Fire Science
Filtern
Dokumenttyp
- Vortrag (158)
- Zeitschriftenartikel (152)
- Beitrag zu einem Tagungsband (59)
- Posterpräsentation (32)
- Buchkapitel (20)
- Beitrag zu einem Sammelband (3)
- Dissertation (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (2)
- Forschungsbericht (2)
Sprache
- Englisch (337)
- Deutsch (94)
- Tschechisch (2)
- Mehrsprachig (2)
Schlagworte
- Flame retardant (36)
- Flame retardancy (29)
- Brandschutz (24)
- Behälterversagen (17)
- Fire resistance (14)
- Fire test (13)
- Flammability (13)
- Feuerwiderstand (12)
- Fire (12)
- LNG (12)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (279)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (212)
- 3 Gefahrgutumschließungen; Energiespeicher (89)
- 3.2 Gefahrguttanks und Unfallmechanik (83)
- 2 Prozess- und Anlagensicherheit (76)
- 2.1 Sicherheit von Energieträgern (74)
- 7.3 Brandingenieurwesen (64)
- 8 Zerstörungsfreie Prüfung (18)
- 7.1 Baustoffe (14)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (12)
Paper des Monats
- ja (7)
The recommendation is based on the coauthors’ work organized by the RILEM TC 256-SPF ‘‘Spalling of concrete due to fire: testing and modelling’’. The Committee has defined two types of screening tests for characterization of concrete propensity to fire spalling: Material screening tests and Product screening tests. Definitions of both types of tests are given in the paper. The following recommendations apply to Material screening tests. The material screening tests described in these recommendations are a set of minimum requirements to test concrete spalling propensity (for example, the minimal specimen size). This document covers the aspects of concrete characterization, specimen geometries, storage conditions, test methods and measured parameters.
Since we are facing more extreme weathers, the occurrence
of wildfire has also increased accordingly. The EU project
TREEADS aims to adopt a holistic forest fire management
and an adaptive, collaborative governance approach based
on the deployment of a new systemic and technological
framework covering all three interconnected fire
management stages: prevention & preparedness, detection &
response, and restoration & adaptation.
As part of the task in the so-called German pilot, numerical
simulations are performed to investigate the influencing
factors for vegetation fires with fire dynamics simulator
(FDS). The characteristics of vegetation are strongly related
to the local weather and ecosystem. The investigation of the
fire behavior of vegetation must be based on the local
vegetation in Germany. Thus, the flame propagation of typical
vegetation in Germany (pine needles, oak leaves, European
beech leaves etc.) was investigated in small scale and medium
scale experiments. These results are used as validation case
studies for the further simulations.
Revolutionizing our polymer industry for adaption to a sustainable carbon circular economy has become one of today’s most demanding challenges. Exploiting renewable resources to replace fossil-fuel—based plastics with biopolymers such as poly(lactic acid) (PLA) is inevitable while using waste streams as a raw material resource at least is promising. When it comes to using PLA as technical polymer, its high flammability must be addressed by flame retardants compatible with the thermoplastic processing of PLA and its compostability. This study proposes microalgae enriched with phosphorus from wastewater (P-Algae) as an elegant way towards a kind of sustainable organophosphorus flame retardant. The concept is demonstrated by investigating the processing, pyrolysis, flammability, and fire behavior of PLA/P-Algae, while varying the P-Algae content and comparing P-Algae with four alternative bio-fillers (phosphorylated lignin, biochar, thermally treated sewage sludge, and metal phytate) with different P-contents as meaningful benchmarks.
The synergistic behavior of different silicon compounds is investigated in flame retardant biocomposites with aluminum trihydroxide (ATH) as the main flame retardant. The paper shows a new approach towards sustainable biocomposites through the implementation of thermoplastic starch (TPS), leather fibers from industrial waste streams, and non-hazardous flame retardants and synergists. In these multicomponent systems, the different components address different modes of action in the fire scenario. When ATH is partially substituted by glass frits or layered silicates, fire performance is enhanced without changing the total amount of filler in the polymer. In a biocomposite with 25 phr of fiber and 90 phr of ATH, substituting 5 phr of ATH for layered silicates increased the LOI from 31.5 vol % to 34.8 vol %, decreased the peak of heat release by 20%, and increased the UL 94 rating from V-1 to V-0.
The global plastic industry relies on fossil-based materials, presenting environmental challenges. A sustainable polymer namely poly(limonene carbonate) (PLimC), made of limonene and CO2 as two monomers from non-food sources, shows advances in various applications where additives such as flame retardants (FRs) are crucial to comply with fire safety measures.
The variety of FRs is wide, and therefore the approach involved conducting a comparative study of four different halogen-free flame retardant systems that are conventionally used in polycarbonates and polyolefins to understand which FR enhances the flame resistance of PLimC most effectively. The primary task of the project is to conduct experimental evaluations to analyze the thermal properties, flammability, and fire behavior of each system. This data will offer valuable insights towards the advancement of safer and more sustainable materials.
