emissions of SO2 and other acid species, such as HF and HCl, in addition to ground deformation. Consequently, molten sulfur was framed within a period of volcanic unrest in Lastarria, triggered by changes in the magmatic-hydrothermal system. The appearance of molten sulfur is related to physicochemical perturbations inside the volcanic system and is perhaps a precursor of eruptive activity, as observed in the Poás and Turrialba volcanoes.
The application of compact NMR instruments to continuously flowing samples at higher temperatures or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is typically not designed for compensation of such effects. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements using an optical thermo-graphy setup, a model predictive control was set up to minimize any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, potentially extend the application of compact NMR instruments to flowing samples at higher temperature than the permanent magnet.
High polarity analyte(s) in aqueous media: determination of L-PFOA and L-PFOS in ground water
(2022)
The CCQM-K156 comparison was coordinated by TUBITAK UME on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA).
Perfluoro alkyl substances (PFAS) such as PFOS and PFOA have been used in numerous industrial applications and products. Because of their high stability and resistance to biodegradation, atmospheric photooxidation, direct photolysis and hydrolysis, they are extremely persistent in the environment. The European Union (EU) Water Framework Directive lists PFOS as a priority hazardous substance that poses a significant risk to the aquatic environment. The use of PFOS-containing Aqueous Film-Forming Foams (AFFFs) has been banned since June 2011 in the EU. As relatively water-soluble, effectively non-degradable compounds, PFOS and PFOA migrate to ground water. They are not removed in the conventional drinking water treatment, and therefore cause health risks in polluted areas. The EU Drinking Water Directive and the European Commission has proposed a limit value of 100 ng/L for the sum of 20 PFAS, including PFOS and PFOA.
This study provides the means for assessing measurement capabilities for determination of high polarity measurands in a procedure that requires extraction, clean-up, analytical separation and detection. Successful participation in CCQM-K156 demonstrates measurement capabilities in determining mass fraction of organic compounds, with a molecular mass of 200 g/mol to 700 g/mol, having high polarity pKow -2, in a mass fraction range from 0.5 ng/kg to 500 ng/kg in aqueous media.
Nine NMIs and DIs participated in the CCQM-K156 key comparison. Seven institutes reported their results. SPE was applied in the sample pre-treatment and LC-MS was applied for detection. All participating laboratories applied isotope dilution mass spectrometry (IDMS) techniques for quantification. Participants established the metrological traceability of their results using certified reference materials (CRMs) from NMIs with stated traceability; where commercially available high purity materials were used the purity was determined in-house. The CCQM-K156 results for L-PFOA and L-PFOS range from 2.75 ng/kg to 5.50 ng/kg with a % RSD of 19.5 % for L-PFOA and from 2.04 ng/kg to 4.45 ng/kg with a % RSD of 21.3 % for L-PFOS. The KCRV was assigned using a Hierarchical Bayesian Random Effects Model (HB REM) estimator from the values reported by six of the participants. One participant result of L-PFOS and one result of L-PFOA were excluded from the KCRV for technical reasons. The KCRV was 4.9 ng/kg ± 0.4 ng/kg for L-PFOA and 3.8 ng/kg ± 0.4 ng/kg for L-PFOS. The six institutes that were included in the assignment of consensus KCRV all agreed within their standard uncertainties.
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
AbstractIn this study, we present a screening method based on molecular absorption spectrometry to study PFAS uptake and fate in plants. To evaluate the suitability of this method we analyzed plant extracts with molecular absorption spectrometry (MAS) as well as liquid chromatography–tandem mass spectrometry (LC–MS/MS) for mass balance studies (w(F)). French bean plants (Phaseolus vulgaris) were grown on soil spiked using eight PFAS substances that vary in chain length and functional group composition. Specifically, these include three short-chained (C4–C5), five long-chained (C7–C10) carboxylic acids, one sulfonic acid and one sulfonic amide moieties. To investigate substance-specific PFAS uptake systematically, PFAS were spiked as single substance spike. Additionally, we studied one mixture of the investigated substances in equal proportions regarding w(F) and four PFAS mixtures of unknown composition. After 6 weeks, the plants were separated into four compartments. We analyzed the four compartments as well as the soil for extractable organically bound fluorine (EOF) by high resolution-continuum source-graphite furnace-molecular absorption spectrometry (HR-CS-GFMAS) as well as for sum of ten target-PFAS by LC–MS/MS. All three short-chained PFAS perfluorobutanoic acid (PFBA), perfluorobutanoic sulfonic acid (PFBS) and perfluoropentanoic acid (PFPeA) were determined in high concentrations mainly in the fruits of the investigated plants while long-chained PFAS perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA) were mainly determined in roots. PFBS was determined in remarkably high concentrations in leaves compartment by both quantification methods. Overall, comprehensive results of single substance spikes were in good agreement for both methods except for a few cases. Hence, two phenomena were identified: for mixed PFAS spikes of unknown composition huge differences between EOF and sum of target PFAS were observed with systematically higher EOF values. Overall, both methods indicate comparable results with MS being more reliable for known PFAS contamination and MAS being more valuable to identify PFAS exposure of unknown composition.
