Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Vortrag (1069) (entfernen)
Sprache
- Englisch (1069) (entfernen)
Referierte Publikation
- nein (1069)
Schlagworte
- Concrete (39)
- LIBS (36)
- Nanoparticles (32)
- NDT (30)
- Fluorescence (28)
- Traceability (25)
- Synchrotron (24)
- Additive manufacturing (23)
- X-ray scattering (23)
- Metrology (22)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (339)
- 6 Materialchemie (339)
- 8 Zerstörungsfreie Prüfung (287)
- 6.1 Oberflächen- und Dünnschichtanalyse (122)
- 1.1 Anorganische Spurenanalytik (99)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (88)
- 8.0 Abteilungsleitung und andere (87)
- 6.3 Strukturanalytik (84)
- 4 Material und Umwelt (70)
- 1.4 Prozessanalytik (61)
- 8.5 Röntgenbildgebung (58)
- 6.6 Physik und chemische Analytik der Polymere (57)
- 8.4 Akustische und elektromagnetische Verfahren (57)
- 1.2 Biophotonik (55)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (50)
- 1.6 Anorganische Referenzmaterialien (48)
- S Qualitätsinfrastruktur (41)
- 6.7 Materialsynthese und Design (39)
- 1.9 Chemische und optische Sensorik (33)
- S.2 Digitalisierung der Qualitätsinfrastruktur (33)
- 4.5 Kunst- und Kulturgutanalyse (32)
- 1.8 Umweltanalytik (27)
- 1.3 Instrumentelle Analytik (26)
- 5 Werkstofftechnik (25)
- 7 Bauwerkssicherheit (19)
- 9 Komponentensicherheit (18)
- 1.7 Organische Spuren- und Lebensmittelanalytik (15)
- 4.2 Material-Mikrobiom Wechselwirkungen (14)
- 4.3 Schadstofftransfer und Umwelttechnologien (14)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (12)
- 9.0 Abteilungsleitung und andere (12)
- 4.1 Biologische Materialschädigung und Referenzorganismen (11)
- 6.2 Material- und Oberflächentechnologien (11)
- P Präsident (10)
- P.0 Präsident und andere (10)
- VP Vizepräsident (8)
- VP.1 eScience (8)
- 2 Prozess- und Anlagensicherheit (7)
- 3 Gefahrgutumschließungen; Energiespeicher (7)
- 5.1 Mikrostruktur Design und Degradation (7)
- 6.0 Abteilungsleitung und andere (7)
- S.1 Qualität im Prüfwesen (7)
- 7.4 Baustofftechnologie (6)
- 8.6 Faseroptische Sensorik (6)
- 9.4 Integrität von Schweißverbindungen (6)
- 5.0 Abteilungsleitung und andere (5)
- 5.2 Metallische Hochtemperaturwerkstoffe (5)
- 5.4 Multimateriale Fertigungsprozesse (5)
- 7.6 Korrosion und Korrosionsschutz (5)
- 1.0 Abteilungsleitung und andere (4)
- 2.1 Sicherheit von Energieträgern (4)
- 7.1 Baustoffe (4)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (3)
- 3.2 Gefahrguttanks und Unfallmechanik (3)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (3)
- 7.0 Abteilungsleitung und andere (3)
- 9.6 Additive Fertigung metallischer Komponenten (3)
- 1.5 Proteinanalytik (2)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 9.2 Versuchsanlagen und Prüftechnik (2)
- 9.5 Tribologie und Verschleißschutz (2)
- 2.0 Abteilungsleitung und andere (1)
- 3.6 Elektrochemische Energiematerialien (1)
- 4.0 Abteilungsleitung und andere (1)
- 5.5 Materialmodellierung (1)
- 5.6 Glas (1)
- 7.2 Ingenieurbau (1)
- 7.3 Brandingenieurwesen (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
- PST Präsidiale Stabsstelle (1)
- S.0 Abteilungsleitung und andere (1)
- VP.2 Informationstechnik (1)
From simple molar mass disperse homopolymers over copolymers to functionalized, 3-dimensional structures containing various distributions, the complexity of polymeric materials has become more and more sophisticated in recent years. With applications in medicine, pharmacy, smart materials or for the semiconductor industry the requirements for the characterization have risen with the complexity of the used polymers. For each additional distribution, an additional dimension in analysis is needed. Small, often isobaric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector. Instead of a complicated, time consuming and/or expensive 2d-chromatography or ion mobility spectrometry (IMS) method, that also has its limitations, here a simple approach using size exclusion chromatography (SEC) coupled with electrospray ionization mass spectrometry (ESI) is proposed. We used SEC for the separation because unlike other separation modes the separation in this mode solely should occur due to the hydrodynamic volume with no interference of other interactions. This simplifies the interpretation and the above mentioned heterogeneities should show a slight difference in hydrodynamic volume. ESI mass spectrometry can offer more than an access to mass dependent information like MMD, end group masses or CCD in polymer analysis. The online coupling to SEC allows the analysis of reconstructed ion chromatograms (RIC) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities in microstructure or topology, that are otherwise inaccessible or accessible only by time consuming or expensive methods. Because these heterogeneities might vary with the molar mass, analysis of the whole MMD-Peak (here the total ion current (TIC)) would not lead to the desired information. The broadening of the chromatographic peaks in this case does not origin from the already well known band broadening factors in chromatography from diffusion. This band broadening is attributed to the nature and composition of the analyte itself. Surprisingly there is very little investigation into the peak width or peak shape due to analyte structure itself found in literature. It is also shown, that with proper calibration even quantitative information could be obtained. This method is suitable to detect small differences in e. g. branching, topology, monomer sequence or tacticity and could potentially be used in production control of oligomeric products or other routinely done analyses to quickly indicate deviations from set parameters. Based on a variety of examples we demonstrate the possibilities and limitations of this approach.
