Fire Science
Filtern
Dokumenttyp
- Zeitschriftenartikel (12)
- Beitrag zu einem Tagungsband (5)
- Vortrag (4)
- Forschungsbericht (2)
- Buchkapitel (1)
- Posterpräsentation (1)
Schlagworte
- Brandschutz (13)
- Feuerwiderstand (8)
- Brandversuche (7)
- Reaktive Brandschutzsysteme (7)
- Stahl (7)
- Steel (6)
- Intumescent coating (5)
- Reaktives Brandschutzsystem (5)
- Reactive fire protection system (4)
- Brandversuch (3)
- Dauerhaftigkeit (3)
- Fire test (3)
- Tension rod system (3)
- Alterung (2)
- Intumescent fire protection coating (2)
- Intumeszierende Beschichtung (2)
- Real-scale fire test (2)
- Zugglied (2)
- Behälter (1)
- Beton (1)
- Carbon (1)
- Carbonzugglied (1)
- Coating (1)
- Computed tomography (1)
- Dauerhafigkeit (1)
- Durability (1)
- Fire protection (1)
- Fire resistance (1)
- Fire tests (1)
- Heating curves (1)
- Instandhaltung (1)
- Intumescence (1)
- Netzwerkbogenbrücke (1)
- Normung (1)
- Oberflächenkrümmung (1)
- Prüfmethode (1)
- Prüfnorm (1)
- Querdehnungsbehinderung (1)
- Residue morphology (1)
- Small scale (1)
- Spannbeton-Hohlplatten (1)
- Stahlbau (1)
- Stahlbauteile (1)
- Stahlzugglieder (1)
- Steel tension member (1)
- Tension member (1)
- Tension members (1)
- Test standard (1)
- Zugglieder (1)
- Zugstabsystem (1)
- Zulassung (1)
- Zwängung (1)
- reaktives Brandschutzsystem (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (4)
Der Beitrag beschreibt die Entwicklung eines neuartigen in situ Nachweisverfahrens zur Beurteilung des Feuerwiderstandes von bestehenden Stahlkonstruktionen mit gealtertem reaktivem Brandschutzsystem (RBS). Derzeit ist ein solcher Nachweis ausschließlich anhand eines Bauteilbrandversuchs möglich. Hierzu muss ein Bauteil aus der Bestandskonstruktion entnommen und einer zerstörenden Brandprüfung unterzogen werden. In Zusammenhang mit der Dauerhaftigkeitsbewertung von RBS für Zeiträume von mehr als 10 Jahren besteht in der Praxis vermehrt der Bedarf an einem minimal invasiven Prüfverfahren, mit dessen Hilfe sich direkt am Bestandsbauwerk die tatsächlich vorhandene Leistungsfähigkeit des gealterten RBS überprüfen lässt. Durch einen erfolgreichen Funktionsnachweis wäre eine Weiternutzung der Bestandkonstruktion bei Aufrechterhaltung des bestehenden Sicherheitsniveaus möglich.
Die Anwendung von Zuggliedern aus Carbon ist durch die außergewöhnlich gute Ermüdungs- sowie hohe Zugfestigkeit des Werkstoffs motiviert. Ferner ergibt sich gegenüber Stahl eine deutliche Reduzierung des Querschnitts. Perspektivisch sollen damit u. a. Stahlzugglieder im Netzwerkbogenbrückenbau ersetzt werden. Das Tragverhalten von Carbonzuggliedern im Brandfall ist jedoch bislang unbekannt. Daher wurden mittels Bauteilbrandversuchen die Versagensmechanismen untersucht sowie anhand gewonnener Versuchsdaten eine exemplarische Einschätzung zur Gleichwertigkeit gegenüber konventionellen Stahlzuggliedern vorgenommen. Der Beitrag beschreibt realmaßstäbliche Brandversuche an mechanisch belasteten Carbonzuggliedern, die im Rahmen des Verbundforschungsvorhabens NeZuCa durchgeführt wurden. Das Versuchsprogramm umfasste vier Carbonzugglieder mit kreisrunden Querschnitten in zwei verschiedenen Durchmessern, 36 mm und 51 mm. In Ermangelung eines präskriptiven Brandszenarios für den im Projekt vorgesehenen Anwendungsfall und aus Gründen der Vergleichbarkeit erfolgte die Brandbeanspruchung nach Einheitstemperaturzeitkurve (ETK). Neben den Längsverformungen der Zugglieder wurden auch die Bauteil und Brandraumtemperaturen aufgezeichnet.
