Fire Science
Filtern
Dokumenttyp
- Vortrag (146) (entfernen)
Sprache
- Englisch (96)
- Deutsch (47)
- Mehrsprachig (2)
- Tschechisch (1)
Referierte Publikation
- nein (146)
Schlagworte
- Flame retardant (15)
- Behälterversagen (13)
- Alternative Antriebe (9)
- Brandschutz (9)
- Fahrzeugbrand (8)
- Flame retardancy (8)
- Durability (6)
- Flammschutz (6)
- LNG (6)
- LPG (6)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (84)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (65)
- 3 Gefahrgutumschließungen; Energiespeicher (36)
- 3.2 Gefahrguttanks und Unfallmechanik (33)
- 2 Prozess- und Anlagensicherheit (29)
- 2.1 Sicherheit von Energieträgern (28)
- 7.3 Brandingenieurwesen (18)
- 8 Zerstörungsfreie Prüfung (6)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (5)
- 2.2 Prozesssimulation (3)
Eingeladener Vortrag
- nein (146)
Die Präsentation gibt einen Überblick über die Arbeiten im German Pilot des EU-Projekts TREEADS. Es werden klein-, mittel- und großskalige Versuche an Waldboden mit einheimischer Vegetation durchgeführt. Begleitend werden numerische Untersuchungen durchgeführt, die eine Variation der Parameter, wie Bodenfeuchte, Temperaturen und Wind über die Experimente hinaus erlauben. Die gemessenen Materialparameter dienen als Input für die numerischen Berechnungen. Die numerischen Modelle werden mit den mittel- und großskaligen Experimenten validiert.
Weltweit stellen Waldbrände eine große Bedrohung für Umwelt, Wirtschaft und menschliches Leben dar. Der fortschreitende Klimawandel verstärkt Trockenheit und Dürre, wodurch die Größe und Intensität von Waldbränden sowie das daraus resultierende Gefahrenpotential zusätzlich erhöht werden. Um im Risikofall eine schnelle und effektive Waldbrandbekämpfung zu gewährleisten, sollen Einsatzkräfte in Zukunft von KI-basierten Ausbreitungsmodellen unterstützt werden.
Der Einsatz von maschinellem Lernen ermöglicht dabei schnelle und zielgerichtete Ausbreitungsvorhersagen in Echtzeit, die in den Prozess der Brandbekämpfung als zusätzliche Information einfließen können. Im Rahmen des durch das EU-Förderprogram Horizon 2020 finanzierte Projekt TREEADS wird ein solches Modell für Europa entwickelt.
Dazu wird mit verschiedenen Satellitendaten des Copernicus-Programms und der NASA ein auf räumlicher und zeitlicher Ebene aufgelöster Datensatz zu europäischen Waldbränden aufgebaut. Zu den erfassten Waldbränden werden wichtigen Faktoren, die Einfluss auf die Brandausbreitung haben, ergänzt. Dazu gehören das von Copernicus bereitgestellte, digitale Geländemodell Europas und verschiedene, von Sentinel-2 Messungen abgeleitete Informationen zu Vegetation und Landnutzung. Dieser 2D-Trainingsdatensatz zu realen Waldbränden wird durch die zeitlich hochaufgelösten, meteorologischen Reanalyse-Produkte – Copernicus European Regional ReAnalysis (CERRA) und ERA5-Land – vervollständigt und ist die Grundlage für ein Modell zur Ausbreitungsvorhersage von Waldbränden.
Methoden des Maschinellen Lernens können komplexe Muster in den gesammelten Daten erkennen und so zu einer verbesserten Vorhersage der Brandausbreitung beitragen. Die vielfältigen, von Copernicus bereitgestellten Daten sind dabei ein unabdingbarer Bestandteil des Modells, mit dem den Einsatzkräften ein zusätzliches Tool für den effizienten Einsatz ihrer limitierten Ressourcen zur Verfügung steht.
Mit der Abkehr von der Nutzung fossiler Rohstoffe rücken regenerative Energieträger immer weiter in den Focus. Neben klassischen Holzkohlen werden verstärkt so genannte Biokohlen produziert. Dieser Begriff findet Verwendung für mit Hilfe verschiedener Verfahren karbonisierte pflanzliche, tierische oder mikrobielle Ausgangsstoffe. Diese Kohlen werden zum Teil über weite Strecken zum Bestimmungsort transportiert (Überseetransporte) oder vor Verwendung für längere Zeit gelagert.
