Infrastruktur
Filtern
Erscheinungsjahr
- 2022 (305) (entfernen)
Dokumenttyp
- Vortrag (138)
- Zeitschriftenartikel (77)
- Beitrag zu einem Tagungsband (51)
- Posterpräsentation (15)
- Sonstiges (7)
- Buchkapitel (6)
- Forschungsbericht (5)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
Schlagworte
- Korrosion (20)
- Corrosion (19)
- Concrete (18)
- Ultrasound (13)
- Potentialfeldmessung (10)
- Structural health monitoring (10)
- Brandschutz (8)
- Brückenbeläge (8)
- Spannungsrisskorrosion (8)
- Distributed acoustic sensing (7)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (180)
- 8 Zerstörungsfreie Prüfung (84)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (54)
- 7.6 Korrosion und Korrosionsschutz (45)
- 7.2 Ingenieurbau (39)
- 2 Prozess- und Anlagensicherheit (36)
- 2.1 Sicherheit von Energieträgern (25)
- 3 Gefahrgutumschließungen; Energiespeicher (24)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (24)
- 7.1 Baustoffe (23)
Paper des Monats
- ja (7)
Eingeladener Vortrag
- nein (138)
Performance of the standardized testing method for detonation fl ame arresters at increased pressure
(2022)
Detonation flame arresters are typically used as autonomous protection systems in industrial applications to prevent potential hazards associated with flammable and/ or explosive chemicals. To verify and examine the suitability of detonation flame arresters, a testing method originating from the DIN EN ISO 16852 standard is used, which is mainly designed for atmospheric conditions.
In order to optimize the production capabilities, numerous industrial processes are taking place at pressures, temperatures, or oxygen concentrations beyond the ambient range, i.e. at non-atmospheric conditions and information on the performance of the regulated testing method are therefore required when the standard testing protocols are modified with regard to pressure, temperature or oxidizer.
The main objective of this study is to develop an improved testing method for detonation flame arresters, which offers a higher reproducibility and moreover, an applicability under non-atmospheric conditions. Therefore, an interlaboratory comparison on the performance of in-line flame arresters for stable and unstable detonations is jointly conducted by the project partners (PTB, BAM, Braunschweiger Flammenfilter GmbH and IBExU GmbH). The experiments are performed according to the testing method regulated in the DIN EN ISO 16852 standard for different pressures before ignition and different explosion groups. The experimental data is analyzed in detail to further optimize the test method and to thus achieve an improved reproducibility of detonation tests at high pressures, especially regarding the deflagration to detonation transition.
Potential ambiguities of the standardized testing method that might lead to the differing results at the different institutes are identified from the interlaboratory comparison and the test method is modified accordingly. Based on these results, an improved testing method for detonation flame arresters will be developed, which will ensure a greater safety at process plants while handling combustibles.
Wasserstoff wird als ein potenzieller alternativer Energieträger gesehen, mit dem die für 2050 gesetzten Klimaziele erreicht werden könnten. Der Transport von Wasserstoff ist mittels verschiedener Speichertechniken möglich, von denen der kryogene Transport mit den größten volumetrischen Energiedichten einhergeht. Hierdurch eignen sich diese Speicher besonders für die energieintensiven Verkehrsmittel im Land-, See- und Flugverkehr.
Im Vortrag werden Speichertechniken, Gefahren im Umgang mit kryogenen Gasen sowie bisherige Störfälle dargestellt. Darauf aufbauend wird ein Teil der aktuellen Forschungsarbeit an der BAM vorgestellt, die die Sicherheit dieser Speicher unter außergewöhnlichen Belastungen adressiert.
Intumescent coatings are commonly used in civil engineering to improve the fire resistance of steel constructions. Especially in the case of tension bars, where mostly circular or rectangular solid sections are used, intumescent coatings offer an efficient measure to improve the fire resistance taking advantage of profile-following application and low coating thickness requirements. Thus, the architectural appearance of slender profiles can be preserved. The paper describes real-scale mechanically loaded and unloaded fire tests of circular and rectangular solid steel tension bars with intumescent coating. The aim of these tests is to investigate the influence of the different profile types as well as different bar orientations on the performance of intumescent coatings. The results are used to specify a normative test and assessment procedure to be implemented in a new European standard for determining the contribution of intumescent coatings to the fire resistance of circular or rectangular bars used as tension members.
To improve ultrasonic imaging of concrete structures, we transferred a seismic migration technique, the Reverse Time Migration (RTM), to non-destructive testing. A 2D elastic RTM algorithm was tested on synthetic ultrasonic echo data. Compared to the typically used synthetic aperture focusing technique (SAFT) as well as our acoustic RTM algorithm, the presented elastic RTM results show an enhancement in imaging vertical reflectors and complex features inside the 2D numerical concrete model.
The ultrasonic echo technique is widely used in non-destructive testing for investigation and damage analysis of concrete constructions. Important applications include thickness measurements, geometry determination, the localization and characterization of built-in components as well as the detection of quality issues (cracks, honeycombing, low concrete strength).
