Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (495)
- Vortrag (338)
- Posterpräsentation (206)
- Forschungsdatensatz (11)
- Sonstiges (9)
- Beitrag zu einem Tagungsband (7)
- Preprint (6)
- Buchkapitel (4)
- Dissertation (4)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
- Forschungsbericht (2)
- Handbuch (1)
- Newsletter (1)
Sprache
- Englisch (1086) (entfernen)
Schlagworte
- Fluorescence (106)
- Quantum yield (71)
- Nanoparticle (53)
- Quality assurance (52)
- ICP-MS (48)
- Laser ablation (47)
- Dye (46)
- Nano (43)
- Lifetime (42)
- LIBS (41)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (1086) (entfernen)
Paper des Monats
- ja (13)
The processes of hydrogen reduction of silicon and germanium chlorides under the conditions of radio-frequency (40.68 MHz) counteracted arc discharge stabilized between two rod electrodes were investigated. The main gas-phase and solid products of plasma-chemical transformations were determined.
Thermodynamic analysis of SiCl4 + H2 and GeCl4 + H2 systems was carried out. It is shown that under the implemented experimental conditions, equilibrium components of the products are established. The detected spectra of chemical activity were studied, which gave reason to assume that the molecular mechanism of the hydrogen reduction process is the main one. The impurity composition of gas-phase and solid reaction products was investigated. The possibility of single-stage production of high-purity Si and Ge mainly in the form of compact ingots, as well as high-purity chlorosilanes and trichlorogermane, was shown.
Ergot alkaloids are a group of toxic compounds, formed by fungi on infested grasses. In 2022, the European Commission set into effect maximum levels for the sum of the twelve major ergot alkaloids in multiple foods. To facilitate the laborious and costly individual quantification of the twelve major ergot alkaloids by HPLC–MS/MS or -FLD, we recently reported a sum parameter method (SPM) for ergot alkaloid quantification. Here, derivatization to lysergic acid hydrazide—a derivative of the mutual ergoline backbone in all ergot alkaloids—allowed simplified determination of all ergot alkaloids in flour via HPLC-FLD. For the measurement of more complex matrices like processed foods, we now developed a MS/MS-based SPM. Two internal standards (IS), isotopically labelled at different positions of the molecule, were synthesized and employed in the MS/MS-measurements. Method performance using either the 13CD3-labelled or the 15N2-labelled IS was evaluated on naturally contaminated rye and wheat flour samples as well as on processed food matrices. Employing the 13CD3-labelled IS leads to lower variances and better consistency with the reference data (obtained by the FLD-based SPM) in flour samples compared to the 15N2-labelled IS. The novel method significantly improves the measurement of ergot alkaloids in complex food matrices, due to their increased selectivity and thus lower interferences. Furthermore, the application of isotope labelled IS obviates the need for time-consuming steps like the determination of recovery rate based, matrix specific correction factors as described in the MS/MS-based European standard method for ergot alkaloid quantification (EN 17425).
Research into new sources for EUV lithography is driving advancements in experimental methods tailored for this short wavelength range. This progress enables the exploration of spectroscopic techniques aimed at monitoring electronic transitions within this energy spectrum. Laser-induced breakdown spectroscopy (LIBS) serves as a rapid tool for elemental analysis, primarily established in the UV-vis range. However, LIBS encounters challenges such as limited repeatability precision and elevated background noise resulting from continuum radiation.
In parallel, laser-induced extreme UV spectroscopy (LIXS) delves into the initial stages of plasma evolution, characterized by the emergence of soft X-ray and extreme UV radiation. The method benefits from a fast timeframe and constrained plasma confinement, leading to better precision. Nevertheless, LIXS encounters convoluted spectra arising from unresolved transition arrays (UTA), particularly pronounced for heavier elements. This complexity renders conventional univariate data analysis impractical, demanding the adoption of a multivariate data analysis approach.
Multiple cathode samples, each coated with varying stoichiometries of lithium nickel manganese cobalt oxide (NMC), were prepared and used for calibration purposes. Through the application of Partial Least Squares (PLS) regression, a robust correlation with an R2 value exceeding 0.97 was achieved. The LIXS technique underwent a comparative evaluation against UV-vis LIBS. Furthermore, a comparison between univariate and multivariate analysis approaches was conducted, incorporating validation through y-randomization to mitigate overfitting risks.
The viability of this approach was confirmed through the testing of an NMC reference material. The results showed metrological compatibility with reference values, underscoring the potential capability of the proposed methodology.