Häufig zeigen diese Kohlen ein kritisches Selbstentzündungsverhalten, wobei Einstufungstests (UN N.4 Test) versagen können. Ein negatives Testergebnis des UN N.4 Tests führte dabei in der Vergangenheit zur Nichteinstufung als selbsterhitzungsfähiger Stoff; in der Praxis entzündeten sich aber bereits vergleichsweise kleine Schüttungen (einige m³), z. B. beim Seetransport in Containern. Der Artikel geht auf dieses Problem ein und stellt Prüfverfahren vor. Aus den Ergebnissen durchgeführter Untersuchungen werden Empfehlungen für sicheren Transport und Lagerung abgeleitet.
Holzkohlen im Seeverkehr - Selbstentzündung vermeiden, sichere Beförderungsbedingungen schaffen
(2024)
Mit der Abkehr von der Nutzung fossiler Rohstoffe rücken regenerative Energieträger immer weiter in den Focus. Neben klassischen Holz- und Pflanzenkohlen werden verstärkt so genannte Biokohlen produziert. Dieser Begriff findet Verwendung für mit Hilfe verschiedener Verfahren karbonisierte pflanzliche, tierische oder mikrobielle Ausgangsstoffe. Diese Kohlen werden zum Teil über weite Strecken zum Bestimmungsort transportiert (Überseetransporte) oder vor Verwendung für längere Zeit gelagert.
Häufig zeigen diese Kohlen ein kritisches Selbstentzündungsverhalten, wobei Einstufungstests (UN N.4 Test) versagen können. Ein negatives Testergebnis des UN N.4 Tests führte dabei in der Vergangenheit zur Nichteinstufung als selbsterhitzungsfähiger Stoff; in der Praxis entzündeten sich aber bereits vergleichsweise kleine Schüttungen (einige m³), z. B. beim Seetransport in Containern. Ergebnisse eines Projektes zur systematischen Untersuchung verschiedener Pflanzenkohlen werden vorgestellt.
Mit der Abkehr von der Nutzung fossiler Rohstoffe rücken regenerative Energieträger immer weiter in den Focus. Neben klassischen Holzkohlen werden verstärkt so genannte Biokohlen produziert. Dieser Begriff findet Verwendung für mit Hilfe verschiedener Verfahren karbonisierte pflanzliche, tierische oder mikrobielle Ausgangsstoffe. Diese Kohlen werden zum Teil über weite Strecken zum Bestimmungsort transportiert (Überseetransporte) oder vor Verwendung für längere Zeit gelagert.
Häufig zeigen diese Kohlen ein kritisches Selbstentzündungsverhalten, wobei Einstufungstests (UN N.4 Test) versagen können. Ein negatives Testergebnis des UN N.4 Tests führte dabei in der Vergangenheit zur Nichteinstufung als selbsterhitzungsfähiger Stoff; in der Praxis entzündeten sich aber bereits vergleichsweise kleine Schüttungen (einige m³), z. B. beim Seetransport in Containern. Der Artikel geht auf dieses Problem ein, stellt Prüfverfahren vor und gibt Empfehlungen für sicheren Transport und Lagerung.
Leather is a widely used material for thousands of years and in modern days it is produced on industrial scale. This production produces high amounts of organic waste during the tannery process. These fibers can become a resource and act as a multi-functional bio-filler in flame retardant composites.
This project investigates two leather fibers towards their ability to enhance the flame-retardancy in different composites. These composites use ammonium polyphosphate (APP) or aluminum trihydroxide (ATH) as flame retardants. Different silicon based synergists support polymers with ATH to reduce the load of flame retardant. The different modes of action (charring, gas phase activity, barrier effect) can be quantified of each composite.
The new composites form a stable char layer resulting in an increase in residue, lower peak heat release rates (pHRR) and higher limiting oxygen index (LOI). In addition, the ratings in the UL94-classification increased up to V-0.
Short overview is given of BAM's research within the topic "Flame Retardancy of Polymeric Materials". Fire science is identified as a crucial compentenc of BAM following our mission "Safety in Technology and Chemistry". In the area of polymers we work interdisciplinary, in the dimensions from nm to 2m, and we love to combine experiment and simulation. Multimethodical examples are given to describe the burning phenomena and flame-retardant modes of action. Further some examples are presented for tailored bench-scale fire testing and assessing concepts. Our goal is to provide the fundaments for a evidenced-based development of future materials.
For intumescent coatings durability is an important aspect. Due to ageing, which is caused by climatic conditions, the thermal protection performance of intumescent coatings can be reduced during the working life. The national German and the European procedures to assess the durability of intumescent coatings presume a working life of 10 years. For a longer period, additional investigations are required. However, the European assessment procedure does not provide specific information how to prove a durability of more than 10 years. In addition to this formal reason, also from a scientifical position, it is necessary to investigate the degradation of intumescent coatings in detail to propose a corresponding test concept for a durability of more than 10 years.
