Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (1171)
- Vortrag (1069)
- Posterpräsentation (442)
- Beitrag zu einem Tagungsband (174)
- Forschungsdatensatz (55)
- Sonstiges (43)
- Buchkapitel (24)
- Forschungsbericht (23)
- Dissertation (15)
- Beitrag zu einem Sammelband (13)
- Handbuch (5)
- Video (5)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (3)
- Sammelband (Herausgeberschaft für den kompletten Band) (2)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
- Newsletter (1)
Sprache
- Englisch (3046) (entfernen)
Schlagworte
- Nanoparticles (114)
- Fluorescence (112)
- Concrete (89)
- LIBS (81)
- Mechanochemistry (72)
- Quantum yield (71)
- Ultrasound (71)
- SAXS (69)
- Non-destructive testing (68)
- XPS (61)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1085)
- 6 Materialchemie (973)
- 8 Zerstörungsfreie Prüfung (774)
- 6.1 Oberflächen- und Dünnschichtanalyse (348)
- 6.3 Strukturanalytik (322)
- 1.1 Anorganische Spurenanalytik (277)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (232)
- 8.0 Abteilungsleitung und andere (224)
- 1.2 Biophotonik (210)
- 4 Material und Umwelt (186)
Paper des Monats
- ja (26)
The contamination of drinking water with pharmaceuticals represents a severe health risk. In order to monitor the drinking water quality continuously and enable quick countermeasures in case of contamination, novel sensors are required. Here, immunoanalytical methods based on the binding of the analyte to highly selective antibodies can be helpful. In this work, magnetic bead-based immunoassays (MBBAs) have been developed for the detection of two relevant contaminants of drinking water: diclofenac (DCF) and amoxicillin (AMX). In case of the latter, not only the parent drug is of interest in the risk assessment but also its hydrolysis products (HPs). In a comprehensive study, the influence of external factors and intrinsic properties of the water on the rate of hydrolysis was investigated. As the hydrolysis of AMX further impacts the recognition by the antibody, a strategy to analyze samples with unknown hydrolysis degree of AMX was established employing the enzyme β-lactamase in sample preparation. For both analytes, the MBBAs enable the fast quantification with results obtained in less than one hour which represents a major improvement over conventional immunoassays like the enzyme-linked immunosorbent assay (ELISA). Compared to the respective ELISAs with the same antibodies, the MBBAs further exhibit improved analytical parameters such as a broader measurement range and lower limits of detection. Due to the magnetic properties of the beads that serve as a platform for the assays, they are suitable for the mobile and automated detection at the point-of-care. An integrated diagnostic system was designed in which electrochemical detection with chronoamperometry on a microfluidic chip allows for further miniaturization of the system to enable monitoring of the drinking water quality online in water supply pipes at waterworks.
The statistical tool eCerto was developed for the evaluation of measurement data to assign property values and associated uncertainties of reference materials. The analysis is based on collaborative studies of expert laboratories and was implemented using the R software environment. Emphasis was put on comparability of eCerto with SoftCRM, a statistical tool based on the certification strategy of the former Community Bureau of Reference. Additionally, special attention was directed towards easy usability from data collection through processing, archiving, and reporting. While the effects of outlier removal can be flexibly explored, eCerto always retains the original data set and any manipulation such as outlier removal is (graphically and tabularly) documented adequately in the report. As a major reference materials producer, the Bundesanstalt für Materialforschung und -prüfung (BAM) developed and will maintain a tool to meet the needs of modern data processing, documentation requirements, and emerging fields of RM activity. The main features of eCerto are discussed using previously certified reference materials.
The European Commission has identified Advanced Manufacturing and Advanced Materials as two of six Key Enabling Technologies (KETs). It is considered that Metrology is a key enabler for the advancement of these KETs. Consequently, EURAMET, the association of metrology institutes in Europe, has strengthened the role of Metrology for these KETs by enabling the creation of a European Metrology Network (EMN) for Advanced Manufacturing. The EMN is comprised of National Metrology Institutes (NMIs) and Designated Institutes (DIs) from across Europe and was formally established in October 2021. The aim of the EMN is to provide a high-level coordination of European metrology activities for the Advanced Manufacturing community.
The EMN itself is organized in three sections representing the major stages of the manufacturing chain: 1) Advanced Materials, 2) Smart Manufacturing Systems, and 3) Manufactured Components & Products. The EMN for Advanced Manufacturing is engaging with stakeholders in the field of Advanced Manufacturing (large companies & SMEs, industry organisations, existing networks, and academia), as well as the wider Metrology community, including Technical Committees, to provide input for the Strategic Research Agenda (SRA) on Metrology for Advanced Manufacturing.
This contribution will give an overview about the first version of the SRA prepared by the EMN for Advanced Manufacturing.
Human factors (HFs) are a frequently mentioned topic when talking about the reliability of non-destructive testing (NDT). However, probability of detection (POD), the commonly used measure of NDT reliability, only looks at the technical capability of an NDT system to detect a defect.
After several decades of research on the influence of HFs on NDT reliability, there is still no commonly accepted approach to rendering HFs visible in reliability assessment. This paper provides an overview of possible quantitative and qualitative methods for integrating HFs into the reliability assessment. It is concluded that reliability assessment is best carried out using both quantifiable and non-quantifiable approaches to HFs.