Ziel des Forschungsvorhabens ist es, ein standardisiertes Prüf- und Bewertungsverfahren zur Bestimmung des Beitrags reaktiver Brandschutzsysteme (RBS) zum Feuerwiderstand von Stahlzuggliedern zu erarbeiten und dieses in ein Entwurfsdokument für eine europäische Prüfnorm zu überführen. Hierzu wurden einerseits bereits vorhandene Erfahrungen und Erkenntnisse genutzt und andererseits mittels Brandversuchen neue Prüfdaten zur Beantwortung bisher offengebliebener Aspekte zum Einfluss der Bauteilorientierung und Profilart erzeugt und ausgewertet. Dadurch wird die prüftechnische Grundlage für eine sichere, zulassungsbasierte Anwendung von reaktiven Brandschutzsystemen auf zugbeanspruchten Stahlbauteilen gelegt und ein einheitliches Sicherheitsniveau etabliert.
Der im Rahmen des Forschungsprojektes entwickelte Normentwurf wurde mit den Fachexperten der zuständigen nationalen und europäischen Normungsgremien diskutiert und abgestimmt. Das erarbeitete Prüf- und Auswertungsverfahren basiert auf der Durchführung von Brandversuchen an mechanisch belasteten Stahlzuggliedern mit RBS. Ergänzend sind unbelastete Brandversuche zur Beurteilung des Einflusses der Bauteilorientierung sowie der Eignung bei Schwelbrandbeanspruchung möglich. Die im Projekt durchgeführten experimentellen Untersuchungen liefern die Grundlage für den im Normenentwurf vorgeschlagenen Prüfaufbau der mechanisch belasteten und unbelasteten Brandversuche. Ferner konnte durch die Untersuchungen gezeigt werden, dass sich unter bestimmten Voraussetzungen die Prüfergebnisse von Stahlzuggliedern mit Kreisvollprofil ohne zusätzliche Brandversuche auf entsprechende Zugglieder mit Rechteckvollprofil übertragen lassen. Darüber hinaus konnte belegt werden, dass die Leistungsfähigkeit eines RBS aufgrund unterschiedlicher Bauteilorientierungen abnehmen kann und daher zwingend beim Anwendungsbereich des RBS zu berücksichtigen ist. Hierzu wird ein Temperaturdifferenz-kriterium vorgeschlagen, bei dessen Einhaltung die Wirksamkeit des RBS bei von der horizontalen Referenzorientierung abweichenden Bauteilneigungen noch gleichwertig gegeben ist. Andernfalls bietet der Normenentwurf die Möglichkeit die reduzierte thermische Schutzwirkung des RBS im Assessment zu berücksichtigen.
Die Ergebnisse aus dem Forschungsvorhaben wurden bereits auf einem wissenschaftlichen Symposium vorgestellt sowie in einer referierten Fachzeitschrift publiziert. Ferner wurden die Informationen zum Forschungsprojekt und dem Normenentwurf im Rahmen eines Anwenderworkshops interessierten Kreisen zugänglich gemacht. Der im Projekt ausgearbeitete Normenentwurf wird dem zuständigen europäischen Normungsgremien, CEN/TC 127/WG 1, zur Verfügung gestellt und dort zur Abstimmung gestellt.
For intumescent coatings durability is an important aspect. Due to ageing, which is caused by climatic conditions, the thermal protection performance of intumescent coatings can be reduced during the working life. The national German and the European procedures to assess the durability of intumescent coatings presume a working life of 10 years. For a longer period, additional investigations are required. However, the European assessment procedure does not provide specific information how to prove a durability of more than 10 years. In addition to this formal reason, also from a scientifical position, it is necessary to investigate the degradation of intumescent coatings in detail to propose a corresponding test concept for a durability of more than 10 years.
The presentation summarises the existing knowledge about the degradation behaviour and ageing of intumescent coatings. Furthermore, the results of different approaches from a recently conducted research project are presented. Starting from a water-based and an epoxy-based guide formulation, in a first approach a degradation of the intumescent coating was carried out directly during the production process, i.e. by reducing the concentration of functionally relevant chemical components. In another approach, the duration of the short-term weathering tests was significantly extended, i.e. by multiple repetition of the artificial weathering. The thermal protection performance of the intumescent coating was assessed by fire tests and tests with electrical heating source. In addition, small-scale tests were carried out to determine the thermal material properties of the intumescent coating and thermo-analytical methods were applied to characterise the degradation. Derived from this knowledge, possibilities to test and assess a working life for a period of more than 10 years are proposed.
Intumescent fire protection coatings are used to improve the fire resistance of steel members. Due to slender cross-sections typically used for tension members, high demands are placed on the effectiveness and reliability of the intumescent coatings. This paper describes real-scale fire tests of intumescent coatings applied to steel tension members with circular solid and hollow sections. First, the current regulations for the application of intumescent coatings on steel tension members are discussed. After that, a comparison between the foaming behaviour and failure mechanisms of intumescent coatings applied to steel tension members with different cross-sections and loading conditions is given. Next, the experimental setup and procedure of the performed fire tests are presented. In addition, the influences of various parameters on the performance of the intumescent coating are analysed, including the geometry of the steel profile, dry film thickness of the intumescent coating, load utilisation level as well as the orientation of the member. Based on the theoretical considerations and results of the fire tests, it is evidenced that mechanically loaded fire tests are essential to assess accurately the contribution of intumescent fire protection coatings to the fire resistance of steel tension members with circular solid sections.
Intumescent coatings are commonly used in civil engineering to improve the fire resistance of steel constructions. Especially in the case of tension bars, where mostly circular or rectangular solid sections are used, intumescent coatings offer an efficient measure to improve the fire resistance taking advantage of profile-following application and low coating thickness requirements. Thus, the architectural appearance of slender profiles can be preserved. The paper describes real-scale mechanically loaded and unloaded fire tests of circular and rectangular solid steel tension bars with intumescent coating. The aim of these tests is to investigate the influence of the different profile types as well as different bar orientations on the performance of intumescent coatings. The results are used to specify a normative test and assessment procedure to be implemented in a new European standard for determining the contribution of intumescent coatings to the fire resistance of circular or rectangular bars used as tension members.
Reaktive Brandschutzsysteme
(2022)
Die Erkenntnisse zu reaktiven Brandschutzsystemen (RBS) werden kontinuierlich erweitert, was sich in der Entwicklung neuer Produkte und der Ausweitung des durch technische Regelungen abgedeckten Anwendungsbereichs äußert. Der vorliegende Beitrag konzentriert sich auf die Verwendung von RBS auf Stahlkonstruktionen. Neben einer umfassenden Darstellung der aktuellen nationalen und europäischen Regelungen zu RBS, werden technologische Besonderheiten und deren Einfluss auf den Regelungsinhalt im Beitrag thematisiert. Dabei werden neben sich abzeichnenden Neuerungen auch die entsprechenden wissenschaftlich-technologischen Grundlagen dargelegt. Ferner wird die Frage nach der Bewertung der Dauerhaftigkeit von RBS für deutlich über 10 Jahre hinausgehende Zeiträume, und den sich damit einstellenden Feuerwiderstand der Konstruktion behandelt. Der Beitrag schließt mit einer Darstellung zur aktuellen Forschung. Daraus abgeleitet wird ein Ausblick auf zukünftige Forschungsthemen.
Intumescent coatings are used in civil engineering to improve the fire resistance of steel constructions. Due to the thin coating thickness and the profile-following application, the architectural appearance of the steel structure can be preserved. EN 13381-8 provides regulations to determine the contribution to the fire resistance of intumescent coatings applied to steel beams and columns. The scope of this standard excludes tension members and steel members with solid sections. For products that have already been successfully tested and assessed on beams and columns, EN 13381-10 offers the possibility based on unloaded fire tests to extend the scope of application of intumescent coatings to tension bars with solid sections. This approach contradicts the national safety level in Germany, where mechanically loaded testing is mandatory. Therefore, a new part of the test standard series EN 13381 is currently developed to enable the application of intumescent coatings on steel tension bars with solid section based on mechanically loaded fire tests. BAM has already carried out numerous fire tests on loaded steel tension members with intumescent coatings. Currently, in the BAM research project FIRESTEMIC, the influence of the steel bar orientation and the profile type on the thermal performance of intumescent coatings are investigated. Both questions concerning the thermal protection ability of intumescent coatings were analysed based on three different test sets, which were carried out in the tension furnace (Fig. 1a). The fire exposure corresponds to the standard temperature-time curve according to EN 1363-1.
This paper summarises the main findings from the fire tests conducted in the FIRESTEMIC project. The results serve as an experimental background for the proposal of the new standard. Regarding the bar orientation, a new test setup was developed and proposed for the new standard. The two tested commercial water-based intumescent coatings with applied dry film thickness from 1.5 mm to 2.5 mm showed only a slight dependence on the bar orientation. In terms of the steel profile type, circular and rectangular solid sections with identical section factor and applied dry film thickness were tested. It was observed that the circular solid bars with diameter 30 mm heat up faster compared to the solid rectangular bars with dimension 30×30 mm (Fig. 1b). Also at larger steel bars, i.e. diameter 40 mm and dimension 40×40 mm, the same trend occurred. Thus, it is recommended for the new test standard to allow a transfer of the test results from circular to rectangular solid sections. In addition, the paper will describe and explain the test and assessment procedure proposed for the newly developed standard.