Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (1183)
- Vortrag (1072)
- Posterpräsentation (443)
- Beitrag zu einem Tagungsband (175)
- Forschungsdatensatz (56)
- Sonstiges (30)
- Buchkapitel (24)
- Forschungsbericht (23)
- Dissertation (15)
- Beitrag zu einem Sammelband (13)
Sprache
- Englisch (3065) (entfernen)
Schlagworte
- Nanoparticles (114)
- Fluorescence (111)
- Concrete (89)
- LIBS (81)
- Mechanochemistry (72)
- Quantum yield (72)
- Ultrasound (71)
- SAXS (69)
- Non-destructive testing (68)
- Nanoparticle (63)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1092)
- 6 Materialchemie (980)
- 8 Zerstörungsfreie Prüfung (775)
- 6.1 Oberflächen- und Dünnschichtanalyse (348)
- 6.3 Strukturanalytik (328)
- 1.1 Anorganische Spurenanalytik (277)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (232)
- 1.2 Biophotonik (214)
- 4 Material und Umwelt (186)
- 8.5 Röntgenbildgebung (169)
Paper des Monats
- ja (27)
Expansion dynamics of laser-induced plasma is studied for different focal positions of the ablation laser in the pressure range 10-2 - 105 Pa of the ambient air. The experimental results indicate that both the parameters significantly affect the plasma size, shape, intensity, reproducibility, and distance from the target surface. At pressures above 10 Pa, the plasma plume is confined by the ambient gas; the plumes are more compact and travel shorter distances from the target as compared to the analogous plume characteristics at pressures below 10 Pa. The pulse-to-pulse reproducibility of the integral emission intensity of the plasma is also different for different focal positions and pressures. It is found that the focal positions -1 cm and -2 cm below the target surface yield the most reproducible and intense emission signals as measured at the 600 ns delay time with the 100 ns gate. The information obtained can be of importance for pulsed laser deposition, laser welding, and analytical spectroscopy at reduced pressures. In general, a correct choice of the focal position and pressure of an ambient gas is very important for obtaining the strongest plasma emission, good reproducibility, and desired plasma plume shape.
Thermal waves are solutions of the heat diffusion equation for periodic boundary conditions and can be seen analogously to strongly damped waves. Although the underlying differential equation differs from the wave equation, the essential property for analogy between both equations is linearity such that superposition applies. This linearity is maintained even after a linear transformation, such as the Fourier transform from time to frequency domain. It follows that the temporal superposition principle is already used in active thermography, e.g. in pulsed thermography, as a superposition of many individual frequencies. However, the systematic spatial superposition has not yet been fully exploited, mainly due to a lack of suitable energy sources.
As a first step, we are investigating how thermal wave fields of arbitrary space-time structures can be engineered using structured laser illumination. The proof of principle was shown using a laser coupled projector. Unfortunately, the available optical output power was limited due to the thermal stress limit of the device. That is why we are working towards a more sophisticated moving 1D array of high-power diode lasers. We characterized the novel light source and believe that apart from the benefit of spatial and temporal illumination it can combine the temporal regimes of impulse and lock-in thermography.
In a second step, we investigate moving and oscillating line sources with different line shapes. We use a Green’s Function ansatz to analytically model the thermal wave propagation of structured 1D laser illumination in isotropic materials. Furthermore, we show some methods how they can be implemented. With this technique, we were able to accelerate our detection method firstly presented in for vertical narrow defects by factor three. Generally, we believe that this technique opens up similar opportunities than in other NDE methods. High-resolution ultrasound, for example, is also based on the superposition of single emitters and a recent concept suggests an option to deal with the diffusion wave character of the thermal waves.
Thermographic NDE is based on the interaction of thermal waves with inhomogeneities. These inhomogeneities are related to sample geometry or material composition. Although thermography is suitable for a wide range of inhomogeneities and materials, the fundamental limitation is the diffusive nature of thermal waves and the need to measure their effect radiometrically at the sample surface only. The propagation of the thermal waves from the heat source to the inhomogeneity and to the detection surface results in a degradation in the spatial resolution of the technique. A new concerted ansatz based on a spatially structured heating and a joint sparsity of the signal ensemble allows an improved reconstruction of inhomogeneities. As a first step to establish an improved thermographic NDE method, an experimental setup was built based on structured 1D illumination using a flash lamp behind a mechanical aperture. As a follow-up to this approach, we now use direct structured illumination using a 1D laser array. The individual emitter cells are driven by a random binary pattern and additionally shifted by fractions of the cell period. The repeated measurement of these different configurations with simultaneously constant inhomogeneity allows for a reconstruction that makes use of joint sparsity. With analytical-numerical modelling or numerical FEM simulations, we study the influence of the parameters on the result of non-linear reconstruction. For example, the influence of the illumination pattern as a variable heat flux density and Neumann boundary condition for convolution with the constant Green's function can be studied. These studies can be used to derive optimal conditions for a measurement technique.
Currently BAM is making efforts to recode COMAR, the database for CRMs and reshape its profile as a database intended for qualitatively top-of-the-market CRMs. These efforts are highlighted and placed into the broad perspective of the international RM markets. A link to EPTIS, the database for PT schemes as a blueprint for the recoding is provided.
COMAR, where do you go?
(2018)
Nanocrystalline basaluminite [Al4OH10(SO4)(H2O)3–5] and Aggregation of the e-Keggin polyoxocation [Al12(AlO4)(OH)24(H2O)12]7+, referred to as Al13, have both been described to form in acid mine Drainage environments. Although the chemical composition is quite similar, their crystalline varieties significantly differ, demonstrating that various types of Al-hydroxysulfates can form under similar conditions and that their respective formation is not fully understood yet. Here, we report the occurrence of nanocrystalline precipitates that form naturally in a small alpine catchment in Switzerland where an acidic mountainous stream (pH 4) is neutralized successively after mixing with several neutral tributaries. The stepwise neutralization in conjunction with the large amount of precipitates provide an ideal setting for obtaining new insights into (i) the structure of naturally forming Al-hydroxysulfates, (ii) their formation mechanism, (iii) their role in controlling the solubility of Al, and (iv) their ability to lower the mobility of As. Synchrotron-based high-energy X-ray diffraction and subsequent pair distribution function analyses demonstrate that these precipitates are structurally identical to basaluminite samples obtained from acid mine drainage sites. In contrast, only minor amounts of tetrahedrally coordinated Al, as present in Al13, were identified by nuclear magnetic resonance spectroscopy. The precipitates are further characterized by elevated As concentrations up to 600 lg/g, whereas other heavy metals are at background concentrations only. Given the low As concentrations in the stream from which precipitation occurs (<0.03 mg/L), high As concentrations confirm that basaluminite serves as a highly efficient As sink, which is attributed to its high anion-exchange capacity. Chemical analysis of streamwater samples in combination with geochemical modeling show that precipitation occurs instantaneously upon mixing with neutral streams.
Moreover, our data reveal that the precipitation of basaluminite exerts a strong solubility control on dissolved Al concentrations as manifested by the quasi-constant basaluminite ion activity product observed during neutralization from pH 5 to pH 5.9. We hypothesize that in our field system, high fluoride and sulfate concentrations on the order of 100 and 1–2 mg/L,
Improvement of effectiveness of in-service inspection in nuclear power plants (IAEA-TECDOC-1853)
(2018)
This publication represents a consensus among experts drawn from the IAEA and global practitioners to compile a set of common or good individual practices for use at nuclear power plants to improve ISI effectiveness. It sets forth a number of strategies and practices for improving the effectiveness of ISI and investigates the role of ISI in maintaining or improving safety at plants and the relationship of ISI improvement to cost. Strategies for improving ISI effectiveness are discussed, with consideration given to the entire framework of ISI, including effective selection of the proper inspection scope, inspection interval and NDE efficiency.
This publication is an update of the publication IAEA-TECDOC-1400, Improvement of In-service Inspection in Nuclear Power Plants, which was published in 2004. It takes into account new techniques and technologies for qualification processes for methodologies, equipment, procedures and personnel as well human factors in NDE inspections.
TiO2 anatase nanoparticles are among the relevant players in the field of light-responsive semiconductor nanomaterials used to face environmental and energy issues. In particular, shape-engineered TiO2 anatase nanosheets with dominant {001} basal facets gained momentum because of the possibility to exploit different and/or improved functional behaviors with respect to usual bipyramidal TiO2 anatase nanoparticles, mainly exposing {101} facets. Nevertheless, such behavior depends in a significant extent on the physicochemical features of surfaces exposed by nanosheets.
They can vary in dependence on the presence or removal degree of capping agents, namely, fluorides, used for shape-engineering, and experimental investigations in this respect are still a few. Here we report on the evolution of interfacial/ surface features of TiO2 anatase nanosheets with dominant {001} facets from pristine nanoparticles fluorinated both in the bulk and at their surface to nanoparticles with F− free surfaces by treatment in a basic solution and to totally F− free nanoparticles by calcination at 873 K.
The nanoparticles fluorine content and its subsequent evolution is determined by complementary techniques (ion chromatography, TOF-SIMS, XPS, AES, SEM-EDX), probing different depths. In parallel, the evolution of the electronic properties and the Ti valence state is monitored by UV−vis spectroscopy and XPS. The calcination treatment results in {001} facets poorly hydroxylated, hydrated, and hydrophilic, which appear as surface features consequent to the expected (1 × 4) reconstruction. Moreover, IR spectroscopy of CO adsorbed as probe molecule indicates that the Lewis acidity of Ti4+ sites exposed on (1 × 4) reconstructed {001} facets of calcined TiO2 nanosheets is weaker than that of cationic centers on {101} facets of bipyramidal TiO2 anatase nanoparticles. The samples have also been tested in phenol photodegradation highlighting that differences in surface hydration, hydroxylation, and Lewis acidity between TiO2 nanoparticles with nanosheet (freed by F− by calcination at 873 K) and bipyramidal shape have a strong impact on the photocatalytic activity that is found to be quite limited for the nanoparticles mainly exposing (1 × 4) reconstructed {001} facets.
3D imaging techniques have an enormous potential to understand the microstructure, its evolution, and its link to mechanical, thermal, and transport properties. In this conference paper we report the use of a powerful, yet not so wide-spread, set of X-ray techniques based on refraction effects. X-ray refraction allows determining internal specific surface (surface per unit volume) in a non-destructive fashion, position and orientation sensitive, and with a nanometric detectability. We demonstrate showcases of ceramics and composite materials, where microstructural parameters could be achieved in a way unrivalled even by high-resolution techniques such as electron microscopy or computed tomography. We present in situ analysis of the damage evolution in a carbon fibre reinforced polymer and a Al/Al2O3metal matrix composite during tensile load, the direct observation of damage accumulation during creep of Al-3.85Mg and the identification of void formation (different kinds of defects, particularly unsintered powder hidden in pores, and small inhomogeneity’s like cracks) in Ti64 parts produced by selective laser melting using synchrotron X-ray refraction radiography tomography.
Measuring means knowing. The structural engineer’s Knowledge about structures is vitally important for the assessment of their structural safety. This contribution shows, how non-destructive testing methods can be used to collect valuable Information about existing structures. This value is expressed in this paper by the usability in probabilistic assessments and thus by the reliability of the information. The development of non-destructive testing methods in civil-engineering allows the realistic measurement and visualization of inner constructions of concrete components with a minimum of destructive interventions.
The evaluation of the quality of measurement data is of fundamental importance for quantitative measurements in order to ensure the objectivity of testing and evaluation and to assess the reliability of the knowledge acquired. Both systematic and random deviations must be identified, quantified and taken into account to obtain statistically sound data. The Focus of this contribution is on the methodical path, how displayed measurement data can be processed into reliable knowledge.
It is not about developing assessment methods but about providing
necessary knowledge to increase their operational usability.
This study focuses on the analysis of a corpus of manuscripts found in Fustat (medieval Cairo, Egypt) in the biggest medieval “archive” found until now: the Cairo Geniza. The giant collection of mostly Jewish documents has been attracting scholars’ attention a lot but so far, the material aspects of these documents seem to have been mainly neglected.
Application of scientific methods of analysis, especially X-Ray fluorescence characterization, contributes to our understanding of the materials used for production of manuscripts during the Middle ages.
Our corpus of the 11th century manuscripts comprises manuscripts written by scribes belonging to three Jewish communities that co-existed in Cairo during this period: the Karaites, the so-called Jerusalemites (or Palestinian) and the so-called Babylonians (or Iraqi), three different communities with different traditions and different leaders. The differences manifest themselves also in the paleographical properties of the manuscripts produced within each community. Can we extend the differences detected by the paleographical analysis to differences in composition of the writing materials and especially the composition of the inks? Or can we relate the differences in the composition to the manuscript type (legal, private...), or to another criterion. In this presentation, we offer answers to some of the questions using statistical analysis of the measurements results.