Concrete is the most important human-made material because it serves as the basis of our built environment. Since the properties of concretes are dominated by their key compound, cement, devising a way to determine the cement’s origin, known as provenancing, is of great importance for answering different provenance-related questions. These questions range from liability issues when damage occurs to concrete-made structures, to forensic investigations where cement particles are found at crime scenes. This thesis showcases the use of isotope techniques to answer these provenance-related questions. Conventional 87Sr/86Sr and 143Nd/144Nd isotope and elemental ratios consisting of Ca, Sr, K, Mn, Mg, and Ti are used as fingerprints for ordinary Portland cement (OPC) provenancing. The first part of this thesis describes research previously conducted in fingerprinting cementitious materials, providing an overview of provenance studies of cement and the main approaches commonly used. In several studies, the origin of clinker for certain locations was determined via different approaches. However, clinker is an intermediate product, which is available only at the production site and therefore, the practical relevance is rather limited. Furthermore, the use of Sr and Nd isotope systems, together with elemental fingerprints are presented as state of the art in the field. Therein, the principal approach for the overall study is sketched. For the second part of the study, a sample preparation technique for Sr isotopes in Portland cement was developed. The aim was to find the most appropriate sample preparation procedure for cement provenancing and selection was realised by comparing the 87Sr/86Sr isotope ratios of differently treated OPCs with those of the corresponding clinkers. Based on these findings, the third part of the study focused on the measurements of Sr and Nd isotope ratios, together with elemental ratios, to establish a reliable technique for OPC provenancing. The outcomes of this final stage are then used to establish a procedure for fingerprinting cements. This becomes possible with the use of Sr and Nd isotope ratios and geochemical profiles. To perform isotope ratio measurements and obtain reliable data, it was necessary to establish a quality control procedure. Thus, an interlaboratory comparison (ILC) was organised to characterise 87Sr/86Sr isotope ratios in geological and industrial reference materials by applying the conventional method for 87Sr/86Sr isotope ratios. As reference material, four cements (VDZ 100a, VDZ 200a, VDZ 300a, IAG OPC-1), one limestone (IAG/CGL ML-3) and one slate (IAG OU-6) were selected, thus covering a wide range of Sr isotope signatures.
Sr isotope ratio analysis
(2023)
Pb isotope ratio analysis
(2023)
Detector deadtime
(2023)
Isotope Ratio Analysis
(2023)
The through-life management of our constantly ageing infrastructure is a basic requirement in order to ensure their structural safety and serviceability. Each structure experiences deterioration processes with time leading to a decrease of structural safety and serviceability. The design of new structures considers the expected deterioration for a defined period, the design service life. However, a frequent survey of structural safety controlling structural condition should be mandatory and a maintenance plan should be an integral part of the design. In addition, many structures have exceeded their design service life already or are very close to it leading to an increasing demand for condition assessment. On the one hand, assumptions made during design are not valid any more due to change of the loads, e.g., increasing traffic loads in terms of number and weights. On the other hand, design codes evolved over time in such a way that existing structures do not comply with today’s standards. In all these cases, the through-life management is an important tool to maintain the accessibility of existing structures with known reliability.
In line with the new Model Code for Concrete Structures, which includes guidance for both – design of new structures and assessment of existing structures, the Task Group 3.3 focused on the compilation of a state-of-the-art guideline for the through-life management of existing concrete structures, including:
Data acquisition by testing and monitoring techniques;
Condition assessment for the evaluation of existing structures;
Performance prediction using advanced methods;
Decision-making procedures to perform a complete assessment of existing structure.
The overall objective of the through-life management is the assessment of the current condition and the estimation of the remaining service life under consideration of all boundary conditions.
Here, we elucidate nonclassical multistep crystallization pathways of transition metal phosphates from aqueous solutions. We followed precipitation processes of M-struvites, NH4MPO4·6H2O, and M-phosphate octahydrates, M3(PO4)2·8H2O, where M = Ni, Co, or NixCo1–x, by using in situ scattering and spectroscopy-based techniques, supported by elemental mass spectrometry analyses and advanced electron microscopy. Ni and Co phosphates crystallize via intermediate colloidal amorphous nanophases, which change their complex structures while agglomerating, condensing, and densifying throughout the extended reaction times. We reconstructed the three-dimensional morphology of these precursors by employing cryo-electron tomography (cryo-ET). We found that the complex interplay between metastable amorphous colloids and protocrystalline units determines the reaction pathways. Ultimately, the same crystalline structure, such as struvite, is formed. However, the multistep process stages vary in complexity and can last from a few minutes to several hours depending on the selected transition metal(s), their concentration, and the Ni/Co ratio.
Surface functionalized silica nanoparticles (SiO2-NP) gained great interest in the life and material sciences, as they can be used e.g. as drug carriers, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. They are highly stable, are easily produced and modified on a large scale at low cost and can be labeled or stained with a multitude of sensor dyes. These dye modified particle conjugates have several advantages as compared to conventional molecular probes like enhanced brightness, ease of designing ratiometric systems by combining analyte-sensitive and inert reference dyes, and increased photostability. Moreover, stained nanoparticles can enable the use of hydrophobic dyes in aqueous environments.
Here we present our work on multicolored sensors for the measurement of pH, oxygen and saccharides utilizing amorphous SiO2 NPs.
In recent years, chromium (III) complexes have received a lot of attention as novel near-infrared (NIR) emitters triggered by the report on the first molecular ruby Cr(ddpd)2(BF4)3 with a high photoluminescence quantum yield of 13.7% of its near infrared (NIR) emission band and a long luminescence lifetime of 1.122 ms at room temperature.[1] However, in an oxygen-containing environment, the photoluminescence quantum yields and luminescence lifetimes of these chromium(III) complexes show only very small values. This hampers their application as NIR luminescence labels. This application, that cannot be tackled by conventional deoxygenating approaches, requires suitable strategies to protect the luminescence of the chromium(III) complexes from oxygen quenching. An elegant approach to reduce the undesired luminescence quenching by triplet oxygen explored by us presents the incorporation of these chromium(III) complexes into different types of amorphous, non-porous silica nanoparticles, that can be simply surface functionalized, e.g., with targeting ligands and/or other sensor molecules. In this work, as first proof-of-concept experiments, a set of chromium (III) complexes constituting of different ligands and counter anions, were embedded into the core of silica nanoparticles. Subsequently, the optical properties of the resulting luminescent silica nanoparticles were spectroscopically assessed by steady state and time-resolved luminescence spectroscopy. First results of time-resolved luminescence measurements confirm our design concept of nanoscale NIR emissive Cr(III) complex-based reporters
Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage which improve the quality of life and European prosperity. NP function, performance, interaction with biological species, and environmental fate are largely determined by their surface functionalities. Standardized repeatable surface characterization methods are therefore vital for quality control of NPs, and to meet increasing concerns regarding their safety. Therefore, industry, regulatory agencies, and policymakers need validated traceable measurement methods and reference materials. This calls for fit-for-purpose, validated, and standardized methods, and reference data and materials on the surface chemistry of engineered NPs. Here, we present a concept for the development of such standardized measurement protocols utilizing method cross-validation and interlaboratory comparisons (ILCs) with emphasis on both advanced measurement methods such as quantitative Nuclear Magnetic Resonance (qNMR), X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS) and cost-efficient, non-surface specific methods like optical assays and electrochemical titration methods.