Graphical Abstract
Referenzmaterialien sind unter anderem ein wichtiges Werkzeug zur Qualitätskontrolle von Messungen bestimmter Merkmalswerte. Dabei ist zu berücksichtigen, dass zertifizierte Merkmalswerte immer eine gewisse Unsicherheit haben. Die Ermittlung dieser Unsicherheitsbeiträge ist Gegenstand des Vortrags. Referenzmaterialien sind gleichzeitig ein wertvolles Werkzeug zur Ermittlung der Unsicherheit von Messverfahren und -Analysen unbekannter Proben. Die Vorgehensweise bei der Ermittlung der Messunsicherheit mit Hilfe eines Referenzmaterials wird beschrieben.
The possibility of obtaining high-purity, isotopically modified and nanostructured elemental substances 29Si, 98Mo, and 100Mo, as well as 98Mox10By compounds from volatile halides under conditions of laser optical breakdown of a pulsed Nd:YAG laser is shown. Currently, research in the field of developing new methods for obtaining high-purity, isotopically modified and nanostructured substances is being actively conducted. Interest in Si and Mo combining these forms has noticeably increased. In nuclear medicine, 29Si-enriched nanoparticles can be used as contrast agents in magnetic resonance imaging (MRI), and 98Mo and 100Mo isotopes can be used to obtain the unstable 99mTc radioisotope. These applications do not require large amounts of isotopically modified Si and Mo. Their obtaining belongs to the problems of small chemistry. When obtaining isotopically modified Si and Mo, it is expedient to use their volatile fluorides, for which technologies of isotope enrichment and deep purification are well developed. These halides have high chemical and thermal stability; therefore, plasma-chemical methods based on the plasma of a pulsed discharge generated by laser breakdown can be promising for separating 29Si, 98Mo, and 100Mo from them. Laser breakdown in H2+Ar+SiF4 and H2+Ar+MoF6 mixtures in various stoichiometric ratios in the pressure range 30–760 Torr was carried out using a pulsed Nd:YAG laser. The pulse duration at a wavelength of 1064 nm was 15 ns, the repetition rate was 5 Hz. A pulse energy of 800 mJ was focused by a lens with a focal length of 5 cm. The energy density at the focus was 26 J/cm3 . It has been shown that when using a mixture based on 29SiF4, the sample contains a 29Si crystalline phase with an average grain size of 30–50 nm (Fig. 1a). When using a mixture based on 98MoF6, the sample contains a 98Mo crystalline phase with an average grain size of 70–100 nm (Fig. 1b). In this type of gas discharge, the possibility of forming superhard materials, isotopically modified molybdenum borides, was also studied. These substances in the form of nanosized particles have improved tribological properties. After ablation of metallic Mo in the H2 + BF3 mixture, the main phase was MoB2 in the form of a nanodispersed powder with an average grain size of 100 nm (Fig. 1c) [1]. A technique for modeling gas-dynamic and thermal conditions in a low-temperature chemically active plasma induced by laser breakdown is proposed. Using computational experiments, the features of gas mixture heating and the formation of nanoparticles in the LIBS reactor were studied
The processes of hydrogen reduction of silicon and germanium chlorides under the conditions of radio-frequency (40.68 MHz) counteracted arc discharge stabilized between two rod electrodes were investigated. The main gas-phase and solid products of plasma-chemical transformations were determined.