Measuring means knowing. The structural engineer’s Knowledge about structures is vitally important for the assessment of their structural safety. This contribution shows, how non-destructive testing methods can be used to collect valuable Information about existing structures. This value is expressed in this paper by the usability in probabilistic assessments and thus by the reliability of the information. The development of non-destructive testing methods in civil-engineering allows the realistic measurement and visualization of inner constructions of concrete components with a minimum of destructive interventions.
The evaluation of the quality of measurement data is of fundamental importance for quantitative measurements in order to ensure the objectivity of testing and evaluation and to assess the reliability of the knowledge acquired. Both systematic and random deviations must be identified, quantified and taken into account to obtain statistically sound data. The Focus of this contribution is on the methodical path, how displayed measurement data can be processed into reliable knowledge.
It is not about developing assessment methods but about providing
necessary knowledge to increase their operational usability.
X-ray photoelectron spectroscopy (XPS) provides elemental and chemical information from the outermost ~10 nm of the sample surface. This is in the same order of magnitude as the thickness of the outer bacterial membrane of gram-negative bacteria, as well as outer membrane molecules as exopolysaccharides and lipopolysaccharides, commonly attached to the cell surface. With the development of near-ambient pressure (NAP)-XPS, bacteria can be analysed with minimal sample preparation.
EnviroESCA is a laboratory based NAP-XPS instrument, equipped with a monochromated Al Kα radiation source and a differentially pumped energy analyser connected to an exchangeable sample environment. It allows for measurements in various gas-atmospheres, including water vapor, which makes it possible to characterise bacteria and other biological samples close to their natural, hydrated state. Artificial model-biofilms of exopolysaccharides, planktonic Pseudomonas Fluorescens and biofilms of Escherichia Coli have been characterised in hydrated and dried state.
High-resolution XPS-spectra from carbon, oxygen, nitrogen and phosphorous can be assigned to carbohydrates, lipids and proteins in general agreement with literature. Especially the carbon 1s peak is of interest. A series of measurements of an E. coli biofilm from 11 mbar in humid environment to 1 mbar air reveal changes in the C1s peak, which suggests that the bacterial surface undergo substantial Change.
The CLEAN ENERGY Flagship is an initiative designed to utilize recent game changing developments in digital, materials and manufacturing technologies to catalyze a radical paradigm shift towards clean, reliable, efficient and cost-optimal energy.
Unifying and drastically accelerating radically new energy material design, processing and integration across the entire value chain addressing energy production, conversion, storage and systems.
CLEAN ENERGY participants are all distinguished research organisations that each benefit from their own industry networks and contacts with regions and state-level activities and have a long history of collaborating with each other (for 10 years now under the umbrella of EERA) within a European collaborative framework.
Through EERA, CLEAN ENERGY aims to become a crucial partner in the SET-Plan, supporting long-lasting approaches through its established networks and internal collaborations.
The equation of state for plasmas containing negative and positive ions of elements and molecules formed by these elements is modeled under the assumption that all ionization processes and chemical reactions are at local thermal equilibrium and the Coulomb interaction in the plasma is described by the Debye–Hückel theory. The hierarchy problem for constants of molecular reactions is resolved by using three different algorithms for high, medium, and low temperatures: the contraction principle, the Newton–Raphson method, and a scaled Newton–Raphson method, respectively. These algorithms are shown to have overlapping temperature ranges in which they are stable. The latter allows one to use the developed method for calculating the equation of state in combination with numerical solvers of Navier–Stokes equations to simulate laser-induced Plasmas initiated in an atmosphere and to study formation of molecules and their ions in such plasmas. The method is applicable to a general chemical network. It is illustrated with examples of Ca–Cl and C–Si–N laser-induced plasmas.
Laser induced plasma (LIP) is a highly dynamic, short living event which presents significant difficulty for both diagnostics and modeling. The former requires precise spatially- and time-resolved measurements on a micron-nanosecond scale while the latter needs numerous descriptive parameters; many of them can only be obtained from experiment. Diagnostics and modeling should always complement each other for obtaining a truthful picture of LIP.
In this presentation, a newly developed collisional-dominated model will be presented. The model is based on the coupled Navier-Stokes, state, radiative transfer, material transport, and chemical equations. The model incorporates plasma chemistry through the equilibrium approach that relies on atomic and molecular partition functions. Several chemical systems are modeled including Si-C-Cl-N and B-H-Cl systems.
The model is used to study the equilibrium states of the systems as functions of the concentrations of plasma species and plasma temperature. The model also predicts the evolution of number densities of atomic and molecular species in the expanding plasma plume.
This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, microreactions, pump and probe diagnostics, tomography, temporal and spatial resolution. Basics of plasma computer modeling will be presented.
This poster deals with improvements and characteriztion of small-angle scattering limitations, by looking at the trifecta of Data collection and uncertainty propagation, data analysis methodologies, and real-world tests. It is found that - with appropriate care and instrumentation - accuracies of 1% on mean nanomaterial sizes, and 10% on the size distribution width as well as the volume fraction can be achieved.
Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects. Material defects are often simulated by flat-bottom holes (FBH) or grooves. Typically, analytical 1D models are used to determine the defect depth of FBHs, grooves or delaminations. However, these models cannot take into account lateral heat flows, or only to a limited extent (semi-empirical model). They are therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Here, we present an approach for quantitative determination of the geometry of FBH or grooves. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a FBHs or groove and its diameter or width, respectively. The model takes lateral heat flows into account as well as thermal losses. Figure 1 shows the temperature increase of a pulsed thermography measurement at three different locations on the sample. The numerical model is fitted to the experimental data (red lines) to quantify the groove. The numerical simulation matches the experimental data well.
The formation and alignment of gel fibres in alkanes (solvents) was investigated. The gel fibres consist of small amphiphilic molecules containing a C60 molecule and a small ligand chain. Under the right conditions, these self-assemble in core-shell micelles, which themselves pack into micron-sized fibre-like structures. These can be aligned using a strong magnetic field, as investigated using SANS with a 17T superconducting magnet at a range of field strengths.
More than 80 representatives of SMEs, industrial companies and research institutes met on September 12 at the workshop "Challenges in Additive Manufacturing: Innovative Materials and Quality Control" at BAM in Adlershof to discuss the latest developments in materials and quality control in additive manufacturing.
In special lectures, researchers, users and equipment manufacturers reported on the latest and future developments in additive manufacturing. Furthermore, funding opportunities for projects between SMEs and research institutions on a national and European level were presented.
The technique of painting on the reverse side of a glass panel was rediscovered by German artists at the beginning of the 20th century. In contrast to other paint techniques (e.g. panel and mural painting), the paint layers are applied in reverse succession starting with the foremost paint layer and ending with the primer (backmost layer). The paintings are viewed in reflected light, thus revealing an impressive gloss, luminosity and depth of colour. The artist group “Der Blaue Reiter” (the Blue Rider) around W. Kandinsky and F. Marc got in touch with this technique in the summers of 1908 and 1909 and spread their knowledge in different regions. Our pioneering project is tracing this transfer of knowledge by a multidisciplinary approach in terms of art history, painting technology and material science. More than 100 artists and >1000 reverse paintings on glass (1905-1955) were identified during the project. This numbers clearly point out that this technique was by far more important for modern art than previously assumed. In-situ, non-invasive measurements (XRF, Raman, VIS, DRIFTS) on a well-considered selection of 67 paintings reveal the broad palette of colorants ranging from traditional to experimental materials. Special attention is paid on artists who are strongly connected to Berlin. Demonstrative examples by W. Dexel, G. Muche and L. Hildebrandt are used to discuss analytical challenges and highlights.
ALCOREF is a project within the European Metrology Programme for Innovation and Research (EMPIR. It is part of the 2016 EMPIR Research Potential Call dedicated to build up metrological and research capacity in less developed National Metrology Institutes (NMIs).
The project will develop long term expertise for the production and certification of ethanol/water reference materials in the participating NMIs. Materials to be developed will be suitable for the calibration and approval of evidential breath alcohol analysers as defined by recommendation R 126 of the International Organization of Legal Metrology (OIML). Certification includes the characterisation of the materials, assessment of homogeneity, stability and uncertainty. Target certified values and volumes will address end-users’ needs regarding regional legal limits for alcohol in traffic and the instrumentation for breath analyser calibration available in different countries. Thus, the project supports the law enforcement of national drink-driving legislation.
The consortium comprises of 11 institutions from 10 European countries. Project participants will establish reliable analytical methods for the purity assessment of ethanol, such as Karl-Fischer titration, to achieve traceability of their certified values. Chromatographic or density methods for the quantification of ethanol in water will also be established, validated and applied for homogeneity and stability assessment. An interlaboratory comparison will be conducted within the European Association of National Metrology Institutes’ (EURAMET) Technical Committee Metrology in Chemistry to test the equivalence of the new certified reference materials and the analytical methods implemented.
The poster will present the outline and first results of the ALCOREF project.
This study focuses on the analysis of a corpus of manuscripts found in Fustat (medieval Cairo, Egypt) in the biggest medieval “archive” found until now: the Cairo Geniza. The giant collection of mostly Jewish documents has been attracting scholars’ attention a lot but so far, the material aspects of these documents seem to have been mainly neglected.
Application of scientific methods of analysis, especially X-Ray fluorescence characterization, contributes to our understanding of the materials used for production of manuscripts during the Middle ages.
Our corpus of the 11th century manuscripts comprises manuscripts written by scribes belonging to three Jewish communities that co-existed in Cairo during this period: the Karaites, the so-called Jerusalemites (or Palestinian) and the so-called Babylonians (or Iraqi), three different communities with different traditions and different leaders. The differences manifest themselves also in the paleographical properties of the manuscripts produced within each community. Can we extend the differences detected by the paleographical analysis to differences in composition of the writing materials and especially the composition of the inks? Or can we relate the differences in the composition to the manuscript type (legal, private...), or to another criterion. In this presentation, we offer answers to some of the questions using statistical analysis of the measurements results.
The Cairo Geniza is an “archive” discovered in the 19th century in Ben Ezra Synagogue in Fustat, a district in Old Cairo (Egypt), located south of the center of modern Cairo. The giant collection of mostly Jewish documents that vary in genres, languages and writing supports contains a large number of early medieval Hebrew manuscripts, mostly in fragmentary form. The larger part of the Cairo Geniza is stored today in the Cambridge University Library (CUL).
The Geniza provides sources for the literary, linguistic, historical studies of the various aspects Jewish life. As the documents attest, at least two Jewish communities co-existed in Fustat up to 11th century: a so-called Babylonian and Palestinian. These communities had different leaders, different traditions and lived independently. The differences seem to manifest themselves also in the paleographical, codicological and some material properties of the manuscripts produced by each community.
The aim of this project is to compare the inks used in the Jewish documents depending on different variables: support (paper, parchment), purpose of the manuscript (legal, private, religious), provenance of the scribe. For the determination of the inks type and composition we had to choose non-invasive, non-destructive and portable techniques to analyse the corpus directly in the CUL.
The analyses were carried out with a mobile energy dispersive micro-X-ray spectrometer ArtTAX® (Bruker GmbH, Berlin, Germany), which consists of an air-cooled, low-power molybdenum tube, polycapillary X-ray optics (measuring spot size 70 µm in diameter), an electrothermally cooled Xflash detector, and a CCD camera for sample positioning (Bronk et al 2001, Hahn et al. 2010). All measurements are executed using a 30 W low-power Mo tube, 50 kV, 600 µA Mo tube, and with an acquisition time of 15 s (live time) to minimize the risk of damage (Fig. 1, 2).
Fig. 1: XRF spectrometer probe above a manuscript fragment
Fig. 2: Typical element profile of a XRF linescan
The Dino Lite digital stereomicroscope (Fig. 3) features built-in LED illumination at 395 nm and 940 nm and a customized external white light source. During use, the microscope is fastened to a small tripod or mounted on a Plexiglas ring holder that incorporates a white light source.
Fig. 3: Dino Lite digital stereomicroscope
Fig. 4: Details of one fragment (T-S 16.124) observed with the Dino microscope (x20). On the left, when illuminated with NIR (Near-Infrared, 940 nm) light, the ink fades, indicating iron-gall ink. On the right, the image under NIR light does not change. It is carbon ink.
On example of these studies is the manuscript T-S 16.124 (Cambridge University Library, Fig. 5) whom belongs to the third corpus. It is a deed, written in Hebrew, dated from 1328 (= 1017 CE) and witnessed by a very high number of people (6) comparing to the standard of similar documents (between 2 and 3), from at least two different Jewish communities in Fustat (trans congregational). The verso is written in Arabic (Bareket 1999).
