Infrastruktur
Filtern
Erscheinungsjahr
- 2022 (305) (entfernen)
Dokumenttyp
- Vortrag (138)
- Zeitschriftenartikel (77)
- Beitrag zu einem Tagungsband (51)
- Posterpräsentation (15)
- Sonstiges (7)
- Buchkapitel (6)
- Forschungsbericht (5)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
Schlagworte
- Korrosion (20)
- Corrosion (19)
- Concrete (18)
- Ultrasound (13)
- Potentialfeldmessung (10)
- Structural health monitoring (10)
- Brandschutz (8)
- Brückenbeläge (8)
- Spannungsrisskorrosion (8)
- Distributed acoustic sensing (7)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (180)
- 8 Zerstörungsfreie Prüfung (84)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (54)
- 7.6 Korrosion und Korrosionsschutz (45)
- 7.2 Ingenieurbau (39)
- 2 Prozess- und Anlagensicherheit (36)
- 2.1 Sicherheit von Energieträgern (25)
- 3 Gefahrgutumschließungen; Energiespeicher (24)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (24)
- 7.1 Baustoffe (23)
Paper des Monats
- ja (7)
Eingeladener Vortrag
- nein (138)
Influence of the hydroxypropylation of starch on its performance as viscosity modifying agent
(2022)
Synopsis: Starch is a commonly used viscosity modifying agent (VMA). The performance of starch as VMA depends on its origin (e.g. potato, corn, cassava, etc.) and corresponding molecular properties, such as molecular weight, ratio between amylose and amylopectin etc. Depending upon the application, the efficiency of starch can be enhanced by hydroxypropylation. The maximum degree of substitution (DoS) cannot be greater than 3.0, which is the number of hydroxy groups per glucose monomer in the polymer. In the current research three potato starches exhibiting the DoS of 0.4, 0.6 and 0.8 were utilised. The influence of the modified starch on the rheological properties and hydration of cement paste, as well as the viscosity of the pore solution were investigated. Our findings show that the starch with the highest DoS increases the dynamic yield stress the most, while the plastic viscosity is less dependent on the DoS. Additionally, starch with the highest DoS retards hydration to lower degree than other starches.
Organic admixtures are an indispensable component of modern concrete. Thus, their purposeful application is not only technically and economically viable but in addition an inevitable tool to make concrete more environmentally friendly. In this context, the use of polysaccharides has increasingly gained interest in the built environment as sustainable resource for performance enhancement. However, due to its origin, biopolymers possess a vast variety of molecular structures which can result in incompatibilities with other polymers present in concrete, such as superplasticizers. The present study highlights effects of the joint application of different types of starches and polycarboxylates with respect to their influence on cement hydration and structural build-up of cement pastes.
The current paper develops a novel accelerated corrosion test method based on Faraday’s law to investigate the performance of different inhibitors in reinforced concrete elements under electrical voltage. Using the proposed method two commercially available and three lab-made inhibitors were tested. Lab-made inhibitors based on potassium fluorosilicate and amine carboxylate showed the best performance over others. Furthermore, it is found that under an electrical potential environment beyond 3.6 V, the higher the concrete strength, the more efficient is the corrosion inhibition. Based on experimental results, a novel model describing the corrosion evolution in reinforced concrete was proposed.
The structural build-up of fresh cement paste is often considered as a purely thixotropic phenomenon in literature even though cementitious materials undergo a non-reversible hydration process that can have an influence on the structuration process. In the current paper a method is proposed to validate the impact of the non-reversible structural build-up. It is shown that fresh cement paste samples lose their structural gain almost completely due to thixotropy while the structural build-up due to hydration can be observed but occurs in a significantly lower order of magnitude over the course of the first hours of hydration. In addition, it is shown, that the chemical component of the structural build-up accelerates with the onset of the acceleration period of hydration, while its contribution in the entire structural build-up remains constant.
The retardation mechanism of cement hydration as imparted by the addition of polyphosphate comb superplasticizer to model cement containing C3S, C3A and calcium sulfate hemihydrate is studied using XRD, ss NMR and calorimetry. Our findings show the retardation effect caused by the direct addition of polyphosphate comb superplasticizer differs significantly to that of conventional polycarboxylate superplasticizers. Conversely to polycarboxylates, polyphosphates, at a low dosage, inhibits the silicate reaction without affecting the aluminate reaction and formation of ettringite. Yet, at high doses, both reactions are hampered, and the induction period extended, followed by accelerated aluminate and silicate reactions.