To improve ultrasonic data imaging of complicated structures in concrete, we transferred a seismic migration technique, the Reverse Time Migration (RTM), to non-destructive testing in civil engineering. In a preliminary study, we tested a 2D acoustic RTM algorithm on measured ultrasonic echo data acquired at a concrete foundation slab. Compared to the conventional used synthetic aperture focusing technique algorithms (SAFT) for ultrasonic data reconstruction, our acoustic RTM results showed a significant improvement in imaging the interior structure of the concrete slab. Vertical reflectors were reconstructed which was not possible by traditional imaging.
In contrast to SAFT, RTM is a wavefield-continuation method in time and uses the full wave equation. RTM is, thus, able to include multiple reflections and to handle multi-pathing as well as many other complex situations. As a drawback RTM requires extensive computing power and memory capacity. Nevertheless, due to progresses in parallel processing and other computational technologies RTM has become appealing for the application in the field of non-destructive testing.
An RTM algorithm, which uses the full elastic wave equation instead of the full acoustic one (as applied in our preliminary work) has the potential to optimize the imaging results even further. This is due to the fact, that our ultrasonic measurement data are generated by exciting elastic waves. Thus, in a first step, two 2D elastic RTM algorithms were tested on synthetic ultrasonic echo data generated with a concrete model consisting of several steps and circular shaped air inclusions. In addition, two imaging conditions were evaluated to reduce migration artifacts. Our synthetic elastic RTM results showed an enhancement in imaging the features inside the test model compared to acoustic RTM and SAFT. In a second step, we acquired ultrasonic measurement data at a concrete test specimen consisting of three steps and four air filled tendon ducts. The evaluation of the real data with our elastic RTM code was also successful and the reconstruction of the geometries of the steps and tendon ducts could be improved. With our study we have shown that elastic RTM is a step forward for ultrasonic testing in civil engineering.
Das Ultraschall-Echo-Verfahren ist eine klassische zerstörungsfreie Prüftechnik zur Geometriebestimmung sowie Schadensanalyse von Betonkonstruktionen. Um die Abbildung der Ultraschalldaten von komplexen Betonstrukturen zu verbessern, haben wir die Reverse-Time Migration (RTM) aus der Seismik auf die zerstörungsfreie Prüfung im Bauwesen übertragen. In einer Vorstudie haben wir einen 2D akustischen RTM Code verwendet und an realen Ultraschalldaten, die an einer Betonfundamentplatte aufgenommen wurden, getestet. Im Vergleich mit dem herkömmlichen Rekonstruktionsalgorithmus für Ultraschalldaten, der Synthetic Aperture Focusing Technique (SAFT), zeigten die akustischen RTM-Ergebnisse eine deutliche Verbesserung in der Abbildung der inneren Struktur der Betonfundamentplatte. Vertikale Reflektoren konnten rekonstruiert werden, was mit dem herkömmlichen Abbildungsverfahren nicht möglich war. RTM ist, im Gegensatz zu SAFT, eine wellengleichungsbasierte Migrationsmethode und beruht auf der numerischen Lösung der vollständigen Wellengleichung. Die Vorteile sind, dass der Algorithmus sämtliche Informationen des Wellenfeldes verwendet und daher verschiedene Welleneffekte wie z.B. Multipathing berücksichtigt werden können. Die RTM bietet damit die Möglichkeit auch stark geneigte Reflektoren sowie Streukörper mit komplexen Geometrien darzustellen. Ein Nachteil ist jedoch die lange Rechenzeit und der hohe Bedarf an Speicherkapazität. Ein RTM-Algorithmus, der die elastische Wellengleichung anstatt der akustischen verwendet (wie in unserer Vorstudie angewandt), hat das Potenzial, die Abbildungsergebnisse noch weiter zu optimieren. Das liegt daran, dass unsere Ultraschallmessdaten durch Anregung elastischer Wellen generiert werden. In einem ersten Schritt haben wir zwei elastische 2D-RTM-Algorithmen an synthetischen Ultraschalldaten getestet. Diese wurden mit einem Betonmodell, bestehend aus mehreren Stufen und kreisförmigen Lufteinschlüssen, erzeugt. In einem zweiten Schritt wurden reale Ultraschalldaten mit Scherwellenprüfköpfen an einer Betonstufenplatte mit integrierten Hüllrohren aufgenommen. Die Auswertung der realen Daten mit unserem elastischen RTM-Code war ebenfalls erfolgreich. Wir konnten die Abbildungsqualität der Stufen und Hüllrohre im Vergleich zur akustischen RTM und SAFT verbessern.
A conclusion on the WIPANO research project "Safety of Prestressing Steel" was presented in the final committee meeting at the end of the project. The project's exciting findings and recommendations for a new method were discussed with the audience of national and international stakeholders of the prestressing steel industry and representatives of inspection bodies and standardization.
