Fire Science
Filtern
Dokumenttyp
- Vortrag (158)
- Zeitschriftenartikel (152)
- Beitrag zu einem Tagungsband (59)
- Posterpräsentation (32)
- Buchkapitel (20)
- Beitrag zu einem Sammelband (3)
- Dissertation (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
- Forschungsbericht (2)
- Monografie (1)
- Sonstiges (1)
Sprache
- Englisch (337)
- Deutsch (94)
- Tschechisch (2)
- Mehrsprachig (2)
Schlagworte
- Flame retardant (36)
- Flame retardancy (29)
- Brandschutz (24)
- Behälterversagen (17)
- Fire resistance (14)
- Fire test (13)
- Flammability (13)
- Feuerwiderstand (12)
- Fire (12)
- LNG (12)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (279)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (212)
- 3 Gefahrgutumschließungen; Energiespeicher (89)
- 3.2 Gefahrguttanks und Unfallmechanik (83)
- 2 Prozess- und Anlagensicherheit (76)
- 2.1 Sicherheit von Energieträgern (74)
- 7.3 Brandingenieurwesen (64)
- 8 Zerstörungsfreie Prüfung (18)
- 7.1 Baustoffe (14)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (12)
Paper des Monats
- ja (7)
The recommendation is based on the coauthors’ work organized by the RILEM TC 256-SPF ‘‘Spalling of concrete due to fire: testing and modelling’’. The Committee has defined two types of screening tests for characterization of concrete propensity to fire spalling: Material screening tests and Product screening tests. Definitions of both types of tests are given in the paper. The following recommendations apply to Material screening tests. The material screening tests described in these recommendations are a set of minimum requirements to test concrete spalling propensity (for example, the minimal specimen size). This document covers the aspects of concrete characterization, specimen geometries, storage conditions, test methods and measured parameters.
Since we are facing more extreme weathers, the occurrence
of wildfire has also increased accordingly. The EU project
TREEADS aims to adopt a holistic forest fire management
and an adaptive, collaborative governance approach based
on the deployment of a new systemic and technological
framework covering all three interconnected fire
management stages: prevention & preparedness, detection &
response, and restoration & adaptation.
As part of the task in the so-called German pilot, numerical
simulations are performed to investigate the influencing
factors for vegetation fires with fire dynamics simulator
(FDS). The characteristics of vegetation are strongly related
to the local weather and ecosystem. The investigation of the
fire behavior of vegetation must be based on the local
vegetation in Germany. Thus, the flame propagation of typical
vegetation in Germany (pine needles, oak leaves, European
beech leaves etc.) was investigated in small scale and medium
scale experiments. These results are used as validation case
studies for the further simulations.
Revolutionizing our polymer industry for adaption to a sustainable carbon circular economy has become one of today’s most demanding challenges. Exploiting renewable resources to replace fossil-fuel—based plastics with biopolymers such as poly(lactic acid) (PLA) is inevitable while using waste streams as a raw material resource at least is promising. When it comes to using PLA as technical polymer, its high flammability must be addressed by flame retardants compatible with the thermoplastic processing of PLA and its compostability. This study proposes microalgae enriched with phosphorus from wastewater (P-Algae) as an elegant way towards a kind of sustainable organophosphorus flame retardant. The concept is demonstrated by investigating the processing, pyrolysis, flammability, and fire behavior of PLA/P-Algae, while varying the P-Algae content and comparing P-Algae with four alternative bio-fillers (phosphorylated lignin, biochar, thermally treated sewage sludge, and metal phytate) with different P-contents as meaningful benchmarks.
The synergistic behavior of different silicon compounds is investigated in flame retardant biocomposites with aluminum trihydroxide (ATH) as the main flame retardant. The paper shows a new approach towards sustainable biocomposites through the implementation of thermoplastic starch (TPS), leather fibers from industrial waste streams, and non-hazardous flame retardants and synergists. In these multicomponent systems, the different components address different modes of action in the fire scenario. When ATH is partially substituted by glass frits or layered silicates, fire performance is enhanced without changing the total amount of filler in the polymer. In a biocomposite with 25 phr of fiber and 90 phr of ATH, substituting 5 phr of ATH for layered silicates increased the LOI from 31.5 vol % to 34.8 vol %, decreased the peak of heat release by 20%, and increased the UL 94 rating from V-1 to V-0.