Ein zentrales Fundament moderner Gesellschaften ist eine intakte Abwasserinfrastruktur. Schäden infolge biogener Schwefelsäurekorrosion von konventionellen Betonen haben jedoch zu einem erheblichen Sanierungsbedarf geführt. Alkaliaktivierte Mörtel besitzen aufgrund eines hohen Säurewiderstands das Potential, einen Beitrag zur langfristigen Lösung dieses Problems zu leisten. Dazu müssen jedoch zunächst die Faktoren, die den Haftverbund zwischen diesen Mörteln und dem Betonsubstrat bestimmen, besser verstanden werden, um die Eigenschaften der Beschichtungssysteme gezielt anpassen und verbessern zu können. Die vorliegende Arbeit liefert hierzu einen Beitrag und zeigt dadurch Wege zu einer technisch machbaren und nachhaltigen Sanierung von Abwasserbauwerken auf.
Multiscale modeling of heterogeneous structures based on a localized model order reduction approach
(2022)
Many of today’s problems in engineering demand reliable and accurate prediction of failure mechanisms of mechanical structures. Thus, it is necessary to take into account the heterogeneous structure on the smaller scale, to capture the underlying physical phenomena. However, this poses a great challenge to the numerical solution since the computational cost is significantly increased by resolving the smaller scale in the model. Moreover, in applications where scale separation as the basis of classical homogenization schemes does not hold, the influence of the smaller scale on the larger scale has to be modelled directly. This work aims to develop an efficient concurrent methodology to model heterogeneous structures combining the variational multiscale method (VMM) and model order reduction techniques. First, the influence of the smaller scale on the larger scale can be taken into account following the additive split of the displacement field as in the VMM. Here, also a decomposition of the global domain into subdomains, each containing a fine grid discretization of the smaller scale, is introduced. Second, local reduced approximation spaces for the smaller scale solution are constructed by exploring possible solutions for each subdomain based on the concept of oversampling and the solution of the associated transfer operator problem. Herein, we propose to choose the training data based on the solution of a reduced global problem to incorporate the actual physical behaviour of the structure of interest and to extend it by random samples to ensure sufficient approximation capabilities in general. The local reduced spaces are designed such that local contributions of each subdomain can be coupled in a conforming way. Thus, the resulting global system is sparse and reduced in size compared to the direct numerical simulation, leading to a faster solution of the problem.
The authors gratefully acknowledge financial support by the German Research Foundation (DFG), project number 394350870, and by the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (ERC Grant agreement No. 818473).
Im Rahmen des Forschungsprojektes IGF 20470N wurden Untersuchungen zum Alterungsverhalten von reaktiven Brandschutzsystemen (RBS) auf Stahlbauteilen durchgeführt. Mithilfe der Ergebnisse einer umfangreichen Literaturrecherche sowie experimentellen und numerischen Untersuchungen sollte ein Vorschlag für ein Prüfkonzept zum Nachweis einer Nutzungsdauer von RBS von mehr als 10 Jahren auf Basis von Kurzzeitversuchen abgeleitet werden. Dabei setzt die Bewertung des Alterungsverhaltens von RBS voraus, dass die Mechanismen der Alterung hinreichend bekannt sind.