Corrosive geothermal brines are a major challenge to geothermal power-plants. For cost reasons, plant designers favorize low alloyed steels, e.g., carbon steel, which are susceptible to uniform and localized corrosion when exposed to geothermal brines having acidic and saline properties. To solve such problem, coatings or inhibitors would be a protective solution as an alternative to the use of high alloyed materials.
This study investigated a coating system consisting of polyaniline/silicon dioxide basing on locally available resources. Protection against corrosion of carbon steel is shown by long-term exposure and electrochemical tests of coated carbon steels, performed in an artificial acidic and saline geothermal brine, comparable to real conditions at a site in Indonesia.
Therefore, an integrated coating system is presented for corrosion protection, combining the electro-chemical functionality of polyaniline and the physical advantages of silica.
The screening of coatings shows that the modification by adding individual pigment was not sufficient to protect carbon steel even during a short-term exposure, indicated by the discoloration after only seven days of exposure.
Electrochemical tests indicated that the coating cathodically protects carbon steel or slows down the corrosion reaction.
A long-term exposure test confirmed that the PANI/SiO2 modified coating successfully protects the carbon steel in the Sibayak artificial geothermal water at 150 °C for 6 months.
The fire-induced spalling behaviour of concretes has a huge effect on the fire resistance of concrete components. Therefore, fire performance must be taken into account in the design and dimensioning of concrete structures. The use of new types of concrete and different types of cement or binder must also be considered. Despite decades of research, the mechanisms underlying the spalling phenomenon are not yet fully understood. However, knowledge about these mechanisms is the prerequisite for predicting the spalling behaviour as accurately as possible.
Experimental research from material characterisation on the micro scale up to full-sized fire tests as well as the simulation and modelling of fire-induced damage processes offer the opportunity to investigate the spalling behaviour of concrete. Thereby, a variety of influencing parameters must be regarded. Against this background, the effect of avoidance strategies can be evaluated.
Since 2009, the International Workshop on Concrete Spalling due to Fire Exposure (IWCS) offers a platform to get in touch with researchers and practitioners, exchange the latest research results and newly acquired data from real fire scenarios, and discuss current developments in the field of concrete spalling. After the successful workshops in Leipzig (Germany), Delft (Netherlands), Paris (France), Borås (Sweden) and Sheffield (United Kingdom), the 7th International Workshop IWCS took place in Berlin at BAM. It provided insights into the work of two RILEM Technical Committees. Based on this, various results of screening tests and large-scale tests for the assessment of the fire-induced spalling behaviour of concretes were presented, taking into account a large number of influencing parameters. Further topics of the workshop were the analysis of the mechanisms for the spalling phenomenon as well as the modelling and simulation of the spalling processes. A large part of the workshop was devoted to the high-temperature behaviour of various types of concrete.
The workshop was dedicated to Prof. Diederichs, who passed away on 20 January 2022. With his death, the spalling community lost an internationally renowned expert in the field of fire behaviour of concrete and reinforced concrete components. He played a decisive role in the design of all previous RILEM TCs on the high temperature and fire behaviour of concretes and reinforced concrete components.
In this paper, a cost-efficient distributed fiber optic measurement system based on Rayleigh scattering is presented. The distributed digital incoherent optical frequency domain reflectometry (I-OFDR) method is developed for detection of significantly large strain in the range from 3 % up to 10 % as required by end users. For this purpose, a vector network analyzer used in the I-OFDR is replaced by a compact and cost-effective digital data acquisition system. This digital emitting/receiving unit enables the recording of the complex transfer function carrying information about the local deformations along the entire sensing fiber.
The evaluation of thermal properties is probably an underrated tool for the onsite health monitoring of concrete structures. The photothermal approach offers a possibility to realize a real onsite measurement. This contribution presents the application of the photothermal approach under lab conditions on three different concrete types. The obtained results were compared with those of a commercial device based on the Transient Plane Source (TPS) method. Both agreed well within the estimated uncertainty ranges and therefore demonstrate the applicability of the photothermal method for this kind of investigations. First results of a concrete sample with different water contents support the potential of this method for the characterization of concrete in general.
Diese Präsentation stellt die Ergebnisse des abgeschlossenen WIPANO Vorhabens "Spannstahlsicherheit" vor, welches von der BAM in Kooperation mit dem Stahlwerks Annahütte und der Max Aicher GmbH bearbeitet wird. Es werden die Projektziele näher beleuchtet und verschiedentliche Highlights der erzielten Untersuchungsergebnisse vorgestellt.
Galvanic corrosion protection by embedded zinc anodes is an accepted technique for the corrosion protection of reinforcing steel in concrete. Galvanic currents flow between the zinc anode and the steel reinforcement due to the potential difference that is in the range of a few hundred mV.
