Chemie und Prozesstechnik
Filtern
Erscheinungsjahr
- 2022 (456) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (163)
- Vortrag (149)
- Posterpräsentation (67)
- Beitrag zu einem Tagungsband (36)
- Forschungsbericht (15)
- Forschungsdatensatz (10)
- Sonstiges (5)
- Buchkapitel (3)
- Dissertation (2)
- Video (2)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
- Preprint (2)
Sprache
- Englisch (456) (entfernen)
Schlagworte
- Digitalization (21)
- Certification (19)
- Conformity assessment (19)
- Fluorescence (19)
- Digital transformation (18)
- COVID-19 (17)
- Calibration (17)
- Conformity assessment body (17)
- Non-destructive testing (17)
- Quality infrastructure (17)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (165)
- 8 Zerstörungsfreie Prüfung (150)
- 6 Materialchemie (106)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (49)
- 1.1 Anorganische Spurenanalytik (44)
- 6.1 Oberflächen- und Dünnschichtanalyse (42)
- 8.5 Röntgenbildgebung (41)
- 6.3 Strukturanalytik (40)
- 1.2 Biophotonik (35)
- 8.4 Akustische und elektromagnetische Verfahren (32)
Paper des Monats
- ja (2)
Safe food is a prerequisite for good human health, however currently almost one in ten people in the world fall ill after eating contaminated food. National food safety authorities need to be able to manage food safety risks along the entire food chain. The Official Controls Regulation (EU) 2017/625 was put in place to ensure that food and feed law stipulates the need for validated analytical methods. However, whilst method development for food control and proficiency testing are well established by European Union Reference Laboratories and National Reference Laboratories, validation of the measurements involved, certified reference materials and internationally recognised calibration and measurement capabilities are currently often (?) lacking. This may erode trust in the accuracy of the measurements.
This poster presents Food-MetNet, a coordinated preparatory initiative to establish the European Metrology Network for Safe and Sustainable Food, recently approved by the European Association of National Metrology Institutes (EURAMET). Food-MetNet aims to establish an ongoing dialogue between the metrology community, reference laboratories and regulatory bodies, in order to (i) identify stakeholders’ needs, (ii) develop a sustainable knowledge-sharing programme and web-based platform for stakeholders and (iii) develop roadmaps and a strategic research agenda. Improved access to more reliable and accurate food safety measurements will enable reference laboratories to more confidently and effectively compare their measurement results and support accreditation. This is particularly important where national food safety authorities need to assess potential new contaminants, novel food ingredients and newly emerging food risks, and new measurements methods may be required as well as input into new documentary standards. The activities for sustainable food intend to boost the activity within the "EU green deal framework" to reduce food waste and losses, and the development of standards and methods that allow for the reuse of food waste. The support to new business opportunities and innovation will allow increasing the market competitiveness of EU food industries and the valorisation of waste by reducing environmental impacts.
The most profound consequences of the presence of Ca–Mg carbonates (CaCO3–MgCO3) in the Earth’s upper mantle may be to lower the melting temperatures of the mantle and control the melt composition.
Low-degree partial melting of a carbonate-bearing mantle produces CO2-rich, silica-poor melts compositionally imposed by the melting relations of carbonates. Thus, understanding the melting relations in the CaCO3–MgCO3 system facilitates the interpretation of natural carbonate-bearing silicate systems.
We report the melting relations of the CaCO3–MgCO3 system and the partition coefficient of trace elements between carbonates and carbonate melt from experiments at high pressure (6 and 9 GPa) and temperature (1300–1800 ◦C) using a rocking multi-anvil press. In the absence of water, Ca–Mg carbonates are stable along geothermal gradients typical of subducting slabs. Ca–Mg carbonates (∼ Mg0.1–0.9Ca0.9–0.1CO3) partially melt beneath mid-ocean ridges and in plume settings. Ca–Mg carbonates melt incongruently, forming periclase crystals and carbonate melt between 4 and 9 GPa. Furthermore, we show that the rare earth element (REE) signature of Group-I kimberlites, namely strong REE fractionation and depletion of heavy REE relative to the primitive mantle, is resembled by carbonate melt in equilibrium with Ca-bearing magnesite and periclase at 6 and 9 GPa. This suggests that the dolomite–magnesite join of the CaCO3–MgCO3 system might be useful to approximate the REE signature of carbonate-rich melts parental to kimberlites.
X-ray refraction is an excellent tool for the characterization of the microstructure of materials. However, there are only a few (synchrotron) laboratories in the world that use this technique for material characterisation. Therefore, the seminar will first explain the basic principles of X-ray refraction and the measurement techniques installed at the hard X-ray beamline BAMline at BESSY II (Berlin, Germany). This is followed by examples of investigations on fibre-reinforced plastic composites (CFRP) as well as ceramic (Cordierite, ZrO2-SiO2) and metallic materials (Ti-6Al-4V, Inconel). Some of the investigations were carried out both ex-situ and in-situ under mechanical and thermal load. The results are correlated with the mechanical properties of the materials.