Thermodynamic analysis of SiCl4 + H2 and GeCl4 + H2 systems was carried out. It is shown that under the implemented experimental conditions, equilibrium components of the products are established. The detected spectra of chemical activity were studied, which gave reason to assume that the molecular mechanism of the hydrogen reduction process is the main one. The impurity composition of gas-phase and solid reaction products was investigated. The possibility of single-stage production of high-purity Si and Ge mainly in the form of compact ingots, as well as high-purity chlorosilanes and trichlorogermane, was shown.
Ergot alkaloids are a group of toxic compounds, formed by fungi on infested grasses. In 2022, the European Commission set into effect maximum levels for the sum of the twelve major ergot alkaloids in multiple foods. To facilitate the laborious and costly individual quantification of the twelve major ergot alkaloids by HPLC–MS/MS or -FLD, we recently reported a sum parameter method (SPM) for ergot alkaloid quantification. Here, derivatization to lysergic acid hydrazide—a derivative of the mutual ergoline backbone in all ergot alkaloids—allowed simplified determination of all ergot alkaloids in flour via HPLC-FLD. For the measurement of more complex matrices like processed foods, we now developed a MS/MS-based SPM. Two internal standards (IS), isotopically labelled at different positions of the molecule, were synthesized and employed in the MS/MS-measurements. Method performance using either the 13CD3-labelled or the 15N2-labelled IS was evaluated on naturally contaminated rye and wheat flour samples as well as on processed food matrices. Employing the 13CD3-labelled IS leads to lower variances and better consistency with the reference data (obtained by the FLD-based SPM) in flour samples compared to the 15N2-labelled IS. The novel method significantly improves the measurement of ergot alkaloids in complex food matrices, due to their increased selectivity and thus lower interferences. Furthermore, the application of isotope labelled IS obviates the need for time-consuming steps like the determination of recovery rate based, matrix specific correction factors as described in the MS/MS-based European standard method for ergot alkaloid quantification (EN 17425).
Research into new sources for EUV lithography is driving advancements in experimental methods tailored for this short wavelength range. This progress enables the exploration of spectroscopic techniques aimed at monitoring electronic transitions within this energy spectrum. Laser-induced breakdown spectroscopy (LIBS) serves as a rapid tool for elemental analysis, primarily established in the UV-vis range. However, LIBS encounters challenges such as limited repeatability precision and elevated background noise resulting from continuum radiation.
In parallel, laser-induced extreme UV spectroscopy (LIXS) delves into the initial stages of plasma evolution, characterized by the emergence of soft X-ray and extreme UV radiation. The method benefits from a fast timeframe and constrained plasma confinement, leading to better precision. Nevertheless, LIXS encounters convoluted spectra arising from unresolved transition arrays (UTA), particularly pronounced for heavier elements. This complexity renders conventional univariate data analysis impractical, demanding the adoption of a multivariate data analysis approach.
Multiple cathode samples, each coated with varying stoichiometries of lithium nickel manganese cobalt oxide (NMC), were prepared and used for calibration purposes. Through the application of Partial Least Squares (PLS) regression, a robust correlation with an R2 value exceeding 0.97 was achieved. The LIXS technique underwent a comparative evaluation against UV-vis LIBS. Furthermore, a comparison between univariate and multivariate analysis approaches was conducted, incorporating validation through y-randomization to mitigate overfitting risks.
The viability of this approach was confirmed through the testing of an NMC reference material. The results showed metrological compatibility with reference values, underscoring the potential capability of the proposed methodology.
Gold-based nanoparticles below 2 nm in size are promising as luminescent probes for in vivo bioimaging, owing to their brightness and rapid renal clearance. However, their use as contrast agents in the near-infrared II (NIR-II, 1000–1700 nm) range remains challenging due to their low photoluminescence (PL) quantum yield. To address this, PL enhancement can be achieved by either rigidifying the ligand-shell structure or increasing the size of the ligand shell. In this study, we synthesized ultra-small gold nanoparticles stabilized by co-ligands, namely monothiol and short dithiol molecules. By precisely controlling the amount of reducing agent used during particle preparation, we successfully modulated the physicochemical properties of the co-ligand shell, including its size, composition, and structure. Consequently, we achieved a remarkable 60-fold increase in the absorption cross-section at 990 nm while maintaining the small size of the 1.5-nm metal core. The analytical and optical characterization of our thiol-capped gold nanoparticles indicates that the ligand shell size is governed by the quantity of the reducing agent, which, in turn, impacts the balance between radiative and non-radiative processes, thereby influencing the PL quantum yield.
