Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2018 (819) (entfernen)
Dokumenttyp
- Vortrag (342)
- Zeitschriftenartikel (221)
- Posterpräsentation (155)
- Beitrag zu einem Tagungsband (65)
- Sonstiges (16)
- Buchkapitel (8)
- Dissertation (4)
- Beitrag zu einem Sammelband (3)
- Forschungsbericht (3)
- Forschungsdatensatz (2)
Sprache
- Englisch (657)
- Deutsch (158)
- Spanisch (3)
- Französisch (1)
Schlagworte
- LIBS (40)
- Nanoparticles (36)
- Concrete (33)
- Fluorescence (27)
- Nanoparticle (25)
- XPS (21)
- Thermography (19)
- Mechanochemistry (18)
- Ultrasound (16)
- Laser ablation (15)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (270)
- 8 Zerstörungsfreie Prüfung (251)
- 6 Materialchemie (243)
- 6.1 Oberflächen- und Dünnschichtanalyse (97)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (81)
- 8.0 Abteilungsleitung und andere (77)
- 6.3 Strukturanalytik (73)
- 1.1 Anorganische Spurenanalytik (69)
- 4 Material und Umwelt (56)
- 8.4 Akustische und elektromagnetische Verfahren (49)
Eingeladener Vortrag
- nein (342)
Untersuchungen haben gezeigt, dass sich ältere Schafe gut als Modell für die mi-nimalinvasive Behandlung von Osteoporose eignen [1]. Um einen Behandlungs-effekt nachzuweisen, wird dabei unter anderem die Belastungsfähigkeit des Kno-chens durch Druckversuche an kleinen Zylindern aus den behandelten und unbe-handelten Knochen bestimmt. Diese hatten hier einen Durchmesser von 10 mm und eine Höhe von 13 mm. Für den in-situ Druckversuch wurde eine Deben CT5000 verwendet. In einer Serie von Druckerhöhungen wurden die Proben je-weils tomographiert. Dabei ergab sich zunächst, dass mit der µCT innerhalb der Knochen im oberen und unteren Bereich schon Brüche nachgewiesen werden können, obwohl die gemessene Kraftaufnahmekurve keine Unstetigkeit zeigt. Deswegen wurden die starren Probenaufnehmer der Deben Anordnung durch bewegliche Aufnehmer ergänzt, die eine leichte Verkippung der belasteten Ober-flächen ausgleichen können. Ein Vergleich der gemessenen und der aus den µCT-Daten berechneten Verschiebungsfelder ergab trotz der komplexen Struktur der Knochen gute Übereinstimmungen. Diese Verschiebungen wurden dann mit den aus den µCT Daten simulierten mechanischen Druckversuchen, Von-Mise-Spannungen und daraus berechneten Verschiebungen verglichen. (VGStudioMax Simulation).
The mechanism of action of zirconium permanent modifiers on graphite surfaces was investigated in order to understand its influence on the analytical signal in atomic and molecular absorption spectrometry (AAS/MAS). For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. We propose here a mechanism, where ZrO2 acts as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface. No evidence of the formation of zirconium carbide was found. Consequently, as the CaF formation is catalysed by a heterogeneous catalyst, surface modifications with ZrO2 nanoparticles and ZrO xerogels were investigated in order to increase the surface area. Their influence was evaluated in the molecule formation of CaF, CaCl, CaBr, and CaI. Graphite furnace modification with zirconium oxide nanoparticles proves to be the best choice for fluorine analysis with a signal enhancement of more than eleven times with respect a non-coated graphite furnace. However, the influence of zirconium modifications in the analytical signals of Cl, and I is lower than the F signals or even negative in case of the Br. Understanding zirconium modifiers as heterogeneous catalysts offers a new perspective to AAS and MAS, and reveals the potential of surface analytical methods for development of improved permanent modifiers and graphite furnace coatings.
Metallische Druckgefäße werden aus Gründen der Gewichtseinsparung zunehmend durch Composite-Druckgefäße ersetzt. Während der Alterungsprozess bei metallischen Druckgefäßen durch Wöhlerkurven hinreichend beschrieben wird, ist der Alterungsmechanismus bei Composite-Druckgefäßen noch nicht vollständig geklärt. Im Rahmen des BAM-interne Themenfeldprojekts COD-AGE werden mit diversen Verfahren alterungsbegleitende, zerstörungsfreie Prüfungen an Composite-Druckgefäßen durchgeführt. Nach einem kurzen Überblick über die BAM und den FB 8.4 werden zunächst die allgemeine Funktionsweise der Wirbelstromprüfung und die bildgebende Wirbelstromprüfung erklärt. Anschließend werden Ergebnisse der konventionellen und hochfrequenten Wirbelstromprüfung vorgestellt.
Der letzte Teil des Vortrages beschäftigt sich mit der Prüfbarkeit von Kunststoffen aus Kunstharz und 3D-Druck mit dem Wirbelstromverfahren durch Zugabe ferromagnetischer Nanopartikel bzw. Verwendung von ferromagnetischem Filament.
Metallische Druckgefäße werden aus Gründen der Gewichtseinsparung zunehmend durch Composite-Druckgefäße ersetzt. Während der Alterungsprozess bei metallischen Druckgefäßen durch Wöhlerkurven hinreichend beschrieben wird, ist der Alterungsmechanismus bei Composite-Druckgefäßen noch nicht vollständig geklärt. Im Rahmen des BAM-interne Themenfeldprojekts COD-AGE werden mit diversen Verfahren alterungsbegleitende, zerstörungsfreie Prüfungen an Composite-Druckgefäßen durchgeführt. Im ersten Teil dieses Vortrages werden Ergebnisse der konventionellen und hochfrequenten Wirbelstromprüfung vorgestellt.
Der zweite Teil des Vortrages beschäftigt sich mit der Prüfbarkeit von Kunststoffen aus Kunstharz und 3D-Druck mit dem Wirbelstromverfahren durch Zugabe ferromagnetischer Nanopartikel bzw. Verwendung von ferromagnetischem Filament.
Da derzeit keine zerstörungsfreie Alternative zur Lokalisierung von Leitungswasserschäden in Fußböden existiert, werden in der Regel unter hohem zeitlichen und finanziellen Aufwand Sondierungsbohrungen vorgenommen, um das entnommene Material im Labor thermo-gravimetrisch zu untersuchen. Dabei nehmen Leitungswasserschäden mit rd. 2,6 Milliarden Euro jährlich den deutlich größten Posten bei Gebäudeversicherungen ein. Für derartige Fragestellungen werden seit einigen Jahren Neutronensonden eingesetzt. Mit diesem Verfahren ist es möglich, sich einen Überblick über die Gesamtwassermenge in einem definierten Baustoffvolumen zu verschaffen, jedoch kann flüssiges und chemisch gebundenes Wasser nicht unterschieden werden. Daher werden die Messdaten mit den Ergebnissen der Sondierungsbohrungen kalibriert. So können auch große Flächen wie Industriefußböden in relativ kurzer Zeit größtenteils zerstörungsfrei untersucht werden. Da die integrale Messweise der Neutronensonde allerdings keine Tiefenzuordnung eines gefundenen Feuchteschadens zulässt, muss auch diese Information über die Bohrkerne generiert werden. Die Idee des Projekts ist, durch den parallelen Einsatz des Radarverfahrens in Zukunft auf Sondierungsbohrungen verzichten zu können. Nach der Abgrenzung trockener von feuchten Bereichen über die Neutronensonde, wird das Radarverfahren herangezogen, um typische Schadensfälle zerstörungsfrei zu unterscheiden. In systematischen Laborstudien an modular aufgebauten Referenzprobekörpern untersuchen wir die Nachweisgrenzen und Detektionswahrscheinlichkeiten der beiden Verfahren für verschiedene, häufig anzutreffende Fußbodenaufbauten. Anschließend sollen über Datenfusion und Signalverarbeitung innovative Auswertungsansätze entwickelt werden, welche die Messergebnisse von Neutronensonde und Radar automatisiert zur Gewinnung eines höheren Informationsgehalts und zur Klassifizierung der Schadensfälle kombinieren. Im Rahmen des Projekts wird die erarbeitete Vorgehensweise an real geschädigten Objekten getestet, um die Methode zu etablieren sowie Akzeptanz bei Anwendern und Eigentümern zu schaffen. Könnten durch genauere Schadenseingrenzung die Sanierungskosten um nur 4% gesenkt werden, ergäbe sich in Deutschland eine Kostenreduzierung von ca. 100 Million Euro jährlich.
Nuklear magnetische Resonanz (NMR) etabliert sich zunehmend im Bauingenieurwesen als eine alternative Methode zur zerstörungsfreien Feuchtebestimmung in Baustoffen. Schäden, die durch einen zu hohen Anteil an Flüssigwasser auftreten können, sind Ablösungen, Korrosion, Frostschäden, Induktion von Salzkristallisationen, etc. Aufgrund der Sensitivität für 1H-Protonen, ist NMR eine geeignete Methode zur Feuchtedetektion. Dabei kann laut Theorie zwischen frei, chemisch oder physikalisch gebundenem Wasser differenziert werden, während in der Praxis abhängig von der Messtechnik und Probengröße größtenteils nur das freie Wasser detektierbar ist. Mithilfe der NMR Relaxometrie lassen sich nicht nur Relaxationsabklingkurven ermitteln, sondern auch Relaxationszeitenverteilungen, sowie bei Vollsättigung ggf. eine Porengrößenverteilung ableiten. Darüber hinaus lassen sich erste Annahmen über die Entwicklung der Porensättigung bei Teilsättigung der Probe treffen.
Ziel dieser Arbeit war die Untersuchung der zeitlichen Entwicklung der Porensättigung während des natürlichen Trocknungsprozesses (Teilsättigung) sowie die Ermittlung der Porengrößenverteilung an Beispiel von zementgebundenen Estrichen. Für den Versuch wurden zwei zementgebundene Estrichproben nach abgeschlossener Hydratation wieder aufgesättigt. Während des anschließenden natürlichen Trocknungsprozesses wurden regelmäßig NMR-Messungen durchgeführt sowie die Massenentwicklung observiert. Hauptfokus lag auf der zeitlichen und tiefenabhängigen Entwicklung der Relaxationszeitenverteilungen. Bei fortschreitender Trocknung der Proben konnte eine Verschiebung des Maximums der Relaxationszeitenverteilung zu kleineren Zeiten beobachtet werden. Die Ursache liegt zum einen in dem abnehmenden Anteil an freiem Wasser in größeren Poren und zum anderen in dem verhältnismäßig zunehmenden Signalanteil durch Wasser in kleineren Poren.
Durch den Vergleich mit Quecksilberporosimetrie und Gas-Adsorptions-Ergebnissen, konnte aus den NMR-Daten eine unimodale Porengrößenverteilung mit einer dominanten Porengröße von 0,08 bis 0,1 µm und eine effektive Oberflächenrelaxivität von ca. 10 bis 30 µm/s abgeleitet werden.
Mit additiven Fertigungsverfahren hergestellte Bauteile und Produkte aus Kunststoffen werden zunehmend nicht mehr nur als Prototypen, sondern als voll funktionsfähige Bauteile und Produkte gefertigt. Bedingt durch die Fertigungsprozesse und den schichtweisen Aufbau resultieren physikalische Materialeigenschaften, die stark von den Fertigungsparametern abhängen und zudem anisotrop sind. Von den Fertigungsparametern werden auch die Oberflächeneigenschaften beeinflusst, sodass zu erwarten ist, dass sich die Beständigkeit gegenüber äußeren Umwelteinflüssen bei additiv gefertigten Bauteilen von der konventionell gefertigter unterscheiden kann. Nachfolgend wird daher die Entwicklung eines Qualitätssicherungskonzeptes basierend auf spektroskopischen und zerstörungsfreien Prüfverfahren vorgestellt, in dem der Alterungsprozess von mittels Fused Deposition Modelling (FDM) und mittels Lasersintering (LS) hergestellten Probekörpern untersucht wird.