Engineered and tailored nanomaterials (NM) are of great interest in the life and material sciences, as they can be used, e.g., as drug carriers, barcodes, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. Their performance and safety depend not only on their particle size, size distribution, and morphology, but also on their surface chemistry, i.e., the total number of surface functional groups (FG) and the number of FG accessible for subsequent functionalization with ligands or biomolecules, which in turn determines surface charge, colloidal stability, biocompatibility, and toxicity. It also underlines the importance of validated analytical methods that provide accurate information on these application-relevant physicochemical properties with a known uncertainty. In the case of FG quantification, this calls for robust, fast, inexpensive, and reliable methods which allow for the characterization of a broad variety of NM differing in size, chemical composition, and optical properties.
Methods
Aiming at the development of simple, versatile, and multimodal tools for the quantification of bioanalytically relevant FG such as amine, carboxy, thiol, and aldehyde functionalities, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance (NMR), mass spectrometry (MS), and thermal analysis methods.
Results
Here, we will present examples for different types of NMs and FGs including results from a currently running interlaboratory comparison (ILC) with the National Research Council of Canada (NRC) to pave the road for method standardization.
Innovative aspects
• Surface analysis
• Performance and safety of nanomaterials
• Standardization
Engineered nanomaterials (NM) with their large surface-to-volume ratios and their for some materials observed size-dependent functional properties are of increasing relevance for current and future developments in various fields such as medical and pharmaceutical industry, computing and electronics or food and consumer products. The performance and safety of NM are determined by the sum of their intrinsic physicochemical properties. Especially, the particle surface chemistry, which is largely controlled by the chemical nature and density of functional groups (FG) and ligands, is an important key driver for NM performance, stability, and processibility as well as the interaction of NM with the environment. Thus, methods for FG quantification can foster the sustainable development of functional and safe(r) NM.
Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made polymeric and silica particles of varying FG, used as optical pH sensors. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
In recent years, the use of functionalized micro- and nanomaterials has increased rapidly for a wide range of applications in the life and material sciences, due to their unique properties in combination with their high surface-to-volume ratio and stability. For instance, functionalized micro- and nanomaterials, that are labeled or stained with a multitude of sensor dyes can be used for monitoring, and quantification of neutral and ionic analytes. These materials have several advantages as compared to conventional molecular probes like enhanced brightness, ease of designing ratiometric systems by combining analyte-sensitive and inert reference dyes, and increased photostability. Moreover, stained nanoparticles can enable the use of hydrophobic dyes in aqueous environments.
Versatile templates and carriers for the fabrication of nanosensors by staining and/or labeling with different fluorophores and sensor molecules are biocompatible silica and polymeric particles, because they can be synthesized in large scales at low costs with different surface chemistries.
Here we present our work on multicolored sensors for the measurement of pH, oxygen and saccharides utilizing commercially available or in-house synthesized silica and polymeric particles.
Nowadays amorphous silica nanoparticles (SiO2-NP) are one of the most abundant engineered nanomaterials, that are highly stable and can be easily produced on a large scale at low cost. Surface functionalized SiO2-NP are of great interest in the life and material sciences, as they can be used e.g. as
drug carriers, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. Their performance in such applications depends not only on particle size, size distribution, and morphology, but also on surface chemistry, i.e. the total number of surface functional groups (FG)
and the number of FG accessible for subsequent functionalization with ligands or biomolecules, which in turn determines surface charge, colloidal stability, biocompatibility, and toxicity. Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made silica particles of varying FG, showing not only an influence of the synthesis methods on the number of FG but also on the performance. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
In the focus of division Biophotonics are the design, preparation, analytical and spectroscopic characterization, and application of molecular and nanoscale
functional materials, particularly materials with a photoluminescence in the visible, near infrared (NIR) and short-wave infrared (SWIR). This includes optical reporters for bioimaging and sensing, security and authentication barcodes, and materials for solid state lighting, energy conversion, and photovoltaics. For the identification of optimum particle structures quantitative spectroscopic studies are performed under application-relevant conditions, focusing on the key performance parameter photoluminescence quantum yield. In addition, simple, cost-efficient, and standardizable strategies for quantifying functional groups on the surface of nano- and microparticles are developed, here with a focus on optical assays and electrochemical titration methods, cross-validated by more advanced methods such as quantitative NMR. In addition, reference materials and reference products are developed for optical methods, particularly luminescence techniques, and for analytical methods utilized for the characterization of nanomaterials.
For fluorescence microscopy, there is an increasing need for suitable calibration tools and reference materials for microscope calibration, the determination of performance parameters, and the regular control and validation of instrument performance. This is addressed in the BmWk-financed project FluMikal (WIPANO program) by two research groups from academia and two companies, that is coordinated by BAM. Here we present different approaches to liquid and solid fluorescence standards for the determination of the wavelength-dependent spectral sensitivity of fluorescence microscopes and ideas concerning the choice of suitable fluorescence lifetime standard for increasingly utilized fluorescence lifetime imaging (FLIM).
The digitalization of quality control processes and the underlying data infrastructures for safety relevant components, such as hydrogen pressure vessels, plays a significant role in the transition towards Industry 4.0. In the current safety regulations for hydrogen pressure vessels, there is no established concept for structural health monitoring. The development of a reliable structural health monitoring methodology for monitoring the structural integrity of pressure vessels enables a fast-forward transition from personnel- and costintensive recurring inspections, a.k.a. periodic maintenance, to predictive maintenance. In the work presented; we investigated the application of ultrasonic guided wave propagation to monitor and assess the condition of Type IV composite overwrapped pressure vessel (COPV). A sensor network of fifteen piezo-electric wafers is placed on the carbon fibre reinforced composite cylinder. Five different artificial damage configurations are created by gluing two different weight blocks on three different locations. The database containing measured guided wave data sets is enriched by two different boundary conditions. We utilized an open-source software, openBIS labnotebook, to store and analyse experimental datasets. The guided wave ultrasonic signals were investigated and analysed by using commonly used ultrasonic features (e.g., amplitude, frequency, time of flight) as well as non-traditional time-series features (kurtosis, skewness, variance). The features were used to calculate damage index and the detection performance for the results has been evaluated. The results suggest that both traditional and non-traditional features assume significant importance in artificial damage detection. The future works will additionally involve the impacts of operational conditions, such as periodic pressure variations temperature loadings as well as material degradations.