Tailor-made nanoparticles are of increasing interest in e.g. catalysis, as sensor materials, analytical assays, or can have superior photophysical properties. A major issue concerning the preparation of high-quality and functional nanoparticles is a good control of particle size, shape, polydispersity, and composition.
Small Angle X-ray Scattering (SAXS) is a non-destructive method for the analysis of nanostructures in a wide variety of materials. This method allows determining averaged structural parameters on a length scale from just above atomic sizes up to several 100 nanometers such as sizes, size distributions, volume fractions, and inner surface sizes. Moreover, anomalous Small Angle X-ray Scattering (ASAXS) exploits the anomalous dispersion of the scattering amplitudes near the X-ray absorption edges of the elements contained in the sample. These element sensitive contrast variations can be used to analyse average composition fluctuations on the nm scale. Two kinds of nanoparticles are chosen here to elaborate the advantages of ASAXS in the analysis of complex materials.
A facile and efficient methodology is developed for the thermal synthesis of size-tunable, stable, and uniform bimetallic NiCu core–shell nanoparticles (NPs) for various application in catalysis. Their diameter can be tuned in a range from 6 nm to 30 nm and the Ni:Cu ratio is adjustable in a wide range from 1:1 to 30:1. The NPs are structurally characterized by a method combination of transmission electron microscopy, anomalous small-angle X-ray scattering (ASAXS), X-ray absorption fine structure, and X-ray photoelectron spectroscopy. Here, we focus on the ASAXS method and its ability to analyses nanostructure parts and their compositions at once. As a result, a NiCu alloyed core surrounded by a Ni enriched shell and an outer NiO shell was found.
Semiconductor nanocrystals (quantum dots, QDs) are well known for their superior photophysical properties and enabled advancements in several key technologies of the 21st century and numerous technological applications like in photovoltaics, LED displays, photocatalysis, and biosensing. To achieve high photoluminescence quantum yields (PLQY) and enhanced photostability the QD core needs to be passivated by a second semiconductor, which possess a larger band gap to confine the charges within the QD core. An important parameter is thereby the lattice mismatch between the core and shell. To avoid strong lattice strain, which would alter the photophysical properties, an intermediary shell can be used as a lattice adapter between the core and the outer shell leading to core/shell/shell systems. These systems have shown to possess high PLQYs combined with a strong long-term stability and can be found in modern QLED displays. ASAXS was used here to better understand the core/shell/shell structure of InP/ZnSe/ZnS QDs to enable a correlation between their structural and photophysical properties.
Laser breakdown spectroscopy (LIBS) is a common tool for applications in various fields of science and technology. Originally an atomic analysis technique, LIBS was later extended to molecular analysis due to the transient nature of the laser-induced plasma, which develops from a hot dissociation stage on a nanosecond to several microsecond scale to a relatively cold recombination stage on a scale of 10 to 100 microseconds after breakdown. Molecules formed during the recombination stage or incompletely dissociated after ablation can be efficiently detected, allowing the analysis of "difficult" elements or even molecular isotopes. However, with a small amount of ablated material and a short lifetime of the luminous plasma, analytical signals, especially molecular ones, can be very weak.
Several methods have been proposed for reheating the plasma and increasing its lifetime, for example, a two-pulse LIBS or a LIBS combined with microwave radiation or with an electric spark discharge. Here we propose another one, LIBS combined with a capacitively coupled RF discharge at 13.6 MHz. The advantages of this combination are an increase in the lifetime of atomic and molecular emission and operation in a low-pressure atmosphere, which significantly reduces pressure line broadening and allows high-resolution spectroscopy. Another major advantage is operating in a chemically controlled atmosphere that can predictably drive desired chemical reactions. In this presentation, we will show the first results obtained with RF-LIBS combination. These will include separate and joint characterization of LIBS and RF plasmas and evaluation of its potential for elemental and molecular analysis and for plasma enhanced chemical vapor deposition.