The ion distribution was studied on two steel reinforced concrete specimens admixed with 3 wt.% chloride/wt. cement and galvanically protected by a surface applied EZ-anode. On both specimens, a zinc anode was embedded and glued to the concrete surface by a geo-polymer-based chloride-free binder. At one specimen, the EZ-anode was operated for 2,5 years, the EZ-anode at the other specimen was not electrically connected to the reinforcement, this specimen serves as a reference. Both specimens have been stored under identical conditions. The ion distribution between the anode (EZ-ANODE) and cathode (steel reinforcement) was studied by laser-induced breakdown spectroscopy (LIBS) after 7 months, 12 months, and 2,5 years. Results of the LIBS studies on the specimen with activated EZ-anode after 7 months, 12 months, and 2,5 years and of the reference specimen after 2,5 years are reported. Results show that diffusion of ions contributes to the changes in the ion distribution but migration, especially of chlorides towards the EZ-anode is significant despite the weak electric field – several hundred millivolts - generated by the galvanic current. Results show that chloride ions accumulate near the zinc-anode as in water-insoluble zinc-hydroxy chlorides - Simonkollite.
Investigating the spalling behaviour of a concrete mixture using large scale members is complex and expensive. Thus, the susceptibility of concrete to spalling is investigated by means of fire tests on small scale specimens. However, the reduction of the fire exposed surface increases the influence of boundary effects. Macrocracking and the water loss via the lateral surfaces reduce the impact of the thermomechanical and thermohydraulic damage mechanisms and therefore, lower the risk of spalling. Thus, the influence of different restraints on the spalling behaviour of intermediate scaled specimens (Ø=0.47 m; h=0.29 m) was investigated for two ordinary concrete mixtures. Both mixtures had the same composition except the type of aggregate. One mixture contained only quartzitic aggregates, whereas the other mixture was made with basalt grit as coarse aggregates. Applied steel rings restrained the thermal expansion of the specimen and prevented the loss of water, whereas applied steel sheet primarily reduced the loss of water during the fire test. Additionally, the fire exposed surface of one specimen of each mixture was pre-dried under controlled climate conditions and fire tested with applied steel rings. The results show a higher spalling volume for the ring restrained specimens compared to the other covering types. Further, the pre-dried boundary zone leads to delayed and decreased occurrence of spalling compared to the non-dried specimens for the concrete with quartzitic aggregates and to a prevention of spalling for the mixture with basalt aggregates. Additionally, the results show that the influence of the thermomechanical behaviour of the coarse aggregates increases with increasing restraint. The restrained conditions of the specimens with applied steel ring are comparable to the conditions in the centre of a large scale member. This test series is a further step for possible concept of steel ring restraint concrete specimens as “screening-tests” in upcoming projects.
A methodology is proposed for the experimental analysis of the liquid cargo effect under combined orthogonal accelerations. To simultaneously subject the vehicle-cargo system to longitudinal and lateral accelerations, the vehicle is set obliquely on a tilt table. The experimental outputs suggest that there is a significant effect of the liquid cargo on the lateral load transfer ratio (LTR), on the order of 20%, which is attributable to the resulting shifting of the liquid cargo’s centre of gravity. That is, the peak LTR values due exclusively to sloshing were not significant, in such a way that the liquid cargo would only pose a safety risk under a steady acceleration input.
Also, the inverse of the product of the magnitude of the acceleration times the free surface length, correlates with the liquid cargo effect. That is, the magnitude of the input acceleration is not fully determinant for greater load transfers.
Existing concrete structures were usually designed for lifetimes of several decades. The current and urgently required efforts to increase sustainability and protect the environment will likely result in extended service lives up to 100 years. To achieve such objectives, it is required to assess structures over their entire lifecycles. Non-destructive testing (NDT) methods can reliably support the assessment of existing structures during the construction, operational, and decommissioning phases. One of the most important and safety-relevant components of a prestressed concrete structure are the tendons. NDT methods such as the ultrasonic echo method are suitable for both the detection and the localization of the tendons, i.e., the measurement of their geometrical position inside the component. The uniqueness of structures, concrete heterogeneity, and varying amounts of secondary components such as the reinforcement represent obstacles in the application of these methods in practice. The aim of this contribution is to demonstrate a practicable procedure, that can be used in the field to determine the parameters required for the measuring data analysis without extensive knowledge about the investigated components. For this purpose, a polyamide reference specimen is used to show which steps are required to obtain reliable imaging information on the position of tendons from the measurement data. The procedure is then demonstrated on a concrete test specimen that covers various relevant and practice-oriented test scenarios, such as varying tendon depths and component thicknesses.
