Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Vortrag (287)
- Zeitschriftenartikel (243)
- Beitrag zu einem Tagungsband (130)
- Posterpräsentation (69)
- Forschungsdatensatz (15)
- Buchkapitel (10)
- Dissertation (7)
- Sonstiges (5)
- Beitrag zu einem Sammelband (3)
- Preprint (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
- Forschungsbericht (1)
Sprache
- Englisch (775) (entfernen)
Schlagworte
- Concrete (85)
- Ultrasound (70)
- NDT (60)
- Non-destructive testing (60)
- Thermography (48)
- LIBS (46)
- Additive manufacturing (35)
- Computed tomography (28)
- Super resolution (28)
- Nondestructive testing (27)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (775) (entfernen)
Paper des Monats
- ja (6)
Eingeladener Vortrag
- nein (287)
In the last twenty years, components made of fibre-reinforced plastic became a prominently used material in safety-relevant structures. Periodic in-service inspection of these structures using reliable non-destructive testing methods became a relevant issue in the field. The goal of the EMRP-funded project VITCEA (Validated Inspection Techniques for Composites in Energy Applications) aims on the evaluation of the performance of various non-destructive testing methods on the inspection of fibre-reinforced plastics.
In this talk the results of the comparison of different ultrasonic testing methods will be discussed. There are two challenges for the ultrasonic inspection of fibre-reinforced plastics. Firstly, different material properties of the fibre and the resin cause anisotropic acoustical behaviour of the material. Secondly, the physical layout of fibre layers leads to complex structures of fibre-reinforced plastic parts, and thus to a complex acoustical response. Both result in a reduction of the signal to noise ratio and make interpretation of measurement results rather extensive.
During the VITCEA project, the acoustical behaviour of fibre-reinforced plate materials has been simulated. Specimens with artificial flaws for the evaluation of the detection thresholds have been designed and manufactured.
Various mechanized ultrasonic testing methods including phased-array sensors, air-coupled transducers, immersion tank testing and contact technique have been evaluated on the specially designed specimen. Laboratory scale tests and a round robin test have been carried out. The probability of detection and the detection thresholds for each method have been estimated.
Compared to standard ultrasonic testing methods the application of phased arrays offers advantages and flexibility by the electronic steering possibilities to control the transmitted and received sound fields as well as the image based evaluation of the recorded scans. For more than one decade phased array systems have been introduced and used in the railway sector for the inspection of wheelsets in the workshops. Up to the present field applications of phased array systems in rail inspection are rather rare. On the other hand a lot of scientific work on rail testing using phased arrays has been carried out in the recent past.
Mechanized ultrasonic rail inspection poses strong challenges e.g. due to the harsh environment, complex flaw types and high inspection speeds. Different tasks have to be carried out by non-destructive testing ranging from manufacturing inspection of thermite welds to in-service inspection for operational induced flaws in the rail head, rail web and rail foot as well as rolling contact fatigue. This work will give an overview and categorization of different present approaches for rail testing using phased array.
Phased array systems typically offer digital image based inspection results. This make these systems become the perfect candidates to feed inspection data into a modern big data based workflow, using e.g. cloud computing, signal processing and data fusion for recording, positioning and tracking of flaws and artefacts in rails and to gain additional benefit.
Evaluation of promising innovative approaches and solutions for phased array based ultrasonic rail inspection in the frame of “Industry 4.0” will be discussed.
Increased use of high performance steel (HPS) for demanding applications calls for non-destructive ultrasonic testing methods which is covered by standards like SEP 1927 (1) and ASTM E588 (2). Here, an adaption of standards like increasing sensitivity and resolution of ultrasonic testing may be needed in order to improve determination of steel cleanliness.
Modern requirements on standardization in that field have been evaluated during the INCAFAT project “A novel approach for rating fatigue-initiating inclusions in highly demanding steel” which was funded by the European Commission.
Main results of this research show that an adapted standard should be open to different type of specimen due to the diversity in application. This includes a wide range from bars, rings and plates as well as different inspection sensitivities. An adapted standard should be open to the definition of the volume to be investigated and open to be selected by the user. Furthermore, for enhanced resolution the frequency range should be extended to higher frequencies. The use of focal beam probes shall be mandatory and probes should be selected according to the geometry of the specimen. Therefore, calibration procedures have to be improved significantly to allow proper sizing of indications. Indication height shall be directly transferred into an equivalent disc shaped reflector taking distance amplitude curves as well as signal amplitude distribution and signal travel time into account.
A new standard draft proposal taking all these requirements into account has been filed in the frame of the INCAFAT project and is now on discussion.
We report on photothermal detection of subsurface defects by coherent superposition of thermal wave fields. This is made possible by structured heating using high-power VCSEL laser arrays whose individual emitter groups can be arbitrarily controlled. In order to locate the defects, we have developed a scanning method based on the continuous wavelet transformation with complex Morlet wavelet using the destructive interference effect of thermal waves. This approach can also be used for thermally very fast and highly reflective materials such as uncoated aluminum. We show that subsurface defects at an aspect ratio of defect width to defect depth down to 1/3 are still detectable in this material.
