Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Vortrag (1068) (entfernen)
Sprache
- Englisch (1068) (entfernen)
Referierte Publikation
- nein (1068)
Schlagworte
- Concrete (39)
- LIBS (36)
- Nanoparticles (32)
- NDT (30)
- Fluorescence (27)
- Traceability (25)
- Synchrotron (24)
- Additive manufacturing (23)
- X-ray scattering (23)
- Metrology (22)
Organisationseinheit der BAM
- 6 Materialchemie (339)
- 1 Analytische Chemie; Referenzmaterialien (338)
- 8 Zerstörungsfreie Prüfung (287)
- 6.1 Oberflächen- und Dünnschichtanalyse (122)
- 1.1 Anorganische Spurenanalytik (99)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (88)
- 6.3 Strukturanalytik (84)
- 4 Material und Umwelt (70)
- 1.4 Prozessanalytik (61)
- 8.5 Röntgenbildgebung (58)
Volatile organic compounds (VOCs) emitted by furniture and building materials can cause health issues. For an improvement of indoor air quality low emitting materials should be used. Quality assurance and –control (QA/QC) measures require an emission reference material (ERM) with a predictable emission rate of VOCs. The idea is to use porous materials as ERM, which store the VOCs inside their pores and emit them constantly.
Volatile organic compounds (VOCs) emitted by furniture and
building materials can cause health issues. For an
improvement of indoor air quality low emitting materials
should be used. Quality assurance and –control (QA/QC)
measures require an emission reference material (ERM) with a
predictable emission rate of VOCs. The idea is to use porous
materials as ERM, which store the VOCs inside their pores and
emit them constantly.
Isotope analysis plays a critical role in various disciplines, including environmental science, archaeology, and forensic investigations. Traditional methods such as mass spectrometry provide precise isotopic data but often require complex, costly setups and extensive sample preparation. As an alternative, optical spectrometry has emerged as a versatile and less invasive technique. This presentation explores the advancements and applications of optical spectrometry methods in isotope analysis, emphasizing their benefits and challenges.
Lithium (Li), Boron (B), Nitrogen (N), Magnesium (Mg), and Calcium (Ca) are pivotal elements across various spheres such as the hydrosphere, biosphere, and lithosphere, significantly impacting (bio-) geochemical and physiological processes. These elements exhibit stable isotopes with substantial roles in geological, environmental, and biological studies. The traditional method for measuring isotope amount ratios has been through mass spectrometry, which, despite its accuracy, comes with high operational costs, the need for skilled operators, and time-consuming sample preparation processes.
Combining optical spectroscopy with chemometrics introduces an innovative, cost-effective approach by the hand of high-resolution continuum source atomic and molecular absorption spectrometry (HR-CS-AAS and HR-CS-MAS) for the analysis of isotope ratios in Li, B, N, Mg, and Ca. By analyzing the atomic or molecular absorption spectrum of the in-situ generated cloud of atoms of diatomic molecules (e.g., Li, BH, NO, MgF, CaF) during the electronic transition from the fundamental state, this method allows for the rapid determination of isotope ratios directly from sample solutions without the need for complex sample preparation.
For each element, the respective atomic or molecule's absorption spectrum was deconvoluted into its isotopic components using partial least squares regression or machine learning algorithms. Robust calibration models were developed, calibrated with enriched isotope, and validated against certified reference materials. Spectral data underwent preprocessing to optimize the modeling to determine the optimal number of latent variables.
The findings showcase that this optical spectrometric method yields results that agree with those obtained via inductively coupled plasma mass spectrometry (ICP-MS), offering a promising, cost-effective, and rapid alternative for isotope analysis with precisions as low as ± 0.2‰. This approach is a significant advancement in analytical chemistry, providing a new way to study isotope variations in biological, environmental, and geological samples.
What does GD-OES reveal about the aging and manufacturing processes of lithium-ion batteries?
(2024)
Glow-Discharge Optical Emission Spectroscopy (GD-OES), a powerful analytical technique, sheds light on the two critical aspects of lithium-ion batteries (LIBs): manufacturing and aging 1, 2. We optimized cell production in manufacturing by adjusting parameters, including cathode doping, electrolyte concentration, and pressing force. GD-OES provided in-depth elemental composition and homogeneity analysis, which is crucial for identifying optimal manufacturing conditions. These findings were validated by electrochemical impedance spectroscopy, confirming the quality of the manufactured batteries.
Shifting the focus to aging, we use GD-OES for fluorine depth profiling, a key element in understanding polymer and electrolyte degradation. However, fluorine presents analytical challenges. We addressed this by substituting argon with a neon:argon mixture, which significantly enhanced fluorine detection sensitivity. This advancement not only improves accuracy but also holds the potential to guide sustainable and cost-efficient manufacturing strategies.