Many applications of LIBS require the measurement of plasma temperature and electron density, which in turn requires knowledge of the integrated line intensity and the shape of the spectral lines. While the integral intensity is preserved as light passes through the spectrometer, the shape emitted by an individual atom or ion is greatly distorted. This is due, firstly, to the transfer of light through the plasma (self-absorption), secondly, to the influence of the instrumental function of the spectrometer, and, thirdly, to the aberrations of the optical system. In addition, processing of spectral information, such as background removal, noise reduction, deconvolution, and line fitting, introduces additional errors in the reconstructed linewidth and line integral, which leads to erroneous temperature and electron density values.
This communication will be devoted to the general shortcomings of spectral data processing and the resulting inaccuracies in determining the plasma parameters. The analysis is based on the use of synthetic spectra generated by plasma with known temperature and particle density. The estimation of errors caused by inadequate processing of the spectral data is made by comparing the initial and determined plasma parameters. As a result, an improved data processing method will be proposed that takes into account the spectrum distortion by the instrumental function and integration on the pixel detector. The former is accounted for by convolution (instead of deconvolution) of the estimated line profile using a predetermined slit function, and the latter is achieved by piecewise integration of the line profile by the pixel detector, taking into account the pixel size and uniform or non-uniform pixel separation. Recommendations will be made for which analytic function best approximates the observed spectral lines and examples will be given for the application of this routine to calibration-free LIBS using both synthetic and experimental data.
In the LIBS literature, almost every second article reports the determination of the plasma temperature using the Boltzmann plot method or the determination of the electron density using the Stark line broadening relation. The first requires the measurement of the integrated intensities of the spectral lines, and the second requires the measurement of the linewidth, under the same assumption of optical thinness. It is taken for granted that this can be easily done either by working with the raw spectra or by fitting an appropriate function to the observed spectral lines. As a rule, reported data are not verified either by an alternative method (e.g., Thomson scattering) or by computer simulations using synthetic spectra.
However, the question of how to extract the necessary information from the raw spectral data is not as simple as it might seem. The quality of such an extraction will depend critically on the type of spectral instrument used, its resolution, and the noise superimposed on the data. The problem is that we do not see the spectrum emitted by the plasma, but the spectrum distorted by the measurement; an exaggerated example of such a distortion is shown in Fig. 1. The elimination of this distortion belongs to the class of inverse problems, the so-called ill-posed problems, whose successful solution crucially depends on the quality of the information available. When it comes to spectroscopy, quality of information primarily means high spectral resolution and low noise. Not all spectrometers used in LIBS can provide the quality needed to solve the inverse problem; this casts doubt on many published plasma measurements.
The current presentation will be devoted to general shortcomings in the processing of spectral data and inaccuracies in the determination of plasma parameters resulting from these shortcomings. The analysis is based on the use of synthetic spectra produced by plasma with known characteristics, i.e., temperature, species densities, and electron density. The estimation of errors caused by inadequate processing of spectral data is made by comparing the initial and reconstructed plasma parameters. Recipes will be given for which the analytic function best approximates the observed spectral lines, and how data processing errors affect accuracy of calibration-free LIBS will be discussed. These issues were only partially covered in previously published works, for example [1, 2, 3].
The aim of the project is to develop an adequate model of laser induced plasma for conditions expected in space missions, i.e., vacuum, or low-pressure CO2 atmosphere. Numerical modeling will help to find optimal experimental parameters for the laser ablation under artificial lunar or Martian environments and obtain both qualitative, in terms of a composition, and quantitative, in terms of an elemental abundance, information about interrogated samples based on spectral data generated by the model. The best operational conditions will be found at a low cost without conducting tedious and time-consuming optimization experiments. The modeling approaches will be supported by machine learning to accelerate the optimization.
The application of multivariate data analysis is essential in extracting the full potential of laser-induced XUV spectroscopy (LIXS) for high-precision elemental mapping. LIXS offers significant advantages over traditional laser-induced breakdown spectroscopy in UV-vis (LIBS), including higher precision and a wider dynamic range,[1,2] while making it possible to determine light elements like lithium and fluorine. However, it is challenged by the presence of unresolved transition arrays (UTAs) for heavier elements. These UTAs add considerable complexity to the spectral data, often concealing crucial information. In this study, we employ well-established multivariate data analysis techniques and intensive data preprocessing to unravel this contained information.