The current understanding of the carbonation and the prediction of the carbonation rate of alkali-activated concretes is complicated inter alia by the wide range of binder chemistries used and testing conditions adopted. To overcome some of the limitations of individual studies and to identify general correlations between mix design parameters and carbonation resistance, the RILEM TC 281-CCC ‘Carbonation of Concrete with Supplementary Cementitious Materials’ Working Group 6 compiled and analysed carbonation data for alkali-activated concretes and mortars from the literature. For comparison purposes, data for blended Portland cement-based concretes with a high percentage of SCMs (≥ 66% of the binder) were also included in the database. The analysis indicates that water/CaO ratio and water/binder ratio exert an influence on the carbonation resistance of alkali-activated concretes; however, these parameters are not good indicators of the carbonation resistance when considered individually. A better indicator of the carbonation resistance of alkali-activated concretes under conditions approximating natural carbonation appears to be their water/(CaO + MgOeq + Na2Oeq + K2Oeq) ratio, where the subscript ‘eq’ indicates an equivalent amount based on molar masses. Nevertheless, this ratio can serve as approximate indicator at best, as other parameters also affect the carbonation resistance of alkali-activated concretes. In addition, the analysis of the database points to peculiarities of accelerated tests using elevated CO2 concentrations for low-Ca alkali-activated concretes, indicating that even at the relatively modest concentration of 1% CO2, accelerated testing may lead to inaccurate predictions of the carbonation resistance under natural exposure conditions.
Each engineering decision is based on a number of more or less accurate information. In assessment of existing structures, additional relevant information collected with on-site inspections facilitate better decisions. However, observed data basically represents the physical characteristic of interest with an uncertainty. This uncertainty is a measure of the inspection quality and can be quantified by expressing the measurement uncertainty. The internationally accepted rules for calculating measurement uncertainty are well established and can be applied straightforwardly in many practical cases. Nevertheless, the calculations require the occasionally time-consuming development of an individually suitable measurement model. This contribution attempts to emphasize proposals for modelling the non-destructive depth measurement of tendons in concrete using the ultrasonic echo technique. The proposed model can serve as guideline for the determination of the quality of the measured information in future comparable inspection scenarios.
A simple and fast prediction scheme is presented for train-induced ground and building vibrations. For the emission, finite-element boundary-element or multiple-beam-on-continuous-soil models of the track have been analysed and approximated by faster track-on-Winkler-soil models. The vehicle-track interaction due to irregularities yields the excitation forces. For the transmission of waves in the soil, the wavenumber integral of the compliance of layered soils has been evaluated. The calculation time is reduced for the prediction by using the solution of a homogeneous half-space with a frequency-dependent wave velocity (the dispersion) of the soil. For the immision, many 2 and 3-dimenisonal finite-element building models have been investigated, and a good approximation has been established by a 1-dimensional soil-wall-floor model. In addition, the axle sequence of the train, the quasi-static and the “scattered” response of the soil, and the wave propagation from a tunnel to a pile foundation of a building have been included.
Usually, geometric irregularities are considered as the main cause of ground vibrations from trains. A varying stiffness of the track, the track support and the soil can also generate ground vibrations. The regular stiffness variation of the track on and between the sleepers results in a deterministic dynamic axle load. The random stiffness variation of the track support yields also dynamic axle loads. The dynamic axle loads are generated by the varying wheel displacements under the static axle load by the acceleration of the unsprung mass of the rail vehicle. The random stiffness variation has a second effect. The pulses from the passage of the static axle loads are superposed regularly to the quasi-static response, but also irregularly to yield a “scattered” part of the axle pulses. The same holds for a random variation of the soil stiffness. All these effects of stiffness variations have been calculated by wavenumber-domain multi-beam track models, a random finite-element soil model and the superposition of axle impulses in a stochastic simulation. The results are confronted with many measurements at different sites. It is concluded that the stiffness variation of the track and the soil generate an important ground vibration component near railway lines.
Vibration measurements have many causes and many technical and natural sources. Problems can sometimes be solved by short-term measurements, but in many cases, a long-term measurement is necessary. In long-term measurements of days, weeks, months and even years, it is easy to collect a huge quantity of raw data, but at the end, the post-processing of these data can be exhausting (for example one-year vibration data of a wind energy tower). A software has been developed which con-sists of measuring and evaluation routines where the measuring routines can operate different meas-uring systems and different measuring cards. The main advantage of this software is the fact that the interesting evaluations can be integrated in the measuring process so that the characteristics of the vibration can be extracted without storing all the raw data. Only important time segments are stored, for example train passages. The overall concept of the software and the main evaluation routines will be described in some details. Examples of our measurement experience will illustrate the capabilities of the software. 1) Surveying construction work in nearby sensitive buildings (for example an old wind tunnel), including a stable alarm system and meaningful vibration limits. 2) Prediction of train-induced vibration for a planned building to prevent annoyance and to improve the building design. 3) Modal analysis and long term measurements of several single- or multi-span, concrete or steel bridges 4) Modal and wave analysis of coupled floors in a historical building (“Neues Palais” at Potsdam). 5) Soil properties of various measurement sites (different routines to evaluate the dispersion). Moreover, from many projects, amplitudes, frequencies, and attenuation laws have been collected and analysed for the different sources such as vibratory or impact pile driving and ground compaction, demolition work with different machines, blasting in quarries and in tunnel works, bomb and mine clearing.