The global plastic industry relies on fossil-based materials, presenting environmental challenges. A sustainable polymer namely poly(limonene carbonate) (PLimC), made of limonene and CO2 as two monomers from non-food sources, shows advances in various applications where additives such as flame retardants (FRs) are crucial to comply with fire safety measures.
The variety of FRs is wide, and therefore the approach involved conducting a comparative study of four different halogen-free flame retardant systems that are conventionally used in polycarbonates and polyolefins to understand which FR enhances the flame resistance of PLimC most effectively. The primary task of the project is to conduct experimental evaluations to analyze the thermal properties, flammability, and fire behavior of each system. This data will offer valuable insights towards the advancement of safer and more sustainable materials.
Fire-induced spalling of normal strength concrete with different types of blended Portland cement
(2024)
The cement industry is looking to reduce its overall CO2 footprint. Greener manufacturing can be achieved by the introduction of more clinker-reduced cements. Concrete exposed to fire tends to show explosive spalling caused by thermomechanical and thermohydraulic processes. It is therefore essential to determine how concretes with clinker-reduced cements behave under fire exposure, especially for concretes containing calcined clays, as these are expected to be the supplementary cementitious material of the future. In this paper, normal strength concretes with four different cements (CEM I, CEM II/A-LL, CEM III/A and CEM II/B-Q) were examined for their fire-induced spalling behaviour. In addition, a mix with PP fibres was investigated for each concrete. The experiments were conducted on ring-restrained cylindrical specimens exposed to the hydrocarbon fire curve. The results showed that the cement type influences spalling behaviour. Samples with CEM I spalled the least, followed by CEM II/A-LL and CEM III/A. Finally, samples with CEM II/B-Q showed the most severe damage. It was found that the spalling behaviour of different concretes correlates with the moisture content before exposure to fire, meaning that higher moisture content leads to higher spalling susceptibility. The use of 2 kg/m³ PP fibres completely inhibited spalling regardless of the cement type used and therefore remains a successful avoidance strategy.
The systematic transfer of solvent-free, additive flame retardant (FR) formulations from epoxy resins to glass fiber-reinforced epoxy composites (GFRECs) through prepregs is difficult. Additionally, obtaining data on their post-fire mechanics is often challenging. Utilizing melamine polyphosphate (MPP), ammonium polyphosphate (APP), and silane-coated ammonium polyphosphate (SiAPP) FRs with low-melting inorganic silicates (InSi) in an 8:2 proportion and 10% loading by weight in a diglycidyl ether of bisphenol A (DGEBA) resin, a systematic investigation of the processing properties, room-temperature mechanics, and temperature-based mechanics of the systems was performed. The resin was cured with a dicyandiamide hardener (DICY) and a urone accelerator. The results revealed no substantial impact of these FRs at the current loading on the resin's glass transition temperature or processability. However, the fire residues from cone calorimetry tests of the composites containing FRs were found to be only 15-20% of the thickness of the resins, implying a suppression of intumescence upon transfer. At room temperature, the decrease in the flexural modulus for the composites containing FRs was negligible. Exposure of the composites in a furnace at 400°C as a preliminary study before ignition tests was shown to cause significant flexural moduli reductions after 2.5 min of exposure and complete delamination after 3 min making further testing unviable. This study emphasizes the need for future research on recovering modes of action upon transfer of FR formulations from resins to composites. Based on the challenges outlined in this investigation, sample adaptation methods for post-fire analysis will be developed in a future study.
Cryogenic liquefied gases, such as liquid hydrogen (LH2) and liquefied natural gas (LNG), are becoming more popular as eco-friendly energy sources. However, using these gases more often increases the risk of accidents, making it important to conduct thorough risk assessments. The storage systems for these gases rely on thermal superinsulation (TSI), which can fail under extreme heat, especially during fires. Therefore, it is essential to study how and why TSI fails. This research (part of PhD topic) aims to examine insulation performance, thereby improving the overall safety of cryogenic storage systems.