Mit additiven Fertigungsverfahren hergestellte Bauteile und Produkte aus Kunststoffen werden zunehmend nicht mehr nur als Prototypen, sondern als voll funktionsfähige Bauteile und Produkte gefertigt. Bedingt durch die Fertigungsprozesse und den schichtweisen Aufbau resultieren physikalische Materialeigenschaften, die stark von den Fertigungsparametern abhängen und zudem anisotrop sind. Von den Fertigungsparametern werden auch die Oberflächeneigenschaften beeinflusst, sodass zu erwarten ist, dass sich die Beständigkeit gegenüber äußeren Umwelteinflüssen bei additiv gefertigten Bauteilen von der konventionell gefertigter unterscheiden kann. Nachfolgend wird daher die Entwicklung eines Qualitätssicherungskonzeptes basierend auf spektroskopischen und zerstörungsfreien Prüfverfahren vorgestellt, in dem der Alterungsprozess von mittels Fused Deposition Modelling (FDM) und mittels Lasersintering (LS) hergestellten Probekörpern untersucht wird.
This application note presents how EnviroESCA can be used to analyze bacterial samples under near ambient pressure conditions in various states of hydration using different levels of humidity. Such investigations of bacterial cell wall surfaces in their hydrated state are essential for studying biological interfaces at work.
The use of innovative near-ambient pressure (NAP-)XPS instrumentation allows the detailed analysis of irregularly-surfaced biofilms. NAP-XPS enables the surface analysis of bacterial samples in their natural hydrated state without complex sample preparation techniques such as freeze-drying or fast-freezing, which are needed for XPS analysis in ultrahigh vacuum.
XAFS@BAMline
(2018)
X-ray Absorption fine structure spectroscopy (XAFS) is a frequently employed technique in order to investigate structural composition and Change of chemical compounds such as catalytic species or corrosion processes. These structural properties are essential (i) to understand underlying reaction mechanism and (ii) to further improve the design of materials.
While XAFS measurements are usually performed with ionization Chambers or simple fluorescence detectors, we at BAMline specialize in measurements with innovative set-ups that meet Specialrequirements such as time resolution, (3D-) spatial Resolution or demanding sample environments.
This contribution presents various available XAFS configurations with their corresponding applications. In particular, these comprise single -shot XAFS for time- resolved measurements, grazing-exit XAFS with energy and a spatially resolved detector for the characterization of thin films and an in situ grazing incidence Setup for the characterization of corrosion layers.
Additionally,the possibility of analyzing Minute samples in total-reflection geometry is demonstrated.
For the first time, X-ray refraction techniques are proven for the identification of void formation in Ti-6Al-4V parts produced by selective laser melting. The topology and volume fraction of pores are measured in samples produced with different laser energy density. Unique X-ray refraction methods identify different kinds of defects, characteristic to the regions below and above the Optimum laser energy density, namely unprocessed powder (unmolten powder particles, balling effect, and Fusion defects) from empty keyhole pores. Furthermore, it is possible to detect small inhomogeneities (voids or cracks) with sizes below the spatial resolution of optical microscopy and X-ray computed tomography.
Heterogeneous catalysis is a key technology in modern industrial societies. The main steps of a catalytic process take place at the surfaces of complex materials. For the investigations of these surfaces X-ray photoelectron spectroscopy is widely used and fits ideally. At some suitable examples, it will be explained how XPS can help to understand such catalysts better. The focus is on selective oxidation catalysts, one of the main challenges of present research. Here it will illustrate, how changes in the near surface region influence the catalyst performance and, herewith the different stages (activation, maximum performance and deactivation) in the life of catalysts. Additionally, it will be stressed out how important information at different depth regions (surface, near-surface region, bulk) can be useful for comprehensive understanding of the material.
Another important subject is nanostructured catalysts with molecular sieves as supports or defined complexes as precursors. Finally, the combination of XPS with other methods used in the analysis of catalysts, e.g. electron microscopy, X-ray absorption spectroscopy and low energy ion scattering will be discussed.
This study focuses on the analysis of a corpus of manuscripts found in Fustat (medieval Cairo, Egypt) in the biggest medieval “archive” found until now: the Cairo Geniza. The giant collection of mostly Jewish documents has been attracting scholars’ attention a lot but so far, the material aspects of these documents seem to have been mainly neglected.
Application of scientific methods of analysis, especially X-Ray fluorescence characterization, contributes to our understanding of the materials used for production of manuscripts during the Middle ages.
Our corpus of the 11th century manuscripts comprises manuscripts written by scribes belonging to three Jewish communities that co-existed in Cairo during this period: the Karaites, the so-called Jerusalemites (or Palestinian) and the so-called Babylonians (or Iraqi), three different communities with different traditions and different leaders. The differences manifest themselves also in the paleographical properties of the manuscripts produced within each community. Can we extend the differences detected by the paleographical analysis to differences in composition of the writing materials and especially the composition of the inks? Or can we relate the differences in the composition to the manuscript type (legal, private...), or to another criterion. In this presentation, we offer answers to some of the questions using statistical analysis of the measurements results.
Mit Hilfe der Computertomographie können zerstörungsfrei Bilder des Bodengefüges gewonnen werden. Sowohl die verschiedene Dichte des Bodens als auch Hohlräume und Poren sowie Wurzeln und anderes organisches Material können dargestellt werden. Die Wurzeln werden dabei lagerichtig wiedergegeben. Begrenzt wird dieses durch die Ortsauflösung des jeweiligen Tomogramms.
Ist die Methode für eine Fragestellung aus der landwirtschaftlichen Praxis – Einfluss der Bodenbearbeitung auf das Wurzelbild von Raps – geeignet?
This study focuses on the analysis of a corpus of manuscripts found in Fustat (medieval Cairo, Egypt) in the biggest medieval “archive” found until now: the Cairo Geniza. The giant collection of mostly Jewish documents has been attracting scholars’ attention a lot but so far, the material aspects of these documents seem to have been mainly neglected.
Application of scientific methods of analysis, especially X-Ray fluorescence characterization, contributes to our understanding of the materials used for production of manuscripts during the Middle ages.
Our corpus of the 11th century manuscripts comprises manuscripts written by scribes belonging to three Jewish communities that co-existed in Cairo during this period: the Karaites, the so-called Jerusalemites (or Palestinian) and the so-called Babylonians (or Iraqi), three different communities with different traditions and different leaders. The differences manifest themselves also in the paleographical properties of the manuscripts produced within each community. Can we extend the differences detected by the paleographical analysis to differences in composition of the writing materials and especially the composition of the inks? Or can we relate the differences in the composition to the manuscript type (legal, private...), or to another criterion. In this presentation, we offer answers to some of the questions using statistical analysis of the measurements results.
qNMR provides the most universally applicable form of direct concentration or purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The workshop presents basic terms of statistics and uncertainty analysis, which are the basis for qNMR spectroscopy and data analysis such as, e.g., standard deviations, linear regression, significance tests, etc. and gives typical examples of applications in qNMR spectroscopy.
The paper addresses “WHITE LIGHT INTERFERENCE MICROSCOPY, ELLIPSOMETRY, AND INSTRUMENTED INDENTATION TESTING AS REFERENCE PROCEDURES“ and is subdivided in the following sections: 1. Measurement vs. testing vs. reference procedures, 2. White light interference microscopy (WLIM) for determination of step height h, 3. Spectroscopic ellipsometry (SE) for determination of layer thickness d and 4. Instrumented indentation testing (IIT) for determination of indentation hardness HIT. The following points are discussed in more detail: methodology of measurement and testing, uncertainty budgets for direct (WLIM), model-based (SE) and formula-based (IIT) reference procedures by means of specific examples. It is shown that standardization efforts are connected to reference procedures.
An artificial digestion of silver nitrate is reported. It is shown that AgSCN nanoparticles emerge from ionic silver in saliva and remain present during the entire digestion process. The particles were characterized by infrared spectroscopy and small- and wide-angle X-ray scattering (SAXS/WAXS) regarding their composition and size distribution.
Mit Laserlicht kann man eine Materialoberfläche berührungslos und schnell moduliert aufheizen. Dabei entsteht eine stark gedämpfte Wärmewelle, die tief ins Material eindringen kann. Erzeugt und überlagert man solche thermischen Wellen auf kohärente Weise, dann kann man damit versteckte Materialfehler zerstörungsfrei und sehr präzise aufspüren. Sogar eine bildgebende Tomografie ist denkbar.
Der Vortrag zeigt zwei Möglichkeiten zur Verbesserung der VSSA-Screening-Methode zur Identifizierung von Nanopulvern auf. Bisher ist das Verfahren nur für monodisperse Partikel mit idealer Kugelform valide. Die Verteilungsbreite der Partikelgröße soll durch die Nutzung des Modells einer logarithmischen Normalverteilung implementiert werden. Die Abweichung der gemessenen Partikel von einer idealen Kugel in Sphärizität, Rundheit und Rauigkeit sind über einen Morphologiefaktor MF zu berücksichtigen. An einem konkreten Beispiel werden Auswirkungen der Implementierungen rechnerisch dargestellt und mit dem bisherigen Verfahren verglichen.
In addition to previously reported results on the simulated aging of polystyrene samples (PS) containing 1 wt. % hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene (PP)-samples containing 0.1 wt. % BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006.For the determination of BDE-209 in the collected rain water samples derived from the used climate chamber, the samples were prepared in accordance with a validated protocol. Before the analyses, each sample was spiked with 2 µL of isotopically labeled BDE-209 (13C10-BDE-209) to serve as internal standard (ISTD) in the performed stable isotope dilution analysis. Subsequently the samples were extracted with isooctane, the obtained aliquots of the extracts were concentrated to 200 µL and 2 µL of the resulting solution were injected to the GC/MS for quantification.
Additionally, the total bromine contents are monitored for the aged and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) as well as X-ray fluorescence analysis (XRF) as non-destructive and rapid method. Furthermore, results from surface analysis using environmental scanning electron microscopy (ESEM) for morphological characterization of the aged and untreated samples were presented and discussed. In general, the resulting data from the accelerated aging will be compared to those from the natural weathering experiments (“atmospheric exposure”, in soil).
The atmospheric exposure was performed by placing the samples on a weathering rack, which is aligned in SW direction (in a 45° angle to the horizon). The weathering data were regularly recorded by Deutscher Wetterdienst at this site. The surfaces of the test specimens (aged and stored references) were analyzed by ESEM as well as by LA-ICP-MS and by XRF. The surface of PS and PP specimens aged outdoors present the aging under real conditions and allow the comparison to the accelerated aged specimens by means of the weathering chamber. This way, we explore the efficiency of the accelerated aging procedure, which provides the advantage of well-defined and reproducible conditions compared to natural weathering, as a tool for testing different plastic materials.
Additionally “in soil” experiments were conducted in-door in a well characterized testing soil. The soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining concrete basin inside of an air-conditioned room. In this manner, TOC, water capacity and humidity are recorded parameters. To assure a washing out process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. The water content is additionally monitored by weight of the basin, capturing water from raining periods. The correct humidity is a fundamental parameter for biological activity. Samples of PS resp. PP were of dimension 10x1cm and 5 specimens were placed up to the half in the soil per basin. Microbial activity of the soil, monitored by the reference polyurethane, sets HBCD resp. BDE-209 of the samples free and will be leached from the samples by raining water. Thereafter these will be captured by passive samplers placed in a distinct distance to the samples in the soil. The “in soil” experiments are complementary to the weathering experiments due to the biological activity in the soil. These experiments simulate the fate of the brominated flame retardants in the biosphere.
Die ehemals wegen komplexer Technik und vergleichsweise hohen Wartungskosten beim Anwender ungeliebte Prozessanalysentechnik (PAT) erfährt sich mittlerweile immer mehr als etablierender Bereich mit einem großen Zuwachs und Dynamik. Die Prozesskontrolle und -steuerung über physikalische Kenngrößen wie Druck und Temperatur lässt eine weitere Optimierung der Anlagen kaum mehr zu. Nur mittels stoffspezifischer Analysen lassen sich Rohstoffschwankungen, Ausbeuten und Energieeinsatz konsequent optimieren.
Der systematische Einsatz der Prozessanalysentechnik verändert Prozesse und Produktionsumgebungen und hat damit die Chance, Kernstück dezentral automatisierter Produktionseinheiten zu werden. Ein neuer Arbeitskreis der NAMUR AK 3.7 „Smarte Sensorik, Aktorik und Kommunikation“ wird diesem verstärkt Rechnung tragen. Es werden reale Anwendungsbeispiele aufgezeigt, die eine schnelle Amortisation von PAT im Prozess untermauern.
Angetrieben durch Digitalisierung und die sogenannte Industrie 4.0 steigt die Erwartungshaltung gegenüber der Nutzung von Sensorik. Die Unsicherheit, Widersprüchlichkeit und Redundanz separat verarbeiteter einzelner Quellen soll durch die synergetische Zusammenführung heterogener Datensätze überwunden werden. Dabei steht der zunehmenden Aufgabenkomplexität eine ebenso zunehmende Verfügbarkeit an Sensoren, Daten und Rechenleistung gegenüber.
Der Begriff Datenfusion fasst Ansätze zusammen, die Daten zu abstrakteren, aber besser verständlichen Informationen verarbeiten. Die Fusion ist Kernbestandteil effektiver Assistenzsysteme und beweist in vielzähligen Aufgaben - von militärischen Anwendungen über Flug- und Fahrassistenzsysteme, bis in den Heimbereich – ihr großes Potenzial. Durch die wachsende Automatisierung bei der Messdatenerfassung wird Datenfusion auch in der industriellen Qualitätsprüfung und –sicherung zunehmend attraktiver.
Der Vortrag gibt einen Überblick über den breiten Themenkomplex und widmet sich dabei speziell der Fragen, welche Informationen in multivariaten Datensätzen stecken und wie sie extrahiert werden können. Abschließend wird ein Beispiel für die erfolgreiche Anwendung zur zerstörungsfreien Prüfung von Betonbauteilen vorgestellt. Der systematische Vergleich von Algorithmen, die Charakteristika des Labordatensatzes in unterschiedlicher Weise adressieren erlaubt überraschende Schlussfolgerungen.
Gold ist eines der sieben schon im Altertum bekannten Metalle und wurde wg. seines Glanzes und seiner Seltenheit von alters her als Tauschmittel und zur Herstellung von Schmuck benutzt. Außerdem ist es einfach bearbeitbar und weitestgehend gegen chemische Einflüsse resistent. Die Untersuchungen von Gold mit synchrotronstrahlungsangeregter Röntgenfluoreszenzanalyse sind zerstörungsfrei und geben Auskunft über die in der untersuchten Probe vorhandenen chemischen Elemente. Bei den hier vorgestellten Untersuchungen an der BAMline stehen Fragestellungen wie Herkunft, Herstellungsverfahren und Zusammengehörigkeit von Goldfunden im Vordergrund. Die verschiedenen Fragestellungen werden an einer Reihe von Beispielen erläutert die vom Wikingerschatz aus Hiddensee über die Himmelsscheibe von Nebra bis hin zu Funden aus Ägypten langen. Zusätzlich werden die modernen Messmethoden vorgestellt, die am Synchrotron heutzutage zur Verfügung stehen.
We discuss the role of the volume specific surface area (VSSA) as determined from the specific surface area measured by the (extended) Brunauer-Emmett-Teller (BET) technique, in the identification process of powdered nano- and non-nanomaterials in line with the EU definition of nanomaterial. Results obtained in the NanoDefine project demonstrate that under appropriate conditions, VSSA can be used as proxy to the number-based particle size distribution. The extent of agreement between nano/non-nano classification by electron microscopy (EM) and classification by VSSA is investigated systematically on a large set of diverse particulate substances, representing most of the cases expected in regulatory practice. Thus, parameters such as particle shape, size polydispersity/multi-modality, and particle (inner or coating) porosity are evaluated. Based on these results, we derive a tiered screening strategy for powders, involving the use of VSSA for the purpose of implementing the definition of nanomaterial, and recommend it for inclusion in a technical guidance for the implementation of the definition.
A composite material is a combination of two or more materials with very different mechanical, thermal and electrical properties. The various forms of composite materials, due to their high material properties, are widely used as structural materials in the aviation, space, marine, automobile, and sports industries. However, some defects like voids, delamination, or inhomogeneous fiber distribution that form during the fabricating processes of composites can seriously affect the mechanical properties of the composite material. In this study, several imaging NDE techniques such as: thermography, high frequency eddy current, ultrasonic, x-ray radiography, x-ray laminography, and high resolution x-ray CT were conducted to characterize the microstructure of carbon fiber composites. Then, a 3D analysis was implemented by the destructive technique of serial sectioning for the same sample tested by the NDE methods. To better analyze the results of this work and extract a clear volume image for all features and defects contained in the composite material, an intensive comparison was conducted among hundreds of 3D-NDE and multi serial sections’ scan images showing the microstructure variation.
Fuel contamination of soils display complex and variable hydrocarbon mixtures with different volatility and toxicity characteristics. A recently suggested headspace procedure for the structure-based quantification of volatile hydrocarbons is evaluated regarding repeatability, reproducibility, and practical robustness. Three aliphatic and three aromatic fractions covering the boiling range between 69 and 216°C were defined as summation parameters by their respective equivalent carbon number ranges. A standard mixture of 35 aliphatic and aromatic hydrocarbons was used for calibration on basis of selected mass fragments specific for the aliphatics and aromatics, respectively. Two standard soils were fortified with the standard mixture or different fuels, respectively, and submitted to the analytical procedure. Limit of detection (LOD) and limit of quantification (LOQ) were for all fractions lower than 0.1 and 0.3 mg/kg, respectively. Analyte recovery was linear up to between 20 and 110 mg hydrocarbons/kg soil depending on the fraction. Hydrocarbon recovery ranged between 80% and 110% depending on the fraction and the repeatability was typically better than 10%. Finally, the impact of extraction solvent variation, column solid-phase polarity, and alternative summation of fractions were investigated. The procedure was applied to liner samples taken from a site contaminated with aviation fuel and its practicability is discussed.
Summary: A screening test for potential emissions of volatile organic compounds (VOC) was run on different thermoplastic filaments used for 3D printing. The method of direct thermal desorption was used to simulate the high temperatures during the 3D printing process and to identify the main compounds emitted from the filaments. A large number of unexpected compounds were detected that might affect the user’s health and have an impact on indoor air chemistry.
Introduction: The use of desktop 3D printers is increasing. Compared to other devices with known emissions, e.g. laser printers, there is still a lack of information on possible emissions of VOC and ultrafine particles during operation and the effect on indoor air quality. Most of the commercially available desktop 3D printers operate with a molten polymer deposition. For this process a solid thermoplastic filament is heated in an extrusion nozzle. Most filaments for desktop 3D printers use either acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) as filament. Alternatives are polyvinyl alcohol (PVA) or polycarbonate (PC).
Method: Eight different thermoplastic filaments for 3D printers were analysed by direct thermal desorption followed by GC-MS identification of the emitted substances. Direct thermal desorption was done by desorbing 5 mg of the feedstock for 1 minute at a temperature of 210°C. This is an average temperature for 3D printing with thermoplastic filaments.
Results and conclusions: The comparison of the 4 different filament groups showed the highest overall emissions from ABS, followed by PLA, PC and PVA. Filament ABS 2 emitted mainly SVOCs and triphenyl phosphate, the latter has the highest emission for a single compound from all evaluated filaments.
Thermoplastic filaments are a new source of VOC emissions due to the high temperatures associated with 3D printing, which can reach up to 270°C. Some of the detected compounds like lactic acid, lactide and bisphenol A have never been described before in the indoor environment. Additionally some of the main substances could not be identified and some others might have the potential to affect the indoor air chemistry.
The appearance of some newly detected compounds raises concerns about potential health effects for the users of 3D printers at home.
The KorroPad indicator test was invented at the Federal Institute for Materials Research and Testing to detect stainless-steel surfaces susceptible to pitting corrosion. The KorroPad indicator test is thus an interesting alternative for manufacturers, processors, users and researchers to time consuming exposition experiments and complex electrochemical investigations, which are normally used to reveal surface-related processing errors resulting in reduced pitting corrosion resistance. Furthermore, the KorroPad indicator test can be used to visualize alloy- and microstructure-related factors causing susceptibility to pitting corrosion. The detection limit of the KorroPad indicator test was characterized in this work using reference alloys with different chromium content (5 % to 18 %). The alloy-specific detection limit was shifted successfully to higher chromium content by increasing the concentrations of NaCl and K3[Fe(CN)6]. The modified KorroPads can now be used to establish an alloy-specific quality control regarding the pitting corrosion resistance of different stainless steel grades.
Mit der KorroPad-Prüfung können lochkorrosionsanfällige Oberflächenbereiche einfach, schnell und kostengünstig nachgewiesen werden. Das KorroPad ist damit für Hersteller, Verarbeiter, Anwender und Forscher eine interessante Alternative zu zeitintensiven Auslagerungsversuchen und elektrochemischen Untersuchungsmethoden, die normalerweise bei der Charakterisierung nichtrostender Stähle zur Anwendung kommen. Mit der KorroPad-Prüfung können auch werkstoff- und gefügebedingte Einflussfaktoren sichtbar gemacht werden, die Lochkorrosionsanfälligkeit verursachen. Um dies zu veranschaulichen, wird die Nachweisgrenze des KorroPads an Referenzlegierungen mit abgestuftem Chromgehalt aufgezeigt. Darauf aufbauend wird dargestellt, wie die Sensibilisierung nichtrostender Stähle durch Chromverarmung mit einer gezielten Verschärfung der KorroPad-Prüfung nachgewiesen werden kann.
Mit der KorroPad-Prüfung können lochkorrosionsanfällige Oberflächenbereiche einfach, schnell und kostengünstig nachgewiesen werden. Das KorroPad ist damit für Hersteller, Verarbeiter, Anwender und Forscher eine interessante Alternative zu zeitintensiven Auslagerungsversuchen und elektrochemischen Untersuchungsmethoden, die normalerweise bei der Charakterisierung nichtrostender Stähle zur Anwendung kommen. Mit der KorroPad-Prüfung können auch werkstoff- und gefügebedingte Einflussfaktoren sichtbar gemacht werden, die Lochkorrosionsanfälligkeit verursachen. Um dies zu veranschaulichen, wird die Nachweisgrenze des KorroPads an Referenzlegierungen mit abgestuftem Chromgehalt aufgezeigt. Darauf aufbauend wird dargestellt, wie die Sensibilisierung nichtrostender Stähle durch Chromverarmung mit einer gezielten Verschärfung der KorroPad-Prüfung nachgewiesen werden kann.
Mit der KorroPad-Prüfung können lochkorrosionsanfällige Oberflächen einfach, schnell und kostengünstig nachgewiesen werden. Das KorroPad ist damit für Hersteller, Verarbeiter, Anwender und Forscher eine interessante Alternative zu zeitintensiven Auslagerungsversuchen und elektrochemischen Untersuchungsmethoden, die normalerweise bei der Charakterisierung nichtrostender Stähle zur Anwendung kommen. Mit der KorroPad-Prüfung können aber auch werkstoff und gefügebedingte Einflussfaktoren sichtbar gemacht werden, die Lochkorrosionsanfälligkeit verursachen. Um dies zu veranschaulichen, wird die Nachweisgrenze des KorroPads an Referenzlegierungen mit abgestuftem Chromgehalt aufgezeigt.
Darauf aufbauend wird dargestellt, wie die Sensibilisierung nichtrostender Stähle durch Chromverarmung mit einer gezielten Verschärfung der KorroPad-Prüfung nachgewiesen werden kann.
Mit der KorroPad-Prüfung können lochkorrosionsanfällige Oberflächen einfach, schnell und kostengünstig nachgewiesen werden. Das KorroPad ist damit für Hersteller, Verarbeiter, Anwender und Forscher eine interessante Alternative zu zeitintensiven Auslagerungsversuchen und elektrochemischen Untersuchungsmethoden, die normalerweise bei der Charakterisierung nichtrostender Stähle zur Anwendung kommen. Mit der KorroPad-Prüfung können aber auch werkstoff- und gefügebedingte Einflussfaktoren sichtbar gemacht werden, die Lochkorrosionsanfälligkeit verursachen. Um dies zu veranschaulichen, wird die Nachweisgrenze des Korro-Pads an Referenzlegierungen mit abgestuftem Chromgehalt aufgezeigt. Darauf aufbauend wird dargestellt, wie die Sensibilisierung nichtrostender Stähle durch Chromverarmung mit einer gezielten Verschärfung der KorroPad-Prüfung nachgewiesen werden kann.
Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised.
Zerstörungsfreie Prüfverfahren (ZfPBau-Verfahren) sind auch im Bauwesen stets an praxisrelevante Prüfaufgaben gekoppelt. Die Ermittlung beispielsweise eines Ist-Zustandes im Vorfeld einer Betoninstandsetzung oder die Ermittlung von Schadensursache und Schadensumfang als Folge wiederkehrender Untersuchungen von Brücken nach DIN 1076 sind etablierte Anwendungsgebiete der ZfPBau. Mit der Einführung der Nachrechnungsrichtlinie für Straßenbrücken im Jahr 2011 hat die Nachfrage nach ZfPBau-Dienstleistungen einerseits stark zugenommen, andererseits eröffnet sie Möglichkeiten, in statischen Nachweisen die tatsächlichen Eigenschaften bestehender Konstruktionen rechnerisch anzusetzen. Dazu aber müssen Messergebnisse statistisch bewertet werden können. Dies geschieht durch eine einheitliche Ermittlung der Messunsicherheit, mit der die Voraussetzungen geschaffen werden, um Messergebnisse von ZfPBau-Verfahren in statischen Berechnungen verwenden zu können. Im folgenden Beitrag wird gezeigt, wie Messgrößen der ZfPBau als (stochastische) Basisvariablen in probabilistische Nachweise zur Berechnung der Zuverlässigkeit einfließen können, indem Grenzzustandsgleichungen modifiziert werden. Mit dieser Vorgehensweise sind weitere Schlussfolgerungen aus den Ergebnissen möglich.
Validation of artificial defects for Non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. This is an essential prerequisite for round robin tests. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.
Validation of artificial defects for non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of Non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.
Tandem MS techniques are widely used for both, structure and sequence elucidation of biopolymers. Thereby, fragmentation activation is realized by various methods, for example with lasers or collisions with neutral gases. In this study, we present a new Tandem MS system using a commercially available vacuum ultraviolet lamp. On the one hand, this approach provides efficient fragmentation in both ionization modes, positive as well as negative. On the other hand, it enables an additional previously not achieved post ionization of the fragments. While the first results in atypical fragment patterns and, thus provides orthogonal information, the second is crucial especially to identify low abundant ions.
Tandem MS techniques are widely used for both, structure and sequence elucidation of biopolymers. Thereby, fragmentation activation is realized by various methods, for example with lasers or collisions with neutral gases. In this study, we present a new Tandem MS System using a commercially available vacuum ultraviolet lamp. On the one hand, this approach provides efficient fragmentation in both ionization modes, positive as well as negative. On the other hand, it enables an additional previously not achieved post ionization of the fragments. While the first results in atypical fragment patterns and, thus provides orthogonal information, the second is crucial especially to identify low abundant ions.
To keep up with emerging mycotoxins and their transformation products fast and reliable toxicity tests are needed. Toxicity testing of mycotoxins is carried out usually by performing in vitro assays or is evaluated by using laboratory animals like mice, rats or chicken in in vivo studies.
Settled between classical in vitro approaches and in vivo studies with higher animals are tests with the nematode Caenorhabditis elegans. Since Sydney Brenner described 1974 the cultivation and handling of C. elegans, this worm is widely used as model organism in developmental biology and neurology. Due to many benefits like easy and cheap cultivation, a completely sequenced genome and short generation time, it also plays an important role in toxicological research. Finally, the high number of conserved genes between human and C. elegans make the worm an ideal candidate for toxicological investigations.
In this study we used C. elegans to assess the toxic effects of the relevant food mycotoxin citrinin (CIT), the mycoestrogen zearalenone (ZEN) and the modified mycotoxin ZEN-14-sulfate (ZEN-14-S) on different lifetable parameters including reproduction, thermal and oxidative stress tolerance and lifespan. All tested mycotoxins significantly decreased the amount of offspring. In case of ZEN and CIT also significant negative effects on stress tolerance and lifespan were observed compared to the control group.
Moreover, metabolization of mycotoxins in the worms was investigated by using LC MS/MS. Extraction of the worms treated 5 days with mycotoxin-containing and UVC-killed bacteria showed metabolization of ZEN to α-ZEL and β-ZEL (ZEL = zearalenol, ratio about 3:2). ZEN 14-S was reduced to ZEL 14-S and CIT was metabolized to mono hydroxylated CIT.
In der Berliner Sammlung "Manuscripta Americana" befinden sich Fragmente von Bilderhandschriften, die Alexander von Humboldt 1804 in Mexiko erwarb und der Königlichen Bibliothek schenkte. Die in der frühen Kolonialzeit hergestellten verschiedenartigen Codices waren damals schon nicht mehr an den Orten ihrer ursprünglichen Verwendung. Entsprechend ihres Seltenheitswertes gelangten einzelne Schriftstücke seit der Conquista in die Bestände bedeutender Persönlichkeiten. Hierzu fertigte man auch Abschriften oder Kopien an, oder zerstückelte sogar einzelne Blätter, so dass die Darstellungen auf den abgetrennten Fragmenten oft nur zum Teil abgebildet vorliegen.
Um herauszufinden, ob einige Schriftstücke der "Humboldt Codices" in Bezug zu einander stehen, werden die Dokumente, ihre Symbole und Schriftzeichen und das zur Herstellung verwendete Material miteinander verglichen.
Mit den für die Analyse von Manuskripten bewährten Untersuchungsmethoden werden Papier und Farbmittel identifiziert. Hierzu zählen Raman-, FTIR-, Röntgenfluoreszenz- und VIS- Spektroskopie. Charakteristisch für die Herstellung von schriftlichen Dokumenten in der Kolonialzeit von Amerika ist die Verwendung von indigenem Material wie Papier aus Baumrinde und Pflanzenfarben zusammen mit den aus Europa bekannten Materialien. Geklärt wird, inwieweit neben den bekanntesten Farbstoffen wie Cochenille, Mayablau oder Mischungen mit Tonmineralen auch mineralische Pigmente zum Einsatz kamen.
Vorgestellt werden die auf Tafel 36 in den "Vues des Cordillères et Monuments des Peuples Indigènes de l`Amerique, Voyage de Humboldt et Bonpland" abgebildeten Fragmente. Die hier von Humboldt vorgenommene Zusammenstellung wird mit der Farbpalette der in Berlin archivierten originalen Schriftstücke verglichen. Die Interpretation der Ergebnisse gibt einen Hinweis auf die Zuordnung oder auch Zusammengehörigkeit dieser einzigartigen Dokumente amerikanischer Geschichte. Hierbei wird die Frage aufgeworfen, inwiefern davon auszugehen ist, dass diese mit weiteren Fragmenten in Verbindung gebracht werden können, was für die Beleuchtung der kulturhistorischen Zusammenhänge von großer Bedeutung ist.
Ionophore Antibiotika werden zum Schutz gegen Kokzidiose eingesetzt, hauptsächlich in der Geflügelmast. Rückstände dieser Substanzen und deren Transformationsprodukte (TP) gelangen über den Metabolismus zum einen in das Geflügelfleisch, aber auch durch Ausscheidung in die Umwelt, da Tiermist als Dünger verwendet wird. Ziel dieser Forschungsarbeit ist es, die TP-Bildung von vier verschiedenen Ionophoren Antibiotika (Monensin (MON), Salinomycin (SAL), Maduramicin (MAD) und Lasalocid (LAS)) zu untersuchen. TPs werden durch den Biotransformationsprozess (Metabolismus) gebildet, dieser Prozess kann in zwei Phasen eingeteilt werden. Während in Phase I Oxidations-, Reduktions- oder Hydrolysereaktionen auftreten, ist Phase II von Konjugationsreaktionen geprägt. Durch diesen Prozess werden die Substanzen besser ausscheidbar.
Natürliche Redox-Vorgänge, wie sie bei der Biotransformation (Phase I) auftreten, können mit elektrochemischen (EC) Systemen simuliert werden. In einer EC-Durchflusszelle findet die Reaktion abhängig vom angelegten Potential statt. Im positiven Potentialbereich (0.0 bis 3.0 V; vs. Pd/H2) werden die Analyten oxidiert und somit oxidative TPs generiert. Durch die online-Kopplung mit Flüssigkeitschromatografie (LC) und Massenspektrometrie (MS) wird zunächst eine säulenchromatografische Trennung der generierten TPs erhalten, gefolgt von der massenspektrometischen Detektion. Durch die online-Kopplung von EC-(LC)-MS ergibt sich eine schnelle Analysemöglichkeit von der TP-Erzeugung ausgewählter Substanzen bis hin zur Detektion, wodurch gleichzeitig eine Identifizierung möglich ist.
Die ausgewählten Ionophoren Antibiotika wurden mittels EC-(LC)-MS auf auftretende TPs untersucht. Die ersten Ergebnisse zeigen ein breites Spektrum unterschiedlicher TPs abhängig von gewählten EC-Parametern wie Lösemittel, Modifier und insbesondere vom Arbeitselektrodenmaterial der EC-Durchflusszelle. Unter den erhaltenen TPs sind sowohl bekannte als auch unbekannte TPs vertreten, so dass weitere Untersuchungen zur Strukturaufklärung und vergleichende Tests zu Phase I Metaboliten (z.B. durch Metabolismus-Studien mit Mikrosomen) geplant sind.
Analog zu Blitz und Donner können elektrische Entladungen innerhalb eines Gasvolumens als akustische Quellen agieren und haben daher eine starke Verbreitung als diagnostische Methode (bspw. in der Raumakustik und bei der Ortung von Teilentladungen). Diese auf dem Prinzip der Thermoakustik beruhende Möglichkeit der Schallerzeugung und die damit verbundenen physikalischen Wechselwirkungen machen die Notwendigkeit einer mechanisch ausgelenkten Membran überflüssig. Dabei wird dem hochfrequenten Träger das Nutzsignal aufgeprägt, welches eine Volumenänderung des umliegenden Gases um seinen Ruhezustand verursacht. Durch die somit hervorgerufene zyklische thermische Wechselwirkung mit dem umliegenden Gasgemisch bedarf es daher ebenfalls keiner akustischen Anpassung. In den vorgestellten Ergebnissen wurde das Übertragungsverhalten eines Oberflächenplasmas (SDBD, surface dielectric barrier discharge) untersucht. Als Maß für den Wirkungsgrad und das Übertragungsverhalten des Aktuators wurden Klirrfaktor- und THD- Messungen und unter Variation der Eingangsleistungen durchgeführt. Durch die positiven akustischen Eigenschaften eröffnen sich neue Applikationen für den Einsatz von Plasmahochtönern wie bspw. zerstörungsfreie Werkstoffprüfung von Verbundsystemen und Klebeverbindungen im Automobilsektor oder im Bauwesen.
Analog zu Blitz und Donner können elektrische Entladungen innerhalb eines Gasvolumens als akustische Quellen agieren und haben daher eine starke Verbreitung als diagnostische Methode (bspw. in der Raumakustik und bei der Ortung von Teilentladungen). Diese auf dem Prinzip der Thermoakustik beruhende Möglichkeit der Schallerzeugung und die damit verbundenen physikalischen Wechselwirkungen machen die Notwendigkeit einer mechanisch ausgelenkten Membran überflüssig. Dabei wird dem hochfrequenten Träger das Nutzsignal aufgeprägt, welches eine Volumenänderung des umliegenden Gases um seinen Ruhezustand verursacht. Durch die somit hervorgerufene zyklische thermische Wechselwirkung mit dem umliegenden Gasgemisch bedarf es daher ebenfalls keiner akustischen Anpassung.
In den vorgestellten Ergebnissen wurde das Übertragungsverhalten eines Oberflächenplasmas (SDBD, surface dielectric barrier discharge) untersucht. Als Maß für den Wirkungsgrad und das Übertragungsverhalten des Aktuators wurden Klirrfaktor- und THD-Messungen und unter Variation der Eingangsleistungen durchgeführt.
Durch die positiven akustischen Eigenschaften eröffnen sich neue Applikationen für den Einsatz von Plasmahochtönern wie bspw. zerstörungsfreie Werkstoffprüfung von Verbundsystemen und Klebeverbindungen im Automobilsektor oder im Bauwesen.
Dielectric spectroscopy (BDS) was employed to investigate the dynamics of thin films (7 – 200 nm) of a Poly (vinyl methyl ether) (PVME) / Polystyrene (PS) blend (50:50 wt%). For the BDS measurements Nano-Structured Capacitors (NSC) were employed, where films have a free surface. This method was applied for film thicknesses up to 36 nm. Thicker films were prepared between Crossed Electrodes Capacitors (CEC). The spectra of the films showed multiple processes. The first process was assigned to the -relaxation of a bulk-like layer. For films measured by NSC, its rates were higher compared to that of the bulk blend. This behavior was related to a PVME-rich free-surface layer. A second process was observed for films measured by CEC (process X) and the 36 nm film measured by NSC (process X2). This process was assigned to fluctuations of PVME constraint by PS. Its activation energy was found to be thickness dependent, due to the evidenced thickness dependency of the compositional heterogeneity. Finally, a third process with an activated temperature-dependence was observed for all films measured by NSC (process X1). It resembled the molecular fluctuations in an adsorbed layer found for films of pure PVME.
Unprecedented Ionization Processes in Mass SpectrometryProvide Missing Link between ESI and MALDI
(2018)
In the field of mass spectrometry,producing intact, highly-charged protein ions from surfaces is a conundrum with significant potential payoff in application areas ranging from bio-medical to clinical research. Here, we report on the ability to form intact, highly-charged protein ions on high vacuum time-of-flight mass spectrometers in the linear and reflectron modes achievable using experimental conditions that allow effective matrix removal from both the sample surfaces and from the charged clusters formed by the laser Ablation event. The charge states are the highest reported on high vacuum mass spectrometers, yet they remain at only around athird of the highest charge obtained using laser ablation with a suitable matrix at atmospheric pressure. Other than physical instrument modifications, the key to forming abundant and stable highly-charged ions appears to be the volatility of the matrix used. Cumulative results suggest mechanistic links between the ionization process reported here and traditional ionization methods of electrospray ionization and matrix-assisted laser desorp-tion/ionization.
The structure and molecular dynamics of thin polymer films are of topical interest of soft matter-physics. Commonly, spatial structural heterogeneities of 1D confined thin films (surface, bulk-like and adsorbed layer), are expected to alter the glassy dynamics, compared to the bulk. Here, Specific Heat Spectroscopy (SHS) was used, to investigate the glassy dynamics of thin films of an asymmetric miscible PVME/PS 25/75 wt% blend. SHS measurements showed a non-monotonous thickness dependence of the dynamic Tg, on the contrary to the previously investigated PVME/PS 50/50 wt%. For PVME/PS 25/75 wt% thin films (> 30 nm), due to the presence of PVME-rich adsorbed and surface layers, the bulk-like layer experienced a thickness dependent increase of PS concentration. This led to a systematic increase of dynamic Tg. Further decrease of the film thickness (< 30 nm), resulted in a decrease of dynamic Tg, ascribed to the influence of the surface layer, which has a high molecular mobility. This is the first study, which shows deviations of dynamic Tg of thin films, compared to the bulk, resulting from the counterbalance of the free surface and adsorbed layer.
While studying the socio-geographic history of inks, division 4.5 of the BAM (Bundesanstalt für Materialforschung und Prüfung) together with the Centre for the Study of Manuscript Cultures in Hamburg has developed a protocol for ink analysis. It consists of a primary screening to determine the type of the ink and a subsequent in-depth analysis using several spectroscopic techniques: XRF, FTIR, and Raman. In most cases, we can obtain satisfactory results using a non-invasive protocol. However, mixed inks that contain no metals evade such a protocol. These inks constitute a heterogeneous group of media used especially in the Middle East and the Islamicate world since at least the 10th century; they are characterized by blending carbon ink and tannins, with or without the addition of vitriol.
Our own research aims primarily at recreating a socio-geographic history of inks, parchment, and papyrus and includes the comparative analysis of the writing materials of the Dead Sea Scrolls, ink and papyrus in Ancient and Hellenistic Egypt, and inks in documents from various contemporary medieval communities in Fustat (first nucleus of Cairo). During many years of study, we concluded that the continuous production of Coptic manuscripts from late Antiquity to the Middle Ages offers a unique opportunity for historical study of the ink in a large geographic area. Thanks to the collaboration with the ERC project “PAThs” (www.paths.uniroma1.it), based at the University of Rome La Sapienza, and within the activities of a PhD research dedicated to this topic, we therefore created a new branch of our project focused entirely on the analysis of Coptic inks, pigments, and dyes. This pioneering systematic study of writing materials coming from a specific area and time frame (5th-10th century) aims not only at a better understanding of the complex Coptic multicultural and plurilingual society, but also and mainly at clarifying the links among the Coptic and other societies between the ancient and medieval eras. Finally, it will cast light on the history of the technological development of inks in the eastern world, from Antiquity to the middle ages.
Alternariol (AOH) and Alternariol monomethylether (AME) are two secondary metabolites of Alternaria fungi which can be found in various foodstuffs like tomatoes, nuts and grains. Due to their toxicity and potential mutagenic activity the need for the development of high-throughput methods for the supervision of AOH- and AME-levels is of increasing interest. As the availability of both native and labelled AOH and AME analytical standards is very limited we herein wish to present a novel concise approach towards their synthesis employing a ruthenium-catalyzed ortho-arylation4 as the key step.
Previous work has shown that ultrasonic monitoring using externally applied or embedded transducers and imaging methods based on coda wave interferometry are able to detect subtle changes in concrete elements. In this study, a limited number of embedded transducers has been used to monitor changes in several 12 m long two-span concrete beams subjected to point or linear loads until failure.
The ultrasonic results showed the high sensitivity to stress changes and the nonlinear character of the associated effects. However, the ultrasonic features showed a very good correlation to several conventional monitoring parameters. For higher loads (significant amount of cracking), the technique had to be modified to cope with large wave velocity variations and high decorrelation compared to the reference signal.
Using a very simple imaging procedure, the 2D stress field inside the beam has been visualized including inhomogeneities and artifact at places where cracking occurred at higher loads. The technique has the potential to be included in real time monitoring systems.
Ultrasonic transmission measurements are used to monitor concrete elements mostly on a laboratory scale since decades.
Recently, coda wave interferometry, a technique adapted from seismology, has been introduced to civil Engineering experiments. It can be used to reveal subtle changes in concrete samples and even large construction elements without having a transducer directly at the location where the change is taking place. The methodology works best with embedded transducers to avoid coupling issues or excessive environmental influence. These transducers can be used for newly built and existing structures. Recently, large concrete beams have been equipped with a network of transducers and loaded until failure. Using code wave interferometry, it was possible to visualize stress fields and damaged areas.
Die Untersuchung von Ultraschallausbreitung in periodischen Strukturen ist aktuell von großem Interesse für eine zielgerichtete Beeinflussung der Schallausbreitung. Die bekanntesten Vertreter periodischer Strukturen sind die sogenannten phononischen Kristalle. Als phononischen Kristall bezeichnet man eine periodische Struktur bestehend aus einer Matrix, in die Störungen aus einem zweiten Material eingebracht worden ist. Dabei unterscheiden sich Matrixmaterial und das eingebrachte Material sehr stark in ihren akustischen Eigenschaften. Ein phononischer Kristall erzeugt Bandlücken, in denen die Schalltransmission durch den Kristall vollständig unterbunden ist. Außerhalb der Bandlücken hingegen findet eine ungehinderte Schallausbreitung statt. Diese speziellen Eigenschaften können beispielsweise dazu genutzt werden, frequenzselektive Wellenleiter zu konzipieren oder Schallfelder zu fokussieren. Die Kristallstrukturen können anhand der Anzahl der Dimensionen, in welchen eine Schallausbreitung unterbunden wird, unterteilt werden. So verhindert ein eindimensionaler Kristall nur die Schallausbreitung in eine Raumrichtung, wohingegen ein zwei- oder dreidimensionaler Kristall die Schallausbreitung in mehreren Raumrichtungen unterbindet. Für technische Anwendungen sind aufgrund ihrer einfachen Fertigung insbesondere ein- und zweidimensionale Strukturen von Interesse.
In den vorgestellten Arbeiten werden ein- und zweidimensionale Kristalle theoretisch und experimentell untersucht. Für den eindimensionalen Fall wurde eine entartete Form des phonischen Kristalls gewählt, wobei ein Vollzylinder mit periodischer Querschnittsänderung betrachtet wurde. Ziel ist es dabei, die Schallausbreitung in axialer Richtung zu verhindern. Inspiriert wurde diese Anordnung durch die in [1] vorgestellte Tubular-Bell-Geometrie und dient als Vorarbeit für die Entwicklung eines Sensorsystems. Im Falle des zweidimensionalen Kristalls wird die Schallausbreitung in einer Platte mit regelmäßigen Bohrungen untersucht. Hier soll keine Schallausbreitung in der Ebene stattfinden.
Als Voruntersuchungen werden zunächst Berechnungen mit Hilfe der Finiten Elementen Methode (FEM) und der Scaled Boundary Finite Element Method (SBFEM) durchgeführt. Für die Berechnung der Dispersionskurven der Strukturen wurde COMSOL Multiphysics genutzt. Die hierbei gewonnenen Erkenntnisse liefern eine Vorhersage der Übertragungseigenschaften der Strukturen. Zur Simulation der Schallausbreitung in der eindimensionalen Struktur wird ein effizienter, achsensymmetrischer Ansatz der SBFEM verwendet. Hierbei entsteht ein numerisches Modell mit einer sehr geringen Anzahl an Freiheitsgraden. Diese effiziente Beschreibung ermöglicht eine zielgerichtete Optimierung der Geometrie der Struktur in Hinblick auf die geforderten akustischen Eigenschaften.
Anhand der Simulationsergebnisse werden Testkörper für beide Strukturen gefertigt und deren Übertragungsverhalten im Vergleich mit den numerischen Ergebnissen experimentell überprüft.
[1] – Lucklum R., Zubtsov M., Pennec Y. – Tubular Bell – Ein neuartiger Ultraschall-Rohrsensor, 3. Workshop des Fachausschusses der DEGA e.V., Messtechnische Anwendung von Ultraschall 20.06-22.06.2016, Kloster Drübeck
Small organic molecule drugs are one of the key classes, taking increasingly important roles in modern drug development strategies. With the focus on small molecule drugs, difficulties originate frequently from a pronounced lipophilic character, resulting in poor water solubility, low bioavailability and unfavored pharmacokinetics. Recently, peptide-poly(ethylene glycol) conjugates (peptide-PEG conjugates) were described as precisely tunable platforms to solubilize a broad scope of fluorescent or non-fluorescent small organic molecules [1-2]. Selection of drug hosting peptides was achieved by combinatorial means, which can further be extended by implementation of a drug release screening step.
One-bead-one-compound peptide libraries are powerful tools to select high affinity binders. However, the selection of positive hits from the peptide libraries remains tedious as it occurs by handpicking, strongly limiting the pool of investigated beads. Here we report our recent results on improving the analytical platform, using automated fluorescence scanning and MALDI-ToF-ToF MS/MS imaging to screen larger sets of beads, broadening the statistical base and unraveling more precisely suitable peptides. The screening puts special emphasis on loading capacities and drug-release of transporters by performing additional washing steps in different media (cf. Fig. 1). Peptides representing strong, medium, weak releaser were chosen for further analysis and synthesized as peptide-polymer transporters. Release was analyzed by fluorescence anisotropy and fluorescence correlation spectroscopy, due to the fluorescent characteristics of the drug.
Solubilization studies confirmed sufficient loading capacities for a potential anti-Alzheimer disease drug of three transporter molecules representing strong/weak drug releaser, reaching solubilization of up to 1:3.4 (µmol drug/µmol conjugate). Fluorescence anisotropy and fluorescence correlation spectroscopy of the drug-loaded transporter showed significant differences in drug releasing properties, confirming the screening process.