Monitoring of construction projects plays increasingly important role in the implementation of growing needs and requirements, especially in geologically difficult areas. This particularly concerns tunnelling and special civil engineering projects. The use of fiber optic sensors for structural health monitoring provides significant economic advantages regarding lower life-cycle costs of the civil infrastructure. We present our achievements in the development of distributed polymer optical fiber sensors based on Rayleigh and Brillouin scattering for early damage detection.
Investigating the spalling behaviour of a concrete mixture using large scale members is complex and expensive. Thus, the susceptibility of concrete to spalling is investigated by means of fire tests on small scale specimens. However, the reduction of the fire exposed surface increases the influence of boundary effects. Macrocracking and the water loss via the lateral surfaces reduce the impact of the thermomechanical and thermohydraulic damage mechanisms and therefore, lower the risk of spalling. Thus, the influence of different restraints on the spalling behaviour of intermediate scaled specimens (Ø0.47 m; h=0.29 m) was investigated for two ordinary concrete mixtures. Both mixtures had the same
composition except the type of aggregate. One mixture contained only quartzitic aggregates, whereas the other mixture was made with basalt grit as coarse aggregates. Applied steel rings restrained the thermal expansion of the specimen and prevented the loss of water, whereas applied steel sheet primarily reduced the loss of water during the fire test. Additionally, the fire exposed surface of one specimen of each mixture was pre-dried under controlled climate conditions and fire tested with applied steel rings. The results show a higher spalling volume for the ring restrained specimens compared to the other covering types. Further, the pre-dried boundary zone leads to delayed and decreased occurrence of spalling compared to the non-dried specimens for the concrete with quartzitic aggregates and to a prevention of spalling for the mixture with basalt aggregates. Additionally, the results show that the influence of the thermomechanical behaviour of the coarse aggregates increases with increasing restraint. The restrained conditions of the specimens with applied steel ring are comparable to the conditions in the centre of a large scale member. This test series is a further step for possible concept of steel ring restraint concrete specimens as “screening-tests” in upcoming projects.
In addition to already established structural monitoring methods such as deformation, inclination or strain gauges or acoustic emission sensors, sonic or ultrasonic monitoring might provide valuable information about the condition or alteration of a structure. Sensors such as geophones, recording ambient noise in the sonic and subsonic frequency range can provide information beyond modal analysis by using interferometric methods. Wave velocities determined by this method are related to the elastic properties and stiffness of material and structure and can be converted into damage indicators. Embedded active ultrasonic transducer networks can provide more detailed insight about deterioration or damages again, using interferometric technologies. This approach is extremely sensible, detecting relative change in velocity on down to 10-5. These methods, including benefits and remaining challenges, are demonstrated using data from a test structure at BAM’s test site demonstrating the case of prestress loss, and data from an actual bridge still under traffic.
Existing concrete structures were usually designed for lifetimes of several decades. The current and urgently required efforts to increase sustainability and protect the environment will likely result in extended service lives up to 100 years. To achieve such objectives, it is required to assess structures over their entire lifecycles. Non-destructive testing (NDT) methods can reliably support the assessment of existing structures during the construction, operational, and decommissioning phases. One of the most important and safety-relevant components of a prestressed concrete structure are the tendons. NDT methods such as the ultrasonic echo method are suitable for both the detection and the localization of the tendons, i.e., the measurement of their geometrical position inside the component. The uniqueness of structures, concrete heterogeneity, and varying amounts of secondary components such as the reinforcement represent obstacles in the application of these methods in practice. The aim of this contribution is to demonstrate a practicable procedure, that can be used in the field to determine the parameters required for the measuring data analysis without extensive knowledge about the investigated components. For this purpose, a polyamide reference specimen is used to show which steps are required to obtain reliable imaging information on the position of tendons from the measurement data. The procedure is then demonstrated on a concrete test specimen that covers various relevant and practice-oriented test scenarios, such as varying tendon depths and component thicknesses.
Approaches to the development of a (GUM-) measurement model for the calculation of measurement uncertainties in the localization of tendons in concrete structures using the ultrasonic echo method including demonstration were presented.
Überblick über den State-of-the-Art und aktuelle Trends mit den Schwerpunkten:
- nachwachsende Rohstoffe in flammgeschützten Polymerwerkstoffen (flammgeschützte Biopolymere und Biokomposite; biomass-basierte Flammschutzmittel, nachwachsende Hilfsstoffe aus Abfallströmen)
- Nachhaltigkeit und Flammschutz
- Konzepte von Analogie bis Out-of-the-Box.