Revolutionizing our polymer industry for adaption to a sustainable carbon circular economy has become one of today’s most demanding challenges. Exploiting renewable resources to replace fossil-fuel—based plastics with biopolymers such as poly(lactic acid) (PLA) is inevitable while using waste streams as a raw material resource at least is promising. When it comes to using PLA as technical polymer, its high flammability must be addressed by flame retardants compatible with the thermoplastic processing of PLA and its compostability. This study proposes microalgae enriched with phosphorus from wastewater (P-Algae) as an elegant way towards a kind of sustainable organophosphorus flame retardant. The concept is demonstrated by investigating the processing, pyrolysis, flammability, and fire behavior of PLA/P-Algae, while varying the P-Algae content and comparing P-Algae with four alternative bio-fillers (phosphorylated lignin, biochar, thermally treated sewage sludge, and metal phytate) with different P-contents as meaningful benchmarks.
Steel tension members with hollow sections are used in applications such as trusses. To ensure the fire resistance, the steel must be prevented from heating up too quickly. A suitable solution is the application of intumescent coatings. However, the approval-based scope of application of these products generally does not include steel tension members with hollow section. This is mainly due to the lack of a corresponding European test and assessment standard. To investigate the characteristics to be considered when testing these structural members and assessing the contribution of the intumescent coating to the fire resistance, several mechanically loaded fire tests were carried out using a special tension test furnace. The fire tests have shown that intumescent coatings can provide a significant improvement in the fire resistance of steel tension members with hollow section. However, this specific application generally places particularly high demands on the performance of the intumescent coating. This is partly due to the four-sided fire exposure and the mainly filigree cross sections, which both result in high section factors. In addition, there is an increased crack formation due to the tensile load. As a result, the thermal protection of the tested intumescent coating on the tension members decreased compared to columns with the same section factor and fire exposure. Consequently, the presence of a mechanical load in the fire test as well as the type of loading affect the thermal protective performance of the intumescent coating and shall be considered.
It is an essential requirement for all building products to ensure durability of their fire safety. Throughout the working life of products, intumescent coatings are aged by certain climatic factors. To predict a lifetime of several years, generally the behaviour of the intumescent coating is extrapolated based on accelerated artificial ageing. The established German and European procedures to assess the durability assume a working life of at least 10 years. For a longer period, additional evidence is required; yet the procedure and the specifications to justify this are not described. In addition to addressing this formal lack, from a scientific point of view it is necessary to investigate the degradation of intumescent coatings in detail and to propose a reliable test concept to assess durability for more than 10 years. This paper summarises the existing knowledge about the ageing of intumescent coatings. The results of various demanding weathering approaches are presented for two intumescent coatings tested in a joint research project. Moreover, formulations with a reduced amount of functionally relevant components were analysed to gain insight into the associated effects. Derived from these research results and knowledge, recommendations are proposed to assess the durability of intumescent coatings for more than 10 years based on a combination of verifications.
Although intense wildfire research has been done in the US and in Australia, it cannot be transferred directly to the situation in Europe as the local vegetation has a significant influence on the fire spread. The EU-funded project TREEADS and the so-called German pilot within the project are concentrating on wildfire in Europe. Extensive experimental research is done on local vegeta-tion in Germany and the experimental results are used to adjust the Fire Dynam-ics Simulator (FDS) to local vegetation as a fuel in the calculations. The particle model and the boundary fuel model are developed for the simulation of forest fires. Both models require the kinetic input for the dehydration, pyrolysis, and char oxidation process. This three-step simplified model describes the basic fuel combustion kinetic. Most published simulations use the default kinetic input of pine needles from FDS user manual.
To adjust the simulation to local vegetation, the corresponding kinetic parame-ters have been experimental investigated. Samples of pine needles, moss and other falling leaves were collected, air dried and grinded into powder. The TG analysis of all these samples were done under different heating rate of 5, 10 and 20K/min.