Hybrid optical measurement technique for detection of defects in epitaxially grown 4H-SiC layers
(2022)
Recent developments in power electronics require the use of new wide bandgap compound semiconductor. We demonstrate the use of the ellipsometry and white light interference microscopy to detect defects in epitaxially grown SiC layers on SiC substrates. Such hybrid optical metrology methods can be used to better understand the mechanism of the development of the defects as well as their effects on the material´s optoelectronic properties.
The availability of high-performance Al alloys in AM is limited due to difficulties in printability, requiring both the development of synergetic material and AM process to mitigate problems such as solidification cracking during laser powder bed fusion (LPBF). The goal of this work was to investigate the failure mechanism in a LPBF 7017 Aluminium alloy + 3 wt% Zr + 0.5 wt% TiC. The processing leads to different categories of Zr-rich inclusions, precipitates and defects.
In this study, we employed nitrogen microwave inductively coupled atmospheric-pressure plasma (MICAP) combined with quadrupole mass spectrometry (MS) and a liquid sample introduction system to analyze heavy metals in soils. The vanadium, cobalt, nickel, zinc, copper, chromium, arsenic, lead, and cadmium contents in seven reference and three environmental soil samples determined using MICAP-MS were within the uncertainty of the reference values, indicating that MICAP-MS is promising for soil analysis similar to the conventional inductively coupled plasma mass spectrometry (ICP-MS) technique. In addition, the limits of detection (LODs) and sensitivity of both techniques using N2 and Ar plasma were of the same order of magnitude. Furthermore, the performance of MICAP-MS under different N2 purity was investigated, and we found that the plasma formation and ionization efficiency were not influenced by the impurities in the gas. A prominent advantage of MICAP-MS is the low operating cost associated with gas consumption. In this work, MICAP-MS used nitrogen, which is cheaper than argon, and consumed 25% less gas than ICP-MS. Using low-purity N2 can further reduce the gas cost, making MICAP-MS more cost effective than ICP-MS. These results suggest that MICAP-MS is a promising alternative to ICP-MS for the analysis of heavy metals in the soil.
The use of renewable energy sources, electromobility, and portable
electronics relies on lithium-ion batteries (LIBs). However, one
detrimental effect, which can result in significant performance loss,
is the corrosion of the current collectors caused by the aging
mechanisms, especially in high-energy-density batteries
Glow discharge optical emission spectroscopy (GD-OES) provides
depth profile analysis through sputtering using argon plasma, which
enables the analysis of the corrosion behavior at different depths of
the cathodes.
In the present talk the basics of the Raman spectroscopy and particularly of Raman microscopy are explained. Advantages and disadvantages of the method are highlighted through selected case studies. In the second part of the lecture examples of correlative imaging with electron, X-ray, ion and optical microscopies from micro- to the nanoscale are highlighted.
ADAMTS4-specific MR-probe to assess aortic aneurysms in vivo using synthetic peptide libraries
(2022)
The incidence of abdominal aortic aneurysms (AAAs) has substantially increased during the last 20 years and their rupture remains the third most common cause of sudden death in the cardiovascular field after myocardial infarction and stroke. The only established clinical parameter to assess AAAs is based on the aneurysm size. Novel biomarkers are needed to improve the assessment of the risk of rupture. ADAMTS4 (A Disintegrin And Metalloproteinase with ThromboSpondin motifs 4) is a strongly upregulated proteoglycan cleaving enzyme in the unstable course of AAAs. In the screening of a one-bead-one-compound library against ADAMTS4, a low-molecular-weight cyclic peptide is discovered with favorable properties for in vivo molecular magnetic resonance imaging applications. After identification and characterization, it’s potential is evaluated in an AAA mouse model. The ADAMTS4-specific probe enables the in vivo imaging-based prediction of aneurysm expansion and rupture.
The rising popularity of additive manufacturing processes leads to an increased interest in possibilities and methods for related process monitoring. Such methods ensure improved process quality and increase the understanding of the manufacturing process, which in turn is the basis for stable component quality, e.g., required in the aerospace industry or in the medical sector. For laser powder bed fusion, a handful of process monitoring tools already exist, such as optical tomography, thermography, pyrometry, imaging, or laser power monitoring. Although these tools provide helpful information about the process, more information is required for an accurate in-depth understanding. In this article, advanced approaches in eddy current testing (ET) are combined, such as single wire excitation, magnetoresistive (MR) sensor arrays, and heterodyning to build up a system that can be used for online process monitoring of laser powder bed fusion. In addition to detailed information about the developed ET system and underlying signal processing, the first results of magnetoresistance-basedonline ET during the laser powder fusion process are presented. While producing a step-shaped cuboid, each layer is tested during recoating.
Test results show that not only the contours of the topmost layer are detected but also the contours of previous layers covered by powder. At an excitation frequency of 1 MHz, a penetration depth of approx. 400 μm is obtained. To highlight the possibilities of ET for online process monitoring of laser powder bed fusion, results are compared with postexposure images of the integrated layer control system (LCS).