Galvanic corrosion protection by embedded zinc anodes is an accepted technique for the corrosion protection of reinforcing steel in concrete. Galvanic currents flow between the zinc anode and the steel reinforcement due to the potential difference that is in the range of a few hundred mV. The ion distribution was studied on two steel reinforced concrete specimens admixed with 3 wt.% chloride/wt. cement and galvanically protected by a surface applied EZ-anode. On both specimens, a zinc anode was embedded and glued to the concrete surface by a geo-polymer-based chloride-free binder. At one specimen, the EZ-anode was operated for 2,5 years, the EZ-anode at the other specimen was not electrically connected to the reinforcement, this specimen serves as a reference. Both specimens have been stored under identical conditions. The ion distribution between the anode (EZ-anode) and cathode (steel reinforcement) was studied by laser-induced breakdown spectroscopy (LIBS) after 7 months, 12 months, and 2,5 years. Results of the LIBS studies on the specimen with activated EZ-anode after 7 months, 12 months, and 2,5 years and of the reference specimen after 2,5 years are reported. Results show that diffusion of ions contributes to the changes in the ion distribution but migration, especially of chlorides towards the EZ-anode is significant despite the weak electric field – several hundred millivolts - generated by the galvanic current. Results show that chloride ions accumulate near the zinc-anode as in water-insoluble zinc-hydroxy chlorides - Simonkolleit.
Mechanochemical reactions are driven by the direct absorption of mechanical energy by a solid (often crystalline) material. Understanding how this energy is absorbed and ultimately causes a chemical transformation is essential for understanding the elementary stages of mechanochemical transformations. Using as a model system the energetic material LiN3 we here consider how vibrational energy flows through the crystal structure. By considering the compression response of the crystalline material we identify the partitioning of energy into an initial vibrational excitation. Subsequent energy flow is based on concepts of phonon–phonon scattering, which we calculate within a quasi-equilibrium model facilitated by phonon scattering data obtained from Density Functional Theory (DFT). Using this model we demonstrate how the moments (picoseconds) immediately following mechanical impact lead to significant thermal excitation of crystalline LiN3, sufficient to drive marked changes in its electronic structure and hence chemical reactivity. This work paves the way towards an ab initio approach to studying elementary processes in mechanochemical reactions involving crystalline solids.
The size effect has its origin in fracture mechanics and describes the formation as well as propagation of cracks in brittle and solid materials in dependence of the specimen size. However, the size effect in concrete spalling describes the damage behaviour on a macroscopic scale for different sized specimens in case of fire. Concrete spalling is a very complex and yet not fully understood phenomenon. To reduce the effort of fire tests to analyse the spalling behaviour of concrete mixtures, this study investigates the susceptibility to spalling for six different concrete mixtures and three specimen sizes. The sizes were divided in full scale slabs (1.8 m x 1.2 m x 0.3 m), intermediate scale cuboids (0.6 m x 0.6 m x 0.3 m) and small scale cylinders (Ø0.15 m x 0.3 m). For this purpose, a novel test set-up was built to test six intermediate scale or twelve small scale specimens simultaneously to ensure a similar heating regime for every specimen. All specimens were fire exposed on one side and remained unrestrained. A size effect occurred for four of the six concrete mixtures. Compared to the full scale specimens the spalling was reduced significantly for all smaller specimen sizes. Additionally, spalling did not occur for the small scale specimens. The results show that the specimen size is an essential parameter to investigate the susceptibility to spalling of a concrete mixture. For future investigations the testing conditions must be adjusted for the intermediate scale specimens to recreate the conditions of the slabs.
The poor thermal conductivity of MH beds limits hydrogen absorption in metal hydride (MH) reactors for thermochemical heat storage. The compaction of MH powder with expanded natural graphite (ENG) is an efficient and cost-effective approach for the heat transfer enhancement of MH beds. However, the addition of ENG reduces the hydrogen storage density of the compacted composites. How to optimize the allocation of a limited amount of ENG in the MH bed has not been studied. In this study, a multilayer MH bed configuration with an ENG grade content was adopted to improve the heat transfer performance of an MH reactor for thermochemical heat storage. The effect of the ENG content gradient on the performance of the MH reactor was investigated using a mathematical model of the MH reactor. Furthermore, an optimization method based on the entransy dissipation extremum principle (EDEP) was proposed to optimize the ENG distribution in magnesium hydride (MgH2)-ENG compacts. The results showed that a larger ENG content gradient resulted in faster hydrogen absorption and better heat-discharge performance. Compared with a configuration with a uniform ENG content, the optimized configuration based on the EDEP exhibited a shorter reaction time, more uniform bed temperature distribution, and 15.33% higher gravimetric exergy-output rate. In addition, the number of optimization iterations had little effect on the optimal results, which could be obtained by implementing only one optimization iteration. The optimization results showed that more ENG should be allocated to the internal layer of the MgH2-ENG compact. The compacts were divided into three layers, and the ENG content of each layer was calculated according to the optimized configuration based on the EDEP. The optimization method proposed in this study can be applied to optimize
MIKE III apparatus tests were conducted to investigate the minimum ignition energy (MIE) of coal dusts in air and O2/CO2 atmospheres with and without small amount of CH4/H2. The O2 mole fraction (XO2) in the gas mixtures varied from 21% to 50% with the CH4/H2 mole fraction from 0 to 2%. Experimental result showed that MIE of coal dusts significantly decreases even by three orders of magnitude in mJ with increasing XO2 and the addition of CH4/H2. Compared with CH4, H2 had a relatively strong promotion effect on the spark ignition of coal dusts. The inhibiting effect of CO2 was found to be much stronger than N2, but this inhibiting effect of CO2 could be eliminated by 9% increment of XO2. The effect on MIE of coal dusts thus followed by the order: 9% increment of XO2 > CO2 replacing N2 > 2% CH4 or H2 addition. Moreover, two empirical models were used to estimate the MIE of hybrid dust-gas mixture (HMIE), and the results showed that calculated data can well reflect the promoting effect of elevated XO2 and flammable gas addition, and the inhibiting effect of inert gas
Due to the high damping mechanical properties of fibreboard materials, corrugated fibreboard boxes are widely used as transport packages of dangerous goods.