The presentation summarises the existing knowledge about the degradation behaviour and ageing of intumescent coatings. Furthermore, the results of different approaches from a recently conducted research project are presented. Starting from a water-based and an epoxy-based guide formulation, in a first approach a degradation of the intumescent coating was carried out directly during the production process, i.e. by reducing the concentration of functionally relevant chemical components. In another approach, the duration of the short-term weathering tests was significantly extended, i.e. by multiple repetition of the artificial weathering. The thermal protection performance of the intumescent coating was assessed by fire tests and tests with electrical heating source. In addition, small-scale tests were carried out to determine the thermal material properties of the intumescent coating and thermo-analytical methods were applied to characterise the degradation. Derived from this knowledge, possibilities to test and assess a working life for a period of more than 10 years are proposed.
Leather is a widely used material for thousands of years and in modern days it is produced on industrial scale. This production produces high amounts of organic waste during the tannery process. These fibers can become a resource and act as a multi-functional bio-filler in flame retardant composites.
This project investigates two leather fibers towards their ability to enhance the flame-retardancy in different composites. These composites use ammonium polyphosphate (APP) or aluminum trihydroxide (ATH) as flame retardants. Different synergists support polymers with ATH.
The new composites form a stable char layer resulting in an increase in residue, lower peak heat release rates (pHRR) and higher limiting oxygen index (LOI). In addition, the ratings in the UL94-classification increased up to V-0.
Avoiding antimony – effect of Ca(H2PO2)2 on smoke emission and fire behaviour in brominated ABS
(2023)
The replacement of antimony trioxide (Sb2O3) in brominated flame-retardant ABS (ABS/FR) is of great interest. This study investigates the influence of calcium hypophosphite (CaP) in ABS/FR on flame retardancy and smoke emission. Different amounts of talc are added to ABS/FR/CaP to evaluate the influence of an inorganic barrier on smoke emission and flame retardancy. The cone calorimeter unveiled a reduction by 46% in PHRR for ABS/FR/CaP. Additional 8 wt.-% talc (ABS/FR/CaP/8Talc) reduced the PHRR by 61%. ABS/FR/CaP exhibited a more condensed phase action, which resulted in less smoke emission. The study investigates the influence of CaP in ABS/FR on the smoke toxicity, smoke density and the smoke particles distribution in the smoke density chamber (ISO 5659-2) coupled to a FTIR spectrometer and electrical low pressure cascade impactor (ELPI).
Der Beitrag beschreibt die Entwicklung eines neuartigen in situ Nachweisverfahrens zur Beurteilung des Feuerwiderstandes von bestehenden Stahlkonstruktionen mit gealtertem reaktivem Brandschutzsystem (RBS). Derzeit ist ein solcher Nachweis ausschließlich anhand eines Bauteilbrandversuchs möglich. Hierzu muss ein Bauteil aus der Bestandskonstruktion entnommen und einer zerstörenden Brandprüfung unterzogen werden. In Zusammenhang mit der Dauerhaftigkeitsbewertung von RBS für Zeiträume von mehr als 10 Jahren besteht in der Praxis vermehrt der Bedarf an einem minimal invasiven Prüfverfahren, mit dessen Hilfe sich direkt am Bestandsbauwerk die tatsächlich vorhandene Leistungsfähigkeit des gealterten RBS überprüfen lässt. Durch einen erfolgreichen Funktionsnachweis wäre eine Weiternutzung der Bestandkonstruktion bei Aufrechterhaltung des bestehenden Sicherheitsniveaus möglich.
The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure.
What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank.
The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires.
The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures.
Fire resistance testing of components made of carbon fibre reinforced polymers (CFRP) composites usually demands intermediate-scale or full-scale testing. In this study, a bench-scale test is presented as a practicable and efficient method to assess the improvement in structural integrity of CFRP with different protective interlayers during fire.
Fire stability is one of the biggest issues of carbon fibre reinforced polymer (CFRP) composites, particularly when they are using in load bearing applications. As soon as the glass transition temperature of polymer matrix (100-200°C) is achieved, the composite loses its structural integrity, what leads to the distortion and failure. The principal fire stability test is based on simultaneous application of fire and mechanical load. Since the carbon fibres can transfer the tensile loads quite well, the compression load is chosen as a required mechanical load for a test. The fire tests were preceded by a static load test at room temperature to determine ultimate failure load. The specimen was loaded with a compression force until the failure load was reached, which was observed as a buckling. For the fire tests, 10% of compression failure load and direct flame of a fully developed fire (heat flux ≈ 180 kW m-2) were applied simultaneously to the specimen, while the time to failure was measured.
