Chemie und Prozesstechnik
Filtern
Dokumenttyp
- Vortrag (47)
- Zeitschriftenartikel (24)
- Posterpräsentation (20)
- Beitrag zu einem Tagungsband (11)
Sprache
- Englisch (81)
- Deutsch (20)
- Mehrsprachig (1)
Schlagworte
- LIBS (102) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (64)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (57)
- 1 Analytische Chemie; Referenzmaterialien (42)
- 1.9 Chemische und optische Sensorik (28)
- 8.0 Abteilungsleitung und andere (17)
- 1.3 Instrumentelle Analytik (6)
- 1.4 Prozessanalytik (4)
- 1.6 Anorganische Referenzmaterialien (4)
- 7 Bauwerkssicherheit (4)
- 7.1 Baustoffe (4)
- 1.1 Anorganische Spurenanalytik (3)
- P Präsident (3)
- P.0 Präsident und andere (3)
- 9 Komponentensicherheit (2)
- 9.4 Integrität von Schweißverbindungen (2)
- 4 Material und Umwelt (1)
- 4.0 Abteilungsleitung und andere (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
Eingeladener Vortrag
- nein (47)
The elemental analysis of seawater is often critical to the understanding of marinechemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdownspectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a greatpotential for in-situ elemental analysis of seawater. In practice, it is crucial to create acompact, low cost and power saving instrument for the long-term deep-sea observation. Arecently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidateas it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHzcan provide a considerable throughput for LIBS analysis. However, the DPSS lasers operateat moderate pulse energies, usually less than one mJ, which cannot sustain stablebreakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such aμJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. Thephase interface and mass flow generated by the near-field ultrasound can greatly reduce thebreakdown threshold and enhance element-specific emissions. Meanwhile, the highrepetition-rate pulses can also improve the breakdown probability and generate uniqueemission lines originated from the water molecule. We further demonstrate that the highrepetition-rate DPSS laser combined with the Echelle spectrometer can provide effectivequantitative analysis for metal elements in bulk water.
Asymmetrical laser-induced plasmas were investigated by a tomography approach based on the inverse Radon transform. Two distinct sources of asymmetricity were investigated: double-pulsed laser-induced plasmas in the orthogonal configuration and single-pulsed laser-induced plasmas under an inclined incidence angle. Both cases were observed at various delay times. The optical thinness of the laser-induced plasmas was achieved by appropriately adjusting the pulse energies. High temporal resolution is achieved by a gated intensified charge-coupled-device camera. The asymmetrical laser-induced plasmas are investigated in terms of their total emissivity, spectrally resolved emissivity, and temperature. The latter is obtained by the Saha–Boltzmann plot method. The images required for the inverse Radon transform technique were obtained with a high angular accuracy and reproducibility provided by mounting the spectrometer on a high-precision nano-positioning rotary stage. The plasmas were induced in the center of rotation of the stage. This arrangement allows the reconstruction of emissivity, which is integrated over a full spectral range (200-800 nm) or over a desired spectral range selected by a bandpass filter (~10 nm). It also allows for the reconstruction of spectrally-resolved emissivity in each cross sectional plasma slice by scanning the plasma across a spectrometer slit. The 3D maps of temperature and electron density are thus obtained for different types of asymmetric plasmas.