Through its versatility, GD-OES has proven to be a powerful tool for not only optimizing LIB manufacturing processes but also gaining deeper insights into their aging mechanisms. This research extends beyond academic interest, offering tangible benefits for the industry by translating into improved battery quality, extended lifespan, and overall performance.
The ongoing geo-political conflicts and the increasing need for the implementation of measures to improve the energetic system sustainability are increasing the importance of tanks for storing cryogenic fluids in the energy industry. The most common example of cryogenic tank applications is the transport of natural gas and hydrogen in their liquid form (LNG and LH2 respectively) for which, considering the same transport volume cryogenic storage ensures significantly higher transport capacities with respect storage based solely on overpressure.
A common feature of all cryogenic transported fluids is that their condition must be maintained minimizing heat leaks from the environment as much as possible. This is achieved by the implementation of thermal super Insulations (TSI) systems based on e. g. rock wool, perlites, microspheres, multilayer insulations (MLI), and vacuum which have proven to be effective in applications. However, due to the relatively short period of use in some applications, the small number of documented incidents, and the still few investigations carried out in the field, the exploitation of such systems in the cryogenic fluids transport sector still suffers from insufficient knowledge about the course and consequences of incidents. Accidents involving collisions, fires, and their combination are quite common in the transportation sector and may generate extraordinary loads on the tank and its insulation system, eventually leading to tank failure.
The present study focuses on the behavior of TSI systems in tanks when it is exposed to an external heat source representative of a hydrocarbon fire scenario. This may cause an increase of the heat flux into a tank by several orders of magnitude with respect to normal design conditions, thus inducing severe and in the TSI, causing the rapid release of flammable gas and even resulting in a Boiling Liquide Expanding Vapour Explosion (BLEVE).
To study such scenarios a test rig was developed at BAM that allows testing of TSI at industrial conditions and enables subsequent analysis of TSI samples. This test rig considers the typical double-walled design of tanks for cryogenic fluids with vacuum and an additional insulating material in the interspace. Adjustable electrical heating elements simulate the fire on one side of the double wall. This process allows the implementation of repeatable heat loads of up to 100 kW/m². The other side of the double wall is represented by a fluid-supported heat exchanger, which allows the simulation of cold or cryogenic conditions in the test rig, and to determine the heat flux transmitted through the double wall. Thus, the test rig allows thermal loading and performance analysis of TSI samples at the same time.
In the presentation, the results of diverse tested TSI systems will be presented and discussed. As a result of this study, the list of advantages and disadvantages for the choice of tested TSI expands. Within the test, all samples degraded as a consequence of a hydrocarbon fire-orientated thermal load. Strong differences in the behavior of the tested TSI systems over temperature, location, and time were observed. Additionally, the tested MLI insulations were significantly more resistant to their base materials. These results are relevant for the design, the definition of national and international regulations, the Risk assessment, and the development of safety concepts for cryogenic tanks.
In order to reduce the human footprint of CO2 emissions and limit global warming effects hydrogen combustion is becoming increasingly important. To enable fuel cells and gas turbines to operates this carbon free fuel, unprecedently large amounts of hydrogen need to be produced and safely transported and stored. The investigation of the effects of accidents involving hydrogen is therefore becoming of outmost importance. Since hydrogen is usually stored and transported under pressure, one scenario to be considered is the release of hydrogen from a leakage with subsequent ignition. The resulting jet flame must be characterized with respect to the thermal radiation emitted into the environment to define safety regulations. Various models that characterize the resulting flame shape and radiation already exist in the literature, but these are mainly based on empirical data from hydrocarbon jet flames.[1-4] To verify these models, a H2 Jet Flame project conducted at BAM, is investigating the safety of momentum driven hydrogen jet flames. For this purpose, large-scale tests are carried out at the Test Site Technical Safety (BAM-TTS). The object of the investigations is to assess the effects of real scale release scenarios regarding flame geometry and the thermal radiation emitted. Parameters such as release angle, leakage diameter (currently 1 mm to 10 mm), pressure (currently up to max. 250 bar) and mass flow (up to max. 0.5 kg/s) are varied. In addition, influences such as the type of ignition, ignition location as well as delayed ignition can also be investigated. The gained knowledge will be compared with existing jet flame models, to validate these and identify a possible need for further development. In particular, the focus will be laid on the thermal radiation of hydrogen flames. The challenge here is the visualization and characterization of the flame geometry in an open environment. Visualization is performed using infrared (IR) camera systems from at least two viewing angles. Measurements of the heat radiation of jet flames, which can be found in the literature, are mostly based on unsteady outflow conditions.The experimental setup used here allows for the generation of a steady-state outflow for several minutes and thus a direct comparability with existing (steady-state) models. Furthermore, the tests can be carried out for comparative measurements with hydrocarbons (methane, etc.) as well as mixtures of hydrogen and hydrocarbons.
