Infrastruktur
Filtern
Erscheinungsjahr
- 2022 (138) (entfernen)
Dokumenttyp
- Vortrag (138) (entfernen)
Referierte Publikation
- nein (138)
Schlagworte
- Korrosion (16)
- Corrosion (13)
- Potentialfeldmessung (9)
- Concrete (7)
- Geothermal (5)
- Spannungsrisskorrosion (5)
- Ground vibration (4)
- Hydrogen (4)
- Bridge (3)
- Coda wave interferometry (3)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (86)
- 8 Zerstörungsfreie Prüfung (36)
- 7.6 Korrosion und Korrosionsschutz (31)
- 7.2 Ingenieurbau (19)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (19)
- 2 Prozess- und Anlagensicherheit (16)
- 3 Gefahrgutumschließungen; Energiespeicher (15)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (10)
- 7.7 Modellierung und Simulation (10)
- 2.1 Sicherheit von Energieträgern (8)
Eingeladener Vortrag
- nein (138)
Emanating from developing flame retarded biocomposites, we have proposed renewable natural fibers (including keratin) taken from industrial waste as an authentic sustainable approach. More recently, we have investigated non-vegan flame retardant approaches. This paper loves to give you an insight into our ongoing projects on biogenic industrial wastes like leather, bone meal, and insects. Materials were characterized multi-methodically, flame retardant modes of action quantified, decomposition mechanism proposed, and synergisms explained. Considering the large quantities of leather waste (LW) in industrial-scale production, we underline LW as multifunctional bio-adjuvants. LW enhances the flame retardancy of poly(ethylene-vinyl acetate) (EVA) containing phosphorus flame retardants (P-FR). Products/by-products of the invertebrate and vertebrate farming, respectively, are promising bio-based adjuvants in flame retarded bio-epoxy thermosets. While the addition of bone meal yields the formation of an inorganic shield, protein-based powders from insects provide an intumescent behavior. In combination with a P-FR superior charring and self-extinguishing are obtained.
Acknowledgement: In part of this work was supported by the Volkswagen Foundation grant “Experiment!” No. 97437.
Es werden Ergebnisse von 1H-NMR-Relaxometrie-Messungen an Salzbeton und einem alkali-aktivierten Material, die im Rahmen des Themenfeldprojektes Seal Waste Safe durchgeführt werden, vorgestellt. Dabei wird die zeitliche Entwicklung von ausgewählten Merkmalen der ermittelten T2-Relaxationszeitenverteilungen während der Hydratation betrachtet. Als Referenz zur Identifikation von charakteristischen Hydratationsereignissen dienen der Vicat-Nadeleindringversuch und Wärmeflusskalorimetrie.
Nach einer kurzen Einführung in die Schallemissionsprüfung und -Analyse wird ein Versuchsstand vorgestellt, der im Rahmen des Themenfeldprojektes Seal Waste Safe installiert wurde. Schwerpunkt des Vortrages sind die Schallemissionsmessungen an einem 150 l Demonstrator aus Salzbeton und einem weiteren aus alkali-aktiviertem Material. Neben der konventionellen Schallemissionsanaylse mit Aktivitäts- und Intensitätsparametern der Zeitsignale, werden auch frequenzbasierte Parameter zur Analyse andiskutiert.
Renewable alternatives for common thermoset resins are demanded to go for sustainability. The objective is to create a flame retarded epoxy resin from a commercial bio epoxy resin with halogen free inorganic and organic flame retardants, respectively. Alumina trihydrate, aluminum diethyl phosphinate, a DOPO-based phosphonamidate and ammonium polyphosphate seem to have promising performances. Properties are enhanced with different bio fillers: pyrolyzed cocoa shells and plant waste (provided by Otto A. Müller Recycling GmbH, thanks!), short fibers and nonwovens of the natural fiber kenaf, hydroxypropyl-ß-cyclodextrin and sulfobutylether-ß-cyclodextrin.
Fire performance is investigated by cone calorimeter examinations, LOI and UL-94 ratings. Thermal analysis is given by TG-FTIR and DSC measurements.