The activation energy and the corresponding pre-exponential factor were calcu-lated. The results show that fire spread depends significantly on the vegetation and comparison with small scale experiments show good agreement using the new kinetic parameters. The new model is applied to a larger scenario and will be compared to the results of large-scale experiments for further validation of the model.
Um die Ausbreitungsmechanismen von Vegetationsbränden und besonders bei Bodenbränden besser zu verstehen, wurden die Einflussfaktoren auf die Brandausbreitung näher untersucht. Da die Brandausbreitung auch in starkem Maße von der lokalen Vegetation abhängt, war eine Charakterisierung der lokalen Vegetation und der Bodenverhältnisse wichtig. Die Wetterverhältnisse spielen einerseits im Vorfeld des Brandes durch längere Dürreperioden als auch während des Brandes, z.B. durch den Windeinfluss, zusätzlich eine große Rolle.
Durch die numerische Simulation kann eine größere Variation der Einflussgrößen abgebildet werden als durch die zeitlich und finanziell begrenzten experimentellen Möglichkeiten. Für die Berechnungen wird der Fire Dynamic Simulators (FDS) mit dem Paket WFDS verwendet. Dadurch kann mit einem vereinfachten 3-Phasen-Reaktionskinetikmodell, bestehend aus Dehydrierung, Pyrolyse, Kohleoxidation, die Ausbreitung von Vegetationsbränden verschiedener Waldbodenarten untersucht werden. Es wurden dazu 6 typische Pflanzenarten und Bodenproben aus Kiefern-, Buchen und Eichenbeständen ausgewählt.
Die gesammelten Waldbodenproben wurden alle hinsichtlich des Wassergehalts, des organischen Gehalts, der Packungsdichte, der Dichte und der statistisch ermittelten Pflanzenartenverteilung charakterisiert. Das kinetische Abbrandverhalten wurde durch Thermogravimetrische Analyse (TGA) untersucht. Alle diese Daten wurden als Eingabeparameter für die Simulation verwendet. Die numerischen Simulationen werden mit Experimenten im kleinen, mittleren und Real-Maßstab validiert.
Um die Ausbreitungsmechanismen von Vegetationsbränden und besonders bei Bodenbränden besser zu verstehen, wurden die Einflussfaktoren auf die Brandausbreitung näher untersucht. Da die Brandausbreitung auch in starkem Maße von der lokalen Vegetation abhängt, war eine Charakterisierung der lokalen Vegetation und der Bodenverhältnisse wichtig. Die Wetterverhältnisse spielen einerseits im Vorfeld des Brandes durch längere Dürreperioden als auch während des Brandes, z.B. durch den Windeinfluss, zusätzlich eine große Rolle.
Durch die numerische Simulation kann eine größere Variation der Einflussgrößen abgebildet werden als durch die zeitlich und finanziell begrenzten experimentellen Möglichkeiten. Für die Berechnungen wird der Fire Dynamic Simulators (FDS) mit dem Paket WFDS verwendet. Dadurch kann mit einem vereinfachten 3-Phasen-Reaktionskinetikmodell, bestehend aus Dehydrierung, Pyrolyse, Kohleoxidation, die Ausbreitung von Vegetationsbränden verschiedener Waldbodenarten untersucht werden. Es wurden dazu 6 typische Pflanzenarten und Bodenproben aus Kiefern-, Buchen und Eichenbeständen ausgewählt.
Die gesammelten Waldbodenproben wurden alle hinsichtlich des Wassergehalts, des organischen Gehalts, der Packungsdichte, der Dichte und der statistisch ermittelten Pflanzenartenverteilung charakterisiert. Das kinetische Abbrandverhalten wurde durch Thermogravimetrische Analyse (TGA) untersucht. Alle diese Daten wurden als Eingabeparameter für die Simulation verwendet. Die numerischen Simulationen werden mit Experimenten im kleinen, mittleren und Real-Maßstab validiert.