Therapeutic monoclonal antibodies are the fastest-growing group of biological agents which generated a yearly turnover of USD 210 billion in 2022 and whose sales are expected to grow by 10% annually over the next 10 years. With steadily increasing market importance, analytical methods for reliable quantification of therapeutic antibodies also become more and more relevant. Liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) has become the main technology for antibody quantification. This approach, however, requires enzymatic digestion of the intact protein into peptides, for which a wide range of different protocols exists that often lead to different results depending on the digestion procedure or trypsin variants used. In particular, the amount and type of detergents added for protein unfolding prior to digestion is known to create significant bias in measurement results. The overall goal of the presented project is the application of novel thermostable and surface-functionalized trypsin particles for improved antibody digestion. Specifically, a trypsin-variant described in the literature exhibiting increased activity and thermal stability above 80°C, will be examined. The application of this enzyme should allow to perform digestion at elevated temperatures where the protein is naturally unfolding thereby increasing enzyme accessibility without the need for detergents. Furthermore, we will immobilize the thermostable trypsin onto the surface to further enhance enzyme stability, prevent self-digestion, and enable separation of trypsin from target peptides before LC–MS/MS analysis. As an immobilization platform, cheap and non-porous corundum particles will be used as these show high chemical stability and low levels of interaction of matrix proteins with the functionalized surface. adsorption. In a multidisciplinary collaboration with the SALSA Photonics Lab, we will investigate the characteristics of covalent enzyme binding and unspecific peptide binding using an interface-sensitive analytical tool, vibrational sum-frequency generation (VSFG) spectroscopy. The insights gained will not only lead to new competencies in peptide and enzyme surface analysis using VSFG spectroscopy in SALSA but will also significantly contribute to optimizing antibody quantification.
The MBLabs consortium comprises various organizations that operate testing facilities encompassing a broad spectrum of tests relevant to the construction sector, particularly building envelopes. In the future, additional testing facilities will join the METABUILDING platform to offer their services. These services will be integrated in the MBLabs Open Innovation Test Bed and accessible via the METABUILDING platform. The METABUILDING platform is operated by the METABUILDING association.
In Task 8.5 the Quality Assurance system of the MBLabs OITB is developed. The presentation gives an overview regarding the development of this system after 3 years of project execution.
This presentation highlights ongoing scientific misconduct as found in academic literature. This includes data- and image manipulation, and paper mills. Starting with an expose of examples, it delves deeper into the causes and metrics driving this phenomenon. Finally a range of possible tools is presented, that the young researcher can use to prevent themselves from sliding into the dark scientific methods.
By automatically recording as much information as possible in automated laboratory setups, reproducibility and traceability of experiments are vastly improved. This presentation shows what such an approach means for the quality of experiments in an X-ray scattering laboratory and an automated synthesis set-up.
Metabolomics
(2024)
In industrialised countries more than 80% of the time is spent indoors. Products, such as building materials and furniture, emit volatile organic compounds (VOCs), which are therefore ubiquitous in indoor air. VOC in combination may, under certain environmental and occupational conditions, result in reported sensory irritation and health complaints. Emission concentrations can become further elevated in new or refurbished buildings where the rate of air exchange with fresh ambient air may be limited due to improved energy saving aspects. A healthy indoor environment can be achieved by controlling the sources and by eliminating or limiting the release of harmful substances into the air. One way is to use (building) materials proved to be low emitting. Meanwhile, a worldwide network of professional commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. A laboratory’s proficiency can be proven by internal and external validation measures that both include the application of suitable emission reference materials (ERM). For the emission test chamber procedure according to EN 16516, no artificial ERM is commercially available. The EU-funded EMPIR project MetrIAQ aims to fill this gap by developing new and improved ERMs. The goal is to obtain a material with a reproducible and temporally constant compound release (less than 10 % variability over 14 days). Two approaches were tested: the impregnation of porous materials with VOC, and the encapsulation of VOC in polymer microcapsules. Impregnation is performed with help of an autoclave and supercritical CO2. The encapsulation is done by interfacial polymerisation on VOC droplets. For both approaches, synthesis and/or material parameters were varied to obtain an optimal ERM. Findings about the optimisation of ERM generation, as well as performance of the best emission reference materials, will be presented.
The principles of (Hard) X-ray photoelectron spectroscopy and some application in the field of (core-shell) nanoparticles will be presented. The presentation should answer hoe to get reliable results. Furthermore, examples of the correlation between physical-chemical measurments and toxicological results are given which are crucial for the risk assessment of nanoparticles.