The application of composite overwrapped pressure vessels (COPV) to store hydrogen and other compressed gases, especially when operating at high pressures, imposed the need for an innovative and reliable approach to ensure the safe operation of the system. Continuous structural health monitoring (SHM) based on ultrasonic guided waves (GWs) is a promising approach due to the ability of the wave to propagate for long distances and go around complex structures, moreover the high sensitivity to various failure modes such as delamination, matrix cracking and debonding. In this study, we scrutinize the behavior of (GWs) within the COPV using a network of PZT elements that are used for excitation and sensing. A laser doppler vibrometer (LDV) was also used to scan the surface of the vessel in various directions. L(0,1) and L(0,2) were observed in the captured signal. The L(0, 2) appeared to be a dominant mode in the COPV and was capable of propagating along the entire length and maintaining a good signal-to-noise ratio. The L(0,2) mode maintained the same phase velocity when it is captured at various excitation angles (0, 45, and 90 degrees). The reduced effect of the orthotropy of the materials on the propagating waves is an important result as it will reduce the complexity in data processing when performing damage identification.
In the event of moisture deterioration, rapid detection and localization is particularly important to prevent further deterioration and costs. For building floors, the layered structure poses a challenging obstacle for most moisture measurement methods. But especially here, layer-specific information on the depth of the water is crucial for efficient and effective repairs. Ground Penetrating Radar (GPR) shows the potential to generate such depth information. Therefore, the present work investigates the suitability of GPR in combination with machine learning methods for the automated classification of the typical deterioration cases (i) dry, (ii) wet insulation, and (iii) wet screed.
First, a literature review was conducted to identify the most common methods for detecting moisture in building materials using GPR. Here, it especially became clear that all publications only investigated individual time-, amplitude- or frequency features separately, without combining them. This was seen as a potential aspect for innovation, as the multivariate application of several signal features can help to overcome individual weaknesses and limitations.
Preliminary investigations carried out on drying screed samples confirmed the profitable use of multivariate evaluations. In addition to the general suitability and dependencies of various features, first limitations due to possible interference between the direct wave and the reflection wave could be identified. This is particularly evident with thin or dry materials, for which the two-way travel times of the reflected radar signals become shorter.
An extensive laboratory experiment was carried out, for which a modular test specimen was designed to enable the variation of the material type and thickness of screed and insulation, as well as the simulation of moisture deteriorations. The data collected revealed clear differences between dry and deteriored structures within measured B-scans. These deviations were to be detected with the newly introduced B-scan features, which evaluate the statistical deviation of A-scan features within a survey line. In this way, deteriorations to unknown floor structures are recognized, regardless of the material parameters present. In a subsequent training and cross-validation process of different classifiers, accuracies of over 88 \% of the 504 recorded measurements (252 different experimental setups) were achieved. For that, the combination of amplitude and frequency features, which covered all relevant reflections of the radar signals, was particularly beneficial. Furthermore, the data set showed only small differences between dry floors and deteriored screeds for the B-scan features, which could be attributed to a homogeneous distribution of the added water in the screeds. The successfully separation of these similar feature distributions raised the suspicion of overfitting, which was examined in more detail by means of a validation with on-site data.
For this purpose, investigations were carried out at five different locations in Germany, using the identical measurement method like in the laboratory. By extracting drilling cores, it was possible to determine the deterioration case for each measurement point and thus generate a corresponding reference. However, numerous data had to be sorted out before classification, since disturbances due to underfloor heating, screed reinforcements, steel beams or missing insulation prevented comparability with the laboratory experiments. Validation of the remaining data (72 B-scans) achieved only low accuracy with 53 \% correctly classified deterioration cases. Here, the previously suspected overfitting of the small decision boundary between dry setups and deteriored screeds within the laboratory proved to be a problem. The generally larger deviations within (also dry) on-site B-scans were thus frequently misclassified as screed deterioration. In addition, there were sometimes strongly varying layer thicknesses or changing cases of deterioration within a survey line, which caused additional errors due to the local limitation of the drilling core reference. Nevertheless, individual on-site examples also showed the promising potential of the applied signal features and the GPR method in general, which partly allowed a profound interpretation of the measurements. However, this interpretation still requires the experience of trained personnel and could not be automated using machine learning with the available database. Nevertheless, such experience and knowledge can be enriched by the findings of this work, which provide the basis for further research.
Future work should aim at building an open GPR data base of on-site moisture measurements on floors to provide a meaningful basis for applying machine learning. Here, referencing is a crucial point, whose limitations with respect to the moisture present and its distribution can easily reduce the potential of such efforts. The combination of several reference methods might help to overcome such limitations. Similarly, a focus on monitoring approaches can also help to reduce numerous unknown variables in moisture measurements and increase confidence in the detection of different deterioration cases.
These data sets serve as models for calculating the specific surface area (BET method) using gas sorption in accordance with ISO 9277.
The present measurements were carried out with nitrogen at 77 Kelvin and argon at 87 Kelvin.
It is recommended to use the following requirements for the molecular cross-sectional area:
Nitrogen: 0.1620 nm²
Argon: 0.1420 nm²
Titanium dioxides certified with nitrogen sorption and additionally measured with argon for research purposes were used as sample material.
The resulting data sets are intended to serve as comparative data for own measurements and show the differences in sorption behaviour and evaluations between nitrogen and argon.
These data are stored in the universal AIF format (adsorption information file), which allows flexible use of the data.
