Ultrasound echo is a widely used NDT technique for determining the internal geometry of structures. Reverse-time migration (RTM) has been recently introduced to NDT applications, as an imaging method for ultrasound data, to overcome some of the limitations (e.g. imaging steeply dipping reflector) experienced by the Synthetic Aperture Focusing Technique (SAFT), the most commonly used imaging algorithm for these measurements.
The standard implementation of RTM also experiences some drawbacks caused by its imaging condition, which is based on the zero-lag of the cross-correlation between source and receiver wavefields and generates high-amplitude low-frequency artifacts. Three alternative imaging conditions, developed for seismic data applications, were tested for their ability to provide better images than the standard cross-correlation: illumination compensation, deconvolution and wavefield decomposition. A polyamide specimen was chosen for the simulation of a synthetic experiment and for real data acquisition. The migrations of both synthetic and real data were performed with the software Madagascar. The illumination imaging condition was able to reduce the low-frequency noise and had a good performance in terms of computing time. The deconvolution improved the resolution in the synthetic tests, but did not showed such benefit for the real experiments. Finally, as for the wavefield decomposition, although it presented some advantages in terms of attenuating the low-frequency noise and some unwanted reflections, it was not able to image the internal structure of the polyamide as well as the cross-correlation did. Suggestions on how to improve the cost-effectiveness of the implementation of the deconvolution and wavefield decomposition were presented, as well as possible investigations that could be carried out in the future, in order to obtain better results with those two imaging conditions.
Zahlreiche Schädigungsprozesse in Baustoffen stehen im engen Zusammenhang mit Feuchteeintrag und Feuchtetransport. Als Beispiel sind die schädigende Alkali-Kieselsäurereaktion (AKR) von Beton sowie Frost-Tauwechsel induzierte Gefügeschäden genannt. Zur zerstörungsfreien, ortsaufgelösten Feuchtemessung eignet sich die im Bereich der Geophysik etablierte, aber im Bauingenieurwesen noch wenig verbreitete, Messmethode der Nuklear Magnetischen Resonanz (NMR). Unter Verwendung der NMR-Relaxometrie sind sowohl Aussagen zum Feuchtegehalt und dessen räumliche Verteilung als auch die Charakterisierung der Porengrößen möglich, die das Transportverhalten eines porösen Materials maßgeblich beeinflussen.
Zur Erfassung der Mikro- und Mesoporen in Baustoffen ist dabei die Auflösung von kurzen T2 Relaxationszeiten unabdingbar. Bisher ist es mit gängigen NMR-Laborgeräten nur begrenzt möglich, solche kurzen T2-Zeiten schichtselektiv zu erfassen. Vor diesem Hintergrund wurde ein speziell für die Messung an mineralischen Baustoffen optimierter NMR-Tomograph beschafft. Dieser ermöglicht sowohl schichtselektive Messungen von Bohrkernen mit Durchmessern von bis zu 70 mm als auch bildgebende Untersuchungen an Proben mit Durchmessern ≤ 40 mm.
Erste Untersuchungsergebnisse an Sandstein, Tuffstein und Beton zeigen die Leistungsfähigkeit des neuen NMR-Tomographen zur Erfassung der porengrößenspezifischen Feuchteverteilung. In diesem Beitrag werden erste Ergebnisse verschiedenartiger Laborversuche exemplarisch dargestellt.
Für Sandsteine mit unterschiedlichsten Porengrößenverteilungen wurden mit dem neuen NMR-Tomographen und einem herkömmlichen NMR-System vergleichbare T2 Zeitenverteilungen ermittelt. Am sehr heterogenen Tuffstein konnten unterschiedlich poröse (und feuchte) Bereiche räumlich aufgelöst werden. Im Beton ließ sich der Feuchtetransport im Zementstein porengrößenspezifisch, schichtselektiv und zeitlich aufgelöst verfolgen.
Die bisher gewonnenen Ergebnisse zeigen das breite Anwendungsspektrum des neuen NMR Tomographen auf und ermöglichen ein besseres Verständnis des Feuchtetransports und der oft damit einhergehenden Schädigungsprozesse in Baustoffen.
Imaging of results in NDT-CE: Strength and limitations in the use of Radar vs. Ultrasonic Echo
(2022)
Presentation on behalf of the co-author specified in BAM-Publica.
Study on capabilities of volume methods (GPR, Ultrasonic Echo) regarding lateral and depth localisation of reinforcement and tendons in concrete components. Varied boundary conditions: spacing and diameter of both the near surface rebars of the mesh, and the reflectors of interest, as well as component thickness and concrete cover. Please find corresponding references on slide 2.
