Umwelt
Filtern
Dokumenttyp
- Vortrag (13)
- Posterpräsentation (5)
Referierte Publikation
- nein (18)
Schlagworte
- TED-GC-MS (18) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (13)
Due to the favorable properties of polymers, their production and thus their input into the environment has increased significantly in recent decades. Currently, FTIR or Raman spectroscopy are mainly applied for the analysis of microplastic particles (MP) in environmental samples. However, these methods have great difficulties in determining metrologically traceable MP values, especially with regard to the limiting values, as preferred in regulation. Therefore, we developed a systematic and fast thermoanalytical method called TED-GC-MS (thermal extraction desorption gas chromatography mass spectrometry), which determines mass contents. Now the current goal is the determination of its process parameters.
This poster illustrates the theoretical requirements for MP analysis (left side) and contrast them with the current state of research (right side).Unexpected practical problems are presented and the relatively new method is discussed concerning the quality requirements of well-established methods such as LC-or GC-MS.
Im Vortrag wird die Problematik Mikroplastik eingeführt und ein Probenset aus dem Mittelmeer mit ersten Ergebnissen besprochen. Die Alterung von Polymeren im Umweltkontext sowie Möglichkeiten der Analyse von Polymeralterungsfortschritten werden diskutiert. Die thermoanalytische Methode mit Zersetzungsgasanalytik (TED-GC-MS) wird eingeführt und deren Einsatzmöglichkeiten in der Thematik umrissen.
Der Vortrag beschreibt den Entwicklungsprozess des Analysenverfahrens TED-GC-MS zur Bestimmung von Mikroplastikgehalten in Umweltproben im Rahmen des BMBF-Projektes MiWa. Die Funktionsweise, die Automatisierung und die Optimierung einzelner Geräteparameter und Leistungsdaten werden gezeigt. Untersuchungen des Einflusses von Probenmatrices werden dargestellt und die Ergebnisse einiger Messkampagnen und Ringversuche vorgestellt, die die Routinefähigkeit des Verfahrens dokumentieren.
The number of publications reporting the amount of microplastic (MP) all over the world increased rapidly. Methods used so far are very time consuming and not able to provide information on total contents. As harmonised sampling, sample preparation and analysis strategies are missing different studies can hardly be compared and quantitative data, including identification and mass contents of the polymers found, are missing. This leads to a lack of comprehensive understanding of MP occurrence, source and entry pathways into the environment.
We developed a method, Thermal Extraction/Desorption-Gaschromatography-Massspectrometry, as a fast screening method for MP analysis. Solid residues of water samples are heated up to 600 C under a N2 atmosphere without any sample preparation. The collected decomposition gases are separated in a gas chromatography system and detected in a mass spectrometer. Mass contents of the identified polymers can be calculated.
In this presentation we will show first results from the influent of the wastewater treatment plant Kaiserslautern (Germany) and its combined sewage system as possibly entry pathway. In order to determine the relevance of wastewater split streams analysis of grey water will be conducted. Samples are fractionally filtered by a sieve cascade with mesh sizes of 500, 100, 50 µm.
Plastics and rubber are used in many applications, such as packaging, building, construction and mobility. Due to their favourable properties like light weight, flexible processing and low costs their production and consequently their input into the environment has increased significantly over the last decades. In the environment, oxidation processes and mechanical abrasion lead to the decomposition of these plastics into small fragments, called microplastic (< 5 mm). By definition, microplastics only involve thermoplastics and duroplastics but elastomers made out of synthetic polymers (e. g. styrene butadiene rubber), modified natural polymers (e. g. natural rubber) and products of synthetic polymers (e. g. tires) are also part of the current microplastic discussion. The main entry pathway of rubber into the environment is the wear of used tire treads in road traffic. Lassen et al. showed that 60 % of the microplastic emissions in Denmark into the environment come from secondary microplastics generated by tires. Rain events can cause microplastic and rubber to get from the street into the street inlets. Depending on the sewage system, these waters are sometimes not cleaned in the sewage treatment plants and reach the surface waters untreated.
To analyse microplastic particles in samples, mainly FTIR or Raman spectroscopic methods are applied at present. Rubber or tire particles in environmental samples cannot be analysed by these methods, because the added carbon black leads to annoying absorption and fluorescent effects.