We employ in-house generated synthetic Al-Si matrix composite XCT data for training deep convolutional neural networks for XCT data conditioning and automatic segmentation. We propose an in-house multilevel deep conditioning framework capable of rectifying noise and blur in corrupted XCT data sequentially. Furthermore, for automatic segmentation, we utilize a special in-house network coupled with a novel iterative segmentation algorithm capable of generalized learning from synthetic data. We report a consistent SSIM efficiency of 92%, 99%, and 95% for the combined denoising/deblurring, standalone denoising, and standalone deblurring, respectively. The overall segmentation precision was over 85% according to the Dice coefficient. We used experimental XCT data from various scans of Al-Si matrix composites reinforced with ceramic particles and fibers.
It is shown that preconditioning of experimental X‐ray computed tomography (XCT) data is critical to achieve high‐precision segmentation scores. The challenging experimental XCT datasets and deep convolutional neural networks (DCNNs) are used that are trained with low‐resemblance synthetic XCT data. The material used is a 6‐phase Al–Si metal matrix composite‐reinforced with ceramic fibers and particles. To achieve generalization, in our past studies, specific data augmentation techniques were proposed for the synthetic XCT training data. In addition, two toolsets are devised: (1) special 3D DCNN architecture (3D Triple_UNet), slicing the experimental XCT data from multiple views (MultiView Forwarding), the i.S.Sy.Da.T.A. iterative segmentation algorithm, and (2) nonlocal means (NLM) conditioning (filtering) for the experimental XCT data. This results in good segmentation Dice scores across all phases compared to more standard approaches (i.e., standard UNet architecture, single view slicing, standard single training, and NLM conditioning). Herein, the NLM filter is replaced with the deep conditioning framework BAM SynthCOND introduced in a previous publication, which can be trained with synthetic XCT data. This leads to a significant segmentation precision increase for all phases. The proposed methods are potentially applicable to other materials and imaging techniques.
The applications of composite overwrapped pressure vessels (COPVs) in extreme conditions, such as storing hydrogen gases at very high pressure, impose new requirements related to the system's integrity and safety. The development of a structural health monitoring (SHM) system that allows for continuous monitoring of the COPVs provides rich information about the structural integrity of the component. Furthermore, the collected data can be used for different purposes such as increasing the periodic inspection intervals, providing a remaining lifetime prognosis, and also ensuring optimal operating conditions. Ultimately this information can be complementary to the development of the envisioned digital twin of the monitored COPVs. Guided waves (GWs) are preferred to be used in continuous SHM given their ability to travel in complex structures for long distances. However, obtained GW signals are complex and require advanced processing techniques. Machine learning (ML) is increasingly utilized as the main part of the processing pipeline to automatically detect anomalies in the system's integrity. Hence, in this study, we are scrutinizing the potential of using ML to provide continuous monitoring of COPVs based on ultrasonic GW data. Data is collected from a network of sensors consisting of fifteen Piezoelectric (PZT) wafers that were surface mounted on the COPV. Two ML algorithms are used in the automated evaluation procedure (i) a long short-term memory (LSTM) autoencoder for anomaly detection (defects/impact), and (ii) a convolutional neural network (CNN) model for feature extraction and classification of the artificial damage sizes and locations. Additional data augmentation steps are introduced such as modification and addition of random noise to original signals to enhance the model's robustness to uncertainties. Overall, it was shown that the ML algorithms used were able to detect and classify the simulated damage with high accuracy.
Lanthanide Nanocrystals as Authentication and Security Tags and Reporters for Optical Sensors
(2023)
Counterfeiting of goods has serious economic implications worldwide and can present a considerable threat to human health and national security, rendering product authentication more and more important. This led to an increasing interest in simple tags for anticounterfeiting and authentication applications for the integration into different materials and matrices that are robust enough to survive the respective production processes and can be read out in-situ with simple instrumentation.
Here we present a platform of chemically inert, multi-color luminescent lanthanide nanocrystals (LnNC) consisting of a NaYF4 matrix doped with Yb, Er, Tm, or Ho as promising candidates for such applications.
LnNC with characteristic multi-color emission patterns, composed of narrow bands of varying intensity in the ultraviolet, visible, near-infrared, and short-wave were synthesized via a thermal decomposition approach under inert conditions[1]. The tailor-made design of different emission pattern was achieved by tuning particle size, material composition, and particle surface chemistry in upscaleable syntheses.[2] Particle size and morphology were determined by dynamic light scattering and transmission electron microscopy and the optical properties were characterized by absorption and fluorescence spectroscopy as well as fluorescence lifetime measurements.
The particles were then incorporated into security inks and consumer products. In addition, microenvironment-specific changes in the emission properties of the LnNC tag were utilized to study and sense changes of physico-chemical parameters in different matrices.
Counterfeiting of goods has serious economic implications worldwide and can be a threat to human health and safety. Upconversion nanoparticles (UCNPs)are ideal candidates for optical encoding of various materials. Particles with tailor-made emission patterns can be used as anti-counterfeiting markers and luminophores in security inks and to track material flows. Microenvironment-specific changes in the emission properties of the UCNP tags can be used to study, signal, and sense changes of physico-chemical parameters in different environments, e.g., building
materials.
Demonstrating competency and equivalence for the measurement capacity of contaminants and nutrients in primary foodstuffs is a priority of the OAWG 10-year strategy for Track A core comparisons. Such measurements have posed significant challenges for reference material producers and calibration service providers. This key comparison (KC), under the topic of “non- polar analyte in high carbohydrate food matrix: trans-Zearalenone (trans-ZEN) in maize powder” , was a sector of the model system selected to align with this class within the OAWG strategy. Evidence of successful participation in formal, relevant international comparisons is needed to demonstrate the Calibration and Measurement Capabilities (CMCs) of national metrology institutes (NMIs) and designated institutes (DIs).