The non-destructive testing methods available for civil engineering (NDT-CE) enable the measurements of quantitative parameters, which realistically describe the characteristics of existing buildings. In the past, methods for quality evaluation and concepts for validation expanded into NDT-CE to improve the objectivity of measured data. Thereby, a metrological foundation was developed to collect statistically sound and structurally relevant information about the inner construction of structures without destructive interventions. More recently, the demand for recalculations of structural safety was identified. This paper summarizes a basic research study on structural analyses of bridges in combination with NDT. The aim is to use measurement data of nondestructive testing methods as stochastic quantities in static calculations. Therefore, a methodical interface between the guide to the expression of uncertainty in measurement and probabilistic approximation procedures (e.g. FORM) has been proven to be suitable. The motivation is to relate the scientific approach of the structural analysis with real information coming from existing structures and not with those found in the literature. A case study about the probabilistic bending proof of a reinforced concrete bridge with statistically verified data from ultrasonic measurements shows that the measuring results fulfil the requirements concerning precision, trueness, objectivity and reliability.
In this contribution, an approach is outlined to process non-destructively gath-ered measurement data in a comparable way in order to include the measured information in probabilistic reliability assessments of existing structures. An es-sential part is the calculation of measurement uncertainties. The effect of incor-porating evaluated NDT-results is demonstrated by means of a prestressed con-crete bridge and GPR measurements conducted on this bridge as a case-study. The bridge is assessed regarding SLS Decompression using the NDT-results.
Existing concrete structures were usually designed for lifetimes of several decades. The current and urgently required efforts to increase sustainability and protect the environment will likely result in extended service lives up to 100 years. To achieve such objectives, it is required to assess structures over their entire lifecycles. Non-destructive testing (NDT) methods can reliably support the assessment of existing structures during the construction, operational, and decommissioning phases. One of the most important and safety-relevant components of a prestressed concrete structure are the tendons. NDT methods such as the ultrasonic echo method are suitable for both the detection and the localization of the tendons, i.e., the measurement of their geometrical position inside the component. The uniqueness of structures, concrete heterogeneity, and varying amounts of secondary components such as the reinforcement represent obstacles in the application of these methods in practice. The aim of this contribution is to demonstrate a practicable procedure, that can be used in the field to determine the parameters required for the measuring data analysis without extensive knowledge about the investigated components. For this purpose, a polyamide reference specimen is used to show which steps are required to obtain reliable imaging information on the position of tendons from the measurement data. The procedure is then demonstrated on a concrete test specimen that covers various relevant and practice-oriented test scenarios, such as varying tendon depths and component thicknesses.
When reassessing existing concrete bridges, the challenge is often to obtain missing or incomplete information on the internal structure. In particular, the number and position of the existing reinforcement as well as the geometric dimensions of the components are of interest. Non-destructive testing methods, like radar or ultrasound, which work on the basis of the pulse-echo method, have been established for this purpose, as they only require access to the component from one side. The measurement data recorded on the structure require pre-processing to be able to reproduce the internal structure geometrically accurately. Besides different steps of data processing, the geometrical reconstruction of the measured data based on the Synthetic Aperture Focusing Technique (SAFT) is state of the art today. In this paper, the technical possibilities of the ultrasonic echo method are presented based on measurements in the laboratory and on a real bridge structure. The precision of the reconstruction and its limitations are shown. In addition to the state of the art SAFT technique, open questions and the latest research approaches, such as imaging by reverse time migration (RTM) including initial results are discussed.
The propagation of ultrasonic waves in concrete is affected by its micro- and macro-structure, geometry and properties as well as external influences as stress, temperature or moisture. In addition, age and degradation have a strong influence. Therefore, Ultrasound has been used to monitor concrete samples and structures since decades. However, early applications using conventional techniques as time-of flight or changes in amplitudes have been limited to detect changes in a late stage close to serviceability or ultimate load states.
Around 2000, several new, more sensitive techniques adopted from geophysics or other field of material sciences have been introduced to research in ultrasonic monitoring of concrete. The most discussed methodologies are coda wave interferometry, a technique which allows to detect very subtle changes from repeated ultrasonic measurements. Nonlinear acoustic techniques help to identify e. g. cracks even in an inhomogeneous background. Both techniques can be combined.
This paper reviews methods and results achieved so far on the laboratory scale and with full scale models the directions for future research and application is given as well.