Fig. 5: Manuscript T-S 16.124 (Cambridge University Library)
To compare the inks, we used the fingerprint model. This method relies on the determination of characteristic elemental compositions and represents the amount of a minor constituent relative to the main component, iron in iron gall ink (Malzer et al. 2004, Hahn et al. 2004, Rabin et al 2014). However, a calculation of a fingerprint based on XRF measurements is not possible in the case of carbon ink since carbon, its main component, cannot be detected with this technique.
Fig. 6: Ink fingerprint T-S 16-124 (recto) normalized to iron (Fe)
Conclusion
We show that using reflectography and XRF analysis it is possible to sort the inks according to their type. In the case of the iron-gall inks, use of the ink fingerprint, i.e. amount of the vitriol components normalized to iron we can make direct comparisons of the ink composition.
We would like also to stress that though the methods of material analysis listed above have been successfully employed in the field of cultural heritage and conservation including ancient and medieval manuscripts they have not yet been used to study fragments from the Cairo Genizah. Therefore, we believe that this research project is a pioneering study that will provide new insights into the history of Hebrew writing materials, their production techniques and materials and, thus, contribute new data to the field of Hebrew paleography.
The Cairo Genizah is a well-known “archive” discovered in the 19th century in Ben Ezra Synagogue in Fustat, a district in Old Cairo (Egypt), located south of the center of modern Cairo. The giant collection of mostly Jewish documents that vary in genres, languages and writing supports contains a large number of early medieval Hebrew manuscripts, mostly in fragmentary form. The larger part of the Cairo Genizah is stored today in the Cambridge University Library, containing about 200,000 fragments.
The Genizah provides sources for the literary, linguistic, historical studies of the various aspects Jewish and non-Jewish life. As the documents attest, at least two Jewish communities co-existed in Fustat up to 11th century: a so-called Babylonian and Palestinian. These communities had different leaders, different traditions and lived independently. The differences manifest themselves also in the paleographical properties of the manuscripts produced by each community.
Although Genizah manuscripts have attracted a great deal of scholarly attention, the material aspects of these documents seem to have been largely neglected. The current study aims to obtain information on the composition of the writing supports and the inks used, in order to obtain insights on trade, local production techniques and social structures.
Can we extend the differences detected by the paleographical analysis to differences in composition of the writing materials ? Can we relate the differences in the composition to a community, to the manuscript type (legal, private...), or to another criterion?
While studying the socio-geographic history of inks, division 4.5 of the BAM (Bundesanstalt für Materialforschung und Prüfung) together with the Centre for the Study of Manuscript Cultures in Hamburg has developed a protocol for ink analysis. It consists of a primary screening to determine the type of the ink, and a subsequent in-depth analysis using several spectroscopic techniques. The XRF elemental analysis aims primarily at understanding the fingerprints of inks containing metals, making it possible to distinguish among different inks.
Our own research aims primarily at recreating a socio-geographic history of inks, parchment, and papyrus and includes the comparative analysis of the writing materials of the Dead Sea Scrolls, ink and papyrus in Ancient and Hellenistic Egypt, and inks in documents from various contemporary medieval communities in Fustat (first nucleus of Cairo). During many years of study, we concluded that the continuous production of Coptic manuscripts from late Antiquity to the Middle Ages offers a unique opportunity for historical study of the ink in a large geographic area. Thanks to the collaboration with the ERC project “PAThs” (www.paths.uniroma1.it), based at the University of Rome La Sapienza, and within the activities of a PhD research dedicated to this topic, we therefore created a new branch of our project focused entirely on the analysis of Coptic inks, pigments, and dyes. This pioneering systematic study of writing materials coming from a specific area and time frame (5th-10th century) aims not only at a better understanding of the complex Coptic multicultural and plurilingual society, but also and mainly at clarifying the links among the Coptic and other societies between the ancient and medieval eras. Finally, it will cast light on the history of the technological development of inks in the eastern world, from Antiquity to the middle ages.
While studying the socio-geographic history of inks, division 4.5 of the BAM (Bundesanstalt für Materialforschung und Prüfung) together with the Centre for the Study of Manuscript Cultures in Hamburg has developed a protocol for ink analysis. It consists of a primary screening to determine the type of the ink and a subsequent in-depth analysis using several spectroscopic techniques: XRF, FTIR, and Raman. In most cases, we can obtain satisfactory results using a non-invasive protocol. However, mixed inks that contain no metals evade such a protocol. These inks constitute a heterogeneous group of media used especially in the Middle East and the Islamicate world since at least the 10th century; they are characterized by blending carbon ink and tannins, with or without the addition of vitriol.
Our own research aims primarily at recreating a socio-geographic history of inks, parchment, and papyrus and includes the comparative analysis of the writing materials of the Dead Sea Scrolls, ink and papyrus in Ancient and Hellenistic Egypt, and inks in documents from various contemporary medieval communities in Fustat (first nucleus of Cairo). During many years of study, we concluded that the continuous production of Coptic manuscripts from late Antiquity to the Middle Ages offers a unique opportunity for historical study of the ink in a large geographic area. Thanks to the collaboration with the ERC project “PAThs” (www.paths.uniroma1.it), based at the University of Rome La Sapienza, and within the activities of a PhD research dedicated to this topic, we therefore created a new branch of our project focused entirely on the analysis of Coptic inks, pigments, and dyes. This pioneering systematic study of writing materials coming from a specific area and time frame (5th-10th century) aims not only at a better understanding of the complex Coptic multicultural and plurilingual society, but also and mainly at clarifying the links among the Coptic and other societies between the ancient and medieval eras. Finally, it will cast light on the history of the technological development of inks in the eastern world, from Antiquity to the middle ages.
KorroPad - New Test Method for the Investigation of the Passive Layer Stability of Stainless Steels
(2018)
The KorroPad is a gel-based indicator test designed for the electrochemical determination of the passive layer stability and localization of surfaces of stainless steels threatened by localized corrosion. Different investigations and studies on the performance of the KorroPad as well as field trials by industrial users the have proven the principal suitability of the KorroPad method to assess the passive layer stability of stainless steels. The electrochemical mode of action will be described in detail and also the limitations of the applicability will be demonstrated. The influence of different surface finishes has been investigated and verified by known methods for describing corrosion resistances. As a result, the increased corrosion susceptibility of two ground surfaces has been detected, but also the corrosion resistance of further surface finishes could be confirmed. Furthermore the KorroPad test was used for the investigation of the influence of time and humidity on the passive layer development on different stainless steels.
Bonding strength is crucial on polymers of low surface energy, for clean surfaces limited to 0.5, 1, and 2 MPa for PTFE, PP, and PE. Plasma treatment may improve bonding strength by a factor of 2 (PTFE) or 5 (PP and PE). The efficiency of treatment is usually 10% as both low pressure and atmospheric pressure processes show low topographic conformity.
Besides, lifetime of activation/modification is rather short. Hence, bonding has to be carried out immediately after plasma treatment.
The concept of plasma-assisted ALD (atomic layer deposition) interlayers was introduced in the project HARFE of SENTECH (modification/deposition/in-situ monitoring) and BAM (bonding, characterization, testing). ALD deposition has a high surface conformity and for dielectric films of Al2O3 also a good long-term stability given that the films are dense enough.
Based on TMA and O2/O3 precursors, ALD layer stacks from 60 to 375 monolayers were prepared under different conditions. For a transfer time of 24 hours from deposition to measurement, bonding strength could be increased up to 5 MPa (PTFE) respectively 10 MPa (PP, PE). The huge potential of ALD layers as adhesive interlayers was demonstrated for Al2O3 on stainless steel with bonding strength beyond 15 MPa, i.e. interface
strength within the ALD stack is also in this range.
This is a prerequisite for subsequent PVD/CVD-deposition in hybrid systems. By means of the SI ALD LL system of SENTECH thermal and plasma-supported ALD processes can be alternatively realized.
Ellipsometric in-situ monitoring provides monolayer sensitivity and reveals that the efficient bonding of the lower ALD layers on the polymer has to be further improved. Testing of bonding strength was realized by CAT (centrifugal adhesion testing) technology. It was shown that ALD modification correlates with the increase of surface energy and bonding strength.
The synthesis, characterization, and application of mesoporous materials containing boron–dipyrromethene (BODIPY) moieties that allow the sensitive and selective detection of HgII in aqueous environments by fluorescence enhancement is reported. For this purpose, BODIPY dye I containing a thia‐aza crown ether receptor as the fluorescent probe for the detection of HgII in aqueous environments is encapsulated into mesoporous materials to avoid self‐quenching or aggregation in water. Determination of HgII is accomplished within a few seconds with high selectivity and sensitivity, reaching a limit of detection of 12 ppt. The determination of trace amounts of HgII in natural waters and in fish extracts is demonstrated by using our sensing material. The incorporation of the material into several μ‐PAD strips yields a portable, cheap, quick, and easy‐to‐handle tool for trace HgII analysis in water.
The majority of all products have coated surfaces designed to fulfil different requirements. Building constructions are exposed to external influences like a wide temperature and humidity range, rain and UV radiation to name a few. The extension of machine life for metal cutting tools, like drills or milling cutters is another field of application for coated surfaces. The surfaces have to be modified in a way to maintain their specific functionality. Although adhesion testing of coatings is of great interest, it is still a challenge to obtain reliable quantitative results and to meet economic requirements.
In this talk we deal with the curing behaviour of different 2-component epoxy paint systems for corrosion protection of metal constructions. After preparation of specimens the strength was determined in specified time intervals during curing. It could be shown that epoxy paints differ significantly on curing time as well as final strength. The second experimental study deals with coating systems on glass fibre reinforced plastics which are used for wind power turbines to reduce abrasive wear and ice adhesion for aerodynamic and safety reasons.
All measurements have been carried out by CAT-TechnologyTM (Centrifugal Adhesion Testing), which uses the radially directed centrifugal force as test-load. The multi-sample test instrument analyses up to eight test specimen under identical testing conditions. By varying the rotational speed (100 rpm up to 13,000 rpm), forces from 0.1 N to 6.5 kN are applied. Upon reaching the critical rupture force, the stamp separates from the substrate and a sample related IR-signal is sent from the spinning rotor. For each test specimen breaking force is calculated and displayed in real-time. The innovative measurement principle meets the requirements of DIN EN 15870 and ISO 4624.
The test material EDS-TM001 together with an accompanying software package, “EDX spectrometer check”, have been made available in 2009 by BAM to be employed by EDS (energy dispersive spectrometer) users to check the performance of an EDS attached to the SEM. Particularly for test laboratories operating under accreditation schemes like ISO/IEC 17025, a periodical control of the critical instrumental parameters in end-user laboratories is required. With EDS-TM001 or EDS-TM002 (second generation) test material, this periodical check is simplified to the acquisition of only one 10 kV spectrum. The software “EDX spectrometer check” is destined to evaluate automatically this spectrum and determine the performance of the EDS in terms of energy resolution and calibration as well as possible alteration of low-energy efficiency due to detector contamination. Energy resolution can be compared with the specified values according to the international ISO standard ISO 15632:2012. EDS-TM is a synthetic material consisting of a thick layer of C, Al, Mn, Cu and Zr in a well-defined composition, deposited on a steel (in case of EDS-TM001) or silicon (in case of EDS-TM002) substrate. Meanwhile, more than one hundred laboratories use the EDS-TM001 or EDS-TM002 test material for the periodical check of their EDS. A detailed description of the test material and software together with examples of application was published recently. New results and gained experiences will be presented as well.
When the FWHM of lines appearing in the EDS-TM spectrum are determined, the spectrum background must be subtracted accurately. The applied physical background subtraction procedure is robust and takes into account the transmission of the detector window. While the previous version considers only Moxtek AP windows, the new version includes selection of silicon nitride window and the case of windowless detector. Moreover, the new version allows importing of spectra in Bruker spx format and EMSA/MSA files from EDAX TEAM software.
Extraction of true, 3D shape (and size) of non-spherical nanoparticles (NPs) is associated with errors by conventional 2D electron microscopy using projection images. Significant efforts within the ISO technical committee TC 229 ‘Nanotechnologies’ are aimed at establishing accurate TEM and SEM measurement of NP size and shape as robust, standard procedures. Study groups have been organizing inter-laboratory comparisons on well-selected NP systems according to the market needs, such as aggregated titania nano-powder for which size and shape distribution of primary crystallites of irregular shape must be measured accurately. To be noticed is e. g. the fact that the measurement procedure allows only manual selection of the particles clearly distinguishable for analysis as well as manual definition of the contour of the imaged NPs.