We show both theoretically and experimentally how the encapsulation of the active region by additional guard layers can be used to achieve a significant reduction of the built-in electric fields in polar nitride heterostructures. This reduction of the QCSE results in a strongly enhanced emission intensity and faster recombination dynamics in the active region. In particular we are able to shift the emission energy of 4-nm-thick GaN nano-discs up to 3.32 eV, which is just 150 meV below the bulk GaN bandgap as compared to a red-shift of about 1 eV in a conventional heterostructure with the same thickness.
This is the first time that PE frits were used to quantify sulfur in copper and its alloys by isotope dilution combined with LA-ICP-MS: an alternative approach for sample preparation. The following properties of the PE frit meet the requirements for isotope dilution LA-ICPMS: porous material, thermo plastic (melting point >100°C), chemical resistance (nitric acid >70%) and high adsorption efficiency. The breakthrough, however, as a support material, especially when comparing the PE frit with other materials such gelatin or sodium silicate is the low blank, which is only two times of the gas flow blank (2.3-4.0 x 10⁴ cps). Additionally, the porosity of the frit was considered, as it directly affects the adsorption efficiency for the sample solution, which is present in the cavities of the frit.
Adsorption efficiency was studied by depositing sulfur standards with varying sulfur amounts (0, 2, 5, 10, 20, 40 and 80 µg S) on the frits. The remaining sulfur which was not absorbed by the frit was rinsed off and was measured by ICP-MS. This indirect method shows that more than 99.5 % of the loaded sulfur was absorbed by the frit. Such high absorption efficiency is completely sufficient for a support material to be used in LA-ICP-IDMS. The so prepared frits with increasing sulfur amount were measured by LA-ICP-MS showing a good linearity between 0 µg S and 40 µg S with a correlation coefficient r2 of 0.9987 and sensitivity of 3.4x10⁴ cps µgˉ¹ for 32S.
Three copper reference materials produced by BAM were selected to develop and validate the LA-ICP-IDMS procedure. The IDMS technique was applied to these samples as follows: the samples were spiked, dissolved, digested and then the digest was adsorbed on the frits.
In situ laser-induced breakdown spectroscopy measurements in stainless steels during TIG welding
(2018)
Chemical composition of the welding seam and HAZ has significant effect on weld quality. Current inspection methods for weld seams measure and investigate post factum and cannot prevent weld defects. Element burn-off may significantly affect solidification leading to embrittlement or cracking Control of weld chemical compositions insures a controlled solidification and resistance to related weld defects. A prototype of a LIBS controlled welding process is presented.
Photoelectron spectroscopy
(2018)
Grundkenntnisse zum besseren Verständnis der Funktionsweise der Elektronenstrahl-Mikroanalyse (ESMA) werden präsentiert und anhand Beispielen diskutiert.
Das physikalische Messprinzip von ESMA am REM, das Wechselwirkungs- und Informationsvolum und die Anregung der charakteristischen Röntgenlinien werden erklärt. Verschiedene potentielle Artefakte, wie z.B. Heterogenität der Probenzusammensetzung, Oberflächenbeschaffenheit der Probe und Linienüberlagerung werden eingeführt.
Die physikalischen Grenzen der analytischen Methode werden spezifiziert.