The refined analysis reveals a high level of detail, enabling the precise identification of inhomogeneities within material samples. Our approach has particular relevance for studying aging processes in lithium-ion batteries (LIBs), specifically in relation to varying cathode materials and fluorine-containing polymer binder content. By combining elemental distribution with structural information, this improved method can offer a more comprehensive understanding of sample inhomogeneities and aging processes in LIBs, contributing to the development of more reliable and sustainable battery technologies.
Laser-induced XUV spectroscopy (LIXS) is an emerging technique for elemental mapping. In comparison to conventional laser-induced breakdown spectroscopy in UV-vis (LIBS), it has a higher precision and wider dynamic range, and it is well suited for the quantification light elements like lithium and fluorine. Further it can spot oxidation states. The XUV spectra are produced at a very early stage of the plasma formation. Therefore, effects from plasma evolution on the reproducibility can be neglected. It has been shown, that high-precision elemental quantification in precursor materials for lithium-ion batteries (LIBs) can be performed using LIXS. Based on these results, LIXS mapping was used to investigate aging processes in LIBs. Different cathode materials with varying compositions of fluorine containing polymer binders were compared at different stages of aging. Due to effects comparable to X-ray photoelectron spectroscopy but in reverse, monitoring of changes in the oxidation state is envisioned, which makes information about the chemical environment of the observed elements accessible. The combination of elemental distribution and structural information leads to a better understanding of aging processes in LIBs, and the development of more sustainable and safe batteries.
Improved Data Processing for Accurate Plasma Diagnostics with Implications for Calibration-Free LIBS
(2023)
Many LIBS papers report the determination of plasma temperature using the Boltzmann plot method or the determination of electron density using the Stark line broadening relation. This requires measuring the integrated intensities of the spectral lines and the linewidth under the assumption of optical thinness. It is taken for granted that this can be easily done either by working with the raw spectra or by fitting the appropriate function to the observed spectral lines. However, extracting the necessary information from raw spectral data is not as easy as it might seem. The quality of such extraction will depend to a decisive extent on the type of spectral instrument used. The spectrum emitted by the plasma is distorted by the device; an example is shown in Fig. 1. The elimination of this distortion belongs to the class of inverse problems, the successful solution of which fundamentally depends on the quality of the available information. When it comes to spectroscopy, the quality of information primarily means high spectral resolution and low noise. Not all spectrometers used in LIBS can provide the quality needed to solve the inverse problem; this casts doubt on many published plasma measurements. This communication will be devoted to the general shortcomings of spectral data processing and the inaccuracies in determining the plasma parameters resulting from these shortcomings. The analysis is based on the use of synthetic spectra generated by plasma with known temperature, particle density and electron density. The estimation of errors caused by inadequate processing of spectral data is made by comparing the initial and measured plasma parameters from the spectra. Recommendations will be made for which analytic function best approximates the observed spectral lines, and how data processing errors affect the accuracy of calibration-free LIBS will be discussed. These issues were only partially covered in previously published works, for example [1, 2].
Introduction
Lithium-ion batteries (LIBs) are one key technology to overcome the climate crisis and energy transition challenges. Demands of electric vehicles on higher capacity and power drives research on innovative cathode and anode materials. These high energy-density LIBs are operated at higher voltages, leading to increased electrolyte decay and the current collectors' degradation. Even though this fundamental corrosion process significantly affects battery performance, insufficient research is being done on the aluminum current collector. Fast and convenient analytical methods are needed for monitoring the aging processes in LIBs.
Methods
In this work glow-discharge optical emission spectrometry (GD-OES) was used for depth profile analysis of aged cathode material. The measurements were performed in pulsed radio frequency mode. Under soft and controlled plasma conditions, high-resolution local determination (in depth) of the elemental composition is possible. Scanning electron microscopy (SEM) combined with a focused ion beam (FIB) cutting and energy dispersive X-ray spectroscopy (EDX) was used to confirm GD-OES results and obtain additional information on elemental distribution.
Results
The aging of coin cells manufactured with different cathode materials (LCO, LMO, NMC111, NMC424, NMC532, NMC622, and NMC811) was studied. GD-OES depth profiling of new and aged cathode materials was performed. Quantitative analysis was possible through calibration with synthetic standards and correction by sputter rate. Different amounts of aluminum deposit on the cathode surface were found for different materials. The deposit has its origin in the corrosion of the aluminum current collector. The results are compatible with results from FIB-EDX. However, GD-OES is a faster and less laborious analytical method. Therefore, it will accelerate research on corrosion processes in high energy-density batteries.