The possibilities of bench-scale fire stability testing were presented by investigating new types of laminate structures, which exhibit promising flame retardancy and fireproof properties. The new approach of CFRP laminate differs with a protective concept. Every system consists of two different interlayers (titanium foil, thermoplastic foil PEI, ceramic layer WHIPOX, rubber tape Pyrostat, basalt fibres and kenaf fibres), where the one layer constitutes the fireproof protection, that delays the rise of temperature in the rest of laminate, and the second layer provides very good structural connection with carbon fibre layers, thus improves the mechanical integrity of CFRP composite in fire.
The time to failure of CFRP composite was 17s. Protective systems significantly enhance the fire stability and increased time to failure by 3 to 10 times. Thicker specimens showed longer resistance time, however CFRP laminate with ceramic layer and titanium foil presented outstanding results and the best performance. The protection with Kenaf and basalt fibres offered a natural fibre solution with also good fire resistance performance
Although bench-scale tests are limited with respect to assessing the performance of components and structures, they are valuable in the assessment of different materials concepts. Furthermore, the reduced effort of conducting bench-scale test (lower costs, time, personnel resources) makes it more practical and effective.
Hydrogen is among the most promising candidates to replace fossil fuels in the energy transition. Hydrogen-powered vehicles are already a reality, and their number is foreseen to increase considerably in the next decade. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) appear to be one of the most effective to ensure high volumetric energy density. A potential loss of integrity of this kind of storage equipment might lead to severe consequences due to high flammability of hydrogen. This might occur, for instance, as a consequence of the exposure to an external source of heat such as a fire following a car accident. Real scale fire test results suggest that the super insulating performance of MLI systems may undergo severe degradation when this is subjected to high temperature, leaving the tank almost unprotected and leading to failure in a relatively short time. Characterizing this kind of accident scenario is crucial to ensure a safe design of storage tanks for Hydrogen-powered vehicles.
This presentation provides an overview of the ongoing research work on modelling MLI LH2 tanks exposed to fire. Lumped and computational fluid dynamic based models are presented, highlighting current gaps. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis case studies.
Main message: Sustainability, or in other words, exploiting environmental conservation for the economic welfare and prosperity for all, would revolutionise the plastics industry were it to become predominant practice as a linear, fossil-fuel–based economy is switched to a carbon circular economy. Food for though is given by dint of a critical overview of the current trends in sustainable flame-retardant polymeric materials.
Introduction:
Transforming the plastics industry into a carbon circular economy over the next 30 years requires an immediate revolution entailing the development of cutting-edge materials and the planning of future industrial production plants. Hence, the innovative field of flame-retardant polymeric materials should lend its strength to drive this challenge. Visionary solutions are proposed to inspire us, while the implementation of economically feasible concepts can take us forward into the future.
Experimental The synthesis, processing, polymer analysis, thermal analysis, and investigation of fire behaviour from our own research are performed according to the state of the art, mostly in accordance with the pertinent ISO standards. Indeed, some of our equipment is part of the accredited lab; for the other methods we fulfil equivalent quality standards in terms of maintenance, calibration, participation in round robins, etc. Work steps such as the synthesis or preparation of new materials are usually outsourced or done with partners that have the relevant core competence. The talk also presents examples from other groups whose experimental is described in the corresponding scientific papers.
Results and Discussion An overview of current trends towards producing sustainable, flame-retardant polymeric materials is presented, using examples from the literature and by sketching our own projects performed in recent years. The examples are structured along a common theme leading from the use of old and new natural materials with some intrinsic flame retardancy, via flame-retardant biopolymers and biocomposites, to using renewable sources for flame retardants with the objective of exploiting natural sources available as industrial waste streams. Natural flame retardants and adjuvants are highlighted, although the status of most may be assessed as merely motivating our vision. Nevertheless, there are natural material streams finding their way into polymer mass production as fillers, adjuvants, polymers, or renewable educt sources. Natural substances originating from industrial waste streams open the door to sustainable solutions, because they are often available at low cost and avoid competition for land with farming or virgin forests. Aside from this main topic, remarks will address the recycling of flame-retarded polymeric materials; vitrimers are mentioned as a potential material for recyclable thermosets. At the end of the day, only convincing property profiles will prevail both for exploiting renewable sources and circular design, including cost effectiveness, sufficient availability, consistent quality, processibility, mechanical properties, and flame retardancy. However, sustainability must not be merely tolerated as an additional demand, but should instead be recognized as a solution, because sustainability aspires to ensure our economic welfare now and in the future.