Dafür wurden zunächst systematisch Daten von Kurz- und Langzeitversuchen von nationalen Zulassungsprüfungen der letzten Jahrzehnte ausgewertet. Anschließend wurden umfangreiche experimentelle Untersuchungen an einer wasserbasierten sowie einer epoxidharzbasierten Richtrezeptur durchgeführt. Da aus der Literatur bekannt ist, dass die Einflüsse der Bewitterung zu einer Veränderung der Konzentration der Bestandteile innerhalb der Beschichtung führen können, wurden Untersuchungen mit Mangelrezepturen durchgeführt, wobei systematisch einzelne Bestandteile reduziert wurden. Neben optischen Untersuchungen wurden thermoanalytische Verfahren (DSC-TG-, ATR-FTIR-, Elementar-, Farbanalyse) angewandt sowie Brandversuche an beschichteten Stahlplatten durchgeführt. Des Weiteren wurden die Richtrezepturen den beschleunigten Kurzzeitversuchen gemäß EAD 350402-00-1106 (2017) unterzogen, welche die Zulassung von Produkten auf europäischer Ebene regelt. Für die wasserbasierte Richtrezeptur wurden die Bewitterung für den feuchten Innenraum (Typ Z1) mehrfach wiederholt (1x, 3x, 6x). Für die epoxidharzbasierte Richtrezeptur entsprach die Bewitterung dem Zyklus für die Außenanwendung (Typ X). In Brandversuchen sowie thermoanalytischen und optischen Untersuchungen wurde das Alterungsverhalten sowie die thermische Schutzwirkung analysiert.
Anschließend wurden numerische Simulationen von Stahlbauteilen mit gealterten RBS durchgeführt und anhand der experimentellen Untersuchungen validiert. Mithilfe der numerischen Modelle kann eine Bewertung der thermischen Schutzwirkung von Stahlbauteilen mit gealterten RBS vorgenommen werden.
Mithilfe der gesammelten Erkenntnisse wurde ein Vorschlag für ein Prüfkonzept für den Nachweis einer Nutzungsdauer von mehr als 10 Jahren abgeleitet. Das Prüfkonzept besteht dabei aus einem Katalog von Möglichkeiten, die aktuellen Zulassungsprüfungen auf europäischer Ebene für eine Nutzungsdauer von 10 Jahren auf einen längeren Zeitraum zu erweitern.
Ein Aspekt des Gefahrguttransportes, der an Bedeutung in den letzten Jahren zugenommen hat, ist die Versorgung von Wasserstofftankstellen und anderen H2-Großverbrauchern über die Schiene aber insbesondere über die Straße.
Mit Blick auf die primäre Form der Speicherung wird der Begriff der Sicherheit über den Aspekt der Häufigkeit eines definierten Ereignisses erläutert und auf die Besonderheiten der Druckgefäße aus Verbundwerkstoffen hingewiesen, wie auch den regulatorischen Hintergrund der Lebensdauerüberprüfung nach 15 Jahren nach den Vorgaben der zuständigen Behörde. In Deutschland sind diese Vorgaben in der BAM-Gefahrgutregel 021 geregelt, die in der GGR 022 durch eine Regelung zur Wiederkehrenden Prüfung dieser Umschließungen ergänzt wird.
Beide BAM-Gefahrgutregeln basieren auf einem probabilistischen Ansatz und einer Konsequenzabschätzung über das Druck-Volumen-Produkt der Druckgefäße. Die neu im Recht verankerte EN 17339 ist die erste Norm, die speziell fest montierte Compositespeicher für den Wasserstofftransport regelt. Sie ermöglicht eine erhebliche Gewichtreduktion und führt eine Obergrenze für das Druckvolumen ein.
Es wird kurz erläutert, dass gerade mit Blick auf Wasserstofftransporte über eine Arbeitsgruppe der Vereinten Nationen eine Begrenzung des Konsequenzpotentials in das internationale Recht eingeführt werden soll und welche Kriterien bei der systematischen Ermittlung des akzeptierten Wertes von 1.5 Mio bar Liter Einfluss haben.
Mit Blick auf die Energiewende sieht es die BAM als besonders wichtig an, die Transportkosten zu senken, indem der Prüfaufwand reduziert und gleichzeitig die Erkenntnistiefe aus der betrieblichen Überwachung verbessert wird. Hierzu muss die Datenbasis für die probabilistische Bewertung der Lebensdauer von zerstörenden Prüfungen auf zerstörungsfreie Prüfungen umgestellt werden und idealerweise die 100% Prüfung zumindest in der ersten Hälfte des sicheren Lebens auf Stichproben reduziert werden.
Dies und andere Aufgaben, die wichtig für eine sichere und attraktive Wasserstoffwirtschaft sind werden von dem Kompetenzzentrum H2Safety@BAM bearbeitet, dass in seinen Grundzügen kurz vorgestellt wird.