Although concrete itself is not a combustible material, concrete mixtures with high density, such has high-performance concretes (HPCs), are susceptible to significant damage during fires due to explosive spalling. Past research has shown that the inclusion of polymer fibres in high density concrete can significantly mitigate this fire damage. The exact mechanisms causing this increased spalling resistance are not yet fully under-stood, but it is thought that the fibres facilitate moisture transport during fire exposure, which in turn contributes to relief of internal stresses in the spalling-susceptible region. In this study, X-ray Computed Tomography (CT) was applied to observe the interaction between polymer fibres and cracking during thermal exposure. For this purpose, two concrete samples containing different polymer fibre types were subjected to incremental application of a defined thermal exposure. CT images were acquired before and after each thermal exposure and powerful image processing tools were used to segment the various material components. This enabled a detailed analysis of crack formation and propagation as well as the visualization and quantification of polymer fibre characteristics within the concrete. The results demonstrated that the orientation of both fibres and cracks in polymer-fibre reinforced concrete tend to be anisotropic. The results also indicated that crack geometry characteristics may be correlated with fibre orientation, with cracks tending to run parallel to fibre beds. Clear quantitative relationships were also observed between heating and increasing cracking levels, expressed in terms of both crack surface area and crack volume.
The book chapter first analyses the history of higher education in Europe. Second step describes the current Bologna process. Finally, the rule of the Bundesanstalt für Materialforschung und -Prüfung (BAM) in supporting PhD-students during their research and preparation of theire theses in cooperation with Universities is described
Recent developments of photon counting and energy discriminating detectors for radiographic imaging
(2018)
The direct detection of X-ray photons into electrical signals is enabled by usage of highly absorbing photo conducting materials (e.g. CdTe) as detection layer of an underlying CMOS semiconductor X-ray image detector. If the read-out speed is high enough (ca. 50 - 100 ns dead time) single X-ray photons can be counted and their energy measured. Read-out noise and dark image correction can be diminished. By setting energy thresholds, selected energy ranges of the X-ray spectrum can be detected or suppressed. This allows material discrimination or reduction of scattered radiation, which results in an enhanced contrast sensitivity.
The presented development of a damping model is a research component of an experimental feasibility study about moisture in building materials measured with Bluetooth® Low Energy (BLE) signals. This study may be part of a structural health- and long-term monitoring aiming at early damage detection in the built infrastructure and is increasingly focusing on wireless sensor network technology. It is investigated, how the Received Signal Strength Indicator (RSSI) of a BLE signal, transmitted from the BLE-module embedded in building materials with changing moisture content is damped. The aim of the modelling is the derivation of a damping equation for the formal model to determine the moisture damping exponent to finding a correlation.
Data fusion for multi-sensor nondestructive detection of surface cracks in ferromagnetic materials
(2018)
Fatigue cracking is a dangerous and cost-intensive phenomenon that requires early detection. But at high test sensitivity, the abundance of false indications limits the reliability of conventional materials testing. This thesis exploits the diversity of physical principles that different nondestructive surface inspection methods offer, by applying data fusion techniques to increase the reliability of defect detection. The first main contribution are novel approaches for the fusion of NDT images. These surface scans are obtained from state-of-the-art inspection procedures in Eddy Current Testing, Thermal Testing and Magnetic Flux Leakage Testing. The implemented image fusion strategy demonstrates that simple algebraic fusion rules are sufficient for high performance, given adequate signal normalization. Data fusion reduces the rate of false positives is reduced by a factor of six over the best individual sensor at a 10 μm deep groove. Moreover, the utility of state-of-the-art image representations, like the Shearlet domain, are explored. However, the theoretical advantages of such directional transforms are not attained in practice with the given data. Nevertheless, the benefit of fusion over single-sensor inspection is confirmed a second time. Furthermore, this work proposes novel techniques for fusion at a high level of signal abstraction. A kernel-based approach is introduced to integrate spatially scattered detection hypotheses. This method explicitly deals with registration errors that are unavoidable in practice. Surface discontinuities as shallow as 30 μm are reliably found by fusion, whereas the best individual sensor requires depths of 40–50 μm for successful detection. The experiment is replicated on a similar second test specimen. Practical guidelines are given at the end of the thesis, and the need for a data sharing initiative is stressed to promote future research on this topic.
The relevance of chloride measurements in practice for durability condition assessment and a description of the working principle of LIBS will be given. A comparison of chloride profiles obtained by the common wet chemical analysis and results from LIBS measurements are shown to demonstrate the accuracy of the LIBS-technique. In addition, an example on the extra information resulting from measurements performed with LIBS for improvement of condition assessment and prediction will be shown.