Combinations of flame retardants and bio-fillers lead to reduced PHRR and THR, reach V0 in UL-94 and have a significant increase in LOI of up to 37 vol.-%. 10 % ammonium polyphosphate with 10 % pyrolyzed cocoa shell performs best, builds a magnificent protective layer, and shows good intumescence.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or poorly accessible areas. A challenging task however, is the generation of three-dimensional distribution maps from these spatially sparse gas measurements. To obtain high-quality reconstructions, the choice of optimal measuring poses is of great importance. Remote gas sensors, that are commonly used in Robot Assisted Gas Tomography (RAGT), require reflecting surfaces within the sensor’s range, limiting the possible sensing geometries, regardless of whether the robots are ground-based or airborne. By combining ground and aerial robots into a heterogeneous swarm whose agents are equipped with reflectors and remote gas sensors, remote inter-robot gas measurements become available, taking RAGT to the next dimension – releasing those constraints. In this paper, we demonstrate the feasibility of drone-to-drone measurements under realistic conditions and highlight the resulting opportunities.
Dieser Vortrag präsentiert einige Prinzipien und einige Beispiele zur Minderung von Eisenbahnerschütterungen. Die Prinzipien unterscheiden sich für die Minderungsmaßnahmen im Gleis, im Boden und bei Gebäuden. Kraftübertragungsfunktionen isolierter und nicht isolierter Gleissysteme, reflektierte und durchgelassene Wellenamplituden bei gefüllten Bodenschlitzen und die Übertragung der Freifeldschwingungen ins Gebäude werden analysiert. Bei den einfachen Gleismodellen muss der richtige Anteil der unabgefederte Fahrzeugmasse zum eindimensionalen Gleismodell hinzugefügt werden. Der Minderungseffekt eines gefüllten Bodenschlitzes ist von der Steifigkeit und nicht von der Impedanz des Schichtmaterials bestimmt. Bei einer elastischen Gebäudelagerung muss die Minderungswirkung mit der richtigen Boden- (Fundament-) Steifigkeit berechnet werden, und das abgeminderte Gebäudeverhalten hängt wesentlich von der effektiven Gebäudemasse ab, die mit zunehmender Frequenz deutlich kleiner als die starre Gebäudemasse ist.
The general requirement, that nonmetallic materials for oxygen service must be tested and found suitable for their intended use in plants and components is the current state of technical safety. However, numerous requests of manufacturers, sales offices, and users show, that there is still a strong need for information on how these materials are tested and evaluated. Based on more than 60 years of expertise, this paper provides background information on BAM’s test approach. It explains why BAM applies additional assessment criteria on nonmetallic materials for certain use conditions. Hence, the test schedule as well as the final evaluation shall reflect the practical application in a more customer-related way in combination with a higher safety level. That is the demand of BAM’s safety philosophy.
Die Präsentation zeigt in Bild und Video die Möglichkeiten auf dem BAM TTS zur Durchführung von Versuchen unterschiedlicher Gefährlichkeitsstufen auf. Sie wendet sich an potentielle künftige Kooperationspartner aus dem Bereich der zivilen Sicherheitsforschung (Polizeibehörden, Feuerwehr, THW, andere Forschungseinrichtungen), um deren Forschungsbedarf mit den an der BAM vorhandenen Testmöglichkeiten abzugleichen und so ebenfalls dem Aufbau von überflüssigen konkurrierenden Parallelstrukturen an anderen Forschungseinrichtungen vorzubeugen.
Wasserstoffinduzierte Spannungsrisskorrosion an hochfesten und hochempfindlichen Spannstählen führt an bestehenden Brückenbauwerken nach Jahren der Rissinitiierung zu Trag- und Standsicherheitsverlusten. Anhand des Beispiels der Brücke am Altstädter Bahnhof gibt es eine bauartbedingte Schadensinitiierung die über den gesamten Spannkanalquerschnitt zu Spannungsrisskorrosion führen kann.
Die Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. Bei der Durchführung dieser Messung gibt es jedoch messtechnikspezifische Fehlerquellen und äußere Einflüsse aus dem zu untersuchenden Bauwerk die eine Interpretation der Messergebnisse signifikant beeinflussen können.