A steel pipeline segment of 2.5 m length was subjected to quasi-static four-point bending load in three steps for studying the initial cracking and damage accumulation based on the Acoustic Emission (AE) technique and by the direct current potential drop (DCPD) technique. For the latter, a new post-test analysis method was established.
AE is found more sensitive to crack initiation than DCPD. Formation of mesoscopic and macroscopic cracks as well as their closure and the resulting friction generate weighted peak frequencies below 400 kHz, whereas microscopic cracking produces AE with broad band spectra identifiable by weighted peak frequencies above 400 kHz. Critical states alike the maximum load level and the leak opening were accompanied by peak amplitudes above 85 dBAE. This rather fundamental study provides a data base for possibly developing advanced strategies of detection and alarm systems based on acoustic monitoring of pipelines, or at least, steel structures.
Um die Versagensabläufe über die verschiedenen Skalen im Holzwerkstoff verfolgen zu können, werden Zugversuche an Lagenhölzern mittels Schallemissionsmessung überwacht. Synchron erfolgen In-situ-Messungen mit Digitaler Bildkorrelation bzw. Synchrotron-Mikro-Computertomographie. Die Kombination aller Ergebnisse wie auch die Anwendung der frequenzbasierten Mustererkennung und die Simulation ausgewählter Versuche zielen auf die Identifizierung zugrunde liegender Mechanismen hin. Abschließend werden Ansätze für ein Monitoring von Holzstrukturen diskutiert.
To better understanding the failure of adhesive joints tensile tests were carried out on miniature test specimens from Norway spruce in the synchrotron. Urea-formaldehyde resin was used as adhesive. e. For comparison purposes, tensile tests were carried out on solid wood and on bonded miniature tensile shear samples with acoustic emission. The acoustic emission signals of all the experiments occurred with classified pattern recognition. This resulted in two classes of signals for each two frequency peaks. One class consisted of the low-frequency and the other of the higher-frequency peak of higher intensity, but this was essentially independent from the structure (solid wood or plywood) and size scale of the test specimens. The influence of the adhesive layers was determined on wood test specimens on laboratory scale and on miniature test specimens with an adhesive layer and selected fiber orientations. This gave evidence that the sound emission signals from the failure of the adhesive layer presumably of the class with low frequency signals peak in the range of services can be assigned.
Acoustic Emission
(2018)
Das Phänomen Schallemission (eng. Acoustic Emission, AE) ist eine Begleiterscheinung bei aktiven Mechanismen und Prozessen wie sie in Werkstoffen auftreten, die einer Belastung durch Krafteinwirkung oder durch Änderung der Umgebungsbedingungen ausgesetzt sind. Plastische Verformung, Risswachstum, Korrosion oder der Übergang zu einer anderen Phase generieren u.a. transiente elastische Wellen, die sich im Werkstoff und an der Materialoberfläche ausbreiten. Auftretende Auslenkungen von wenigen hundert Pikometern sind mit piezo-elektrischen AE Sensoren detektierbar. Aufzeichnungsraten von bis zu 40 MHz ermöglichen dabei zeitliche Auflösungen von einigen Nano- bis Mikrosekunden. Die Dechiffrierung der detektierten Informationen ist für die Material- und Versagenscharakterisierung sowie für Anwendungen in der Struktur- oder Prozessüberwachung ein zentraler Forschungsschwerpunkt.
Nach einem kurzen Überblick zu den Grundlagen werden ausgewählte Ansätze der AE Methode vorgestellt und diskutiert:
1) AE Monitoring von Pipelines als Referenzmessung für die Entwicklung eines akustischen faseroptischen Monitorings (AGIFAMOR)
2) Schwellwertfreie AE Messung im 4-Punkt-Rohrbiegeprüfstand BAM_9.1 (AGIFAMOR)
3) Kombination von AE mit Röntgen-Mikrotomografie und die Anwendung der frequenzbasierten Mustererkennung ermöglichen eine Zuordnung von AE und Mechanismen (Ergebnisse aus dem SNSF Projekt Nr. 127'134, Baensch 2014, Diss. ETH No. 22372)