Umwelt-Material-Interaktionen
Filtern
Dokumenttyp
- Vortrag (16)
- Zeitschriftenartikel (7)
Schlagworte
- TED-GC/MS (23) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (16)
AbstractMicroplastics (MP) can be detected in all environmental systems. Marine and terrestrial aquatic systems, especially the transported suspended solids, have often been the focus of scientific investigations in the past. Sediments of aquatic river systems, on the other hand, were often ignored due to the time‐consuming sample preparation and analysis procedures. Spectroscopic measurement methods counting particle numbers are hardly suitable as detection methods, because there are plenty of natural particles next to a small number of MP particles. Integral methods, such as thermoanalytical methods are determining the particle mass independently of the inorganic components.In this study, a workflow for sample preparation via density separation and subsequent analysis by thermal extraction desorption‐gas chromatography/mass spectrometry is presented, which leads to representative and homogeneous samples and allows fast and robust MP mass content measurements suitable for routine analysis. Polymers were identified and quantified in all samples. Polyethylene and styrene‐butadiene rubber are the dominant polymers, besides polypropylene and polystyrene. Overall, total polymer masses between 1.18 and 337.0 µg/g could be determined. Highest MP concentrations in riverbed sediment are found in sites characterized by low flow velocities in harbors and reservoirs, while MP concentrations in sandy/gravelly bed sediments with higher flow velocities are small.
Inputs of plastic impurities into the environment via the application of fertilizers are regulated in Germany and the EU by means of ordinances. Robust and fast analytical methods are the basis of legal regulations. Currently, only macro- and large microplastic contents (>1 mm) are measured. Microplastics (1–1,000 µm), are not yet monitored. Thermal analytical methods are suitable for this purpose, which can determine the mass content and can also be operated fully automatically in routine mode. Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) allows the identification of polymers and the determination of mass contents in solid samples from natural environments. In accordance with the German or European Commission (EC) Fertiliser Ordinance, composting plants should be monitored for microplastic particles with this method in the future. In this context a compost plant was sampled. At the end of the rotting process, the compost was sieved and separated in a coarse (>1 mm) and a fine fraction (<1 mm). The fine fraction was processed using density separation comparing NaCl and NaI as possible salt alternative and screened for microplastic masses by TED-GC/MS with additional validation and quality assurance experiments. With TED-GC/MS total microplastics mass contents of 1.1–3.0 μg/mg in finished compost could be detected with polyethylene mainly. What differs much to the total mass of plastics in the coarse fraction with up to 60 μg/mg, which were visually searched, identified via ATR-FTIR and gravimetrically weighted.
Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed.
TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance.
The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation.
Despite the increasing concern about the harmful effects of micro- and
nanoplastics (MNPs), there are no harmonized guidelines or protocols yet available for MNP ecotoxicity testing. Current ecotoxicity studies often use commercial spherical particles as models for MNPs, but in nature, MNPs occur in variable shapes, sizes and chemical compositions. Moreover, protocols developed for chemicals that dissolve or form stable dispersions are currently used for assessing the ecotoxicity of MNPs. Plastic particles, however, do not dissolve and also show dynamic behavior in the exposure medium, depending on, for example, MNP physicochemical properties and the medium’s conditions such as pH and ionic strength. Here we describe an exposure protocol that considers the particle-specific properties of MNPs and their dynamic behavior in exposure systems. Procedure 1 describes the top-down production of more realistic MNPs as representative of MNPs in nature and particle characterization (e.g., using thermal extraction desorption-gas chromatography/mass spectrometry). Then, we describe exposure system development for short- and long-term toxicity tests for soil (Procedure 2) and aquatic (Procedure 3) organisms. Procedures 2 and 3 explain how to modify existing ecotoxicity guidelines for chemicals to target testing MNPs in selected exposure systems. We show some examples that were used to develop the protocol to test, for example, MNP toxicity in marine rotifers, freshwater mussels, daphnids and earthworms. The present protocol takes between 24 h and 2 months, depending on the test of interest and can be applied by students, academics, environmental risk assessors and industries.
It is of high priority to capture the extent of microplastics (MP) contamination for understanding its impact and consequences to our environment. However, due to a lack of standardized methods, MP analysis as well as its quality assurance, is still a challenge. The thermal extraction desorption-gas chromatography/-mass spectrometry (TED-GC/MS) as a novel innovative thermoanalytic method can detect MP particles in environmental samples based on their decomposition products. According to MP analysis, a distinctively larger polyethylene (PE) content in comparison to other synthetic polymers was detected in environmental samples. Various substances within the matrix which have a similar molecular structure to PE, like fats and oils, might interfere with its marker and lead to an overestimation. In this investigation an automated extraction method, the accelerated solvent extraction (ASE), is introduced as quality control tool before TED-GC/MS measurement. Thereby, not the extract like usually used, but the solid filtrate is analyzed. The aim is to clean the environmental samples from solvent removable compounds which could lead to false positive signals and thus receive a more accurate PE mass. Consequently, a sample mimicking environmental samples with a defined matrix and a known polymer mass was generated. The common polymers polyethylene, polypropylene, polystyrene and styrene-butadiene rubber, used as an indication for tire wear, were added to the matrix. Different parameters for ASE extraction were varied such as different solvents, filters and purge time. Finally, a PE recovery rate of 91 % after extraction could be reached.
Mit dem stetigen weltweiten Anstieg der Nachfrage nach Polymerprodukten nimmt auch die potenzielle Menge an Kunststoffabfällen in der Umwelt zu. Problematisch ist, dass viele der wirtschaftlich relevantesten Kunststoffe sehr lange brauchen, um in der Umwelt abzubauen, sich dort akkumulieren und in kritisch betrachtetes Makro- und Mikroplastik zu zerfallen. Auf der Grundlage des Vorsorgeprinzips fordert die Europäische Kommission daher die Entwicklung neuer polymerer Materialien, die diesem Problem der Persistenz entgegenwirken und unter natürlichen Umweltbedingungen schneller abgebaut werden können. 1,2
Um dieses Problem anzusprechen, wurden mittels additiver Fertigung Polymerblends aus photooxidationsempfindlichem Polystyrol (PS) und hydrolyseempfindlicher Polymilchsäure (PLA) hergestellt. Die Hypothese war, dass sich die beiden Thermoplaste aufgrund ihrer unterschiedlichen Abbauprozesse gegenseitig in ihrem Abbau unterstützen, wenn sie unter moderaten, realitätsnahen Umweltalterungsbedingungen (45 °C) abwechselnd der Photooxidation und Hydrolyse ausgesetzt werden.
In der Praxis zeigten die Ergebnisse, dass die Degradation von PLA durch die Anwesenheit von PS deutlich beschleunigt worden ist – wohingegen die Degradation von PS gehemmt wurde. In diesem Vortrag werden die detaillierten Ergebnisse der Oberflächen- (ATR-FTIR, REM) und Bulk-Analysen (DSC, TGA, FTIR-Transmission, TED-GC/MS) der Blends sowie ergänzende Mikroplastik-Ergebnisse des umgebenden Wassermediums (TED-GC/MS) erörtert.