Infrastruktur
Filtern
Erscheinungsjahr
- 2022 (305) (entfernen)
Dokumenttyp
- Vortrag (138)
- Zeitschriftenartikel (77)
- Beitrag zu einem Tagungsband (51)
- Posterpräsentation (15)
- Sonstiges (7)
- Buchkapitel (6)
- Forschungsbericht (5)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
Schlagworte
- Korrosion (20)
- Corrosion (19)
- Concrete (18)
- Ultrasound (13)
- Potentialfeldmessung (10)
- Structural health monitoring (10)
- Brandschutz (8)
- Brückenbeläge (8)
- Spannungsrisskorrosion (8)
- Distributed acoustic sensing (7)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (180)
- 8 Zerstörungsfreie Prüfung (84)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (54)
- 7.6 Korrosion und Korrosionsschutz (45)
- 7.2 Ingenieurbau (39)
- 2 Prozess- und Anlagensicherheit (36)
- 2.1 Sicherheit von Energieträgern (25)
- 3 Gefahrgutumschließungen; Energiespeicher (24)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (24)
- 7.1 Baustoffe (23)
Paper des Monats
- ja (7)
Eingeladener Vortrag
- nein (138)
To reveal the corrosion resistance of casing steel/mortar interface in CO2 injection condition, sandwich samples were prepared and exposed up to 20 weeks in aquifer fluid under 10 MPa and 60 °C. Cross section analysis revealed the crevice corrosion as main mechanism instead of pitting corrosion, which would be expected to happen in the extremely high Chloride concentration. Detailed analysis using EDS line scan shown the slow diffusion of Chloride, suggesting why pitting did not happen after 20 weeks. To mimic the passivated steel surface, the steel coupon was passivated in simulated pore solution having pH 13.5 for 42 days. The passivated coupon was further exposed to NGB solution for 28 days. Electrochemical characterization was performed along the exposure processes to reveal the change in impedance, indicating the corrosion resistance of steel casing/mortar interface.
Introduction of a monitoring system for Bingham fluids in additive manufacturing with concrete
(2022)
Freeform additive manufacturing of concrete structures is a rising technology in civil engineering with several fascinating advantages. Nonetheless, to ensure reliability and structural integrity, standards and quality control are required in the future to bring this technology into the market. As the concrete is manufactured continuously, continuous quality control of the printing process is also required, i.e. comprehensive process monitoring. At BAM, a test rig will be installed, enabling the printing of concrete structures with a maximum size of 2 m x 1 m x 1 m (l x w x h). Here, process monitoring is the focus of the test rig. In this study, we show the results of the first pump tests, including the measurement of several parameters such as temperature and pressure along the supply system, i.e. from the concrete pump to the printer head.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.
This contribution introduces an investigation of a large-scale prestressed concrete bridge model (“BLEIB” structure at the BAM-TTS open air test site) by means of on-site cooperative measurements. This bridge has an external post-tensioning system and has been instrumented with the ultrasonic transducers, temperature sensors and optical fibers for Distributed Acoustic Sensing (DAS). Our experiment was designed to test the suitability of the novel 6C sensors developed within the framework of the GIOTTO project – the IMU50. The IMU50 sensor enables vibration measurements in translation along three axes and rotation around three axes. The geophone sensors were considered for complementary measurements of vertical velocity response. In the experiment, several perturbations were achieved by controlling the external influence factors such as loading and prestressing changes. The aim of the integrated measurement strategy was to fully observe the results of the condition change and to verify the effectiveness of multiple sensors for bridge monitoring.
Significant Cu-deposition and ‑precipitation only occurred in combination with carbon steel. High-alloyed materials prevent the disturbing Cu-agglomeration. Pb-deposition and ‑precipitation only occurred in combination with carbon steel. No negative Pb-effect could be observed in combination with high-alloyed steels. High alloyed corrosion resistant alloys are suitable and shall be chosen for future design of the piping system, either in massive or in cladded form, if formation of crevices with non-metallic materials can be excluded!
To reveal the corrosion resistance of casing steel/mortar interface in CO2 injection condition, sandwich samples were prepared and exposed up to 20 weeks in aquifer fluid under 10 MPa and 60 °C.
Cross section analysis revealed the crevice corrosion as main mechanism instead of pitting corrosion despite very high concentration of Cl in NGB.
EDS element line scan analysis of the 20-week-exposed metal/mortar coupon showed Chloride distribution, which still not reached the metal/mortar interface, explaining no pitting was observed.