Acknowledgement:
The examples shown from own project were supported by funding grants: BMBF WTZ: 01DN16040, DFG Scha 730/19-1, VW-Stiftung: Experiment No: 97437, DFG Scha 730/20-1, BMBF KMU Innovativ 031B1289B.
A few layer/multilayer graphene (MLG) with a specific surface area of BET ≥ 250 m2/g is proposed as an efficient multifunctional nanofiller for rubbers. The preparation method, i.e., ultrasonically-assisted solution or latex premixing of master batches followed by conventional two-roll milling, strongly influences the dispersion in the elastomeric matrix and is fundamental for the final properties. When homogenously dispersed, single stacks of only approximately 10 graphene sheets, with an aspect ratio of ca. 35, work at low loadings, enabling the replacement of large amounts of carbon black (CB), an increase in efficiency, and a reduction in filler load. The appropriate preparation yielded nanocomposites in which just 3 phr are sufficient to significantly improve the rheological, curing, gas barrier properties, electrical and thermal conductivity, as well as mechanical properties of different rubbers, as shown for chlorine-Isobutylene-Isoprene rubber (CIIR), nitrile-butadiene rubber (NBR), natural rubber (NR), and styrene-butadiene rubber (SBR).[1-5] 3 phr of MLG tripled the Young’s modulus of CIIR, an effect equivalent to 20 phr of CB. The stronger interactions between MLG and NR or SBR also resulted in a reduction in the elongation at break by 20% and 50%, respectively, while the same parameter was hardly changed for CIIR/MLG and NBR/MLG. CIIR/MLG and NBR/MLG were stiffer but just as defomable than CIIR and NBR. The strong reinforcing effect of 3 phr MLG was confirmed by the increase of greater than 10 Shore A in hardness. MLG reduces gas permeability, increases thermal and electrical conductivities, and retards flammability. We investigated MLG also as a synergist for reducing the aluminium trihydrate loading in flame retardant hydrogenated acrylonitrile-butadiene (HNBR), polybutadiene chloroprene (BR/CR), and chlorosulfonated polyethylene rubber(CSM).[6-8] The higher the nanofiller concentration is, the greater the improvement in the properties. For instance, the permeability decreased by 30% at 3 phr of MLG, 50% at 5 phr and 60% at 10 phr, respectively. Moreover, the MLG nanocomposites improve stability of mechanical properties against the effects of weathering. In key experiments an increase in UV-absorption and a pronounced radical scavenging were proved as stabilizing mechanisms. In a nutshell, MLG is an efficient multifunctional nanofiller ready to be used for innovative rubber development.
Das EU Projekt EU FireStat SI2.830108, das vom Europäischen Parlament finanziert und von der DG GROW der Europäischen Kommission in Auftrag gegeben wurde, hat aufgearbeitet, welche Terminologie in den europäische Mitgliedsstaaten verwendet wird und die von den Mitgliedstaaten erhobenen Daten über Gebäudebrände zu analysieren. Dabei wurden die Schwierigkeiten bei der Erfassung und die Unterschiede bei der Auslegung ermittelt und eine gemeinsame Terminologie sowie eine Methode zur Erfassung der erforderlichen Daten vorgeschlagen.
Folgende Schwerpunkte wurden bearbeitet: Zunächst erfolgte eine Diagnose von Terminologie-, Datenerhebungs- und Auslegungsproblemen, Erhebung der Terminologie und der Datenerfassung, Identifizierung der für die Entscheidungsfindung benötigten Daten, Analyse der Methoden zur Datenerhebung Definition einer gemeinsamen Terminologie, Methodik der Kosten-/Nutzenbewertung zur Unterstützung politischer Entscheidungen, Fallstudie zur Anwendung der Methode der Kosten-/Nutzenbewertung, Beschreibung einer zukünftigen Datenerhebungsmethode.
Das Ergebnis des Projekts ist eine Empfehlung, welche Daten in den Mitgliedstaaten erhoben werden sollten, um wissensbasierte Entscheidungen in Bezug auf den Brandschutz zu ermöglichen. Damit wird die Grundlage für Maßnahmen und Initiativen geschaffen, die den Brandschutz und die Brandverhütung der Mitgliedstaaten unterstützen, so dass knappe Ressourcen gezielt eingesetzt werden können.
We are interested in accidental fire impingement of HazMat pressure vessels. Want to develop improved models for predicting time to failure or empty (if PRV present). We are still trying to properly predict pressurization and time to first PRV activation due to liquid temperature stratification for a range of fire scenarios (Full and partial engulfing pool fire, jet fires, with roll over, with TP defects, etc.)
The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire.