Infrastruktur
Filtern
Dokumenttyp
- Vortrag (120)
- Beitrag zu einem Tagungsband (69)
- Zeitschriftenartikel (50)
- Posterpräsentation (9)
- Dissertation (4)
- Beitrag zu einem Sammelband (3)
- Buchkapitel (2)
- Sonstiges (2)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
Schlagworte
- Ground vibration (19)
- Structural Health Monitoring (19)
- Structural health monitoring (14)
- Brücken (11)
- Monitoring (11)
- Hammer impact (9)
- Impact (9)
- Train passage (9)
- Damage characterization (8)
- Fatigue (8)
Organisationseinheit der BAM
- 7.2 Ingenieurbau (260) (entfernen)
Paper des Monats
- ja (3)
Protection against terrorist or accidental scenarios in industrial settings requires suitable designs of structures to resist blast loads. Field testing as well as finite element simulations are among the techniques available to engineers in the understanding of the structural behavior against blast loading. As blast testing of complex scenarios can be very resource intensive, tests are generally performed for simplified scenarios. Numerical tools can be used to model these scenarios in order to get a better insight into blast loading, structural response and the resulting damage to the structure. In the next steps, the simplified scenario is successively modified in numerical simulations to incorporate complexities that cannot be covered in blast testing experiments. One of the conditions for this approach to work is that the original simplified numerical simulation is valid. The scopes and challenges encountered in such a validation are the focus of this presentation. A relatively ‘simple’ field test of a horizontal reinforced concrete (RC) slab subjected to blast loading is taken as an example for validation of the performance of numerical tools. The blast test incorporated various measurement techniques to quantify the blast load as well as the behavior of the RC slab. Blast load was measured using flush-mounted piezoelectric pressure gauges, whereas acceleration sensors and fiber-optic sensor cables were used to characterize the dynamic behavior of the slab under blast loading. Additionally, damage characteristics were ascertained also using fiber-optic sensing. The application of such measurement techniques, along with different numerical software available for the analysis of the scenario in question,
demonstrate the scope of our contribution.
This paper presents an experimental study on the hydraulic failure of a submerged layer of cemented soil stressed by a localized upward water flow. Different mixtures of glass beads bonded with solid paraffin bridges were used as artificial material for the cemented granular soil. Variations in the cementation strength of the material were carefully introduced with different particle sizes and binder contents. The hydraulic fracture tests were then carried out with an upward flow injected at a controlled rate through a small section at the bottom of the samples. From a phenomenological perspective, the results reveal the existence of at least three modes of failure for a cemented soil layer: (1) overall block uplift, (2) block rupture by median crack at the inflow zone, and (3) progressive excavation of a fluidized path along the walls. The critical flow rate and pressure drop conditions at failure have been carefully quantified for the different mixtures and layer thicknesses, leading to a fair estimation of the hydraulic resistance of the samples, which here is found to be virtually independent of the grain size. However, the test results also showed inconsistent failure modes precluding so far the derivation of a simple phase diagram. Nevertheless, it was possible to rationalize all the measured data by employing appropriate modifications of the classical dimensionless numbers that describe the fluidization of purely frictional materials, whereby the cementation strength of the soil is quantified at the microscale through the yield tensile force of the intergranular bonds. Irrespective of its subsequent development, during which boundary conditions obviously play a major role, the initiation of the instability appears to take place very locally at the inlet when the drag force induced by the flow overcomes the cementation strength of the paraffin bonds. The results of this study thus appear to endorse the extension of the dimensional relationships of particulate systems in interaction with fluid flows to the case of cemented granular materials, in a similar vein as in recent previous studies.
Structural Health Monitoring (SHM) wird zunehmend zur kontinuierlichen Zustandsbewertung von Ingenieurbauwerken eingesetzt. Wichtige Bewertungsparameter sind globale Systemeigenschaften, wie z. B. Eigenfrequenzen, zu deren Bestimmung Beschleunigungssensoren eingesetzt werden. Häufig werden sog. MEMS-Sensoren (Micro Electro Mechanical Systems) verwendet, die jedoch ein hohes Rauschniveau aufweisen. Alternativ können rauschärmere IEPE-Sensoren (Integrated Electronics Piezo Electric) eingesetzt werden, die auch bei geringster Strukturanregung Schwingungen zuverlässig erfassen. Ferner besteht das Problem, dass Änderungen der Eigenfrequenzen infolge Bauwerksschädigung schwer von Änderungen der Eigenfrequenzen infolge Umwelteinflüssen zu unterscheiden sind. Letztere verändern die Eigenschaften der Struktur und die des Messsystems. Um Umwelteinflüsse auf das Messsystem im Anwendungsgebiet Ingenieurbau zu untersuchen, wurden IEPE-Beschleunigungsaufnehmer hinsichtlich ihres Übertragungsverhaltens im niederfrequenten Beschleunigungsbereich analysiert. Es zeigt sich, dass das Verhalten nicht nur frequenz-, sondern auch temperaturabhängig ist, während die Luftfeuchte keinen Einfluss hat. Diese für das Bauwerk unbedenklichen Einflüsse müssen für eine robuste Zustandsüberwachung kompensiert werden. Für die Anwendung im Ingenieurbau werden IEPE-Sensoren empfohlen, da sie ein hohes Signal-zu-Rausch-Verhältnis aufweisen und niederfrequente Bauwerksschwingungen zuverlässig erfassen.
Dieses Dokument beschreibt das Verfahren Schallemissionsanalyse zur Detektion von Spanndrahtbrüchen in Spannbetonbrücken im Rahmen einer kontinuierlichen Überwachung. Die Überwachung mit Schallemission liefert eine Aussage über die Anzahl von Spanndrahtbrüchen innerhalb des Überwachungszeitraumes und innerhalb der Reichweite der installierten Sensoren. Mit dem Verfahren können die Spanndrahtbrüche lokalisiert werden. Auf Basis einer weitgehend automatisierten Datenanalyse stehen Informationen über Drahtbrüche kurzfristig nach dem Ereignis zur Verfügung.
Der Anwendungsbereich des Dokuments umfasst Brücken- und Ingenieurbauwerke mit Spanndrähten mit sofortigem oder nachträglichem Verbund. Spannsysteme ohne Verbund fallen nicht in den Anwendungsbereich. Die beschriebenen Verfahren können auf Spannsysteme ohne Verbund übertragen werden. Mit dem Verfahren Schallemissionsanalyse ist es nicht möglich, Spanndrahtbrüche zu finden, die vor dem Beginn der Überwachung entstanden sind.
Das Dokument richtet sich an Baulastträger, Anbieter und Betreiber von Monitoringsystemen auf Basis der Schallemissionsanalyse sowie Ingenieurbüros, welche die Ergebnisse der Überwachung bewerten und Maßnahmen daraus ableiten. Es gibt Hinweise zur Planung, Ausschreibung, Installation und zum Betrieb von Monitoringsystemen zur Detektion von Spanndrahtbrüchen mit Schallemission sowie zur Überprüfung der Funktion installierter Systeme. Zur Funktionskontrolle werden Signale mit der Referenzquelle am Bauwerk ausgelöst. Diese Signale sind zu detektieren, innerhalb der vorgegebenen Genauigkeit zu
lokalisieren und die vorgegebene Alarmkette muss angestoßen werden.
The Bundesanstalt für Materialforschung und -prüfung (BAM) collaborates with TNO to develop a software framework for automated calibration of structural models based on monitoring data. The ultimate goal is to include such models in the asset management process of engineering structures. As a basis for developing the framework, a multi-span road bridge consisting of ten simply supported steel box girders was selected as a test case. Our group measured output-only vibration data from one box girder under ambient conditions. From the data, we determined eigenfrequencies and mode shapes. In parallel, we developed a preliminary structural model of the box girder for the purpose of predicting its modal properties. In this contribution, we provide an overview of the measurement campaign, the operational modal analysis, the structural modeling and qualitatively compare the identified with the predicted modes. As an outlook, we discuss the further steps in the calibration process and future applications of the calibrated model.
Managing aging engineering structures requires damage identification, capacity reassessment, and prediction of remaining service life. Data from structural health monitoring (SHM) systems can be utilized to detect and characterize potential damage. However, environmental and operational variations impair the identification of damages from SHM data. Motivated by this, we introduce a Bayesian probabilistic framework for building models and identifying damage in monitored structures subject to environmental variability. The novelty of our work lies (a) in explicitly considering the effect of environmental influences and potential structural damages in the modeling to enable more accurate damage identification and (b) in proposing a methodological workflow for model‐based structural health monitoring that leverages model class selection for model building and damage identification. The framework is applied to a progressively damaged reinforced concrete beam subject to temperature variations in a climate chamber. Based on deflections and inclinations measured during diagnostic load tests of the undamaged structure, the most appropriate modeling approach for describing the temperature‐dependent behavior of the undamaged beam is identified. In the damaged state, damage is characterized based on the identified model parameters. The location and extent of the identified damage are consistent with the cracks observed in the laboratory. A numerical study with synthetic data is used to validate the parameter identification. The known true parameters lie within the 90% highest density intervals of the posterior distributions of the model parameters, suggesting that this approach is reliable for parameter identification. Our results indicate that the proposed framework can answer the question of damage identification under environmental variations. These findings show a way forward in integrating SHM data into the management of infrastructures.
Nowadays geotechnical engineering firms have powerful software tools to extent their consult-ing business also into dynamic soil-structure interaction, which before has been restricted to a rather small community of specialized experts in this field, and they certainly do. This is par-ticularly true with respect to non-seismic sources, that is all kinds of human induced vibrations. Hence, there is a demand from clients as well as from contractors to have guidance on the re-quirements as well as the limits of numerical modelling of soil-structure interaction. From the literature as well as from relevant standards, recommendations for the numerical modelling of soil-structure interaction problems involving seismic actions are well known, e. g. ASCE/SEI 4-16. There are, however, some particularities when dealing with human-induced vibrations, which are absent in seismic analyses. For human-induced excitations very little specific guid-ance has been published in the past. A machine foundation on a homogeneous half space ex-cited by harmonic loads with excitation frequency between 4 Hz and 64 Hz has been ana-lysed by means of several commercially available software packages. Parametric studies have been performed to verify if recommendations for seismic soil-structure analyses are valid for non-seismic analyses as well. This paper provides details on the benchmark example and the most important conclusions from the undertaken parametric studies.
ISO 14837-32:2015 and DIN EN 1998-1/NA:2021 as well as prEN 1997-2:2022 allow for us-ing correlations between the results of in-situ soil penetration tests and shear wave velocity (or shear modulus) to determine soil properties to be used in dynamic analyses. While the ISO and prEN standards even provide some recommendations on specific correlations to be used, the DIN standard does not. Due to the statistical nature of such correlations their general applica-bility has to be verified. We collected data sets from test sites from Germany as well as New Zealand at which cone penetration tests (CPT) as well as seismic site investigation methods were conducted. These sites comprise sandy soils as well as clayey soils, mixed soils as well as glacial soils. We compare the results of several correlations between CPT results and shear wave velocity. The accuracy of such correlations is assessed with respect to the accuracy of seismic in-situ tests. It turns out that for clean sands such correlations between CPT and Vs have a similar order of variability as seismic in-situ tests conducted at the same site. The higher the fines portion of the soil, the higher the variability of the statistical correlations, and conse-quently the less the general applicability. For glacial soils and other special soil types usage of statistical correlations to determine dynamic soil properties is not recommended.
Protection against terroristic or accidental scenarios in industrial settings requires suitable designs of structures to resist blast loads. Field testing as well as finite element simulations are among the techniques available to engineers in the understanding of the structural behavior against blast loading.
As blast testing of complex scenarios can be very resource intensive, tests are generally performed for simplified scenarios. Numerical tools can be used to model these scenarios to get better insight into blast loading, structural response, and the resulting damage to the structure. During the next steps, the simplified scenario is successively modified in numerical simulations to incorporate complexities that cannot be covered in blast testing experiments. One of the conditions for this approach to work is that the original simplified numerical simulation is valid. The scopes and challenges encountered in such a validation are the focus of this presentation/article.
A relatively ‘simple’ field test of a horizontal reinforced concrete (RC) slab subjected to blast loading is taken as an example for validation of the performance of numerical tools. The blast test incorporated various measurement techniques to quantify the blast load as well as the behavior of the RC slab. Blast load was measured using flush mounted piezoelectric pressure gauges, whereas acceleration sensors and fiber-optic sensor cables were used to characterize the dynamic behavior of the slab under blast loading. Additionally, damage characteristics were ascertained also using fiber optic sensing. The application of such measurement techniques, along with different numerical software available for the analysis of the scenario in question, demonstrate the scope of our contribution.
When it comes to the challenges, it begins with proper instrumentation of the test specimen followed by the data processing. For numerical modelling, geometric conditions with appropriate boundary constraints, physical conditions such as the configuration of the rebars, as well as material parameters add to this challenge. The issues of choosing appropriate material models and comparison of results with multiple software tools will be discussed. This discussion forms the basis for a coherent approach to technical-safety assessment of blast effects on structures in its broader sense.
Current capabilities for full-scale field testing are highly resource intensive. Reliable small-scale experiments are an effective alternative. Characterization of the dynamic response and damage of RC elements to scaled blast loads was investigated in scaled-down field experiments. Spatially resolved information on the dynamic structural response using distributed fiber optic acoustic sensing (DAS) and acceleration as well as blast loading by piezoelectric pressure sensors.