Innovative aspects
- Quantitative depth profiling of cathode material
-Monitoring of corrosion processes in high energy-density lithium-ion batteries
- Systematic investigation of the influence of different cathode materials
Per- and polyfluoroalkyl substances (PFAS) are a large group of organofluorine surfactants used in the formulations of thousands of consumer goods. The continuous use of PFAS in household products and the discharge of PFAS from industrial plants into the sewer system have been resulted in contaminated effluents and sewage sludge from wastewater treatment plants (WWTPs) which became an important pathway for PFAS into the environment. Because sewage sludge is often used as fertilizer its application on agricultural soils has been observed as significant input path for PFAS into our food chain. To produce high-quality phosphorus fertilizers for a circular economy from sewage sludge, PFAS and other pollutants (e.g. pesticides and pharmaceuticals) must be separated from sewage sludge. Normally, PFAS are analyzed using PFAS protocols typically with time-consuming extraction steps and LC-MS/MS target quantification. However, for screening of PFAS contaminations in wastewater-based fertilizers also the DGT technique can be used for the PFAS extraction. Afterwards, combustion ion chromatography (CIC) can be applied to analyze the “total” amount of PFAS on the DGT binding layer. The DGT method was less sensitive and only comparable to the extractable organic fluorine (EOF) method values of the fertilizers in samples with >150 µg/kg, because of different diffusion properties for various PFAS, but also kinetic exchange limitations. However, the DGT approach has the advantage that almost no sample preparation is necessary. Moreover, the PFAS adsorption on the DGT binding layer was investigated via surface sensitive spectroscopical methods, such as Fourier-transform infrared (FT-IR) and fluorine K-edge X-ray absorption near-edge structure (XANES) spectroscopy.
Data file (RData) containing measurement data recorded during the production process of the Certified Reference Material BAM-A001 containing Polycyclic Aromatic Hydrocarbons (PAH) in olive oil. The data can be most conveniently openend using the Shiny-App eCerto which is accessible at https://www.bam.de/eCerto.
With the continuous release of anthropogenic pollutants into the environment, substantial risks for the human health arise. Concerning are especially persistent substances (e.g., PFAS) as they accumulate in food chains which inevitably result in the transgression of negative impact threshold levels. Environmental Analytical Chemsitry interfaces all disciplines of Risk Assessment. Therefore it is the important tool to identify, monitor, and remediate environmental pollutants. Based on the example of PFAS, a workflow to tackle environmental pollutants in a retro- and pro-spective way is shown. Within the project, the worldwide situation of environmental pollutants will be illustrated for the example of PFAS. As the major discipline to confront the problem, analytical chemistry will be shown as a key tool for contesting PFAS and creating safe-by-design materials in the future.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
The combination of non-target analysis (NTA) based on HPLC-ESI-MS with elemental fluorine speciation analysis based on HPLC-PARCI-MS for the identification and quantification of (unknown) organofluorines in environmental samples is associated with several advantages e.g., reduced non-target data treatment workflow and quantification.
PFASs compromise persistent, bioaccumulative, and toxic properties and are hence, environmental contaminants of emerging concern. Thus, procedures for identifying potential sources of the entrance of these compounds into the environment, identification of new organofluorine species, and closing mass balances need urgent development. The intrinsic fluorine tag appears in a sizable fraction of these and other xenobiotics, making elemental speciation desirable for quantitative NTA in these areas. Current non-target approaches based on ESI-HRMS suffer from a lack of data mining algorithms for identification of PFASs with low fluorine mass percentages. Furthermore, low ionization efficiencies of the compounds hamper detection limits.
Hence, the proposed combination of simultaneous HPLC-ESI-MS and HPLC-PARCI-MS via split-stream coupling is a promising approach for environmental PFAS monitoring. Furthermore, it could serve as an important analytical procedure to set up limiting values in compliance with the desired PFAS ban of the European Union.
Compact NMR Spectroscopy in the field: A Versatile PAT Tool for Production of Specialty Chemicals
(2023)
Companies of chemical industry find themselves more often in a rapidly changing environment, e.g., due to variability of raw material quality or energy costs and efficiency. Process optimization and new process concepts become more and more important. For example, flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds like exothermic reactions with high heat dissipation.