An inter-laboratory exercise on titania NPs (pure anatase, grown by hydrothermal synthesis) of well-defined non-spherical shape, i.e. bipyramidal has been recently started within ISO/TC 229 under similar conditions as for the irregular shaped titania. Overlapped particles were allowed to be considered, as long as they are clearly distinguishable. One decisive NP selection criterion was to analyze only those NPs with a roundness value below 0.7, i.e. the NPs laying on the support foil and, hence, with projection areas clearly deviating from perfect circles (R=1). The overall evaluation (for 15 labs) of the size descriptors (area, Feret, minFeret, perimeter) and shape descriptors (aspect ratio, roundness, compactness, extent) by analysis of variance is just to be finished and included in ISO/WD 21363 Nanotechnologies -- Protocol for particle size distribution by transmission electron microscopy.
A wide range of methods are used to estimate the plant-availability of soil phosphorus (P). Published research has shown that the diffusive gradients in thin films (DGT) technique has a superior correlation to plant-available P in soils compared to standard chemical extraction tests. In order to identify the plant-available soil P species, we combined DGT with infrared and P K- and L-edge X-ray adsorption near-edge structure (XANES) spectroscopy. This was achieved by spectroscopically investigating the dried binding layer of DGT devices after soil deployment. All three spectroscopic methods were able to distinguish between different kinds of phosphates (poly-, trimeta-, pyro- and orthophosphate) on the DGT binding layer. However, infrared spectroscopy was most sensitive to distinguish between different types of adsorbed inorganic and organic phosphates. Additionally, also intermediates of the time-resolved hydrolysis of trimetaphosphate in soil could be analyzed. Furthermore, infrared and XANES microspectroscopy make it also possible to analyze P compounds on the binding layer with a lateral resolution down to 1 µm2. Therefore, P species of a spatial soil segment (e.g. rhizosphere) can be mapped and analyzed.
Trace humidity was measured by using miniaturized planar coulometric sensors in technical gases such as hydrogen, nitrogen, helium, nitrous oxide, and synthetic air. Frost point temperatures tf in the gases ranged from −60 °C to −30 °C, which is equivalent to a vapour mole fraction xv from 10 μmol mol−1 to 376 μmol mol−1. In addition, the generated humidity was determined by using a precision dew point hygrometer as reference. Nonlinear calibration functions were calculated that correlated electric current (sensor signal) and reference humidity. Parameters of functions were tested with one-way analysis of variances (ANOVA) to prove if all used sensors had a similar behavior in the same gas during experiments. Results of ANOVA confirmed that averaged functions can be applied for trace humidity measurement in nitrogen, helium, nitrous oxide, and synthetic air. The calculated functions were negligibly different for nitrogen, helium, and synthetic air. In humidified nitrous oxide, a minor change of parameters was observed due to lower electrical currents. In total contrast to that, the measured sensor signals were significantly higher in humidified hydrogen and each sensor required its own calibration function. The reason was a recombination effect that favoured multiple measurements of water molecules. Nevertheless, it was possible to measure continuously trace humidity in all tested gases by using coulometric sensors with an expanded uncertainty below 2 K (k = 2).
The present study repeats electron probe microanalysis (EPMA) measurements with the thin film analysis software Stratagem on an Fe-Ni thin films on silicon and reports - for the first-time – results of analysis on Si-Ge thin films deposited on a non-conductive aluminium oxide substrate.
If the very good EPMA/Stratagem results for the FeNi system were expected due to previous studies [2], the data obtained for the SiGe films are particularly valuable, because of the challenging insulator substrate of Al2O3. The conductivity of the Si1-xGex surface necessary for charging-free analysis was ensured by applying conductive copper tape onto film surface down to sample stage. Four accelerating voltages, 15, 20, 25 and 30 kV, have been applied, so that the Ge Kα X-ray line at 9.87 keV could be excited.
For the determination of porosity of Ir oxide thin films, electron probe microanalysis (EPMA) can be used as part of a combined SEM/EDS/STRATAGem analysis. The mass deposition (in μg cm-2) of films was calculated with the analysis software STRATAGem via k-values measured with EDS. The average density of coated films was obtained from the mass deposition and the film thickness as measured by the cross-section SEM. The porosity was calculated by dividing the average film density by the bulk (theoretical) density of the film material.
Film porosities were counterchecked by spectroscopic ellipsometry (SE) using the Bruggeman effective medium approximation (BEMA).
The results obtained by both analytical approaches/methods used, SEM/EDS/STRATAGem and SE were in good agreement.
A femto-second pulsed laser ablation in liquid (PLAL) procedure for the generation of titanium oxide nanoparticles (NP) is reported with the purpose of understanding morphology and structure of the newly generated NPs. Ablation duration was varied for optimization of NP generation processes between 10 and 90 min. Surface morphology of NPs as well as their size and shape (distribution) were analysed by various complementary electron microscopy techniques, i.e. SEM, TSEM and TEM. The crystalline structure of titanium oxide particles was investigated by XRD(two instruments operated in different geometries) and HR-TEM. Concentration of generated titanium oxide NPs in liquid was analysed by ICP-MS. A mix of crystalline (mainly anatase), partly crystalline and amorphous spherical titanium oxide NPs can be reported having a mean size between 10 and 20 nm, which is rather independent of the laser ablation (LA) duration. A second component consisting of irregularly shaped, but crystalline titanium oxide nanostructures is co-generated in the LA water, with more pronounced occurrence at longer LA times. The provenance of this component is assigned to those spherical particles generated in suspension and passing through the converging laser beam, being hence subject to secondary irradiation effects, e. g. fragmentation.
Carbamazepine (CBZ) and cetirizine (CTZ) are pharmaceutical drugs detected in the aquatic environment. However, the effects to marine invertebrates derived from the combination of these drugs with decreased pH conditions due to ocean acidification are poorly explored. This study investigated the biochemical parameters related to metabolic capacity and oxidative stress response and the transcription of genes related to the mode of action (MoA) of CBZ (1.0 μg/L) and CTZ (0.6 μg/L) in the clam Ruditapes philippinarum chronically exposed (28 days) to control (7.8) and low (7.5) pH conditions. The biochemical parameters applied were: the activity of electron transport system (indicator of organisms’ metabolic capacity); lipid peroxidation content (indicator of cell damage); total glutathione peroxidase activity (indicator of antioxidant defense). The transcription of genes related with drug neurotransmission and metabolism, cell defense and immunity and biomineralization was studied. No metabolic changes and oxidative stress was induced by the exposure to CBZ or CTZ at each pH level, but the transcription of several genes related with the MoA (neurotransmission, immunity and biomineralization) was altered by low pH, drug exposure and the combination of both stressors. In conclusion, it was shown that the interaction of drug exposure and low pH conditions can change bivalves’ sensitivity to drugs or alter drugs toxicity.
The synthesis, structure, reactivity,and photophysical properties of anovel acidic,luminescentchromium(III) complex [Cr(H2tpda)2]3+ (23+ +)bearing the tridentate H2tpda (2,6-bis(2-pyridylamino)pyridine) ligand are presented. Excitation of 23+ + at 442 nm results in strong, long-lived NIR luminescence at 782 nm in water and in acetonitrile. X-ray diffraction analysis and IR spectroscopy revealhydrogen-bonding interactions of the counter ions to the NH groups of 23+ + in the solidstate. Deprotonation of the NH groups of 23+ + by using anon-nucleophilic Schwesinger base in CH3CN switches off the luminescence. Re-protonation by using HClO4 restores the emission. In water,the pKa value of 23+ + amountsto8 .8, yet deprotonation is not reversible in the presence of hydroxide ions. Dioxygen quenches the emission of 23+ +,but to aweaker extent than expected. This is possibly due to the strong ion-pairing properties of 23+ + even in solution, reducing the energy transfer efficiency to O2.Deuteration of the NH groups of 23+ + approximately doubles the quantum yield and lifetime in water,demonstrating the importance of multiphoton relaxation in these NIR emitters.
Additive manufacturing (AM) offers an effective solution to the medical sector. It enables the production, on demand, of customised implants which match the patient’s anatomy, with grafts that promote bone growth, as well as surgical guides that help the surgeons.
The objective of this project is to provide a comprehensive basis to enable the safe use of medical AM products with traceable and reliable dimensionalmeasurements. This will guarantee the reliability of medical AM products to notified bodies and facilitate acceptance of AM in the medical sector for a better quality of life.
Imaging of Eu doped very small iron oxide nanoparticle in atherosclerotic plaques via LA-ICP-MS
(2018)
Atherosclerotic lesions can be visualized by magnetic resonance imaging (MRI) using very small iron oxide nanoparticles (VSOP). VSOP accumulate in atherosclerotic plaques and thus serve as an atherosclerosis probe.
The aim of this project was to image the distribution of europium doped VSOP (Eu-VSOP) by laser ablation ICP-MS in histological thin cuts of the aortic root region of ApoE knockout mouse model that is rich in atherosclerotic plaques. In addition, it was investigated whether VSOP accumulation in the plaques correlates with other biomarkers of inflammation for example macrophages and altered endothelium to assess whether it correlates with instability or vulnerability of the plaque regions. For this purpose, antibodies were labeled with various lanthanide elements and correlated with the Eu-VSOP distribution using LA-ICP-MS in a multiplex measurement mode.
A possible correlation of reactive nitrogen species (RNS) with endogenous iron or Eu-VSOP can also be detected by LA-ICP-MS. For this purpose, RNS-specific antibodies were also labeled with lanthanides.
Analysis of single cells via LA-ICP-MS is a technique with great potential, however manual targeting of single cells is laborious and therefore microarraying of cells looks promising. In this work, we investigate the potential of a commercial non-contact piezo dispenser arraying system (S3, Scienion AG, Berlin), equipped with a novel technology for single-cell isolation called CellenONE™ (Cellenion, Lyon). Usually if one aims to create a microarray of single cells via spotting a suitably diluted cell suspension, one will observe a Poisson-distributed cell number per spot. CellenONE™ overcomes this problem by controlling the number of cells optically in the piezo dispense capillary (PDC) via image recognition to obtain true single cell arrays. The figures of merit of the customized and optimized setup will be presented. In a proof of concept experiment we investigated the trace elemental fingerprint of THP-1 cells by LA-ICP-TOF-MS (Analyte G2, Teledyne Cetac; icpTOF, TOFWERK) and quantified two metal cell dyes, mDOTA-Ho (CheMatech, Dijon), and Ir-DNA intercalator (Fluidigm, San Francisco). For that, matrix matched calibration standards after Wang et al. were successfully prepared using the same arraying system. We believe that this novel approach opens new ways for automated quantitative single cell LA-ICP-MS.
Quantification of metals in single cells by LA-ICP-MS comparison of single spot analysis and imaging
(2018)
LA-ICP-MS is increasingly used for single cell analysis in two different detection modes using either the imaging mode with subcellular resolution or alternatively single spot analysis of cells with a larger laser spot size. This study compares the analytical figures of merit of both detection modes (signal to noise, precision, accuracy, throughput), as well as ease of operation and data evaluation. Adherent 3T3 fibroblast cells were stained with two metal dyes (mDOTA-Ho, Ir-DNA-intercalator) and several dozen cells were measured using both modes. We found a ten times higher throughput for single spot analysis, which has as well a straightforward data analysis, shortening the total analysis time further. The signal to noise ratio for single spot analysis was found to be slightly better compared to the signal to noise of pixels in imaging. The mean metal intensity per single cell differed by only 10% between both modes and obtained distributions were found to show no statistically significant differences. Using matrix matched calibration based on standards spotted onto nitrocellulose membrane, we achieved detection limits (10 σ) of 12 fg for Ir and 30 fg for Ho and quantified 57 ± 35 fg Ir and 1,192 ± 707 fg Ho per single cell. Compared to a conventional ICP-MS measurement of a digest of ~60,000 cells, 54 % of Ir content and 358 % Ho content was found using quantitative LA-ICP-MS. The difference might be a consequence of the two metal dyes binding to different structures of the cell and therefore might behave differently in sample preparation for conventional and LA-ICP-MS.
In chemical elements with three or more stable isotopes, mass-dependent stable isotope fractionation yields correlated isotope ratios, m2/m1 and m3/m1. In three-isotope space, i.e. in a δ’m2/δ’m1 vs. δ’m3/δ’m1 plot, data align along a slope θ, the so called ‘triple isotope fractionation exponent’ that scales the two isotope ratios. Theoretical calculations predict small differences in θ for kinetic- and equilibrium isotope fractionation (Young et al. 2002) and thus the precise measurement of θ allows constraining the reaction mechanism. However, due to an apparent lack of precision of stable isotope analysis by MC-ICP-MS, θ is merely used as analytical quality control, i.e. for demonstration that samples and standards plot within their analytical precision in the range of theoretical θ-values originating in δ-zero.