Asymmetrical laser-induced plasmas were investigated by a tomography approach based onthe inverse Radon transform. Two distinct sources of asymmetricity were investigated:double-pulsed laser-induced plasmas in the orthogonal configuration and single-pulsedlaser-induced plasmas under an inclined incidence angle. Both cases were observed atvarious delay times. The optical thinness of the laser-induced plasmas was achieved byappropriately adjusting the pulse energies. High temporal resolution was achieved by agated intensified charge-coupled-device camera. The asymmetrical laser-induced plasmaswere investigated in terms of their total emissivity, spectrally resolved emissivity, andtemperature. The latter was obtained by the Saha–Boltzmann plot method. The imagesrequired for the inverse Radon transform technique were obtained with a high angularaccuracy and reproducibility provided by mounting the spectrometer on a high-precisionnano-positioning rotary stage. The plasmas were induced in the center of rotation of thestage. This arrangement enabled the reconstruction of emissivity which was integrated overthe full spectral range (200–800 nm) or over a desired spectral range selected by a bandpassfilter (~10 nm). It also allowed for the reconstruction of spectrally-resolved emissivity ineach cross-sectional plasma slice by scanning the plasma across a spectrometer slit. The 3Dmaps of the temperature and electron density were thus obtained for different types ofasymmetric plasmas. The work will provide a more detailed description of the twoasymmetrical laser-induced plasmas. This might help with the development of LIBSinstrumentation using the orthogonal double-pulse geometry, or remote LIBS applicationswhich inherently rely on inclined-angle ablation.
In civil engineering, the laser-induced breakdown spectroscopy has been applied as a fast and reliable method for a quantitative evaluation of concrete cores. Due to a two-dimensional scanning, the heterogeneity of concrete can be evaluated and elements like Cl, Na, and S are related to the cement matrix only. This study deals with the temporal evaluation and imaging of laser-induced plasmas on cement-based materials, in order to investigate the impact of aggregates with diffrent grain size on the spectral response in LIBS.
Magnesium (Mg) is a major element in a range of silicate and carbonate minerals, the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg with natural abundances of 79 %, 10 %, and 11 %, respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight variations of isotope amount ratios n(26Mg)/n(24Mg) in biological, environmental and geological samples. Traditionally, isotope ratios are measured by mass spectrometric methods and isotope ratios are expressed as deviation from an internationally agreed upon material, i.e. the zero-point of the δ-value scale. Drawbacks of this method include the high costs for instruments and their operation, experienced operators and elaborate, time-consuming chromatographic sample preparation.
Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high- resolution continuum source graphite furnace molecular absorption spectrometry (HR- CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS).
For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X2Σ → A2Πi and X 2Σ → B2Σ+ around wavelengths 358 nm and 268 nm, respectively. In the case of LAMIS, we investigated the MgF molecule for the electronic transition A2Πi → X2Σ as well as the MgO molecule for the electronic transition A1Π+ → X1Σ around 500 nm. The MgF and MgO spectra are described by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by partial least square regression (PLS) calibrated with enriched isotope spikes. Isotope amount ratios in rock samples with and without matrix separation were analyzed. Calculated δ-values were accurate and obtained with precisions ranging between 0.2 ‰ and 0.5 ‰ (1 SD, n = 10). On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared to MC-ICP-MS.
Magnesium is a naturally occurring element that can be found in several mineral forms in the earth crust. This element presents three stable isotopes 24Mg, 25Mg and 26Mg with a natural abundance of 79%, 10%, and 11% respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight isotope amount ratio variations n(26Mg)/n(24Mg) in biological and geological samples. Traditionally, isotope amount ratios have been measured by mass spectrometric methods. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time-consuming. Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS). For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X 2Σ → A 2 Πi and X 2Σ → B 2Σ+ around wavelengths 358 nm and 268 nm respectively. In the case of LAMIS, it was studied the MgF molecule for the electronic transitions A 2Πi → X 2Σ as well as the MgO molecule for the electronic transition A 1Π+ → X 1Σ around 500 nm. The MgF and MgO spectra are composed by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by a partial least square regression (PLS) calibrated with enriched isotope spikes. The isotope amount ratios in rock samples with and without matrix separation were analyzed. Resulting delta values were obtained with precisions ranging between 0.2-0.5 ‰. On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared with MC-ICP-MS.