We developed a thermoanalytical method, the so-called TED-GC-MS (thermal extraction desorption gas chromatography mass spectrometry), which allows the simultaneous detection of microplastic and tire wear with almost no sample preparation in about 2.5 h. The TED-GC-MS is a two-step analytical method which consists of a thermobalance and a GC-MS system. Up to 50 mg of an environmental sample is heated up to 600 °C in a nitrogen atmosphere. During pyrolysis, between 300 and 600 °C polymer-specific decomposition products are produced and collected on a solid phase. Afterwards the substances are desorbed, separated and analysed using the GC-MS.
The aim of the present work is to present the TED-GC-MS as a time efficient screening method to quantify the industrial most relevant polymers in street run-off samples. Analytical challenges in the determination of polyethylene (PE), polypropylene (PP), polystyrene (PS), polyethylene terephthalate (PET) and polyamide (PA), polymethyl methacrylate (PMMA) and styrene-butadiene-rubber (SBR) as a component of tire wear are honestly discussed.
The study area is a 200 m long section of the Clayallee in Berlin, a representative typical urban catchment area. The road run-off in this section flows through the gullies directly into a sample chamber, which directs the runoff in an open channel to the rainwater sewer of this area. The sample chamber allows a sample to be taken directly from the road run-off without mixing with the run-off from other areas. The sample chamber is equipped with an automatic sampler. The automatic sampler is controlled by a conductivity sensor to detect the storm event at an early stage. The sensor gives the sampler a signal to start the sampling program when it gets in contact with water and reaches a certain conductivity threshold. The capacity of the sample container is 100 l and the maximum delivery of the automatic sampler is 2.8 l/min.
Afterwards, the water was pumped through various stainless-steel sieves with a diameter of approximately 20 cm and mesh widths of 500, 100, 50 μm. The obtained solids were steam sterilized, freeze-dried and measured with the TED-GC-MS.
The results of the TED-GC-MS-measurements are summarized in Figure 1. It shows the polymers which were detected in 1 mg of the dry masses of various street run off samples obtained during a period of 1.5 years. We detected PMMA, PS, PP, PE and SBR, as a component of tire wear in the samples. The quantification of the polymers leads to amounts of PS, PP, PE and SBR between 0 µg and 10 µg. PMMA was only detected in traces.
While plastics have become indispensable in our daily lives over the last decades, the input into the environment has been increasing concurrently. Plastics often end up in the environment because of intensive use and poor waste management practice. They are subjected to aging and fragmentation and finally be deposited as microplastic particles or in short microplastics (MP). MP are defined as particles originating from synthetic polymers between 1 µm and 5 mm.
Although the pervasive abundance of MP in aquatic environments has been demonstrated comprehensively, less is known about the occurrence and fate of MP in terrestrial ecosystems. It is still unclear if soil functions as a MP source or a sink for aquatic environments. MP can either be transported into water bodies by soil erosion or be retained in soils. The few studies published are not comparable because of non-existent harmonized and standardized methods for sampling, sample preparation, and analysis.
For an assessment of a potential exposure situation of MP, the determination of a mass content in the soil is crucial. Consequently, spectroscopic methods like Raman or FTIR are not suitable, as they deliver information about the shape and size of individual particles. Therefore, we show the application of ThermoExtractionDesorption-GasChromatography-MassSpectrometry (TED-GC-MS) for MP analysis in the soil. In this method, the soil sample is heated up to 600 °C in a nitrogen atmosphere. The decomposition gases are sorbed on a solid phase, then transferred to a GS-MS system where they are desorbed, separated and identified. The method allows the rapid identification of individual polymers through the detection of specific decomposition products, but also the quantitative determination of the MP mass. Besides thermoplastics, elastomers originated from tire abrasion, can be detected.
In the present study, several terrestrial ecosystems in south-west Germany were systematically sampled. Subsequent sample preparation included sieving in fractions of 5-100 µm, 100-1000 µm, and 1-5 mm. MP were extracted by density separation using ZnCl2 solutions. The detection was done by TED-GC-MS measurements. Data of agricultural areas and floodplains are presented exemplarily. A quantitative assessment of highly occurring MP from littering as well as tire abrasion is conducted.