We show how θ can be determined precisely enough by MC-ICP-MS to distinguish kinetic- and equilibrium isotope fractionation, even when isotopic differences between samples are low. For low magnitudes of isotope fractionation, we exploit new, isotopically fractionated isotope standard materials (Vogl et al. 2016). We determine quality norms regarding interferences and measurement conditions to warrant trueness and to maximize precision. We exemplary explore the measurement of the three-isotope composition of Mg stable isotopes, budget the uncertainty of θ-values, and report the first θ-values of carbonate-water pairs and bioapatite. Our measurement approach adds a new dimension to isotope data beyond the δ-scale that has a high potential to reveal different modes of (bio)mineral precipitation in the sedimentary and biological record and thus to contribute solving conundrums in the Earth and Life Sciences.
Polyethylene (PE) frits were used to quantify sulphur in copper and its alloys by isotope dilution combined with LA-ICP-MS as an alternative approach to conventional sample preparation: the copper samples were spiked, the spiked samples were dissolved, the resulting solutions were absorbed in the PE frits and finally the PE frits were analysed by LA-ICP-MS. A prerequisite for such a support material is a low sulphur blank and thus PE was selected for this purpose. The absorption efficiency of the PE frits was studied for varying sulphur amounts ranging from 2 mg S to 80 mg S showing that more than 99.5% of the loaded sulphur was absorbed by the frit. The so prepared PE frits were measured by LA-ICP-MS and yielded a good linearity (R2 ¼ 0.999) for the sulphur ion intensities corresponding to sulphur amounts up to 40 mg S; the associated sensitivity is approximately 3.4 x 10⁴ cps μg⁻¹ for ³²S. For the validation of the developed procedure the reference materials BAM-M376a, BAM-228 and BAM-227 were applied such that 2 μg S, 5 μg S and 11 μg S were absorbed in the PE frits, respectively. These samples were pre-quantified for the adsorbed sulphur amount by external calibration LA-ICP-MS yielding sulphur amounts of 0.9 μg, 5.1 μg and 8.5 μg (quantified for ³²S only), respectively. Relative Standard deviations of the isotope ratios were below 5% in average (n ¼ 3 lines) in all cases (except for the pure spike solution). These samples were then analysed by LA-ICP-IDMS and the measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. The obtained relative expanded measurement uncertainties ranged between 10% and 26%. Pearson's coefficient was used to express the correlation between both techniques; the obtained value was 0.999 demonstrating a strong correlation. Contrary to most published LA-ICP-IDMS procedures, the developed procedure enables SI-traceability for the measurement results. The metrological traceability to the SI for the sulphur mass fractions in copper was established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to mass fraction in the samples obtained by LA-ICP-IDMS is presented as well.
Amyloid fibrils are polymers formed by proteins under specific conditions and in many cases they are related to pathogenesis, such as Parkinson’s and Alzheimer’s diseases. Their hallmark is the presence of a β-sheet structure. High resolution structural data on these systems as well as information gathered from multiple complementary analytical techniques is needed, from both a fundamental and a pharmaceutical perspective. Here, a previously reported de novo designed, pH-switchable coiled coil-based peptide that undergoes structural transitions resulting in fibril formation under physiological conditions has been exhaustively characterized by transmission electron microscopy (TEM), cryo-TEM, atomic force microscopy (AFM), wide-angle X-ray scattering (WAXS) and solid-state NMR (ssNMR). Overall, a unique 2-dimensional carpet-like assembly composed of large coexisiting ribbon-like, tubular and funnel-like structures with a clearly resolved protofilament substructure is observed. Whereas electron microscopy and scattering data point somewhat more to a hairpin model of β-fibrils, ssNMR data obtained from samples with selectively labelled peptides are in agreement with both, hairpin structures and linear arrangements.
Mass spectrometric methods (MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
We propose a lower-cost and faster optical alternative for the analysis of isotope ratios of selected elements: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated mono-hydrides and halide (MH and MX) using graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. The extension of this methodology to other elements like Li, Ca, Cu, and Sr is discussed.
Imaging of elemental distributions in single cell assays as well as tissue sections can be performed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). This powerful technique offers precise spatially resolved measurements at trace and ultratrace levels and has been established as an excellent tool to answer analytical, biological and biomedical questions. To date, mass cytometry is already able to simultaneously detect up to 40 cellular targets due to conjugation of isotopically pure lanthanides to affinity binders, e.g. antibodies.
To further enhance the ability of multiparametric analysis to more than 100 analytes at once, we investigated lanthanide nanocrystals as new, highly sensitive metal tags for identification of targets in clinical cell assays and tissue samples. Multiparametric analysis will be possible by encoding the lanthanide composition of nanocrystals associated to the affinity binders. Nanocrystals showed remarkable potential for sensitive detection in MS due to high stability and signal amplification compared to e.g. polymer tags, carrying fewer metal atoms. Furthermore, the nanocrystals allow multimodal imaging due fluorescence of Eu3+ as well as contrast enhancing properties of Gd3+ in magnetic resonance imaging.
Synthesis of functionalized lanthanide nanocrystals for further bioconjugation was performed with high reproducibility and monodisperse size distribution. For proof of principle, the uptake and distribution of these nanocrystals within the monolayered cell line A549 were investigated by mapping the intensities at subcellular resolution using LA-ICP-MS. It could be shown, that the cells were efficiently labeled with the nanocrystals. Additionally, the bioconjugation of the nanocrystals to antibodies and particularly the preservation of the antibody specificity was investigated using Dot Blot experiments. All in all, the results imply high sensitivity and the possibility of multiparametric analysis by doting various lanthanides into the nanocrystals.
In der klinischen Diagnostik werden für zytometrische Messverfahren bereits eine Reihe von Reagenzien eingesetzt zur Markierung von Antikörper eingesetzt, um die Detektion von Biomarkern mittels Fluoreszenz- oder Flugzeitmassenspektrometrie zu ermöglichen.
Seit kurzem ist auch eine Imaging Mass Cytometry Kombination direkt erhältlich, wodurch der Nachweis von Biomarkern in Gewebeschnitten erreicht werden kann. Dazu wird eine Kopplung von Laser Ablation und induktiv gekoppeltem Plasma Massenspektrometrie eingesetzt, wobei ähnlich der Massenzytometrie, zuvor Antikörper mit Metallen markiert, und im Anschluss mit dem Gewebeschnitt inkubiert werden. Durch die hohe Ortsauflösung können die Biomarker lokalisiert, und zukünftig vielleicht auch quantifiziert werden.
Insbesondere Lanthanide eignen sich als Markierungsmetalle, da sie einen niedrigen Untergrund und chemisch ähnliches Verhalten zueinander aufweisen. Allein durch diese Elemente können bereits etwa 15 Parameter unterschieden werden, was durch isotopenreine Standards weiter gesteigert werden kann.
Vom Markierungsgrad abhängig werden unterschiedlich viele Metalle am Antikörper gebunden, und beeinflussen so die Sichtbarkeit im ICP-MS. Nanopartikel könnten daher eine deutliche Steigerung der Sensitivität bewirken. GdVO4 Nanokristalle scheinen bisher sehr vielversprechend und bieten neben multiparametrischen Anwendungen auch Multimodalität.
Die Synthese der Nanokristalle zeigte hohe Homogenität und Reproduzierbarkeit in Partikelgröße in der Zusammensetzung. Ein erstes Experiment mit einer Zellkultur konnte bereits die effiziente Markierung der Zellen unter Beweis stellen, wobei durch hohe Signalstärke auch subzelluläre Auflösung in der LA-ICP-MS erreicht werden konnte.
Imaging of elemental distributions in single cell assays as well as tissue sections can be performed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). This powerful technique offers precise spatially resolved measurements at trace and ultratrace levels and has been established as an excellent tool to answer analytical, biological and biomedical questions. To date, mass cytometry is already able to simultaneously detect up to 40 cellular targets due to conjugation of isotopically pure lanthanides to affinity binders, e.g. antibodies.
To further enhance the ability of multiparametric analysis to more than 100 analytes at once, we investigated lanthanide nanocrystals as new, highly sensitive metal tags for identification of targets in clinical cell assays and tissue samples. Multiparametric analysis will be possible by encoding the lanthanide composition of nanocrystals associated to the affinity binders. Nanocrystals showed remarkable potential for sensitive detection in MS due to high stability and signal amplification compared to e.g. polymer tags, carrying fewer metal atoms. Furthermore, the nanocrystals allow multimodal imaging due fluorescence of Eu3+ as well as contrast enhancing properties of Gd3+ in magnetic resonance imaging.
Synthesis of functionalized lanthanide nanocrystals for further bioconjugation was performed with high reproducibility and monodisperse size distribution. For proof of principle, the uptake and distribution of these nanocrystals within the monolayered cell line A549 were investigated by mapping the intensities at subcellular resolution using LA-ICP-MS. It could be shown, that the cells were efficiently labeled with the nanocrystals. Additionally, the bioconjugation of the nanocrystals to antibodies and particularly the preservation of the antibody specificity was investigated using Dot Blot experiments. All in all, the results imply high sensitivity and the possibility of multiparametric analysis by doting various lanthanides into the nanocrystals.
Nanoparticles (NPs) have found a wide range of applications in research and industry. Thereby the interaction of NPs with biological systems like cells has become a major field of interest, ranging from medical applications to nanotoxicology. Size, shape and surface modification of the nanomaterials determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. In recent years, it was shown that LA-ICP-MS can provide quantitative as well as distribution information of metal containing nanoparticles (NPs) in cell samples.
Here LA-ICP-MS was applied for the imaging of individual fibroblast cells to study the uptake and intracellular processing of NPs. Our results show that LA-ICP-MS can be used to localize nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time.
ICP-MS was used to determine the composition of the nanomaterials as well as the number of NPs in cells after acid digestion of the samples.
Synthetic peptide pools are used in antigen-specific T-cell assays, which are an important part in vaccine and immunotherapeutic clinical trials. As the analytical characterization is challenging due to the similarity of the single peptides or is expensive due to isotope labeled standards, usually only a pre-characterization of the single peptides is performed. However, a regular quality control of the peptide mix would be highly desirable. Therefore, a cost-efficient high performance liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) method for quality control of a model peptide pool is developed.
Peptides were synthesized using peptides&elephants proprietary libraries of individual peptides (LIPS) technology and purified by reversed-phase chromatography to > 90% each. The lyophilized single peptides were combined to a model peptide pool and analyzed by reversed-phase high-performance capillary liquid chromatography coupled to an orbitrap mass spectrometer. Separation was performed on a capillary reversed phase column (2 μm, ID x L 300 μm x 150 mm) with a linear gradient of acetonitrile + 0,05% trifluoroacetic acid.
After optimizing the injection mode, the gradient elution, the temperature and the additives a model peptide pool was separated. The extracted ion chromatogram (XIC) was studied to confirm the exact masses.
By combination of capillary HPLC and HRMS a new cost-efficient quality control method could be developed for the separation and identification of complex synthetic peptide pools.
This study examines the relationship between the magnetic mesostructure with the microstructure of low carbon steel tungsten inert gas welds. Optical microscopy revealed variation in the microstructure of the parent material, in the heat affected and fusion zones, correlating with distinctive changes in the local magnetic stray fields measured with high spatial resolution giant magneto resistance sensors. In the vicinity of the heat affected zone high residual stresses were found using neutron diffraction.
Notably, the gradients of von Mises stress and triaxial magnetic stray field modulus follow the same tendency transverse to the weld. In contrast, micro-X-ray fluorescence characterization indicated that local changes in element composition had no independent effect on magnetic stray fields.
Lock-in- and flash thermography are standard methods in active thermography. They are widely used in industrial inspection tasks e.g. for the detection of delaminations, cracks or pores. The requirements for the light sources of these two methods are substantially different. While lock-in thermography requires sources that can be easily and above all fast modulated, the use of flash thermography requires sources that release a very high optical energy in the very short time.
By introducing high-power vertical cavity surface emitting lasers (VCSELs) arrays to the field of thermography a source is now available that covers these two areas. VCSEL arrays combine the fast temporal behavior of a diode laser with the high optical irradiance and the wide illumination range of flash lamps or LEDs and can thus potentially replace all conventional light sources of thermography.