17 NMIs and DIs participated in the Track A KC CCQM- 168 “non-polar analyte in high carbohydrate food matrix: trans-ZEN in maize powder” . Participants were requested to evaluate the mass fraction (μg/kg) of trans-ZEN in maize powder material. Methods like liquid-liquid extraction and SPE were applied in the pre-treatment, and HPLC-MS/MS and HPLC-FLD were used for detection by the participants. The mass fractions for trans-ZEN were in the range of (91.8 to 169) μg/kg with standard uncertainties of (1.5 to 24.7) μg/kg, and corresponding relative standard uncertainties from 1.5% to 14.6%. Two labs, INTI and BAM were excluded from the KCRV evaluation. INTI result was identified as an outlier and confirmed their method had insufficient specificity. For BAM the calibration approach they used does not meet the CIPM traceability requirements. The other 15 labs included in the calculation of the consensus KCRV all agreed within their standard uncertainties. Hierarchical Bayes was used as estimators in calculating KCRV and standard uncertainty.
Successful participation in CCQM-K168 demonstrates the measurement capabilities in determining mass fraction of organic compounds, with molecular mass of 100 g/mol to 500 g/mol, having low polarity pKow < -2, in mass fraction range from 1 μg/kg to 1000 μg/kg in a high carbohydrate food matrix.
Trace element (TE) analysis of pyrite via LA-ICP-MS can be used to reconstruct the conditions of pyrite formation in complex mineral systems. The Carpentaria province in northern Australia is host to some of the world’s highest value Zn-Pb (+Ag, Cu) deposits. The genesis of many of these deposits is controversial, with competing models of single-vs. multi-stage ore formation. In this study, LA-ICP-MS data of paragenetically constrained pyrite from the George Fisher Zn-Pb-Ag deposit has been analysed to investigate the chemistry of different stages of ore formation. Pyrite from correlative unmineralized host rocks has also been analysed to investigate evidence of distal hydrothermal anomalism. All LA-ICP-MS data have been statistically evaluated (principal component analysis) and interpreted together with whole rock lithogeochemical data of the same samples. Pre-ore diagenetic pyrite is compositionally similar to other Proterozoic diagenetic pyrite, with some evidence of minor hydrothermal anomalism that with further analysis could help define distal alteration. Pyrite from the different ore stages are compositionally distinct, consistent with a multi-stage system. Ore stage 1 pyrite exceeds background contents of Co, Cu, Zn, As, Ag, Sb, Tl, and Pb and has elevated Co/Ni ratios, whereas only Ni and Co are above background abundances in ore stage 2 and 3 pyrite, of which only ore stage 3 pyrite has high Co/Ni ratios. Ore stage 1 pyrite has a similar composition to hydrothermal pyrite in the undeformed northern Carpentaria CD-type deposits and was likely syn-diagenesis. Ore stage 2 was syn-deformation, and resulted in replacement and recrystallization of pre-existing pyrite, and the expulsion of incompatible TEs. Ore stage 3 formed via a later Cu-Zn-Pb mineralizing event that resulted in a new geochemically distinct generation of Co-rich pyrite. Overall, this study demonstrates the value of paragenetically-constrained pyrite TE data for refining genetic models in complex sediment hosted mineral systems.
AbstractThe minor and trace element composition of minerals provides critical insights into a variety of geological processes. Multi-element mapping by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is an important technique applied for this purpose and although the method is rapidly advancing, there remains a fundamental compromise between spatial resolution, detection limit, and experiment duration when using sequential mass analyzers. To address the limitation of limited analyte selection for high spatial resolution maps imposed by the sequential nature of typical quadrupole (Q)-ICP-MS, we tested the Aerosol Rapid Introduction System (ARIS) for repeat mapping of the same area. The ARIS is a high-speed transfer tubing system that reduces aerosol washout times, permitting resolution of individual pulses at 40–60 Hz. Here, the ARIS was tested not for pulse resolution but with novel operating conditions optimized to perform fast, high spatial resolution mapping of minor and trace element distribution in pyrite and marcasite. For this purpose, ablation was conducted with a 5 µm beam aperture, a repetition rate of 50 Hz, and a continuous stage scan speed of 40 µm s−1. For each LA-Q-ICP-MS map, data were acquired for six elements with an acquisition time of 20 ms per element. This deliberately reduced the individual pulse resolution of the ARIS but instead exploited the spatial resolution and sensitivity gains afforded by the high-laser repetition rate combined with efficient aerosol transfer. The new method successfully mapped trace elements at single to double-digit parts per million levels, and the maps reveal fine-scale zoning of trace elements with an effective x and y resolution of 5 µm, while white light interferometry showed that for each experiment, only ca. 1 µm of the sample was removed. Repeated mapping of the same area showed excellent correspondence not only between element concentrations in successive experiments but also in the shape, dimension, and location of regions of interest defined by concentration criteria. The very good repeatability of the elemental maps indicates that for studies requiring more analytes, successive mapping of additional elements is possible. By contrast with conventional very small spot (i.e., 5 µm) analysis, fast repetition rate and stage scan speed mapping avoids down-hole fractionation effects and minimizes accidental analysis of buried invisible inclusions. Compared to conventional LA-ICP-MS mapping, the method reduces the experiment time by 4–8 times.
Molten sulfur is found in various subaerial volcanoes. However, limited records of the pools and flows of molten sulfur have been reported: therefore, questions remain regarding the physicochemical processes behind this phenomenon. A suite of new sulfur flows, some of which active, was identified at the Lastarria volcano (northern Chile) and studied using satellite imagery, in situ probing, and temperature and video recording. This finding provides a unique opportunity to better understand the emplacement mechanisms and mineral and chemical compositions of molten sulfur, in addition to gaining insight into its origin. Molten sulfur presented temperatures of 124–158°C, with the most prolonged sulfur flow reaching 12 m from the source. Photogrammetric tools permitted the identification of levees and channel structures, with an estimated average flow speed of 0.069 m/s. Field measurements yielded a total volume of 1.45 ± 0.29 m3 of sulfur (equivalent to ∼2.07 tons) mobilized during the January 2019 event for at least 408 min. Solidified sulfur was composed of native sulfur with minor galena and arsenic- and iodine-bearing minerals. Trace element analysis indicated substantial enrichment of Bi, Sb, Sn, Cd, as well as a very high concentration of As (&gt;40.000 ppm). The January 2019 molten sulfur manifestations in Lastarria appear to be more enriched in As compared to the worldwide known volcanoes with molten sulfur records, such as the Shiretoko-Iozan and Poás volcanoes. Furthermore, their rheological properties suggest that the “time of activity” in events such as this could be underestimated as flows in Lastarria have moved significantly slower than previously thought. The origin of molten sulfur is ascribed to the favorable S-rich chemistry of fumarolic gases and changes in host rock permeability (fracture opening). Molten sulfur in Lastarria correlates with a peak in activity characterized by high emissions of SO2 and other acid species, such as HF and HCl, in addition to ground deformation. Consequently, molten sulfur was framed within a period of volcanic unrest in Lastarria, triggered by changes in the magmatic-hydrothermal system. The appearance of molten sulfur is related to physicochemical perturbations inside the volcanic system and is perhaps a precursor of eruptive activity, as observed in the Poás and Turrialba volcanoes.