Although intense wildfire research has been done in the US and in Australia, it cannot be transferred directly to the situation in Europe as the local vegetation has a significant influence on the fire spread. The EU-funded project TREEADS and the so-called German pilot within the project are concentrating on wildfire in Europe. Extensive experimental research is done on local vegeta-tion in Germany and the experimental results are used to adjust the Fire Dynam-ics Simulator (FDS) to local vegetation as a fuel in the calculations. The particle model and the boundary fuel model are developed for the simulation of forest fires. Both models require the kinetic input for the dehydration, pyrolysis, and char oxidation process. This three-step simplified model describes the basic fuel combustion kinetic. Most published simulations use the default kinetic input of pine needles from FDS user manual.
To adjust the simulation to local vegetation, the corresponding kinetic parame-ters have been experimental investigated. Samples of pine needles, moss and other falling leaves were collected, air dried and grinded into powder. The TG analysis of all these samples were done under different heating rate of 5, 10 and 20K/min.
The activation energy and the corresponding pre-exponential factor were calcu-lated. The results show that fire spread depends significantly on the vegetation and comparison with small scale experiments show good agreement using the new kinetic parameters. The new model is applied to a larger scenario and will be compared to the results of large-scale experiments for further validation of the model.
Lecture-like introduction in the topic. Fundamental aspects are discussed: Burning of polymers, fire risks, pyrolysis, combustion in the flame, physical chemistry of ignition, flame spread and steady state burning, flame retardancy mechanisms and groups of flame retardants, fire hazards (smoke, toxic products) and environmental concerns, fire testing.
Sacrifice Few to Save Many: Fire Protective Interlayers in Carbon- Fiber-Reinforced Laminates
(2024)
The fire protection of carbon-fiber-reinforced polymer (CFRP) laminates often relies on flame-retardant coatings, but in some applications, their efficacy may diminish upon direct fire exposure due to rapid pyrolysis. This study introduces an innovative approach by integrating protective interlayers within the laminate structure to enhance the fire resistance. Various materials, including ceramic composite WHIPOX, titanium foil, poly(etherimide) (PEI) foil, basalt fibers, rubber mat, and hemp fibers, were selected as protective interlayers. These interlayers were strategically placed within the laminate layout to form a sacrificial barrier, safeguarding the integrity of the composite. Bench-scale fire resistance tests were conducted, where fire (180 kW/m2) was applied directly to the one side of the specimen by a burner while a compressive load was applied at the same time. Results indicate significant prolongation of time to failure for CFRP laminates with protective interlayers, which is up to 10 times longer. This innovative approach represents a potential advance in fire protection strategies for CFRP laminates, offering improved resilience against fire-induced structural failure.
Several investigation groups have studied the flame-retardancy modes of action and properties of epoxy resins in the past; nevertheless, the selection of suitable flame retardants for epoxy resins remains challenging, and the transfer to fiber composites is difficult. The addition of flame retardants and glass fibers (GFs) to a polymeric system in a fire scenario changes the polymer's pyrolytic path and burning characteristics, reduces the heat released in the combustion, and suppresses the modes of action in the condensed and gas phase. In this study, the thermal analysis, flammability, fire behavior, residue analysis, fire stability, and quantification of modes of action of three different systems with three halogen-free flame retardants (melamine polyphosphate (MPP), ammonium polyphosphate (APP), and silane ammonium polyphosphate (SiAPP)) and three different types of GFs (unidirectional (UD), bidirectional (BD), and woven roving (WR)) will be compared with pure epoxy resin as a reference.
Revolutionizing our polymer industry for adaption to a sustainable carbon circular economy has become one of today’s most demanding challenges. Exploiting renewable resources to replace fossil-fuel—based plastics with biopolymers such as poly(lactic acid) (PLA) is inevitable while using waste streams as a raw material resource at least is promising. When it comes to using PLA as technical polymer, its high flammability must be addressed by flame retardants compatible with the thermoplastic processing of PLA and its compostability. This study proposes microalgae enriched with phosphorus from wastewater (P-Algae) as an elegant way towards a kind of sustainable organophosphorus flame retardant. The concept is demonstrated by investigating the processing, pyrolysis, flammability, and fire behavior of PLA/P-Algae, while varying the P-Algae content and comparing P-Algae with four alternative bio-fillers (phosphorylated lignin, biochar, thermally treated sewage sludge, and metal phytate) with different P-contents as meaningful benchmarks.