Fire-induced spalling of normal strength concrete with different types of blended Portland cement
(2024)
The cement industry is looking to reduce its overall CO2 footprint. Greener manufacturing can be achieved by the introduction of more clinker-reduced cements. Concrete exposed to fire tends to show explosive spalling caused by thermomechanical and thermohydraulic processes. It is therefore essential to determine how concretes with clinker-reduced cements behave under fire exposure, especially for concretes containing calcined clays, as these are expected to be the supplementary cementitious material of the future. In this paper, normal strength concretes with four different cements (CEM I, CEM II/A-LL, CEM III/A and CEM II/B-Q) were examined for their fire-induced spalling behaviour. In addition, a mix with PP fibres was investigated for each concrete. The experiments were conducted on ring-restrained cylindrical specimens exposed to the hydrocarbon fire curve. The results showed that the cement type influences spalling behaviour. Samples with CEM I spalled the least, followed by CEM II/A-LL and CEM III/A. Finally, samples with CEM II/B-Q showed the most severe damage. It was found that the spalling behaviour of different concretes correlates with the moisture content before exposure to fire, meaning that higher moisture content leads to higher spalling susceptibility. The use of 2 kg/m³ PP fibres completely inhibited spalling regardless of the cement type used and therefore remains a successful avoidance strategy.
The systematic transfer of solvent-free, additive flame retardant (FR) formulations from epoxy resins to glass fiber-reinforced epoxy composites (GFRECs) through prepregs is difficult. Additionally, obtaining data on their post-fire mechanics is often challenging. Utilizing melamine polyphosphate (MPP), ammonium polyphosphate (APP), and silane-coated ammonium polyphosphate (SiAPP) FRs with low-melting inorganic silicates (InSi) in an 8:2 proportion and 10% loading by weight in a diglycidyl ether of bisphenol A (DGEBA) resin, a systematic investigation of the processing properties, room-temperature mechanics, and temperature-based mechanics of the systems was performed. The resin was cured with a dicyandiamide hardener (DICY) and a urone accelerator. The results revealed no substantial impact of these FRs at the current loading on the resin's glass transition temperature or processability. However, the fire residues from cone calorimetry tests of the composites containing FRs were found to be only 15-20% of the thickness of the resins, implying a suppression of intumescence upon transfer. At room temperature, the decrease in the flexural modulus for the composites containing FRs was negligible. Exposure of the composites in a furnace at 400°C as a preliminary study before ignition tests was shown to cause significant flexural moduli reductions after 2.5 min of exposure and complete delamination after 3 min making further testing unviable. This study emphasizes the need for future research on recovering modes of action upon transfer of FR formulations from resins to composites. Based on the challenges outlined in this investigation, sample adaptation methods for post-fire analysis will be developed in a future study.
Cryogenic liquefied gases, such as liquid hydrogen (LH2) and liquefied natural gas (LNG), are becoming more popular as eco-friendly energy sources. However, using these gases more often increases the risk of accidents, making it important to conduct thorough risk assessments. The storage systems for these gases rely on thermal superinsulation (TSI), which can fail under extreme heat, especially during fires. Therefore, it is essential to study how and why TSI fails. This research (part of PhD topic) aims to examine insulation performance, thereby improving the overall safety of cryogenic storage systems.
Revolutionizing our polymer industry for adaption to a sustainable carbon circular economy has become one of today’s most demanding challenges. Exploiting renewable resources to replace fossil-fuel—based plastics with biopolymers such as poly(lactic acid) (PLA) is inevitable while using waste streams as a raw material resource at least is promising. When it comes to using PLA as technical polymer, its high flammability must be addressed by flame retardants compatible with the thermoplastic processing of PLA and its compostability. This study proposes microalgae enriched with phosphorus from wastewater (P-Algae) as an elegant way towards a kind of sustainable organophosphorus flame retardant. The concept is demonstrated by investigating the processing, pyrolysis, flammability, and fire behavior of PLA/P-Algae, while varying the P-Algae content and comparing P-Algae with four alternative bio-fillers (phosphorylated lignin, biochar, thermally treated sewage sludge, and metal phytate) with different P-contents as meaningful benchmarks.
Steel tension members with hollow sections are used in applications such as trusses. To ensure the fire resistance, the steel must be prevented from heating up too quickly. A suitable solution is the application of intumescent coatings. However, the approval-based scope of application of these products generally does not include steel tension members with hollow section. This is mainly due to the lack of a corresponding European test and assessment standard. To investigate the characteristics to be considered when testing these structural members and assessing the contribution of the intumescent coating to the fire resistance, several mechanically loaded fire tests were carried out using a special tension test furnace. The fire tests have shown that intumescent coatings can provide a significant improvement in the fire resistance of steel tension members with hollow section. However, this specific application generally places particularly high demands on the performance of the intumescent coating. This is partly due to the four-sided fire exposure and the mainly filigree cross sections, which both result in high section factors. In addition, there is an increased crack formation due to the tensile load. As a result, the thermal protection of the tested intumescent coating on the tension members decreased compared to columns with the same section factor and fire exposure. Consequently, the presence of a mechanical load in the fire test as well as the type of loading affect the thermal protective performance of the intumescent coating and shall be considered.