Structured illumination using high-power diode lasers generates a two-dimensional interference of thermal waves. In addition, the sources and the sample are moving relative to each other. Using different configurations, we investigate the validity of the temporal and spatial superposition principle of the heat diffusion equation for these cases both experimentally and by numerical-analytical modelling. Furthermore, we investigate the potential of this approach for non-destructive testing.
Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and reproducible emission rates were obtained.
Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and re-producible emission rates were obtained.
Analysis of microplastic particles (MP) in environmental samples needs sophisticated techniques and is time intensive due to sample preparation and detection. An alternative to the most common (micro ) spectroscopic techniques, FTIR or Raman spectroscopy, are the thermoanalytical methods, where specific decomposition products can be analyzed as marker compounds for different kind of plastics types and mass contents. Thermal extraction desorption gas chromatography mass spectrometry (TED-GC-MS) allows the fast identification and quantification of MP in environmental samples without sample preparation. Whereas up to now only the analysis of thermoplastic polymers was realized, this is the first time that even the analysis of tire wear (TW) content in environmental samples is possible. Various marker compounds for TW were identified. They include characteristic decomposition products of elastomers, antioxidants and vulcanization agents. Advantages and drawbacks of these marker substances were evaluated. Environmental samples from street run off were exemplarily investigated and presented.
For years there have been more and more reports on the presence of drugs in the aquatic environment. Due to the demographic change, the consumption of pharmaceuticals has risen sharply. After taking the drugs, they are partly metabolized in the human body. However, the metabolism is not complete so that both the metabolites and non-metabolized amounts of the parent compounds are excreted. These compounds reach the waste water and afterwards the sewage treatment plants. In sewage treatment plants transformation products can be formed by the oxidative conditions during wastewater treatment processes. The transformation products may have a higher toxicity than the actual environmental pollutants and are often only partly removed during the waste water treatment. Since a lot of these compounds are still unknown, the transformation products are not detected by target analysis used in sewage treatment plants and are often released undetected in the aquatic ecosystems. The released substances may be subject to additional transformation processes in the environment. Pharmaceuticals produced in high amounts can be already detected in the μg/L range in water bodies worldwide.
Metformin and its major transformation product guanylurea are one of the main representatives. Metformin is the drug of choice for treating type 2 diabetes. The drug therapy for diabetes mellitus has increased significantly in recent years. In the year 2015 1500 tons of metformin were prescribed in Germany (for statutory insured persons). Metformin is not metabolized in the human body and is excreted unchanged therefore concentrations between 57 μg/L and 129 μg/L are found in German waste water treatment plants influents.
In this work the transformation of the antidiabetic drug metformin is investigated. The degradation of metformin is initialize by commercial water treatment techniques like UV-radiation or noncommercial techniques like heterogenous photocatalysis based on titanium dioxide. The degradation of metformin and resulting transformation products are analyzed by LC-MS/MS and LC-HRMS.
Thermoresponsive polymer coatings can facilitate cell sheet fabrication under mild conditions by promoting cell adhesion and proliferation at 37 1C. At lower temperatures the detachment of confluent cell sheets is triggered without enzymatic treatment. Thus, confluent cell sheets with intact extracellular matrix for regenerative medicine or tissue engineering applications become available. Herein, we applied the previously identified structural design parameters of functional, thermoresponsive poly(glycidyl ether) brushes on gold to the more application-relevant substrate glass via the self-assembly of a corresponding block copolymer (PGE-AA) with a short surface-reactive, amine-presenting anchor block. Both, physical and covalent immobilization on glass via either multivalent ionic interactions of the anchor block with bare glass or the coupling of the anchor block to a polydopamine (PDA) adhesion layer on glass resulted in stable coatings. Atomic force microscopy revealed a high degree of roughness of covalently attached coatings on the PDA adhesion layer, while physically attached coatings on bare glass were smooth and in the brush-like regime. Cell sheets of primary human dermal fibroblasts detached reliably (86%) and within 20 ± 10 min from physically tethered PGE-AA coatings on glass when prepared under cloud point grafting conditions. The presence of the laterally inhomogeneous PDA adhesion layer, however, hindered the spontaneous temperature-triggered cell detachment from covalently grafted PGE-AA, decreasing both detachment rate and reliability. Despite being only physically attached, self-assembled monolayer brushes of PGE-AA block copolymers on glass are functional and stable thermoresponsive coatings for application in cell sheet fabrication of human fibroblasts as determined by X-ray photoelectron spectroscopy.
To keep pace with the rising number of detected mycotoxins, there is a growing need for fast and reliable toxicity tests to assess the potential threat to food safety. Toxicity tests with the bacterial-feeding nematode Caenorhabditis elegans as model organism are well established. In this study the C. elegans wildtype strain N2 (var. Bristol) was used to investigate the toxic effects of the food-relevant mycotoxins citrinin (CIT) and zearalenone-14-sulfate (ZEA-14-S) and zearalenone (ZEA) on different life cycle parameters including reproduction, thermal and oxidative stress resistance and lifespan. The metabolization of the mycotoxins by the nematodes in vivo was investigated using HPLC-MS/MS. ZEA was metabolized in vivo to the reduced isomers α-zearalenol (α-ZEL) and β-ZEL. ZEA 14-S was reduced to α-/β-ZEL 14-sulfate and CIT was metabolized to mono-hydroxylated CIT. All mycotoxins tested led to a significant decrease in the number of nematode offspring produced. ZEA and CIT displayed negative effects on stress tolerance levels and for CIT an additional shortening of the mean lifespan was observed. In the case of ZEA-14-S, however, the mean lifespan was prolonged. The presented study shows the applicability of C. elegans for toxicity testing of emerging food mycotoxins for the purpose of assigning potential health threats.
Nowadays the Instrumented Indentation Testing (IIT) is one of the most commonly used methods to determine the mechanical properties of materials in the nano range. This method is already extensive standardized in EN ISO 14577 part 1-4. Because of the great interest of researchers and industries in investigations of time depending material behavior mostly all suppliers of IIT equipment are offering the possibility of dynamic testing. Realizing this development ISO/TC 164/SC3 Hardness Testing has proposed to start the new standardization project “Linear elastic dynamic instrumented indentation testing DIIT”. The development of this standard is accompanied by the first international intercomparing exercise comparing results of dynamic instrumented indentation testing from testing machines using different hardware solutions and different models for data evaluation.
The draft of part 5 of ISO 14577 “Linear elastic dynamic instrumented indentation testing DIIT” specifies verification and calibration of testing machines for carrying out the measurement of the dynamic material response when an oscillatory force or displacement, with amplitudes small in comparison to the prescribed target values, is imparted to the indenter while the indenter is continuously loaded to a prescribed target load or target depth or while the load or displacement is held constant at a prescribed target value. In case of a material showing plastic-elastic behavior, the measured dynamic response is used for continuous evaluation of the dynamic stiffness of the contact as a function of depth and frequency. Using the dynamic stiffness of the contact a reduced dynamic modulus will be calculated. In case of a material showing visco-elastic behavior from the measured dynamic response also the dynamic contact damping coefficient as function of depth and frequency is evaluated continuously. Using dynamic contact stiffness and dynamic contact damping coefficient reduced lost and storage modulus for visco-elastic materials will be calculated.
The main normative requirements of the draft will be presented and discussed in the light of the first results of the intercomparing excise.
Analysis of single cells via LA-ICP-MS is a technique with great potential, however manual targeting of single cells is laborious and therefore microarraying of cells looks promising. In this work, we investigate the potential of a commercial non-contact piezo dispenser arraying system (S3, Scienion AG, Berlin), equipped with a novel technology for single-cell isolation called CellenONE™ (Cellenion, Lyon). Usually if one aims to create a microarray of single cells via spotting a suitably diluted cell suspension, one will observe a Poisson-distributed cell number per spot. CellenONE™ overcomes this problem by controlling the number of cells optically in the piezo dispense capillary (PDC) via image recognition to obtain true single cell arrays. The figures of merit of the customized and optimized setup will be presented. In a proof of concept experiment we investigated the trace elemental fingerprint of THP-1 cells by LA-ICP-TOF-MS (Analyte G2, Teledyne Cetac; icpTOF, TOFWERK) and quantified two metal cell dyes, mDOTA-Ho (CheMatech, Dijon), and Ir-DNA intercalator (Fluidigm, San Francisco). For that, matrix matched calibration standards after Wang et al. were successfully prepared using the same arraying system. We believe that this novel approach opens new ways for automated quantitative single cell LA-ICP-MS.
Half-Cell-Potential Mapping (HP) is the most popular non-destructive testing (NDT) method for the detection of active corrosion in reinforced concrete. HP is influenced by parameters such as moisture and chloride gradients in the component. The sensitivity to the spatially small, but dangerous pitting is low. In this study we show how additional measurement information can be used with multi-sensor data fusion to improve the detection performance and to automate data evaluation. The fusion is based on supervised machine learning (SML). SML are methods that recognize relationships in (sensor) data based on given labels. We use SML to distinguish "defective" and "intact" labeled areas in our dataset. It consists of 18 measurement - each contains HP, ground radar, microwave moisture and Wenner resistance data. Exact labels for changing environmental conditions were available in a laboratory study on a reinforced concrete slab, which deteriorated controlled and accelerated. The deterioration progress was monitored continuously and corrosion was generated targeted at a predefined location. The detection results are quantified and statistically evaluated. The SML results shows a significant improvement over the best single method (HP).
Half-Cell-Potential Mapping (HP) is the most popular non-destructive testing (NDT) method for the detection of active corrosion in reinforced concrete. HP is influenced by parameters such as moisture and chloride gradients in the component. The sensitivity to the spatially small, but dangerous pitting is low. In this study we show how additional measurement information can be used with multi-sensor data fusion to improve the detection performance and to automate data evaluation. The fusion is based on supervised machine learning (SML). SML are methods that recognize relationships in (sensor) data based on given labels. We use SML to distinguish "defective" and "intact" labeled areas in our dataset. It consists of 18 measurement - each contains HP, ground radar, microwave moisture and Wenner resistivity data. Exact labels for changing environmental conditions were determined in a laboratory study on a reinforced concrete slab, which deteriorated controlled and accelerated. The deterioration progress was monitored continuously and corrosion was generated targeted at a predefined location. The detection results are quantified and statistically evaluated. The data fusion shows a significant improvement over the best single method (HP). We describe the challenges of data-driven approaches in nondestructive testing and show possible solutions.
Time-resolved phase-contrast microscopy is employed to visualize spatio-temporal thermal transients induced by tight focusing of a single Ti:sapphire fs-laser pulse into a solid dielectric sample. This method relies on the coupling of the refractive index change and the sample temperature through the thermo-optic coefficient dn/dT. The thermal transients are studied on a timescale ranging from 10 ns up to 0.1 ms after laser excitation. Beyond providing direct insights into the laser–matter interaction, analyzing the results obtained also enables quantifying the local thermal diffusivity of the sample on a micrometer scale. Studies conducted in different solid dielectrics, namely amorphous fused silica (a-SiO2), a commercial borosilicate glass (BO33, Schott), and a custom alkaline earth silicate glass (NaSi66), illustrate the applicability of this approach to the investigation of various glassy materials.
Time-dependent in situ measurement of atmospheric corrosion rates of duplex stainless steel wires
(2018)
Corrosion rates of strained grade UNS S32202 (2202) and UNS S32205 (2205) duplex stainless steel wires have been measured, in situ, using time-lapse X-ray computed tomography. Exposures to chloride-containing (MgCl2) atmospheric environments at 50 °C (12–15 M Cl− and pH ~5) with different mechanical elastic and elastic/plastic loads were carried out over a period of 21 months. The corrosion rates for grade 2202 increased over time, showing selective dissolution with shallow corrosion sites, coalescing along the surface of the wire. Corrosion rates of grade 2205 decreased over time, showing both selective and pitting corrosion with more localised attack, growing preferentially in depth. The nucleation of stress corrosion cracking was observed in both wires.