However, the main advantage of this laser technology lies in the independent control of individual array areas. It is therefore possible to heat not only in terms of time, but also in terms of space. This new degree of freedom allows the development of new NDT methods. We demonstrate this approach using a test problem that can only be solved to a limited extent in active thermography, namely the detection of very thin, hidden defects in metallic materials that are aligned vertically to the surface. For this purpose, we generate destructively interfering thermal wave fields, which make it possible to detect defects within the range of the thermal wave field high sensitivity. This is done without pre-treatment of the surface and without using a reference area to depths beyond the usual thermographic rule of thumb.
Nowadays the Instrumented Indentation Testing (IIT) is one of the most commonly used methods to determine the mechanical properties of materials in the nano range. This method is already extensive standardized in EN ISO 14577 part 1-4. Because of the great interest of researchers and industries in investigations of time depending material behavior mostly all suppliers of IIT equipment are offering the possibility of dynamic testing. Realizing this development ISO/TC 164/SC3 Hardness Testing has proposed to start the new standardization project “Linear elastic dynamic instrumented indentation testing DIIT”. The development of this standard is accompanied by the first international intercomparing exercise comparing results of dynamic instrumented indentation testing from testing machines using different hardware solutions and different models for data evaluation.
The draft of part 5 of ISO 14577 “Linear elastic dynamic instrumented indentation testing DIIT” specifies verification and calibration of testing machines for carrying out the measurement of the dynamic material response when an oscillatory force or displacement, with amplitudes small in comparison to the prescribed target values, is imparted to the indenter while the indenter is continuously loaded to a prescribed target load or target depth or while the load or displacement is held constant at a prescribed target value. In case of a material showing plastic-elastic behavior, the measured dynamic response is used for continuous evaluation of the dynamic stiffness of the contact as a function of depth and frequency. Using the dynamic stiffness of the contact a reduced dynamic modulus will be calculated. In case of a material showing visco-elastic behavior from the measured dynamic response also the dynamic contact damping coefficient as function of depth and frequency is evaluated continuously. Using dynamic contact stiffness and dynamic contact damping coefficient reduced lost and storage modulus for visco-elastic materials will be calculated.
The main normative requirements of the draft will be presented and discussed in the light of the first results of the intercomparing excise.
In well-annealed thin polymer films, with non-repulsive polymer/substrate interactions, an irreversibly adsorbed layer is expected to from. These adsorbed layers have shown greate potential for technological applications. However, their growth kinetics and molecular dynamics are still not fully understood. This is partly due to the hard accessibility of these layers in thin films. Here, the irreversibly adsorbed layers of homopolymer thin films are revealed by solvent-leaching experiments. First, the growth kinetics of these layers is investigated as a function of annealing time, annealing temperature, leaching time and the original filme thickness. The film thickness, topography and the quality of the adsorbed layer is controlled by Atomic Force Microscopy (AFM). Secondly, the molecular mobility of the adsorbed layer is investigated by Broadband Dielectric Spectroscopy (BDS). A recently developed nanostructured capacitor arrangement is employed to measure the layer with a free surface. The results are quantitatively compared and discussed with respect to recently published work.
The inspection of complex-shaped components, such as those enabled by additive manufacturing, is a major challenge in industrial quality assurance. A frequently adopted approach to volumetric non-destructive evaluation is X-ray computed tomography, but this has major drawbacks. Two-dimensional radiography can overcome some of these problems, but does not generally provide an inspection that is as capable.
Moreover, designing a detailed inspection for a complex-shaped component is a labour-intensive task, requiring significant expert input. In response, a computational framework for optimizing the data acquisition for an image-based inspection modality has been devised. The initial objective is to advance the capabilities of radiography, but the algorithm is, in principle, also applicable to alternative types of imaging. The algorithm exploits available prior
information about the inspection and simulations of the inspection modality to allow the Determination of the optimal inspection configuration, including specifically component poses with respect to the imaging system. As an intermediate output, spatial maps of inspection performance are computed, for understanding spatially varying limits of detection. Key areas of innovation concern the defect detectability evaluation for arbitrarily complex indications and the creation of an application-specific optimization algorithm. Initial trials of the algorithm are presented, with good results.
The identification of transformation products (TPs) of pesticides in food is a crucial task difficult to tackle, due to the lack of standards. In this work, we present a novel methodology to synthesize five main TP standards of the insecticide chlorpyrifos (CPF) and to investigate their occurrence in selected fruits and spices. TPs were electrochemically (EC) synthesized using a boron-doped diamond electrode (BDD) and identified by EC coupled online to mass spectrometry, LC-MS/MS, and high-resolution mass spectrometry. CPF and its TPs were analyzed in the food samples by LC-MS/MS on multiple reaction monitoring (MRM) after dispersive solid-phase extraction. A good recovery of 83–103% for CPF and 65–85% for TPs was obtained. Matrix effects, which cause signal suppression, ranged between 81 to 95% for all targeted analytes. The limit of detection and quantification for CPF were 1.6–1.9 and 4.9–5.7 μg/kg, respectively. Among investigated samples, CPF was determined in fresh lemon (104 μg/kg), fenugreek seed (40 μg/kg), and black pepper (31 μg/kg). CPF content in all samples was lower than the EU maximum residue level (MRL). The most frequently detected TPs were diethylthiophosphate and diethylphosphate. Other TPs, CPF oxon and trichloropyridinol, were also detected. Hence, EC is a versatile tool to synthesize TP standards which enables the determination of contaminants and residues in foodstuffs even if no commercial standards are available.
The international ISO Standard 20579‐4, dealing with the history and preparation of nano‐objects for surface analysis, has been developed to help address some of the replication and reproducibility issues caused by the fundamental nature of nanoobjects.
Although all types of samples requiring surface analysis need thoughtful preparation, nano‐objects, for which many properties are controlled by their surfaces, present additional challenges in order to avoid variations and artefacts due to the handling and preparation of materials prior to analysis. This international standard is part of a series of standards related to preparation of samples for surface chemical analysis. Parts 1 and 2 of ISO Standard series 20579 address general issues that apply to many samples. Part 3, which is still in development, will focus on biomaterials. Part 4 specifically considers issues that arise due to the inherent nature of nano‐objects.
Because of sensitivity to their environment, the standard indicates the minimum Information that needs to be reported about the handling and preparation of nano‐objects prior to surface analysis. This information should become part of sample provenance information that helps assure the reliability and usefulness of data obtained from surface‐analysis in the context of the synthesis, processing, and analysis history of a batch of material. Application of this standard can help address reproducibility and traceability issues associated with synthesis, processing, and characterization of nano‐objects in research and commercial applications.
ISO/TR 19693:2018—Surface chemical analysis—Characterization of functional glass substrates for biosensing applications gives an overview of methods, strategies, and guidance to identify possible sources of problems related to substrates, device production steps (cleaning, activation, and chemical modification), and shelf life (storage conditions and aging). It is particularly relevant for surface chemical analysts characterizing glass‐based biosensors, and developers or quality managers in the biosensing device production community. Based on quantitative and qualitative surface chemical analysis, strategies for identifying the cause of poor Performance during device manufacturing can be developed and implemented. A review of measurement capabilities of surface analytical methods is given to assist readers from the biosensing community.
The LAUS: First applications of a new system for ultrasonic imaging of very concrete structures
(2018)
The LAUS (Large Aperture Ultrasonic System) has been developed to image very thick concrete structures, which are not accessible for commercial systems. The device and the corresponding software is the result of joint research of BAM, an ultrasonic instrument manufacturer and University of Kassel, Germany. It consists of 12 separate arrays of 32 point-contact shear wave transducers each, which can be deployed in flexible configurations. Each array is combined with battery and transmitter, receiver and wireless communication electronics.
Three case histories are presented. First the system was deployed on a 5-m thick heavily reinforced foundation slab. The reflection of the slab’s bottom was imaged clearly. In addition, a multiple reflection was registered, thus giving hope that even thicker elements might be imaged by the instrument. Second, the LAUS was used to investigate a massive bridge girder where a heavy rainstorm during concreting had led to imperfections that were visible after removing the formwork was removed. The LAUS could image tendon ducts in 1.8m depth and the backwall closely behind them. Some limited areas showed blurred reflections and were checked by drill holes; these areas were affected by diffuse damage which could be repaired by injections. Third, a large retaining wall was checked for thickness.
Meanwhile, the LAUS has been used in underground waste deposits (nuclear and other) for quality assurance of sealing plugs. A confirmed penetration depth of about 7 m has been reached.
Previous work has shown that ultrasonic monitoring using externally applied or embedded transducers and imaging methods based on coda wave interferometry are able to detect subtle changes in concrete elements. In this study, a limited number of embedded transducers has been used to monitor changes in several 12 m long two-span concrete beams subjected to point or linear loads until failure.
The ultrasonic results showed the high sensitivity to stress changes and the nonlinear character of the associated effects. However, the ultrasonic features showed a very good correlation to several conventional monitoring parameters. For higher loads (significant amount of cracking), the technique had to be modified to cope with large wave velocity variations and high decorrelation compared to the reference signal.
Using a very simple imaging procedure, the 2D stress field inside the beam has been visualized including inhomogeneities and artifact at places where cracking occurred at higher loads. The technique has the potential to be included in real time monitoring systems.
Small variations in the isotopic composition of some elements have been used as proof of provenance of mineral and biological samples, to describe geological processes, and to estimate a contamination source. Routinely, isotope compositions are measured by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time-consuming and they require a high qualified analyst.
Here, an alternative faster and low-cost optical method for isotope ratio determination is investigated: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X = Li, B, Mg, Ca and Sr have been determined by monitoring the absorption spectra of their in situ generated hydrides (XH) in graphite furnace HR-CS-MAS. For example, the system of two stable isotopes of boron (10B and 11B) was studied via its hydride for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, isotopic composition of samples and reference materials are calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results are metrologically compatible with those reported by mass spectrometric methods. [1] Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shift of their isotopologues can be resolved as shown in Fig.1 b. The extension of this methodology to other elements like Li, Ca and Sr is discussed [2].
References:
[1] C. Abad, S. Florek, H. Becker-Ross, M.-D. Huang, H.-J. Heinrich, S. Recknagel, J. Vogl, N. Jakubowski, U. Panne, Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers, Spectrochim. Acta, Part B, 136 (2017) 116-122.
[2] C. Abad et al., unpublished results, 2018.
We propose an alternative faster and low-cost optical method for isotope analysis: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS).
Stable isotope amount composition of X = Li, B, Mg, Ca and Sr were determined by monitoring the absorption spectra of their in situ generated mono-hydrides (XH) in graphite furnace HR-CS-MAS. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results with an accuracy of 0.15 ‰ are metrologically compatible with those reported by mass spectrometric methods. Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved as shown in Fig.1b. The extension of this methodology to other elements like Li, Ca and Sr is discussed.
Following fluorinated drugs by molecular absorption spectrometry – from cancer cells to body fluids
(2018)
Fluorine has been widely introduced into pharmaceutical drugs. Due to the high C-F bond strength, a single atom substitution with fluorine produces drastic desirable and tunable changes in the molecular properties. However, the clinical monitoring of these drugs is not straightforward.
Organofluorine compounds are elusive for a non-targeted analysis; a significant problem in fluorine determination is the lack of suitable detection techniques. Standard atomic absorption and emission spectrometers cannot access fluorine, because their resonance lines lie in the VUV spectral range below 100 nm. In the case of conventional inductively coupled argon plasmas (ICP), the plasma energy is too low to generate a significant population of excited fluorine atoms. Recently, our group introduces high-resolution continuum source absorption spectrometry (HR-CS MAS) as a new way for the indirect monitoring of fluorinated compounds. Main benefits of HR-CS-MAS includes low limits of detection, complete analyte recovery, simple to no sample preparation, and short time analysis.
The manuscript Codex germanicus 1 (Cod. germ. 1) of the Staats- und Universitätsbibliothek Hamburg is a fifteenth-century German-language manuscript. It comprises two codicological units and has an especially complex developmental history. To trace this developmental history, neglected until now in the research literature, the manuscript was investigated, for the first time not solely with classical codicological and palaeographical methods, but also with the aid of X-ray fluorescence spectroscopy, in order to determine the composition of the writing materials. These methods made it possible, first, to support and check palaeographic findings and, second, to gain information about the stratigraphy of the manuscript where palaeographic methods find their limits – in regard to short entries, rubrications, and non-alphabetical signs.