Highly automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as explosion safety, field communication, and robust evaluation of sensor data. Field studies in modular and conventional production plant setups show promising results gaining process knowledge for further optimization. NMR appeared as preeminent online analytical method and allow using a modular data analysis approach, which can even serve as reliable reference method for further calibration-dependent PAT applications (e.g., NIR or Raman spectroscopy).
Based on experiences from earlier field studies an improved NMR analyzer enclosure setup was developed and built, including the option of a secondary method (e.g., optical spectroscopy). Integrated control systems allow for a flexible implementation based on the available automation infrastructure at the chemical plant or pilot plant setup. In the future, fully integrated and intelligently interconnecting “smart” PAT systems and processes have the potential speed up the setup of production equipment for chemicals and pharmaceuticals and therefore help to reduce the time-to-market.
Per- and polyfluoroalkyl substances (PFAS) are chemicals which were developed to improve humanity’s quality of life. Due to their high chemical stability and resistance to degradation by heat or acids, PFAS were used in a variety of consumer products. The continuous use of PFAS in household products and the discharge of PFAS from industrial plants into the sewer system resulted in the contamination of effluents and sewage sludge from wastewater treatment plants (WWTPs) (Roesch et al. 2022). Since sewage sludge is often used as fertilizer, its application on agricultural soils has been observed as a significant entry path for PFAS into the environment, specifically in our food chain. In Germany the sewage sludge/biosolid application on agricultural land was banned with the amendment of the German Sewage Sludge Ordinance and by 2029 sewage sludge application will be totally prohibited. However, phosphorus (P) from sewage sludge should still be recycled in WWTPs of cities with a population larger than 50,000 residents. To produce high-quality P-fertilizers for a circular economy, PFAS and other pollutants (e.g. pesticides and pharmaceuticals) must be separated from sewage sludge. Due to the strong diversity of industrial PFAS usage it is not clear if a safe application of novel recycled P-fertilizers from WWTPs can be guaranteed. Therefore, we analyzed various sewage sludges and wastewater-based fertilizers. Sewage sludge (SL) samples from various WWTPs in Germany and Switzerland, six sewage sludge ashes (SSA) from Germany, six thermally treated SL and SSA samples with different additives (temperatures: 700-1050 °C), two pyrolyzed SL samples (temperature: 400 °C) and two struvite samples from Germany and Canada were analyzed. The goal was to quantify PFAS in sewage sludges and wastewater-based P-fertilizers with the sum parameter extractable organic fluorine (EOF) by combustion ion chromatography (CIC). The results were compared with data from classical LC-MS/MS target analysis as well as selected samples by HR-MS suspect screening. The EOF values of the SLs mainly range between 154 and 538 µg/kg except for one SL which showed an elevated EOF value of 7209 µg/kg due to high organofluorine contamination. For the SSA samples the EOF values were lower and values between LOQ (approx. 60 µg/kg) and 121 µg/kg could be detected. For the pyrolyzed SLs no EOF values above the LOQ were detected. Moreover, the two wastewater-based struvite fertilizers contain 96 and 112 µg/kg EOF, respectively. In contrast to the EOF values, the sum of PFAS target values were relatively low for all SLs. Additional applied PFAS HR-MS suspect screening aimed to tentatively identify PFAS that could contribute to the hitherto unknown part of the EOF value. The majority of the detected fluorinated compounds are legacy PFAS such as short- and long-chain perfluorocarboxylic acids (PFCA), perfluorosulfonic acids (PFSA), polyfluoroalkyl phosphate esters (PAPs) and perfluorophosphonic acids (PFPA). Moreover, fluorinated pesticides, pharmaceutical as well as aromatic compounds were also identified, which are all included in the EOF parameter. Our research revealed that the current PFAS limit of 100 µg/kg for the sum of PFOS + PFOA in the German Fertilizer Ordinance is no longer up to date. Since the number of known PFAS already exceeds 10,000, the ordinance limit should be updated accordingly. Recent regulations and restrictions on using long-chain PFAS (≥C8) have resulted in a significant shift in the industry towards (ultra-)short-chain alternatives, and other, partly unknown, emerging PFAS. Ultimately, also fluorinated pesticides and pharmaceuticals, which end up as ultrashort PFAS in the WWTPs, have to be considered as possible pollutants in fertilizers from wastewater, too.