THz and mid IR spectroscopy of high-molecular PE (HMW) and ultra high-molecular PE (UHMW) reveals modifications of the molecular structure. Characteristic absorption bands are changed if the two materials are exposed by γ-Co60 radiation up to 600 kGy and subsequently stored at an annealing temperature of 398 K until for 729 days.
Up to now THz-TDS-systems aren’t considered to be nondestructive testing facilities for large scale industrial applications, despite it was proven that they provide a comprehensive set of quality parameters. A practical approach to bring THz-TDS in addition to already existing testing systems into the industrial mainstream is systematic development of future test procedures and test facilities for dielectrics. For this purpose polyeth-ylene test specimen with introduced artefacts were designed, to evaluate the detection sensitivity of Time of Flight measurements based on dielectrics. SAFT reconstructed tomograms are presented which visualize the sizes and location of artificially introduced flaws.
A great amount of material properties is strongly influenced by dislocations, the carriers of plastic deformation. It is therefore paramount to have appropriate tools to quantify dislocation substructures with regard to their features, e.g., dislocation density, Burgers vectors or line direction. While the transmission electron microscope (TEM) has been the most widely-used equipment implemented to investigate dislocations, it usually is limited to the two-dimensional (2D) observation of three-dimensional (3D) structures. We reconstruct, visualize and quantify 3D dislocation substructure models from only two TEM images (stereo pairs) and assess the results. The reconstruction is based on the manual interactive tracing of filiform objects on both images of the stereo pair. The reconstruction and quantification method are demonstrated on dark field (DF) scanning (S)TEM micrographs of dislocation substructures imaged under diffraction contrast conditions. For this purpose, thick regions (> 300 nm) of TEM foils are analyzed, which are extracted from a Ni-base superalloy single crystal after high temperature creep deformation. It is shown how the method allows 3D quantification from stereo pairs in a wide range of tilt conditions, achieving line length and orientation uncertainties of 3% and 7°, respectively. Parameters that affect the quality of such reconstructions are discussed.
In this work, two novel donor/acceptor (D/A) complexes, namely, diindenoperylene (DIP)/1,3,4,5,7,8-hexafluoro-tetracyanonaphthoquinodimethane (F6TCNNQ) and alpha-sexithiophene (6T)/F6TCNNQ, are studied. The D/A complexes segregate in form of π−π stacked D/A cocrystals and can be observed by X-ray scattering. The different conformational degrees of freedom of the donor molecules, respectively, seem to affect the thin-film crystalline texture and composition of the D/A mixtures significantly. In equimolar mixtures, for DIP/F6TCNNQ, the crystallites are mostly uniaxially oriented and homogeneous, whereas for 6T/F6TCNNQ, a mostly 3D (isotropic) orientation of the crystallites and coexistence of domains of pristine compounds and D/A complex, respectively, are observed. Using optical absorption spectroscopy, we observe for each of the two mixed systems a set of new, strong transitions located in the near-IR range below the gap of the pristine compounds: such transitions are related to charge-transfer (CT) interactions between donor and acceptor. The optical anisotropy of domains of the D/A complexes with associated new electronic states is studied by ellipsometry. We infer that the
CT-related transition dipole moment is perpendicular to the respective π-conjugated planes in the D/A complex.
Polymers at interfaces play a major role in a broad variety of applications ranging from engineering purposes (for instance polymer based nanocomposites) to high tech implications (for instance light emitting diodes).
Here, thin films with thicknesses down to few nanometers are prepared on different substrates as model systems for polymer composites. The thin films are investigated by a combination of surface analytical and volume sensitive methods. As surface analytical methods atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and contact angle measurements (CAM) are employed. As volume sensitive broadband dielectric spectroscopy (BDS), specific heat spectroscopy (SHS), and ellipsometry are used. Especially attention is paid to understand the glass transition behavior of thin films because the glass transition is the key phenomenon determines the application of polymers also in thin films.
To understand the glass transition behavior of thin films, which is controversially discussed in literature, a three layer model is discussed. Firstly, a mobile surface layer is assumed at polymer air interface of the film due to missing of segment/segment interactions. Secondly, in the middle of the film a bulk-like layer should be expected. Thirdly, for polymers having non-repulsive interactions with the substrate an irreversibly adsorbed layer is expected to be formed. Due the adsorption the molecular mobility of the segments in this layer is slowed down. What is measured for the glass transition of thin films is a complicated average of all of these effects. The different layers are hardly to address separately. Therefore, in the presentation especially model systems are selected and investigated to verify the layer model.
In the field of optically excited thermography, flash lamps (impulse shaped planar heating) and halogen lamps (modulated planar heating) have become established for the specific regimes of impulse and lock-in thermography. Flying-spot laser thermography is implemented by means of a rasterized focused laser, e. g. for crack detection (continuous wave operation) and photothermal material characterization (high-frequency modulated). The availability of novel technologies, i. e. fast and high-resolution IR cameras, brilliant innovative light sources and high-performance data acquisition and processing technology will enable a paradigm shift from stand-alone photothermal and thermographic techniques to uniform quantitative measurement and testing technology that is faster and more precise. Similar to an LED array, but with irradiance two orders of magnitude higher, a new type of brilliant laser source, i. e. the VCSEL array (vertical-cavity surface-emitting laser), is now available. This novel optical energy source eliminates the strong limitation to the temporal dynamics of established light sources and at the same time is spectrally clearly separated from the detection wavelength. It combines the fast temporal behavior of a diode laser with the high optical irradiance and the wide illumination area of flash lamps. In addition, heating can also be carried out in a structured manner, because individual areas of the VCSEL array can be controlled independently of each other. This new degree of freedom enables the development of completely new thermographic NDT methods.
Thermographic NDE is based on the interaction of thermal waves with inhomogeneities. These inhomogeneities are related to sample geometry or material composition. Although thermography is suitable for a wide range of inhomogeneities and materials, the fundamental limitation is the diffusive nature of thermal waves and the need to measure their effect radiometrically at the sample surface only. The propagation of the thermal waves from the heat source to the inhomogeneity and to the detection surface results in a degradation in the spatial resolution of the technique. A new concerted ansatz based on a spatially structured heating and a joint sparsity of the signal ensemble allows an improved reconstruction of inhomogeneities. As a first step to establish an improved thermographic NDE method, an experimental setup was built based on structured 1D illumination using a flash lamp behind a mechanical aperture. As a follow-up to this approach, we now use direct structured illumination using a 1D laser array. The individual emitter cells are driven by a random binary pattern and additionally shifted by fractions of the cell period. The repeated measurement of these different configurations with simultaneously constant inhomogeneity allows for a reconstruction that makes use of joint sparsity. With analytical-numerical modelling or numerical FEM simulations, we study the influence of the parameters on the result of non-linear reconstruction. For example, the influence of the illumination pattern as a variable heat flux density and Neumann boundary condition for convolution with the constant Green's function can be studied. These studies can be used to derive optimal conditions for a measurement technique.
Among the photothermal methods, full-field thermal imaging is used to characterize materials, to determine thicknesses of layers, or to find inhomogeneities such as voids or cracks. The use of classical light sources such as flash lamps (impulse heating) or halogen lamps (modulated heating) led to a variety of nondestructive testing methods, in particular, lock-in and flash-thermography. In vertical-cavity surface-emitting lasers (VCSELs), laser light is emitted perpendicularly to the surface with a symmetrical beam profile. Due to the vertical structure, they can be arranged in large arrays of many thousands of individual lasers, which allows power scaling into the kilowatt range. Recently, a high-power yet very compact version of such a VCSEL-array became available that offers both the fast timing behavior of a laser as well as the large illumination area of a lamp. Moreover, it allows a spatial and temporal control of the heating because individual parts of the array can be controlled arbitrarily in frequency, amplitude, and phase. In conjunction with a fast infrared camera, such structured heating opens up a field of novel thermal imaging and testing methods. As a first demonstration of this approach, we chose a testing problem very challenging to conventional thermal infrared testing: The detection of very thin subsurface defects perpendicularly oriented to the surface of metallic samples. First, we generate destructively interfering thermal wave fields, which are then affected by the presence of defects within their reach. It turned out that this technique allows highly sensitive detection of subsurface defects down to depths in excess of the usual thermographic rule of thumb, with no need for a reference or surface preparation.
Thermal waves are solutions of the heat diffusion equation for periodic boundary conditions and can be seen analogously to strongly damped waves. Although the underlying differential equation differs from the wave equation, the essential property for analogy between both equations is linearity such that superposition applies. This linearity is maintained even after a linear transformation, such as the Fourier transform from time to frequency domain. It follows that the temporal superposition principle is already used in active thermography, e.g. in pulsed thermography, as a superposition of many individual frequencies. However, the systematic spatial superposition has not yet been fully exploited, mainly due to a lack of suitable energy sources.
As a first step, we are investigating how thermal wave fields of arbitrary space-time structures can be engineered using structured laser illumination. The proof of principle was shown using a laser coupled projector. Unfortunately, the available optical output power was limited due to the thermal stress limit of the device. That is why we are working towards a more sophisticated moving 1D array of high-power diode lasers. We characterized the novel light source and believe that apart from the benefit of spatial and temporal illumination it can combine the temporal regimes of impulse and lock-in thermography.
In a second step, we investigate moving and oscillating line sources with different line shapes. We use a Green’s Function ansatz to analytically model the thermal wave propagation of structured 1D laser illumination in isotropic materials. Furthermore, we show some methods how they can be implemented. With this technique, we were able to accelerate our detection method firstly presented in for vertical narrow defects by factor three. Generally, we believe that this technique opens up similar opportunities than in other NDE methods. High-resolution ultrasound, for example, is also based on the superposition of single emitters and a recent concept suggests an option to deal with the diffusion wave character of the thermal waves.
Reference materials are essential, when the accuracy and reliability of measurement results need to be guaranteed in order to generate confidence in the analysis.
These materials are frequently used for determining measurement uncertainty, for validation of methods, suitability testing and quality assurance. Especially direct solid sampling methods require reference materials for calibration.
They guarantee that measurement results can be compared to recognized reference values.
This presentation gives an overview about the use of GDMS in various certification procedures. Because it represents a fast, sensitive, multielement analyses technique without extensive sample preparation it plays a special role for the purity determination of high purity standards. Various calibration strategies and the preparation of traceable matrix matched calibration standards will be discussed.
For the certification of analyte content in matrix materials mainly techniques with solvent sample preparation are used. Here GD-MS is used to identify possible loss or contamination with analytes during the sample preparation step. Typically used acids to dissolve matrices lead to interferences in the ICP- mass spectrometric detection of various analytes and their quantification. Here GD-MS as direct method can also add an important contribution in the certification process.
Simulation becomes more and more important in modern CT imaging. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for educational purposes. The radiographic simulator aRTist is a modelling tool which simulates X-ray imaging using a hybrid analytical and Monte Carlo method to efficiently model the radiation transport. In addition to the relevant physical effects such as absorption, scattering and fluorescence, simplified fast models are employed to describe the characteristics of the X-ray source and the detector. aRTist is well equipped to model realistic X-ray imaging setups due to the ability to load exported CAD object descriptions. A simple CT scan module is contained in aRTist which allows the simulation of standard (circular cone beam) scanning trajectories.
TomoSynth is a module for aRTist which allows to set up more complex scanning trajectories by attaching geometrical modification functions to the objects in the radiographic scene. In this way, advanced scanning modes can be realized, for instance helical CT as an overlay of a rotation and a linear motion, or laminography as a motion of the source point. In addition to deterministic motion, also random variations can be introduced. By combining random variations with deterministic motion, non-ideal (realistic) CT scan geometries can be simulated, e.g. focal spot drift and mechanical instability of the axis of rotation. The TomoSynth module conveniently allows to construct these scenarios in a graphical interface and provides a preview before starting the (potentially long running) batch job. Therefore, deviations from ideal CT scan trajectories can be easily adjusted which is a necessary step towards uncertainty determination from simulation.