It is well documented that throughout Antiquity, ancient Egyptians used mostly carbon inks as a writing material. In Late Antiquity, some metals started to be added to carbon based inks. We have records of five manuscripts from the Dead Sea Scrolls collection whose carbon inks were found to contain copper Also, lead was recently found as an additive in carbon inks on a charred fragment from Herculaneum. Furthermore, the earliest evidence of iron-gall ink was found in the Book of Proverbs (Codex Ms. Berol. orient. oct. 987) dating to the third fourth centuries ce. It has been suggested that along with carbon and iron-gall inks, there is no reason to think that purely tannin inks were not also in use in Egypt. However, so far, we just have evidence of a copper-tannin ink identified in a number of documents from Egypt in the first third centuries bce. In an attempt to fill this gap in this extremely fragmented scenario during our studies of the socio-geographic history of inks, we arrived at the conclusion that the continuous production of Coptic manuscripts from Late Antiquity to the Middle Ages offers a unique opportunity for the historical study of inks across a large geographic area.
Advanced codicological studies of Cod. germ. 6 (Hamburg, Staats- und Universitätsbibliothek): Part 2
(2018)
The work presented here follows the article Combining Codicology and X-Ray Spectrometry to Unveil the History of Production of Codex germanicus 6 (Staats- und Universitätsbibliothek Hamburg), published in 2014.1 It confirms the main result of the previous article: the Artusnotiz, the fourth text in the bound manuscript, must have been introduced as the last one. This paper offers further details of the codex production, based on the composition of the black and red inks collected in four measurement campaigns. Furthermore, using imaging μ-XRF, we succeeded in understanding the strong variation of the composition of the red inks in the initials of all the texts except for Parzival and Jeanne d’Arc.
Isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) is emerging in the field of clinical chemistry and laboratory medicine as an alternative to immunoassays and is acknowledged as the MS “gold standard” for small biomolecule quantification. Hepcidin-25, a key iron-regulatory peptide hormone discovered in 2000, has revolutionized the understanding of iron disorders and its quantitative determination in biological samples should advance the management of iron-related pathology (diagnosis, prognosis and treatment). This study applied LC-MS/MS, using the triple quadrupole (QqQ) mass spectrometer, in a rapid and robust analytical strategy for the quantification of hepcidin-25 in human serum, to be implemented in routine laboratories. For this purpose, two sample preparation strategies and two complementary chromatographic separation conditions were investigated, where the use of acidic mobile phases (0.1% trifluoroacetic acid) was compared with a novel approach involving solvents at high pH (containing 0.1% ammonia). The application of these LC-MS/MS methods to human samples in an intra-laboratory comparison, using the same hepcidin-25 calibrators, yielded a very good correlation of the results. The LC-MS/MS employing trifluoroacetic acid-based mobile phases was selected as a highly sensitive (limit of quantification LOQ of 0.5 μg/L) and precise (coefficient of variation CV<15%) method and was recommended as a reference method candidate for hepcidin-25 quantification in real samples (in the dynamic range of 0.5-40 μg/L). One of the novel aspects of the methodology was the use of amino- and fluoro-silanized autosampler vials to reduce the interaction of the 25-residue peptide to laboratory glassware surfaces. Moreover, this LC-MS/MS method was used for an international round robin study, applying a secondary reference material as a calibrator. By determining the degree of equivalence between the results of the ten participating methodologies, the performance of the method developed in this study was found to be in the optimal range as defined by the International Consortium for Harmonization of Clinical Laboratory Results (ICHCLR). In this work, the formation of hepcidin-25 complexes with copper(II) was investigated. The first reversed-phase chromatographic separation of hepcidin-25/Cu2+ and hepcidin-25 (copper “free”) was achieved by applying mobile phases containing 0.1% of ammonia (pH 11). LC-MS/MS and high-resolution mass spectrometry (Fourier-transform ion cyclotron resonance (FTICR) MS) were applied for the mass spectrometric characterization of the formed hepcidin-25-Cu(II) species at pH values of 11 and 7.4 respectively. A new species corresponding to hepcidin-25 complexed with two copper ions was identified at high pH.
Half-Cell-Potential Mapping (HP) is the most popular non-destructive testing (NDT) method for the detection of active corrosion in reinforced concrete. HP is influenced by parameters such as moisture and chloride gradients in the component. The sensitivity to the spatially small, but dangerous pitting is low. In this study we show how additional measurement information can be used with multi-sensor data fusion to improve the detection performance and to automate data evaluation. The fusion is based on supervised machine learning (SML). SML are methods that recognize relationships in (sensor) data based on given labels. We use SML to distinguish "defective" and "intact" labeled areas in our dataset. It consists of 18 measurement - each contains HP, ground radar, microwave moisture and Wenner resistance data. Exact labels for changing environmental conditions were available in a laboratory study on a reinforced concrete slab, which deteriorated controlled and accelerated. The deterioration progress was monitored continuously and corrosion was generated targeted at a predefined location. The detection results are quantified and statistically evaluated. The SML results shows a significant improvement over the best single method (HP).
Common approaches to improve the optical properties of semiconductor quantum dots and lanthanide doped nanophosphors present core/shell structures as radiationless deactivation at the particle surface is usually the main energy loss mechanism. This has led to increasingly sophisticated particle architectures using multishell systems with shells of different chemical composition and thickness and initiated an increasing number of quantitative spectroscopic studies focusing on the key performance parameter photoluminescence quantum yield to identify optimum particle structures. This is particularly challenging in the long wavelength region > 1000 nm and for nonlinear emitters like upconversion nanocrystals. Here, we present suitable absolute methods to quantify the photoluminescence of these different emitters in the vis/NIR/IR and as function of excitation power density and underline the impact of such measurements on a profound mechanistic understanding of the nonradiative deactivation pathways in semiconductor and upconversion nanocrystals of different size and particle architecture in different environments.
DNA origami nanostructures provide a platform where dye molecules can be arranged with nanoscale accuracy allowing to assemble multiple fluorophores without dye−dye aggregation. Aiming to develop a bright and sensitive ratiometric sensor system, we systematically studied the optical properties of nanoarrays of dyes built on DNA Origami platforms using a DNA template that provides a high versatility of label choice at minimum cost. The dyes are arranged at distances, at which they efficiently interact by Förster resonance energy transfer (FRET). To optimize array brightness, the FRET efficiencies between the donor fluorescein (FAM) and the acceptor cyanine 3 were determined for different sizes of the array and for different arrangements of the dye molecules within the array. By utilizing nanoarrays providing optimum FRET efficiency and brightness, we subsequently designed a ratiometric pH nanosensor using coumarin 343 as a pH-inert FRET donor and FAM as a pHresponsive acceptor. Our results indicate that the sensitivity of a ratiometric sensor can be improved simply by arranging the dyes into a well-defined array. The dyes used here can be easily replaced by other analyte-responsive dyes, demonstrating the huge potential of DNA nanotechnology for light harvesting, signal enhancement, and sensing schemes in life sciences.
X-ray imaging techniques have an enormous potential to understand the microstructure, its evolution, and its link to mechanical, thermal, and transport properties. In this lecture we report the use of a powerful, yet not so wide-spread, set of X-ray techniques based on refraction effects. X-ray refraction allows determining the internal specific surface of materials (surface per unit volume) in a non-destructive fashion, position and orientation sensitive, and with a nanometric detectability. We demonstrate showcases of ceramics and composite materials, where microstructural parameters could be achieved in a way unrivalled even by high-resolution techniques such as electron microscopy or computed tomography. We present in situ analysis of the damage evolution during tensile load and the identification of void formation in parts produced by selective laser melting.
The quest for the mixed inks
(2018)
In this article, we would like to share our observations concerning the inks produced by intentionally mixing soot or charcoal with tannin extracts or iron-gall ink. Aside from Zerdoun’s mention in her outstanding review of written sources, “Les encres noires au Moyen-Âge”, this ink category has received little if any attention from scholars and scientists. And yet, if analytically attested, the use of such inks could serve as an additional category to classify and distinguish the writing inks on the historical socio-geographic map of the writing inks we are trying to build.
Hepcidin-25 was identified as the main iron regulator in the human body, and it by binds to the sole iron-exporter ferroportin. Studies showed that the N-terminus of hepcidin is responsible for this interaction, the same N-terminus that encompasses a small copper(II)-binding site known as the ATCUN (amino-terminal Cu(II)- and Ni(II)-binding) motif. Interestingly, this copper-binding property is largely ignored in most papers dealing with hepcidin-25. In this context, detailed investigations of the complex formed between hepcidin-25 and copper could reveal insight into its biological role. The present work focuses on metal-bound hepcidin-25 that can be considered the biologically active form. The first part is devoted to the reversed-phase chromatographic separation of copper-bound and copper-free hepcidin-25 achieved by applying basic mobile phases containing 0.1% ammonia. Further, mass spectrometry (tandem mass spectrometry (MS/MS), high-resolution mass spectrometry HRMS)) and nuclear magnetic resonance (NMR) spectroscopy were employed to characterize the copper-peptide. Lastly, a three-dimensional (3D)model of hepcidin-25with bound copper(II) is presented. The identification of metal complexes and potential isoforms and isomers, from which the latter usually are left undetected by mass spectrometry, led to the conclusion that complementary analytical methods are needed to characterize a peptide calibrant or reference material comprehensively. Quantitative nuclear magnetic resonance (qNMR), inductively-coupled plasma mass spectrometry (ICP-MS), ion-mobility spectrometry (IMS) and chiral amino acid analysis (AAA) should be considered among others.
This chapter gives an overview about polymer optical fiber (POF) sensors with the focus on structural and civil engineering applications. POF properties such as the high-strain range, the low Young’s modulus, and specific scattering effects open new fields for fiber-optic sensing applications. POF properties, sensitivities, and cross-sensitivities that are relevant for sensing are introduced. Advantages and limitations are discussed. State-of-the-art POF sensors and application examples are presented in subsections with regard to their underlying measurement principles.
The test material EDS-TM001 together with an accompanying software package, “EDX spectrometer check”, have been made available in 2009 by BAM to be employed by EDS (energy dispersive spectrometer) users to check the performance of an EDS attached to the SEM. Particularly for test laboratories operating under accreditation schemes like ISO/IEC 17025, a periodical control of the critical instrumental parameters in end-user laboratories is required. With EDS-TM001 or EDS-TM002 (second generation) test material, this periodical check is simplified to the acquisition of only one 10 kV spectrum. The software “EDX spectrometer check” is destined to evaluate automatically this spectrum and determine the performance of the EDS in terms of energy resolution and calibration as well as possible alteration of low-energy efficiency due to detector contamination. Energy resolution can be compared with the specified values according to the international ISO standard ISO 15632:2012. EDS-TM is a synthetic material consisting of a thick layer of C, Al, Mn, Cu and Zr in a well-defined composition, deposited on a steel (in case of EDS-TM001) or silicon (in case of EDS-TM002) substrate. Meanwhile, more than one hundred laboratories use the EDS-TM001 or EDS-TM002 test material for the periodical check of their EDS. A detailed description of the test material and software together with examples of application was published recently. New results and gained experiences will be presented as well.
When the FWHM of lines appearing in the EDS-TM spectrum are determined, the spectrum background must be subtracted accurately. The applied physical background subtraction procedure is robust and takes into account the transmission of the detector window. While the previous version considers only Moxtek AP windows, the new version includes selection of silicon nitride window and the case of windowless detector. Moreover, the new version allows importing of spectra in Bruker spx format and EMSA/MSA files from EDAX TEAM software.
Extraction of true, 3D shape (and size) of non-spherical nanoparticles (NPs) is associated with errors by conventional 2D electron microscopy using projection images. Significant efforts within the ISO technical committee TC 229 ‘Nanotechnologies’ are aimed at establishing accurate TEM and SEM measurement of NP size and shape as robust, standard procedures. Study groups have been organizing inter-laboratory comparisons on well-selected NP systems according to the market needs, such as aggregated titania nano-powder for which size and shape distribution of primary crystallites of irregular shape must be measured accurately. To be noticed is e. g. the fact that the measurement procedure allows only manual selection of the particles clearly distinguishable for analysis as well as manual definition of the contour of the imaged NPs.
An inter-laboratory exercise on titania NPs (pure anatase, grown by hydrothermal synthesis) of well-defined non-spherical shape, i.e. bipyramidal has been recently started within ISO/TC 229 under similar conditions as for the irregular shaped titania. Overlapped particles were allowed to be considered, as long as they are clearly distinguishable. One decisive NP selection criterion was to analyze only those NPs with a roundness value below 0.7, i.e. the NPs laying on the support foil and, hence, with projection areas clearly deviating from perfect circles (R=1). The overall evaluation (for 15 labs) of the size descriptors (area, Feret, minFeret, perimeter) and shape descriptors (aspect ratio, roundness, compactness, extent) by analysis of variance is just to be finished and included in ISO/WD 21363 Nanotechnologies -- Protocol for particle size distribution by transmission electron microscopy.