Gold-based nanoparticles below 2 nm in size are promising as luminescent probes for in vivo bioimaging, owing to their brightness and rapid renal clearance. However, their use as contrast agents in the near-infrared II (NIR-II, 1000–1700 nm) range remains challenging due to their low photoluminescence (PL) quantum yield. To address this, PL enhancement can be achieved by either rigidifying the ligand-shell structure or increasing the size of the ligand shell. In this study, we synthesized ultra-small gold nanoparticles stabilized by co-ligands, namely monothiol and short dithiol molecules. By precisely controlling the amount of reducing agent used during particle preparation, we successfully modulated the physicochemical properties of the co-ligand shell, including its size, composition, and structure. Consequently, we achieved a remarkable 60-fold increase in the absorption cross-section at 990 nm while maintaining the small size of the 1.5-nm metal core. The analytical and optical characterization of our thiol-capped gold nanoparticles indicates that the ligand shell size is governed by the quantity of the reducing agent, which, in turn, impacts the balance between radiative and non-radiative processes, thereby influencing the PL quantum yield.
Tailor-made nanoparticles are of increasing interest in e.g. catalysis, as sensor materials, analytical assays, or can have superior photophysical properties. A major issue concerning the preparation of high-quality and functional nanoparticles is a good control of particle size, shape, polydispersity, and composition.
Small Angle X-ray Scattering (SAXS) is a non-destructive method for the analysis of nanostructures in a wide variety of materials. This method allows determining averaged structural parameters on a length scale from just above atomic sizes up to several 100 nanometers such as sizes, size distributions, volume fractions, and inner surface sizes. Moreover, anomalous Small Angle X-ray Scattering (ASAXS) exploits the anomalous dispersion of the scattering amplitudes near the X-ray absorption edges of the elements contained in the sample. These element sensitive contrast variations can be used to analyse average composition fluctuations on the nm scale. Two kinds of nanoparticles are chosen here to elaborate the advantages of ASAXS in the analysis of complex materials.
A facile and efficient methodology is developed for the thermal synthesis of size-tunable, stable, and uniform bimetallic NiCu core–shell nanoparticles (NPs) for various application in catalysis. Their diameter can be tuned in a range from 6 nm to 30 nm and the Ni:Cu ratio is adjustable in a wide range from 1:1 to 30:1. The NPs are structurally characterized by a method combination of transmission electron microscopy, anomalous small-angle X-ray scattering (ASAXS), X-ray absorption fine structure, and X-ray photoelectron spectroscopy. Here, we focus on the ASAXS method and its ability to analyses nanostructure parts and their compositions at once. As a result, a NiCu alloyed core surrounded by a Ni enriched shell and an outer NiO shell was found.
Semiconductor nanocrystals (quantum dots, QDs) are well known for their superior photophysical properties and enabled advancements in several key technologies of the 21st century and numerous technological applications like in photovoltaics, LED displays, photocatalysis, and biosensing. To achieve high photoluminescence quantum yields (PLQY) and enhanced photostability the QD core needs to be passivated by a second semiconductor, which possess a larger band gap to confine the charges within the QD core. An important parameter is thereby the lattice mismatch between the core and shell. To avoid strong lattice strain, which would alter the photophysical properties, an intermediary shell can be used as a lattice adapter between the core and the outer shell leading to core/shell/shell systems. These systems have shown to possess high PLQYs combined with a strong long-term stability and can be found in modern QLED displays. ASAXS was used here to better understand the core/shell/shell structure of InP/ZnSe/ZnS QDs to enable a correlation between their structural and photophysical properties.
Laser breakdown spectroscopy (LIBS) is a common tool for applications in various fields of science and technology. Originally an atomic analysis technique, LIBS was later extended to molecular analysis due to the transient nature of the laser-induced plasma, which develops from a hot dissociation stage on a nanosecond to several microsecond scale to a relatively cold recombination stage on a scale of 10 to 100 microseconds after breakdown. Molecules formed during the recombination stage or incompletely dissociated after ablation can be efficiently detected, allowing the analysis of "difficult" elements or even molecular isotopes. However, with a small amount of ablated material and a short lifetime of the luminous plasma, analytical signals, especially molecular ones, can be very weak.
Several methods have been proposed for reheating the plasma and increasing its lifetime, for example, a two-pulse LIBS or a LIBS combined with microwave radiation or with an electric spark discharge. Here we propose another one, LIBS combined with a capacitively coupled RF discharge at 13.6 MHz. The advantages of this combination are an increase in the lifetime of atomic and molecular emission and operation in a low-pressure atmosphere, which significantly reduces pressure line broadening and allows high-resolution spectroscopy. Another major advantage is operating in a chemically controlled atmosphere that can predictably drive desired chemical reactions. In this presentation, we will show the first results obtained with RF-LIBS combination. These will include separate and joint characterization of LIBS and RF plasmas and evaluation of its potential for elemental and molecular analysis and for plasma enhanced chemical vapor deposition.