It was confirmed that FeCO3 cannot protect the steel surface in CO2 saturated NGB.
To verify the protective possibility of passivation happened on casing steel/mortar interface, simulated pore solution was synthesized and used to passivate the steel for 42 days. OCP and EIS confirmed the formation of passive layer.
The 42 day passivated layer was broken during the first minute of exposure in CO2 saturated NGB.
However, due to high concentration of Ca2+, a new carbonate CaCO3 dense layer was formed, increased the corrosion resistance of steel surface.
In the course of the deconstruction of the "Bridge of the 20th anniversary of the GDR" at the Altstädter Bahnhof in Brandenburg a. d. Havel, new information on the initiation of hydrogen-induced stress cracks was obtained. BAM was commissioned by the Brandenburg State Road Administration to participate in a corresponding joint project which is financed by the Federal Ministry for Digital and Transport. The added value of the new information gained in this project goes beyond the specific structure. It describes unexpected new damage patterns that can be transferred to other structures with concentrated tendons (tendon block method and Baur-Leonhardt method) and were previously unknown in this form. These should be made known to other developers to enable them to initiate any necessary actions.
Due to the high corrosivity that are present in road tunnel structures, cleaning and maintenance work on stainless steel components in the tunnels is carried out at regular intervals in the tunnels, which means that parts of the lanes or the whole tunnel have to be temporarily closed. To reduce these traffic disruptions and maintenance costs, it is important to reduce the work that is needed for cleaning and maintenance of stainless steel components in road tunnels. One possibility is the identification and utilization of better suited alternatives to the commonly used austenitic stainless steels AISI 316L and AISI 316Ti. Thus, a field exposure study was carried out in different road tunnels throughout Germany to qualify different duplex and lean duplex stainless steels for tunnel constructions.
The proposed scientific poster gives an overview of results after the first three years of exposure in three different road tunnels. Samples of different stainless steels were placed in different areas of the tunnel – at lane height and at the ceiling. Some samples were exposed under sheltered conditions. Pit depths were evaluated on the free surface and in crevice areas after each year of exposure. The investigations show that duplex stainless steels have a comparable or even better corrosion resistance than austenitic steels in tunnel atmospheres.
Numerical models built as virtual-twins of a real structure (digital-twins) are considered the future ofmonitoring systems. Their setup requires the estimation of unknown parameters, which are not directly measurable. Stochastic model identification is then essential, which can be computationally costly and even unfeasible when it comes to real applications. Efficient surrogate models, such as reduced-order method, can be used to overcome this limitation and provide real time model identification. Since their numerical accuracy influences the identification process, the optimal surrogate not only has to be computationally efficient, but also accurate with respect to the identified parameters. This work aims at automatically controlling the Proper Generalized Decomposition (PGD) surrogate’s numerical accuracy for parameter identification. For this purpose, a sequence of Bayesian model identification problems, in which the surrogate’s accuracy is iteratively increased, is solved with a variational Bayesian inference procedure. The effect of the numerical accuracy on the resulting posteriors probability density functions is analyzed through two metrics, the Bayes Factor (BF) and a criterion based on the Kullback-Leibler (KL) divergence. The approach is demonstrated by a simple test example and by two structural problems. The latter aims to identify spatially distributed damage, modeled with a PGD surrogate extended for log-normal random fields, in two different structures: a truss with synthetic data and a small, reinforced bridge with real measurement data. For all examples, the evolution of the KL-based and BF criteria for increased accuracy is shown and their convergence indicates when model refinement no longer affects the identification results.
Damage Assessment of Civil Structures Using Wave Propagation Analysis and Transmissibility Functions
(2022)
A common damage detection method in civil engineering is to monitor dynamic characteristics such as natural frequencies and modal shapes, which are directly related to the structural stiffness. However, the discrepancy in measured natural frequencies may result from environmental changes, the soil-structure interaction or effects caused by earthquakes. This makes it difficult to decide whether the local change in structural properties is caused by damage or other factors. To address this challenge and thus improve the current damage detection method, the wave propagation analysis method and the transmissibility relationship were considered. In our study, the wave propagation field in structures was reconstructed by applying the Normalized-Input-Output-Minimization (NIOM) method to vibration recordings. Wave velocities and transmissibility functions were considered as reference values for the damage indicators. This paper demonstrates the evaluation of local property changes in two examples of large-scale structures: a 14-story RC building and a 64 m long pedestrian bridge. The proposed damage indicators show a clear correspondence to structural changes.