This study demonstrates the bottom-up synthesis of
silver nanolenses.Arobust coating protocol enabled the
functionalization of differently sized silver nanoparticles with
DNAsingle strands of orthogonal sequence.Coated particles
10 nm, 20 nm, and 60 nm in diameter were self-assembled by
DNAorigami scaffolds to form silver nanolenses.Single
molecules of the protein streptavidin were selectively placed in
the gap of highest electric field enhancement. Streptavidin
labelled with alkyne groups served as model analyte in surface-
enhanced Raman scattering (SERS) experiments.Bycorre-
lated Raman mapping and atomic force microscopy, SERS
signals of the alkyne labels of asingle streptavidin molecule,
from asingle silver nanolens,were detected. The discrete,self-
similar aggregates of solid silver nanoparticles are promising
for plasmonic applications.
The physico-chemical basis of DNA radiosensitization: Implications for cancer radiation therapy
(2018)
High-energy radiation is used in combination with radiosensitizing therapeutics to treat cancer. The most common radiosensitizers are halogenatednucleo-sides and cisplatin derivatives, and recently also metal nanoparticles have been suggested as potentialradiosensitizing agents. The radiosensitizingaction of these compounds can at least partly be ascribed to an enhancedreactivity towards secondary low-energy electrons generated along the radiation track of the high-energyprimary radiation, or to an additional emission of secondary reactive electrons close to the tumor tissue. This is referred to as physico-chem ical radiosensitization. In this Conceptarticle we presentcurrent experimental methodsused to study fundamentalprocesses of physico-chemical radiosensitization and discuss the most relevant classes of radiosensitizers. Open questions in the current discussions are identified and future directions outlined, which can lead to optimized treatment protocols or even novel therapeuticconcepts.
This paper reports the outcome of an interdisciplinary team’s application of multispectral imaging techniques and material analysis to a music fragment from the first decades of the fifteenth century: Atri, Archivio Capitolare, Museo della Basilica Cattedrale, Biblioteca del Capitolo della Cattedrale, Frammento 17. This important parchment leaf has rarely been investigated since its discovery 45 years ago. Thanks to the applied techniques and methods (such as the evaluation of the data using the fingerprint model), it is now possible to discuss new evidence supporting conclusions regarding the fragment’s origin and afterlife.
The non-destructive assessment of cracks in concrete is a common task for which non-destructive evaluation solutions have been published. Primarily, these tests have been carried out on artificial cracks that have been created by using notches instead of natural cracks. This study evaluates a procedure designed to create reproducible and controlled cracks in concrete. The procedure is based on using expanding mortar in a series of blind holes. This is done in combination with carefully aligned reinforcement to guide the direction of the crack development. The depth of the crack is also controlled by reinforcement. Crack depth varies statistically in the range of the Maximum aggregate size (16 mm) used for concrete.
A method is described for high-resolution label-free molecular imaging of human bone tissue. To preserve the lipid content and the heterogeneous structure of osseous tissue, 4 μm thick human bone sections were prepared via cryoembedding and tape-assisted cryosectioning, circumventing the application of organic solvents and a decalcification step. A protocol for comparative mass spectrometry imaging (MSI) on the same section was established for initial analysis with time-of-flight secondary ion mass spectrometry (TOF-SIMS) at a lateral resolution of 10 μm to <500 nm, followed by atmospheric pressure scanning microprobe matrix-assisted laser desorption/ionization (AP-SMALDI) Orbitrap MSI at a lateral resolution of 10 μm. This procedure ultimately enabled MSI of lipids, providing the lateral localization of major lipid classes such as glycero-, glycerophospho-, and sphingolipids. Additionally, the applicability of the recently emerged Orbitrap-TOF-SIMS hybrid system was exemplarily examined and compared to the before-mentioned MSI methods.
This application note presents how EnviroESCA can be used to analyze E. coli biofilms on silicon under near ambient pressure conditions in various states of hydration. Such investigations of the outer bacterial cell surface in their hydrated state are essential for studying biological interfaces at work.
INTRODUCTION: X-ray photoelectron spectroscopy (XPS) provides elemental and chemical information from the outermost ~10 nm of the sample surface. This is in the same order of magnitude as the thickness of the outer bacterial membrane of gram-negative bacteria, as well as outer membrane molecules as exopolysaccharides and lipopolysaccharides, commonly attached to the cell surface. With the development of near-ambient pressure (NAP)-XPS, bacteria can be analysed with minimal sample preparation. This is in contrast to ultra-high vacuum XPS, where complex sample preparation including freeze-drying or fast-freezing is required, a treatment that may introduce artefacts or degrade the biological constituents.
METHODS: EnviroESCA is a laboratory based NAP-XPS instrument, equipped with a monochromated Al Kα radiation source and a differentially pumped energy analyser connected to an exchangeable sample environment, a basic build-up is displayed in Figure 1c. It allows for measurements in various gas-atmospheres, including water vapor, which makes it possible to characterise bacteria and other biological samples close to their natural, hydrated state. Artificial model-biofilms of exopolysaccharides, planktonic Pseudomonas Fluorescens and biofilms of Escherichia Coli have been characterised in hydrated and dried state.
RESULTS: High-resolution XPS-spectra from carbon, oxygen, nitrogen and phosphorous can be assigned to carbohydrates, lipids and proteins in general agreement with litterature2,3. Especially the carbon 1s peak is of interest (see Figure 1a and b), which reveal components originating from aliphatic carbon, single bounded carbon and double bounded/acetal carbon. A series of measurements of an E. coli biofilm from 11 mbar in humid environment to 1 mbar air reveal changes in the C1s peak, which suggests that the bacterial surface undergo substantial change.
DISCUSSION & CONCLUSIONS:
Bacterial samples can be analysed under near-ambient pressure conditions in various states of hydration with minimal sample preparation. Such investigations of bacterial cell wall surfaces are essential for studying biological interfaces at work.
Digital transformation and especially the dramatic rise of products and services connected to the Internet of Things raise the questions on how to deal with the increasing risks related to Privacy and Cybersecurity. Presumably, these risks seem to be insufficiently reflected in the European Union’s current regulative system – by being neither part of the traditional definition of a safe product nor part of product-specific vertical or horizontal directives. Certification based on standards as underlying requirements has been identified by policymakers as an instrument to address this issue. The latest European draft regulation aims at increasing security and trust in ICT products and services, and reducing current European market fragmentation with a new Cybersecurity Certification Framework. Based on the results of a qualitative analysis of stakeholder statements on the current proposal on the Cybersecurity Act, this paper discusses elements of the proposed Cybersecurity Certification Framework. As a theoretical background, this paper provides definitions of the terms Safety, IT-security, and Cybersecurity, presents selected Cybersecurity-related standards and provides an outlook on future challenges to Conformity Assessment in the digital transformation.
Digital transformation and especially the dramatic rise of products and services connected to the Internet of Things raise the questions on how to deal with the increasing risks related to Privacy and Cybersecurity. Presumably, these risks seem to be insufficiently reflected in the European Union’s current regulative system – by being neither part of the traditional definition of a safe product nor part of product-specific vertical or horizontal directives. Certification based on standards as underlying requirements has been identified by policymakers as an instrument to address this issue. The latest European draft regulation aims at increasing security and trust in ICT products and services, and reducing current European market fragmentation with a new Cybersecurity Certification Framework. Based on the results of a qualitative analysis of stakeholder statements on the current proposal on the Cybersecurity Act, this paper discusses elements of the proposed Cybersecurity Certification Framework. As a theoretical background, this paper provides definitions of the terms Safety, IT-security, and Cybersecurity, presents selected Cybersecurity-related standards and provides an outlook on future challenges to Conformity Assessment in the digital transformation.
The antimicrobial photodynamic approach has been demonstrated as an efficient and sustainable process for the eradication of microbial pathogens. In this work, silica-coated Magnetite nanoparticles (NPs) were used as carriers of glycosylated porphyrins and phthalocyanines. Their subsequent cationization
resulted in the production of stable antimicrobial photosensitizing materials, effective against E. coli. Suspensions of the photocatalysts in water present bimodal size distributions formed by big clusters and small NPs with hydrodynamic diameters between 8 and 38 nm. The presence of small NPs in the suspensions is related to an effective photodynamic inactivation (PDI) of E. coli cells. Glycosylation of the PS showed a positive effect on the PDI performance, which could be related to a higher accumulation of the photocatalyst over the bacterial cell membrane. In addition, these biocidal agents proved to be photostable and their photoactive performance decreased only between 23% and 28% upon 5 PDI cycles, mostly because of the loss of material between cycles, which makes them promising materials for water disinfection purposes.
Studies on the mechanochemical Knoevenagel condensation of fluorinated benzaldehyde derivates
(2018)
The mechanochemical Knoevenagel condensation of three fluorinated benzaldehyde derivates and malononitrile was investigated. The reactions were performed under solvent- and catalyst-free conditions and resulted in highly crystalline products after crystallization from a viscous phase in the milling jar.
The quality of the obtained crystals was sufficient for single-crystal X-ray diffraction circumventing a recrystallization step. To gain more information on the reaction, progress was investigated in situ using time-resolved Raman spectroscopy. The results show a direct conversion of the reactants.
Anewbariumcoordination polymer, BaF-benzenedicarboxylate (BaF(p-BDC)0.5), with fluorine directly coordinated to the metal cation, was prepared by mechanochemical synthesis routes. Phase-pure BaF-benzenedicarboxylate was synthesized by milling starting either from barium hydroxide or from Barium acetate as sources for barium cations. In both cases, the second reactant was 1,4-benzenedicarboxylic acid (H2(p-BDC)). Ammonium fluoride was used as fluorinating agent directly at milling. This is the first mechanochemical synthesis of coordination polymers where fluorine is directly coordinated to the metal cation.
Following the second possibility, barium acetate fluoride (Ba(OAc)F) is formed as ntermediate product after milling, and the new coordination polymer is accessible only after washing with water and dimethyl sulfoxide. The new compound BaF(p-BDC)0.5 was characterized by X-ray powder diffraction, FTIR-, and 19F, 1H-13C CP MAS NMR spectroscopies, DTA-TG, and elemental Analysis.
Two divalent manganese aminophosphonates, manganese mono (nitrilotrimethylphosphonate) (MnNP3) and manganese bis N-(carboxymethyl)iminodi(methylphosphonate)) (Mn(NP2AH)2), have been prepared by mechanochemical synthesis and characterized by powder X-ray diffraction (PXRD). The structure of the novel compound Mn(NP2AH)2 was determined from PXRD data. MnNP3 as well as Mn(NP2AH)2 exhibits a chain-like structure.
In both cases, the manganese atom is coordinated by six oxygen atoms in a distorted octahedron. The local coordination around Mn was further characterized by extended X-ray absorption fine structure. The synthesis process was followed in situ by synchrotron X-ray diffraction revealing a three-step reaction mechanism. The asprepared manganese(II) phosphonates were calcined on air.
All samples were successfully tested for their suitability as catalyst material in the oxygen evolution reaction.
Tandem MS techniques are widely used for both, structure and sequence elucidation of biopolymers. Thereby, fragmentation activation is realized by various methods, for example with lasers or collisions with neutral gases. In this study, we present a new Tandem MS System using a commercially available vacuum ultraviolet lamp. On the one hand, this approach provides efficient fragmentation in both ionization modes, positive as well as negative. On the other hand, it enables an additional previously not achieved post ionization of the fragments. While the first results in atypical fragment patterns and, thus provides orthogonal information, the second is crucial especially to identify low abundant ions.
The syntheses and crystal structures of two cerium(IV) phosphonates are presented. Cerium(IV) bis(phenylphosphonate) Ce(O3PC6H5)2 1 can be formed from precipitation and mechanochemical reaction, whereas cerium(IV) bis(carboxymethylphosphonate) monohydrate Ce(O3PCH2COOH)2 H2O 2 is only accessible via ball milling. All reactions proceed very fast and are completed within a short time span. In situ measurements for the syntheses of 1 show that the product occurs within seconds or a few minutes, respectively. The structures were solved from powder X-ray diffraction data.
Cyanide is known to be a very hazardous and toxic substance. Through the binding to cytochrome oxidase it inhibits the oxygen utilization in cells. The LD50 of cyanide is as low as 1.0 mg/kg. Therefore it is inalienable to develop sensing methods to detect cyanide with a very high selectivity and sensitivity.
In our group we developed a non-fluorescent monomer which is able to detect cyanide-anions with very high selectivity and sensitivity based on a “turn-on” fluorescence method. As cyanide-source we used tetrabutylammoniumcyanide (TBAC). Using an excitation wavelength of 600 nm the increase in fluorescence at 642 nm is strictly selective with cyanide-anions. Different anions like fluoride, hydroxide or acetate show no increase at all. With this new detection system, concentrations as low as 1.6 nM can be detected.