Airborne ultrasonic testing of lightweight, structured composite materials enables fast and contact-free non-destructive testing in aerospace and avoids material degradation due to contact with a coupling liquid. Established resonant air-coupled transducers consist of piezocomposite materials and several matching layers or more advanced materials like charged cellular polypropylene. The relaxation time and the specific frequency of such mechanical ultrasound emitters limit the spectrum of applications for each device. A short pulse length is key for reliable defect detection and each component at test can be best characterized at material- and geometry-specific frequencies. Here we show that focused thermoacoustic transducers are suited for testing lightweight, structured composite plates. Since the ultrasound is generated in air, these transducers show no resonance behavior and emit a broadband acoustic spectrum between 1.2 kHz and 1 MHz. Composite specimens of 3 mm to 9 mm thickness made of polylactide with a honeycomb structure were tested. Flat bottom holes were introduced to quantify the spatial resolution of the imaging method inside the strongly anisotropic specimen. As no broadband receivers are available yet, cellular polypropylene transducers were used as receivers, which limits the bandwidth of the method towards the bandwidth of the receiver. Nevertheless, we demonstrate the competitiveness of the thermoacoustic transducer compared to mechanical emitters at their respective resonance frequencies. Because a thermoacoustic transmitter features a nearly ideal pulse width, a single transmitter can be coupled with receivers with different resonance frequencies. With the development of broadband ultrasound receivers, air-coupled ultrasound spectroscopy will likely be possible in the near future. The analyzed transducer holds the potential to speed up testing during production and maintenance in aerospace and automotives. Its combination with a broadband receiver could also expand the application field of air-coupled ultrasonic testing from a qualitative error detection towards a quantitative, spatially resolved analysis of mechanical material properties.
Airborne ultrasonic testing of lightweight, structured composite materials enables fast and contact-free non-destructive testing in aerospace and avoids material degradation due to contact with a coupling liquid. Established resonant air-coupled transducers consist of piezocomposite materials and several matching layers or more advanced materials like charged cellular polypropylene. The relaxation time and the specific frequency of such mechanical ultrasound emitters limit the spectrum of applications for each device. A short pulse length is key for reliable defect detection and each component at test can be best characterized at material- and geometry-specific frequencies. Here we show that focused thermoacoustic transducers are suited for testing lightweight, structured composite plates. Since the ultrasound is generated in air, these transducers show no resonance behavior and emit a broadband acoustic spectrum between 1.2 kHz and 1 MHz. Composite specimens of 3 mm to 9 mm thickness made of polylactide with a honeycomb structure were tested. Flat bottom holes were introduced to quantify the spatial resolution of the imaging method inside the strongly anisotropic specimen. As no broadband receivers are available yet, cellular polypropylene transducers were used as receivers, which limits the bandwidth of the method towards the bandwidth of the receiver. Nevertheless, we demonstrate the competitiveness of the thermoacoustic transducer compared to mechanical emitters at their respective resonance frequencies. Because a thermoacoustic transmitter features a nearly ideal pulse width, a single transmitter can be coupled with receivers with different resonance frequencies. With the development of broadband ultrasound receivers, air-coupled ultrasound spectroscopy will likely be possible in the near future. The analysed transducer holds the potential to speed up testing during production and maintenance in aerospace and automotives. Its combination with a broadband receiver could also expand the application field of air-coupled ultrasonic testing from a qualitative error detection towards a quantitative, spatially resolved analysis of mechanical material properties.
A combination of different complementary methods is employed to investigate scaling of the molecular dynamics of two different liquid crystals. Each method is sensitive to different kind of fluctuations and provides therefore a different window to look at the molecular dynamics. In detail, broadband dielectric spectroscopy is combined with specific heat spectroscopy and neutron scattering. As systems the nematic liquid crystal E7 and a discotic liquid crystalline pyrene are considered. First of all it was proven that both systems show all peculiarities which are characteristic for glassy dynamics and the glassy state. Especially for the nematic liquid crystal E7 it could be unambiguously shown by a combination of dielectric and specific heat spectroscopy that the tumbling mode is the underlying motional process responsible for glassy dynamics. Dielectric investigations on the discotic liquid crystalline pyrene reveal that at the phase transition from the plastic crystalline to the hexagonal columnar liquid crystalline phase the molecular dynamics changes from a more strong to fragile temperature dependence of the relaxation rates. Moreover a combination of results obtained by specific heat spectroscopy with structural methods allows an estimation of the length scale relevant for the glass transition.
Digital transformation and especially the dramatic rise of products and services connected to the Internet of Things raise the questions on how to deal with the increasing risks related to Privacy and Cybersecurity. Presumably, these risks seem to be insufficiently reflected in the European Union’s current regulative system – by being neither part of the traditional definition of a safe product nor part of product-specific vertical or horizontal directives. Certification based on standards as underlying requirements has been identified by policymakers as an instrument to address this issue. The latest European draft regulation aims at increasing security and trust in ICT products and services, and reducing current European market fragmentation with a new Cybersecurity Certification Framework. Based on the results of a qualitative analysis of stakeholder statements on the current proposal on the Cybersecurity Act, this paper discusses elements of the proposed Cybersecurity Certification Framework. As a theoretical background, this paper provides definitions of the terms Safety, IT-security, and Cybersecurity, presents selected Cybersecurity-related standards and provides an outlook on future challenges to Conformity Assessment in the digital transformation.
Digital transformation and especially the dramatic rise of products and services connected to the Internet of Things raise the questions on how to deal with the increasing risks related to Privacy and Cybersecurity. Presumably, these risks seem to be insufficiently reflected in the European Union’s current regulative system – by being neither part of the traditional definition of a safe product nor part of product-specific vertical or horizontal directives. Certification based on standards as underlying requirements has been identified by policymakers as an instrument to address this issue. The latest European draft regulation aims at increasing security and trust in ICT products and services, and reducing current European market fragmentation with a new Cybersecurity Certification Framework. Based on the results of a qualitative analysis of stakeholder statements on the current proposal on the Cybersecurity Act, this paper discusses elements of the proposed Cybersecurity Certification Framework. As a theoretical background, this paper provides definitions of the terms Safety, IT-security, and Cybersecurity, presents selected Cybersecurity-related standards and provides an outlook on future challenges to Conformity Assessment in the digital transformation.
The quest for the mixed inks
(2018)
In this article, we would like to share our observations concerning the inks produced by intentionally mixing soot or charcoal with tannin extracts or iron-gall ink. Aside from Zerdoun’s mention in her outstanding review of written sources, “Les encres noires au Moyen-Âge”, this ink category has received little if any attention from scholars and scientists. And yet, if analytically attested, the use of such inks could serve as an additional category to classify and distinguish the writing inks on the historical socio-geographic map of the writing inks we are trying to build.
Amyloid fibrils are polymers formed by proteins under specific conditions and in many cases they are related to pathogenesis, such as Parkinson’s and Alzheimer’s diseases. Their hallmark is the presence of a β-sheet structure. High resolution structural data on these systems as well as information gathered from multiple complementary analytical techniques is needed, from both a fundamental and a pharmaceutical perspective. Here, a previously reported de novo designed, pH-switchable coiled coil-based peptide that undergoes structural transitions resulting in fibril formation under physiological conditions has been exhaustively characterized by transmission electron microscopy (TEM), cryo-TEM, atomic force microscopy (AFM), wide-angle X-ray scattering (WAXS) and solid-state NMR (ssNMR). Overall, a unique 2-dimensional carpet-like assembly composed of large coexisiting ribbon-like, tubular and funnel-like structures with a clearly resolved protofilament substructure is observed. Whereas electron microscopy and scattering data point somewhat more to a hairpin model of β-fibrils, ssNMR data obtained from samples with selectively labelled peptides are in agreement with both, hairpin structures and linear arrangements.
The physico-chemical basis of DNA radiosensitization: Implications for cancer radiation therapy
(2018)
High-energy radiation is used in combination with radiosensitizing therapeutics to treat cancer. The most common radiosensitizers are halogenatednucleo-sides and cisplatin derivatives, and recently also metal nanoparticles have been suggested as potentialradiosensitizing agents. The radiosensitizingaction of these compounds can at least partly be ascribed to an enhancedreactivity towards secondary low-energy electrons generated along the radiation track of the high-energyprimary radiation, or to an additional emission of secondary reactive electrons close to the tumor tissue. This is referred to as physico-chem ical radiosensitization. In this Conceptarticle we presentcurrent experimental methodsused to study fundamentalprocesses of physico-chemical radiosensitization and discuss the most relevant classes of radiosensitizers. Open questions in the current discussions are identified and future directions outlined, which can lead to optimized treatment protocols or even novel therapeuticconcepts.
The European Commission's recommendation on the definition of nanomaterial [2011/696/EU] is broadly applicable across different regulatory sectors and requires the quantitative size determination of constituent particles in samples down to 1 nm. A material is a nanomaterial if 50 % or more of the particles are in the size range 1-100 nm. The implementation of the definition in a regulatory context challenges measurement methods to reliably identify nanomaterials and ideally also non-nanomaterials as substance or product ingredient as well as in various matrices.
The EU FP7 NanoDefine project [www.nanodefine.eu] addressed these challenges by developing a robust, readily implementable and cost-effective measurement strategy to decide for the widest possible range of materials whether it is a nanomaterial or not. It is based on existing and emerging particle measurement techniques evaluated against harmonized, material-dependent performance criteria and by intra- and inter-lab comparisons. Procedures were established to reliably measure the size of particles within 1-100 nm, and beyond, taking into account different shapes, coatings and chemical compositions in industrial materials and consumer products. Case studies prove their applicability for various sectors, including food, pigments and cosmetics.
A main outcome is the establishment of an integrated tiered approach including rapid screening (tier 1) and confirmatory methods (tier 2), a decision support flow scheme and a user manual to guide end-users, such as manufacturers, in selecting appropriate methods. Another main product is the “NanoDefiner” e-Tool which implements the flow scheme in a user-friendly software and guides the user in a semi-automated way through the entire decision procedure. It allows a cost-effective selection of appropriate methods for material classification according to the EC's nanomaterial definition and provides a comprehensive report with extensive explanation of all decision steps to arrive at a transparent identification of nanomaterials as well as non-nanomaterials for regulatory purposes.
The project has received funding from the European Union’s Seventh Programme for research, technological development and demonstration under grant agreement No 604347.
The LAUS: First applications of a new system for ultrasonic imaging of very concrete structures
(2018)
The LAUS (Large Aperture Ultrasonic System) has been developed to image very thick concrete structures, which are not accessible for commercial systems. The device and the corresponding software is the result of joint research of BAM, an ultrasonic instrument manufacturer and University of Kassel, Germany. It consists of 12 separate arrays of 32 point-contact shear wave transducers each, which can be deployed in flexible configurations. Each array is combined with battery and transmitter, receiver and wireless communication electronics.
Three case histories are presented. First the system was deployed on a 5-m thick heavily reinforced foundation slab. The reflection of the slab’s bottom was imaged clearly. In addition, a multiple reflection was registered, thus giving hope that even thicker elements might be imaged by the instrument. Second, the LAUS was used to investigate a massive bridge girder where a heavy rainstorm during concreting had led to imperfections that were visible after removing the formwork was removed. The LAUS could image tendon ducts in 1.8m depth and the backwall closely behind them. Some limited areas showed blurred reflections and were checked by drill holes; these areas were affected by diffuse damage which could be repaired by injections. Third, a large retaining wall was checked for thickness.
Meanwhile, the LAUS has been used in underground waste deposits (nuclear and other) for quality assurance of sealing plugs. A confirmed penetration depth of about 7 m has been reached.
BACKGROUND CONTEXT: Targeted delivery of osteoinductive bone morphogenetic Proteins (eg, GDF5) in bioresorbable calcium phosphate cement (CPC), potentially suitable for vertebroplasty and kyphoplasty of osteoporotic vertebral fractures, may be required to counteract augmented local bone catabolism and to support complete bone regeneration. The biologically optimized GDF5 Mutant BB-1 may represent an attractive drug candidate for this purpose.
PURPOSE: The aim of the current study was to test an injectable, poly (l-lactide-co-glycolide) acid (PLGA) fiber-reinforced, brushite-forming CPC containing low-dose BB-1 in a sheep lumbar osteopenia model.
STUDY DESIGN/ SETTING: This is a prospective experimental animal study.
METHODS: Bone defects (diameter 5 mm) were generated in aged, osteopenic female sheep and were filled with fiber-reinforced CPC alone (L4; CPC+fibers) or with CPC containing different dosages.