The pathways of plastics, especially of microplastic (MP), in environmental compartments, particularly in aquatic systems, are not well understood. The critical point is the lack of fast, harmonised methods for sampling, sample preparation and sample analysis. These three analytical steps are dependent on one another and must be optimised.
In recent years, we developed a method for representative sampling and fast detection of MP in aqueous systems. The sampling in different freshwater bodies is performed in the field with a fractionated filtration system using mesh sizes of 500, 100 and 50 µm. For water with an intermediate or high content of suspended particular matter a minimum of 1000 L has to be filtered. In the lab, mesh sizes of 10 and 5 µm are used for further filtration. Subsequently, the water filtrates of the different particle size classes are sterilised, dried, weighed and homogenised, if necessary.
Conventional methods for MP analysis are infrared and raman spectroscopy, giving information on the shapes and numbers of individually identified MP particles. Our focus is on the determination of mass contents of various polymers potentially contained in environmental samples. For qualitative and quantitative MP detection TED-GC-MS is used, a two-step method based on gas chromatography-mass spectrometry (GC-MS) with previous thermal extraction. This method not only enables us to screen the samples for characteristic marker-molecules, thus identifying single polymers, but furthermore allows the calculation of mass contents of individual polymers. In the present work, different freshwater compartments were exemplarily studied to identify containing polymers and calculate their mass content in MP particles.
Der Vortrag stellt spektroskopische und neue thermoanalytische Verfahren zum Nachweis von Mikroplastik in Umweltproben vor. Ein spezieller Fokus liegt auf dem neu entwickelten Verfahren der TED-GC-MS. Zusätzlich wird gezeigt, wie die TED-GC-MS eingesetzt werden kann, um Reifen in der Umwelt zu bestimmen.
Das Auftreten von Mikroplastik (MP) in aquatischen Ökosystemen ist bereits vielfältig dokumentiert. MP sind Kunststoffpartikel mit einer Größe kleiner als 5000 µm. Sie gelangen entweder als primäres MP (bspw. Zusätze in Kosmetikartikeln) oder als sekundäres MP (Fragmentierung größerer Kunststoffteile) in die Umwelt. Über die Existenz von Kunststoffpartikeln und deren Verbleib in terrestrischen Systemen ist wenig bekannt. Bis heute ist es unklar, ob MP im Boden durch Bodenerosion in die aquatische Umwelt transportiert wird und Boden somit als MP-Quelle für Gewässer fungiert, oder ob Partikel im Boden zurückgehalten werden und Boden eine MP-Senke darstellt. Hierzu sind aussagekräftige Messungen von Proben notwendig.
Das Fehlen harmonisierter Verfahren für die Probenahme, Probenaufbereitung und Detektion erschwert die aktuelle Diskussion. In den wenigen bisher veröffentlichten Studien fanden hauptsächlich spektroskopische Methoden wie FTIR- oder Raman-Mikroskopie als Detektionsverfahren Anwendung. Diese liefern in der Regel Aussagen über Partikelanzahlen.
Im vorliegenden Projekt soll als Analysemethode die von uns entwickelte ThermoExtraktionDesorption-GasChromatograpie-MassenSpektrometrie (TED-GC-MS) genutzt werden. Bei dieser Methode wird die Probe bis 600 °C erhitzt; die Zersetzungsgase werden auf einer Festphase sorbiert, anschließend in ein GS-MS-System überführt und dort desorbiert, getrennt und identifiziert. Die Methode erlaubt auf schnellem Wege über den Nachweis von spezifischen Zersetzungsprodukten die Identifikation einzelner Polymere, aber auch die quantitative Bestimmung des MP-Massegehaltes in einer Bodenprobe.
Ziel des vorliegenden Projektes ist die Entwicklung eines systematischen Protokolls zur Probenahme, Probenaufarbeitung und anschließenden Analyse mittels TED-GC-MS von MP in terrestrischen Proben. Neben der Erstellung einer systematischen Probenahmestrategie sind Probenaufarbeitungsschritte wie die Reduktion der anorganischen Matrix mittels Dichteseparation sowie die oxidative Zersetzung organischer Matrixbestandteile notwendig.
Im vorliegenden Tagungsbeitrag präsentieren wir die Anwendung der TED-GC-MS für die Bestimmung von MP in verschiedenen terrestrischen Umweltmatrizen.