Many applications of LIBS require the measurement of plasma temperature and electron density, which in turn requires knowledge of the integrated line intensity and the shape of the spectral lines. While the integral intensity is preserved as light passes through the spectrometer, the shape emitted by an individual atom or ion is greatly distorted. This is due, firstly, to the transfer of light through the plasma (self-absorption), secondly, to the influence of the instrumental function of the spectrometer, and, thirdly, to the aberrations of the optical system. In addition, processing of spectral information, such as background removal, noise reduction, deconvolution, and line fitting, introduces additional errors in the reconstructed linewidth and line integral, which leads to erroneous temperature and electron density values.
This communication will be devoted to the general shortcomings of spectral data processing and the resulting inaccuracies in determining the plasma parameters. The analysis is based on the use of synthetic spectra generated by plasma with known temperature and particle density. The estimation of errors caused by inadequate processing of the spectral data is made by comparing the initial and determined plasma parameters. As a result, an improved data processing method will be proposed that takes into account the spectrum distortion by the instrumental function and integration on the pixel detector. The former is accounted for by convolution (instead of deconvolution) of the estimated line profile using a predetermined slit function, and the latter is achieved by piecewise integration of the line profile by the pixel detector, taking into account the pixel size and uniform or non-uniform pixel separation. Recommendations will be made for which analytic function best approximates the observed spectral lines and examples will be given for the application of this routine to calibration-free LIBS using both synthetic and experimental data.
In the LIBS literature, almost every second article reports the determination of the plasma temperature using the Boltzmann plot method or the determination of the electron density using the Stark line broadening relation. The first requires the measurement of the integrated intensities of the spectral lines, and the second requires the measurement of the linewidth, under the same assumption of optical thinness. It is taken for granted that this can be easily done either by working with the raw spectra or by fitting an appropriate function to the observed spectral lines. As a rule, reported data are not verified either by an alternative method (e.g., Thomson scattering) or by computer simulations using synthetic spectra.
However, the question of how to extract the necessary information from the raw spectral data is not as simple as it might seem. The quality of such an extraction will depend critically on the type of spectral instrument used, its resolution, and the noise superimposed on the data. The problem is that we do not see the spectrum emitted by the plasma, but the spectrum distorted by the measurement; an exaggerated example of such a distortion is shown in Fig. 1. The elimination of this distortion belongs to the class of inverse problems, the so-called ill-posed problems, whose successful solution crucially depends on the quality of the information available. When it comes to spectroscopy, quality of information primarily means high spectral resolution and low noise. Not all spectrometers used in LIBS can provide the quality needed to solve the inverse problem; this casts doubt on many published plasma measurements.
The current presentation will be devoted to general shortcomings in the processing of spectral data and inaccuracies in the determination of plasma parameters resulting from these shortcomings. The analysis is based on the use of synthetic spectra produced by plasma with known characteristics, i.e., temperature, species densities, and electron density. The estimation of errors caused by inadequate processing of spectral data is made by comparing the initial and reconstructed plasma parameters. Recipes will be given for which the analytic function best approximates the observed spectral lines, and how data processing errors affect accuracy of calibration-free LIBS will be discussed. These issues were only partially covered in previously published works, for example [1, 2, 3].
The aim of the project is to develop an adequate model of laser induced plasma for conditions expected in space missions, i.e., vacuum, or low-pressure CO2 atmosphere. Numerical modeling will help to find optimal experimental parameters for the laser ablation under artificial lunar or Martian environments and obtain both qualitative, in terms of a composition, and quantitative, in terms of an elemental abundance, information about interrogated samples based on spectral data generated by the model. The best operational conditions will be found at a low cost without conducting tedious and time-consuming optimization experiments. The modeling approaches will be supported by machine learning to accelerate the optimization.
The application of multivariate data analysis is essential in extracting the full potential of laser-induced XUV spectroscopy (LIXS) for high-precision elemental mapping. LIXS offers significant advantages over traditional laser-induced breakdown spectroscopy in UV-vis (LIBS), including higher precision and a wider dynamic range,[1,2] while making it possible to determine light elements like lithium and fluorine. However, it is challenged by the presence of unresolved transition arrays (UTAs) for heavier elements. These UTAs add considerable complexity to the spectral data, often concealing crucial information. In this study, we employ well-established multivariate data analysis techniques and intensive data preprocessing to unravel this contained information.
The refined analysis reveals a high level of detail, enabling the precise identification of inhomogeneities within material samples. Our approach has particular relevance for studying aging processes in lithium-ion batteries (LIBs), specifically in relation to varying cathode materials and fluorine-containing polymer binder content. By combining elemental distribution with structural information, this improved method can offer a more comprehensive understanding of sample inhomogeneities and aging processes in LIBs, contributing to the development of more reliable and sustainable battery technologies.