Use of the solvent-free mechanochemical method for a sustainable preparation of pharmaceuticals
(2023)
With the growing interest in environmental issues on the part of governments and institutions, pharmaceutical industries are asked to reduce their environmental footprint. Given the major impact related to the use of solvents, the development of methodologies less solvent demanding is nowadays even more urgent. In light of that, mechanochemistry would be a suitable solvent-free technology since it promotes the activation of the chemical reactions between (generally) solid materials via inputs of mechanical energy. Since such reactions may occur outside the kinetic and thermodynamic rules of conventional solution chemistry, the main limit of mechanochemistry is the poor mechanistic understanding of the solid-state transformations involved, which is still hindering a widespread use of the method, as well a scale-up to the industrial level. However, the development of methods for real-time monitoring of the mechanochemical reactions enables obtaining (in)accessible information on reaction intermediates, new products, or reaction time, thus getting closer to a better understanding of the mechanistic behaviour. With the rules of this chemistry becoming increasingly clear, the new reaction pathways of mechanochemistry wouldn’t represent a limit anymore, but an asset, that may lead to lot of opportunities for the pharmaceutical industry.
Thermal Destruction of PFAS
(2023)
Thermal treatment processes are currently the only full-scale option for thedestruction of per- and polyfluoroalkyl substances (PFAS) in large waste streams. While all organic molecules including PFAS are susceptible to thermal destruction, their decomposition rates are controlled by process variables such as temperature, reaction atmosphere, and residence time. Concerns exist about the formation of products of incomplete destruction and their emission from hazardous waste incinerators. This talk will summarize the current stateof-the-art of thermal PFAS destruction, identify research needs, and showcase future research designed to address critical knowledge gaps.
The application of compact NMR instruments to continuously flowing samples at higher temperatures or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is typically not designed for compensation of such effects. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements using an optical thermo-graphy setup, a model predictive control was set up to minimize any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, potentially extend the application of compact NMR instruments to flowing samples at higher temperature than the permanent magnet.
The BAMline at the synchrotron X-ray source BESSY II (Berlin, Germany) is supporting researchers especially in materials science. As a non-destructive characterization method, synchrotron X-ray imaging, especially tomography with hard X-Rays, plays an important role in structural 3D characterization. The imaging capabilities allow for in-situ and operando experiments. In this presentation the data handling pipeline is presented.
This report summarizes findings from the first comprehensive study on digitalization in conformity assessment in Africa. The reults are based on data from a survey among conformity assessment bodies (CABs) conducted in 2023. It highlights the digital maturity of the organizations, the motives, benefits and obstacles of digital transformation as well as the actual technology trends.
This study is part of a global project that covers various other countries (see www.qi-fokus.de).
In this paper, we demonstrate the value of 1H NMR relaxometry for studying the hydration of clinker-reduced, more climate-friendly cementitious binders. The results were obtained on typical CEM I cements and sister samples containing two different reactive agricultural ashes as well as non-reactive biochars as supplementary cementitious materials. The findings prove that time-resolved NMR measurements provide valuable additional information when combined with classical heat flow calorimetry.
High polarity analyte(s) in aqueous media: determination of L-PFOA and L-PFOS in ground water
(2022)
The CCQM-K156 comparison was coordinated by TUBITAK UME on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA).
Perfluoro alkyl substances (PFAS) such as PFOS and PFOA have been used in numerous industrial applications and products. Because of their high stability and resistance to biodegradation, atmospheric photooxidation, direct photolysis and hydrolysis, they are extremely persistent in the environment. The European Union (EU) Water Framework Directive lists PFOS as a priority hazardous substance that poses a significant risk to the aquatic environment. The use of PFOS-containing Aqueous Film-Forming Foams (AFFFs) has been banned since June 2011 in the EU. As relatively water-soluble, effectively non-degradable compounds, PFOS and PFOA migrate to ground water. They are not removed in the conventional drinking water treatment, and therefore cause health risks in polluted areas. The EU Drinking Water Directive and the European Commission has proposed a limit value of 100 ng/L for the sum of 20 PFAS, including PFOS and PFOA.
This study provides the means for assessing measurement capabilities for determination of high polarity measurands in a procedure that requires extraction, clean-up, analytical separation and detection. Successful participation in CCQM-K156 demonstrates measurement capabilities in determining mass fraction of organic compounds, with a molecular mass of 200 g/mol to 700 g/mol, having high polarity pKow -2, in a mass fraction range from 0.5 ng/kg to 500 ng/kg in aqueous media.
Nine NMIs and DIs participated in the CCQM-K156 key comparison. Seven institutes reported their results. SPE was applied in the sample pre-treatment and LC-MS was applied for detection. All participating laboratories applied isotope dilution mass spectrometry (IDMS) techniques for quantification. Participants established the metrological traceability of their results using certified reference materials (CRMs) from NMIs with stated traceability; where commercially available high purity materials were used the purity was determined in-house. The CCQM-K156 results for L-PFOA and L-PFOS range from 2.75 ng/kg to 5.50 ng/kg with a % RSD of 19.5 % for L-PFOA and from 2.04 ng/kg to 4.45 ng/kg with a % RSD of 21.3 % for L-PFOS. The KCRV was assigned using a Hierarchical Bayesian Random Effects Model (HB REM) estimator from the values reported by six of the participants. One participant result of L-PFOS and one result of L-PFOA were excluded from the KCRV for technical reasons. The KCRV was 4.9 ng/kg ± 0.4 ng/kg for L-PFOA and 3.8 ng/kg ± 0.4 ng/kg for L-PFOS. The six institutes that were included in the assignment of consensus KCRV all agreed within their standard uncertainties.