The durability and the lifetime of reinforced concrete structures can be drastically reduced by the influence of damage processes. One of the most common causes is chloride-induced corrosion, which is triggered by increased chloride content near the reinforcement. In a study, the chloride content should be determined directly at corrosion areas. The LIBS system used consists of a micro-chip laser (3 mJ, 100 Hz, 1.5ins) and two compact spectrometers covering the wavelength range of 177-355 nm (UV) and 750-940 nm (NIR). The analysis of the chloride content was carried out via the atomic chlorine spectral line 837.59 nm, using helium for signal amplification. Calibrations were carried out for quantitative chlorine measurements with 15 reference samples in the working range of 0.05 to 6.00 wt% chlorine. The calibration of the LIBS system was done according to DIN 32 645 and was tested for linearity. The determination of the quantitative chlorine contents was carried out on samples which were broken and thus have a high surface roughness. This requires real time correction of the focus point to compensate for the roughness of the samples. The poster shows spatially resolved element distributions and determined quantitative chloride concentrations near the corrosion Areas.
In a joint project of partners from industry and research, the automated recycling of construction and demolition waste (CDW) is investigated and tested by combing laser-induced breakdown spectroscopy (LIBS) and near-infrared (NIR) spectroscopy. Joint processing of information (data fusion) is expected to significantly improve the sorting quality of various materials like concrete, main masonry building materials, organic components, etc., and may enable the detection and separation of impurities such as SO3-cotaining building materials (gypsum, aerated concrete, etc.). The project focuses primarily on the Berlin site to analyze the entire value chain, minimize economic/technological barriers and obstacles at the cluster level, and sustainably increase recovery and recycling rates. First measurements with LIBS and NIR spectroscopy show promising results in distinguishing various material types and indicate the potential for a successful combination. In addition, X-ray fluorescence (XRF) spectroscopy is being performed to obtain more information about the quantitative elemental composition of the different building materials. Future work will apply the developed sorting methodology in a fully automated measurement setup with CDW on a conveyor belt.
In a joint project of partners from industry and research, the automated recycling of construction and demolition waste (CDW) is investigated and tested by combing laser-induced breakdown spectroscopy (LIBS) and near-infrared (NIR) spectroscopy. Joint processing of information (data fusion) is expected to significantly improve the sorting quality of various materials like concrete, main masonry building materials, organic components, etc., and may enable the detection and separation of impurities such as SO3-cotaining building materials (gypsum, aerated concrete, etc.). The project focuses primarily on the Berlin site to analyze the entire value chain, minimize economic/technological barriers and obstacles at the cluster level, and sustainably increase recovery and recycling rates. First measurements with LIBS and NIR spectroscopy show promising results in distinguishing various material types and indicate the potential for a successful combination. In addition, X-ray fluorescence (XRF) spectroscopy is being performed to obtain more information about the quantitative elemental composition of the different building materials. Future work will apply the developed sorting methodology in a fully automated measurement setup with CDW on a conveyor belt.
Die Laserinduzierte Plasmaspektroskopie (engl.: Laser-induced Breakdown Spectroscopy, kurz: LIBS) ist eine Kombination aus Laserablation mittels eines energiereichen Laser-Pulses, der Erzeugung eines Plasmas auf der zu untersuchenden Oberfläche und dem quantitativen Nachweis der Elementzusammensetzung durch spektroskopische Untersuchung der vom Plasma emittierten Strahlung. Ein LIBS-Gerät liefert dem sachkundigen Planer Daten für die Bewertung des Ist-Zustandes von Bauwerken unserer Infrastruktur durch die zweidimensionale Erfassung von Elementverteilungen. Typische Anwendungen sind die Erfassung von Chlor, Schwefel, Kohlenstoff, Natrium, Kalium und Lithium in Beton oder als – Qualitätssicherung – der Nachweis der mit einem Marker versehenen Tiefenhydrophobierung.
In Zusammenarbeit zwischen Industriepartnern und der BAM wurden ein Labor und ein mobiles LIBS-System für die Vor-Ort-Messungen entwickelt. Die Analyse erfolgt vollautomatisch. Die Ortsauflösung beträgt bis zu 0,1 mm x 0,1 mm. Es können Messflächen von 140 mm x 170 mm gescannt werden. Die Erstellung von 2D-Elementverteilungen im Beispiel unten benötigt weniger als 10 Minuten.