Since there is a hazard of vertical impact within the distribution system, drop tests are performed as design type tests to assess the package’s ability to withstand damage. However, there is little information in this context regarding the mechanical response of a filled fibreboard box.
This work aims to propose a concept utilizing experimental drop test results by means of finite-element (FE) analyses in order to predict the damage resistance of complete, filled corrugated fibreboard boxes which are ready for transportation.
Overview of the state of the art and current trends with the main topics:
- renewable sources in flame retardant polymers (flame retarded bio-polymers and biocomposites; bio-flame retardants, renewable adjuvants from industrial waste)
- flame retardancy meets sustainability
- concepts between analogy and out-of-the-box.
Im Projekt InnoBOSK wurden insgesamt vier wissenschaftlich basierte Bedarfserhebungsworkshops durchgeführt. Die Workshops hatten jeweils thematische Schwerpunkte und wurden mit Vertretern unterschiedlicher BOS (Behörden und Organisationen mit Sicherheitsaufgaben) durchgeführt.
In der vorliegenden Arbeit werden die erhobenen Bedarfe ausgewertet.
Fazit:
Nachteile der Schüttwinkel-Messmethoden:
Einschränkungen bei der Anwendbarkeit auf Füllgüter mit bestimmten Eigenschaften;
Die einzelnen Methoden liefern dann unterschiedliche Ergebnisse (statist. signifikante Abweichung der Mittelwerte);
Schlechte Wiederholbarkeit;
Bedienereinfluss spielt Rolle;
Gewährleistung des Arbeitsschutzes schwierig;
Bestimmung des Hausner-Faktors:
Keins dieser Defizite
Mögliche Abhilfemaßnahmen:
Prüfbericht und Zulassungsschein sollten zumindest die Methode angeben, die zur Messung des Schüttwinkels 𝛼 eingesetzt wurde;
Einheitliches Verfahren zur Schüttwinkelmessung (DIN-Methode)?
Umstellung des Systems auf einen alternativen Parameter zur Bestimmung der Fließeigenschaften:
Hausner-Faktor 𝐻:
Bessere Wiederholbarkeit der Ergebnisse;
Zuverlässige Anwendbarkeit auch auf Extremfälle von Schüttgütern;
Sicherere Handhabung von Gefahrgütern
Geophysical methods are able to contribute significantly to geotechnical site characterization. In-situ parameters are collected and gaps between boreholes or other direct tests are filled with information. However the limited resolution has to be considered and the indirect geophysical parameters have to be translated into something geotechnically useful. Moreover, the limitations have to be evaluated when including geophysical data into geostatistical models. If done properly, the use of geophysics will help in an efficient and effective site characterization. A comprehensive overview on existing geophysical (mostly seismic) methods is given as well as information on the calibration of geophysical against geotechnical parameters, pitfalls and limitations and some hints how to include these data into geostatistical/geotechnical models.
Hybrid cements are composites made of Portland cement or Portland clinker and one or more supplementary cementitious materials like slag, fly ash or metakaolin, activated with an alkali salt. To date, their hydration mechanism and the phase formation at various temperatures is insufficiently understood, partly due to the large variability of the raw materials used. In the present study, three hybrid cements based on ground granulated blast furnace slag, fly ash, Portland clinker and sodium sulfate, and an alkali-activated slag/fly ash blend were cured at 10 and 21.5°C, and subsequently analyzed by XRD, 27Al MAS NMR, and TGA. The compressive strength of the hybrid cements was higher by up to 27% after 91-day curing at 10°C, compared to curing at 21.5°C. The experimental results as well as thermodynamic modeling indicate that the differences in compressive strength were related to a different phase assemblage, mainly differing amounts of strätlingite and C-N-A-S-H, and the associated differences of the volume of hydration products. While the strätlingite was amorphous to X-rays, it could be identified by 27Al MAS NMR spectroscopy, TGA and thermodynamic modeling. The microstructural properties of the hybrid cements and the alkali-activated slag/fly ash blend as well as the compatibility between thermodynamic modeling results and experimental data as a function of curing temperature and time are discussed.