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
AbstractIn this study, we present a screening method based on molecular absorption spectrometry to study PFAS uptake and fate in plants. To evaluate the suitability of this method we analyzed plant extracts with molecular absorption spectrometry (MAS) as well as liquid chromatography–tandem mass spectrometry (LC–MS/MS) for mass balance studies (w(F)). French bean plants (Phaseolus vulgaris) were grown on soil spiked using eight PFAS substances that vary in chain length and functional group composition. Specifically, these include three short-chained (C4–C5), five long-chained (C7–C10) carboxylic acids, one sulfonic acid and one sulfonic amide moieties. To investigate substance-specific PFAS uptake systematically, PFAS were spiked as single substance spike. Additionally, we studied one mixture of the investigated substances in equal proportions regarding w(F) and four PFAS mixtures of unknown composition. After 6 weeks, the plants were separated into four compartments. We analyzed the four compartments as well as the soil for extractable organically bound fluorine (EOF) by high resolution-continuum source-graphite furnace-molecular absorption spectrometry (HR-CS-GFMAS) as well as for sum of ten target-PFAS by LC–MS/MS. All three short-chained PFAS perfluorobutanoic acid (PFBA), perfluorobutanoic sulfonic acid (PFBS) and perfluoropentanoic acid (PFPeA) were determined in high concentrations mainly in the fruits of the investigated plants while long-chained PFAS perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA) were mainly determined in roots. PFBS was determined in remarkably high concentrations in leaves compartment by both quantification methods. Overall, comprehensive results of single substance spikes were in good agreement for both methods except for a few cases. Hence, two phenomena were identified: for mixed PFAS spikes of unknown composition huge differences between EOF and sum of target PFAS were observed with systematically higher EOF values. Overall, both methods indicate comparable results with MS being more reliable for known PFAS contamination and MAS being more valuable to identify PFAS exposure of unknown composition.
Graphical Abstract
The lack of traceability to meter of X-ray Computed Tomography (CT) measurements still hinders a more extensive acceptance of CT in coordinate metrology and industry. To ensure traceable, reliable, and accurate measurements, the determination of the task-specific measurement uncertainty is necessary. The German guideline VDI/VDE 2630 part 2.1 describes a procedure to determine the measurement uncertainty for CT experimentally by conducting several repeated measurements with a calibrated test specimen. However, this experimental procedure is cost and effort intensive. Therefore, the simulation of dimensional measurement tasks conducted with X-ray computed tomography can close these drawbacks. Additionally, recent developments towards a resource and cost-efficient production (“smart factory”) motivate the need for a corresponding numerical model of a CT system (“digital twin”) as well. As there is no standardized procedure to determine the measurement uncertainty of a CT system by simulation at the moment, the project series CTSimU was initiated, aiming at this gap. Concretely, the goal is the development of a procedure to determine the measurement uncertainty numerically by radiographic simulation. The first project (2019-2022), "Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU" developed a framework to qualify a radiographic simulation software concerning the correct simulation of physical laws and functionalities. The most important outcome was a draft for a new guideline VDI/VDE 2630 part 2.2, which is currently under discussion in the VDI/VDE committee. The follow-up project CTSimU2 "Realistic Simulation of real CT systems with a basic-qualified Simulation Software" will deal with building and characterizing a digital replica of a specific real-world CT system. The two main targets of this project will be a toolbox including methods and procedures to configure a realistic CT system simulation and to develop tests to check if this replica is sufficient enough. The result will be a draft for a follow-up VDI/VDE guideline proposing standardized procedures to determine a CT system's corresponding characteristics and test the simulation (copy) of a real-world CT system which we call a "digital twin".
Referenzmaterialien sind unter anderem ein wichtiges Werkzeug zur Qualitätskontrolle von Messungen bestimmter Merkmalswerte. Dabei ist zu berücksichtigen, dass zertifizierte Merkmalswerte immer eine gewisse Unsicherheit haben. Die Ermittlung dieser Unsicherheitsbeiträge ist Gegenstand des Vortrags. Referenzmaterialien sind gleichzeitig ein wertvolles Werkzeug zur Ermittlung der Unsicherheit von Messverfahren und -Analysen unbekannter Proben. Die Vorgehensweise bei der Ermittlung der Messunsicherheit mit Hilfe eines Referenzmaterials wird beschrieben.
An introductory lecture on the Dark Side of Science; what it is, why it exists, and what can be done to fight it. This lecture illuminates the increasing prevalence of fraudulent scientific work (e.g. faked data, manipulated images, paper mills) with plenty of examples and sources. The second section expands on the driving forces that caused this phenomenon to emerge, largely driven by pressures from management, peers and the researcher themselves. The third section expands on methods and tools that can be used to educate and arm oneself against this phenomenon. The 2023 edition includes new examples of larger fraudulent bodies of work emerging, and the problems posed by the arrival of LLMs.
The project series CTSimU was initiated with the goal to develop a set of procedures to enable the determination of the task-specific measurement uncertainty of a CT system numerically by radiographic simulation. The first project (2019-2022) “Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU” was focused on the sufficient physical correctness of the radiographic simulation and created as a result a test framework for simulation softwares and a draft of a VDI standard in the series VDI/VDE 2630 for this application. However, for the realistic simulation of a CT system in a simulation software (i.e. a digital twin), not only the correctness of the simulation software itself is crucial, but also the quality of the parameterization of the CT system in the simulation software - this represents the starting point of the 2nd project “Realistic Simulation of real CT systems with a basic-qualified Simulation Software - CTSimU2” (2022-2024).
The parameterization of a CT system in a simulation software can be divided into four steps: after the data acquisition at the real CT system (step 1) follows the evaluation of the acquired data for the generation of general parameter specifications (step 2). It follows the transfer of the parameters into the specific simulation software (step 3) and the validation of the resulting simulation parameters by a suitable test (step 4). The intended result of the project CTSimU2 is a draft VDI standard (for VDI/VDE 2630) for this test, which contains an informative annex on the state of the art regarding the possibilities for parameter determination.