Climate change and increasing demand for electricity require the use of power electronics based on new wide bandgap (WBG) compound semiconductors. Power electronics devices are used in numerous application areas to control and convert electric energy. These may include generation and distribution of renewable energy for green hydrogen, electrification of transport or 5G communication. WBG electronics have much higher efficiency than the silicon-based ones and can operate at higher power densities, voltages, temperatures and switching frequencies with low energy losses. However, defects in the semiconductors can considerably affect the performance of power electronic devices or make their operation even impossible. The presentation will show the application of spectroscopic and imaging ellipsometry as well as white light interference microscopy for defect characterisation in SiC, GaN and Ga2O3 over a wide wavelength range.
We used parameterized modelling of ellipsometric transfer parameters to determine the dielectric properties of bulk materials and thin layers. Imaging ellipsometry offers more information and is an advanced variant of optical microscopy, combining the lateral resolution of optical microscopy with the extreme sensitivity to surface and interface effects of ellipsometry. Surface topography and morphology of different types of defects were additionally investigated with imaging white light interference microscopy. Modern electronic thin film components require complex surface analysis methodologies and hybrid metrology. Hybrid measurement techniques enable fast and non-destructive traceable characterisation of thin film compound semiconductors as well as accurate detection and identification of defects. This methodical approach leads to a better understanding of the materials themselves and of the defect formation mechanisms during manufacturing.
This work aims to enable highly reproducible manufacturing of compound semiconductor power electronics as well as operation monitoring to ensure failure-safety of electronic systems in power electronic devices.
An overview of personal experience with laser-induced plasma (LIP) will be given. The combination of LIP with laser-induced fluorescence, atomic absorption, Raman spectroscopy and spatial heterodyne spectroscopy for elemental and isotopic analysis will be discussed. Unusual applications of LIP will be covered, such as LIP-based lasers and LIP-based chemical reactors.
This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, micro reactions, pump and probe diagnostics, tomography,
temporal and spatial resolution. Basis of plasma computer modeling will be presented.
Until the 1980s radiography was used to inspect civil structures in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Meanwhile, non-destructive techniques such as ultrasound or
radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features when applied to reinforced or prestressed concrete inspection.
Muon tomography has received much attention recently. Muons are particles generated naturally by cosmic rays in the upper atmosphere and pose no risk to humans. Novel detectors and tomographic imaging algorithms have opened new fields of application, mainly in the nuclear sector, but also in spectacular cases such as the Egyptian pyramids.
As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results have been at least of similar quality compared to ultrasonic and radar imaging, potentially even better. Recently, the research was expanded to more realistic testing problems such as the detection of voids in certain structural elements. However, before practical implementation, more robust, mobile, and affordable detectors would be required as well as user-Friendly imaging and simulation software.
Ellipsometry is a very powerful tool used for accurate material investigation in a wide wavelength range. It is a non-destructive and fast method. Imaging ellipsometry as a combination of optical microscopy and ellipsometry enables spatially resolved measurements when determining the layer thickness and dielectric properties of thin layers. It is known for its high polarisation sensitivity and high contrast for the surface structures. In this contribution we show the application of the imaging ellipsometry for detection of defects in energy materials and quality validation of possible reference materials for nano-electronics.
Defects in wide bandgap semiconductors, in homoepitaxial SiC and heteroepitaxial GaN layers on transparent SiC substrates, can be successfully detected and classified by means of imaging ellipsometry. Correlation of imaging ellipsometry results with results from complementary techniques such as white light interference microscopy as well as atomic force microscopy contribute to understanding of surface topography and defect formation mechanisms. We discuss the potential of different methods for analysing ellipsometric map data for monitoring the defect densities.
Electric properties of materials at the nanoscale can be investigated by means of scanning probe microscopy methods such as scanning microwave microscopy and conductive atomic force microscopy. However, development of new robust and easy-to-use calibration methods and calibration standards is essential to increase the traceability of these methods and allow their broad application in industry. We show how imaging spectroscopic ellipsometry can be used for development and monitoring of processing quality of patterned reference samples based on indium tin oxide (ITO) layer with different thickness and conductivity.
The built infrastructure ages and requires regular inspection and, when in doubt, monitoring. To ensure that older concrete bridges showing signs of deterioration can be used safely, several innovative monitoring tools have been introduced, including but not limited to optical, fiber-optic, or acoustic emission techniques. However, there are gaps in the portfolio. A sensing technique that covers a wide range of damage scenarios and larger volumes, while still being sensitive and specific, would be beneficial.
For about 15 years, research has been conducted on ultrasonic monitoring of concrete structures that goes beyond the traditional ultrasonic pulse velocity test (PV test), mostly using a very sensitive data evaluation technique called coda wave interferometry. At BAM we have developed sensors and instrumentation specifically for this method.
We have instrumented a 70-year-old, severely damaged prestressed concrete bridge in Germany in addition to a commercial monitoring system. We have now collected data for almost 3 years. We can show that we can provide information about the stress distribution in the bridge. We have also been able to confirm that there has been no significant additional damage to the bridge since the installation.