Elektrische Energiespeicher und -umwandlung
Filtern
Dokumenttyp
Schlagworte
- Lithiumbatterien (15)
- Fibre break (11)
- Lithium Ion Batteries (10)
- Lithium-ion battery (10)
- Multiscale model (10)
- Lithium-ion batteries (9)
- Auswirkungsbetrachtungen (8)
- Elektrische Energiespeicher (8)
- Reduced volume method (8)
- Stationäre Energiespeicher (8)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (119)
- 3.0 Abteilungsleitung und andere (55)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (51)
- 8 Zerstörungsfreie Prüfung (40)
- 2 Prozess- und Anlagensicherheit (32)
- 2.1 Sicherheit von Energieträgern (30)
- 1 Analytische Chemie; Referenzmaterialien (26)
- 5 Werkstofftechnik (25)
- 8.5 Röntgenbildgebung (22)
- 6 Materialchemie (19)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (112)
Guided waves cover comparably long distances and thus allow for online structural health monitoring of safety relevant components, e.g. lightweight composite overwrapped pressure vessels (COPV) as used for the transportation of pressurised gases. Reliable non-destructive assessment of COPVs’ condition is not available yet due to their complex composite structure comprising a thin metal liner and a fibre reinforced plastics (FRP) overwrap. The conventional overload hydrostatic pressure testing used for the metal vessels is not suitable for the composite vessels, because it may damage the FRP overwrap reducing the service life of the COPV. Therefore, ISO and CEN defined a maximum service life of composite pressure vessels as of 15 to 20 years. To extend the COPVs’ service life and to ensure a safer usage a structural health monitoring system based on guided ultrasonic waves is to be developed.
In this contribution first results of guided waves propagation in a flat composite plate consisting of an aluminium layer firmly bonded to a carbon fibre reinforced plastic laminate are presented. Based on experimental results material properties of FRP are reconstructed by means of the Scaled Boundary Finite Element Method (SBFEM).
Guided waves cover comparably long distances and thus allow for online structural health monitoring of safety relevant components, e.g. lightweight composite overwrapped pressure vessels (COPV) as used for the transportation of pressurised gases. Reliable non-destructive assessment of COPVs’ condition is not available yet due to their complex composite structure comprising a thin metal liner and a fibre reinforced plastics (FRP) overwrap. The conventional overload hydrostatic pressure testing used for the metal vessels is not suitable for the composite vessels, because it may damage the FRP overwrap reducing the service life of the COPV. Therefore, ISO and CEN defined a maximum service life of composite pressure vessels as of 15 to 20 years. To extend the COPVs’ service life and to ensure a safer usage a structural health monitoring system based on guided ultrasonic waves is to be developed.
In this contribution first results of guided waves propagation in a flat composite plate consisting of an aluminium layer firmly bonded to a carbon fibre reinforced plastic laminate are presented. Based on experimental results material properties of FRP are reconstructed by means of the Scaled Boundary Finite Element Method (SBFEM).
Most of the experimental density data of the methane−hydrogen binary system available at the time of the development of the equation of state for natural gases and related mixtures, GERG-2008, at temperatures above 270 K were limited to hydrogen contents higher than 0.20 (amount-of-substance fraction). On the contrary, for mixtures with hydrogen contents lower than 0.20, experimental data were limited to temperatures below 270 K. This work intends to close the gap and provides accurate experimental (p, ρ, and T) data for three binary mixtures of methane and hydrogen, (0.95 CH4 + 0.05 H2), (0.90 CH4 + 0.10 H2), and (0.50 CH4 + 0.50 H2), at temperatures of 240, 250, 260, 275, 300, 325, and 350 K, thus extending the range of available experimental data to higher temperatures for mixtures with hydrogen contents lower than 0.20 and, accordingly, to lower temperatures for mixtures with hydrogen contents higher than 0.20. The density measurements were performed by using a single-sinker densimeter with magnetic suspension coupling at pressures up to 20 MPa. Experimental data were compared to the corresponding densities calculated from the GERG-2008 and the AGA8-DC92 equations of state, respectively. The experimental data are within the uncertainty of both equations of state, except at the lower temperatures of 240 and 250 K and pressures over 14 MPa for the mixtures with a hydrogen content of 0.05 and 0.10, respectively. The virial coefficients B(T, x) and C(T, x), as well as the second interaction virial coefficient B12(T) for the methane−hydrogen binary system, were also calculated from the experimental data set at temperatures from 240 to 350 K using the virial equation of state.
Defining a reduced volume zone for the simulation of burst test on composite pressure vessels
(2018)
The developed model uses a Monte-Carlo simulation to evaluate the accumulation of fibre breaks on composite structures. As the micromechanical aspects affecting the accumulation process is evaluated within a particular finite element size (0.1 mm x 0.1 mm x 8 mm), the industries would not be able to use the model on a real-size structure. Therefore, the reduced volume method is used to provide the statistical information between the required number of elements and simulations.
The fibre-break model developed at Mines ParisTech has been able to show the effect of pressurisation rate on pressure vessels. This simulation however had to use a smaller model, as the computation time becomes enormous for simulating a real-scale pressure vessel. Reduced volume method then has been studied on different model configuration. The study showed that the method can be used only on certain configurations. It also gives a positive insight to reduce the computation time.
The present study investigated decoration of Cu(OH)₂ with different morphologies by copper precursors on 3D nickel foam. The Cu(OH)₂-A (nano flower)electrode showed an excellent capacitance of 1332 Fg⁻¹ at current density of 2 Ag⁻¹ compared to the Cu(OH)₂-C (nano ribbon, 1100 Fg⁻¹) and Cu(OH)₂-S (nano Long leaf, 1013 Fg⁻¹) electrodes. An asymmetric supercapacitor (ASC) was fabricated and showed a Maximum capacitance of 165 Fg⁻¹ at current density of 2 Ag⁻¹ with high energy density of 66.7 Wh kg⁻¹ and power density of 5698 W kg⁻¹ with excellent stability of 80 % after 10,000 cycles.
Effective hydrogen storage capacities are prerequisite for an efficient energy provision using fuel cells. Since glass has low intrinsic hydrogen permeability, it is a promising material for hydrogen storage containers as well as hydrogen diffusion barriers. Previous studies on oxidic glasses suggest a correlation between the glass composition and hydrogen permeation that was derived mainly from silica glass. In the present study, we concentrate on the relationship between thermodynamic (i.e., configurational entropy) and topologic (i.e., free volume, network polymerization) parameters. Experimental data were gathered well below the glass transition temperature, excluding significant effects caused by structural relaxation and chemical dissolution of hydrogen. The results of seven analysed glasses on the SiO2-NaAlO2 joint showed that the hydrogen permeability in fully polymerized glasses cannot solely be derived from the total free volume of the glass structure. Hence, evidence is provided that the size distribution of free volume contributes to hydrogen solubility and diffusion. Additionally, the results indicate that the configurational heat capacity ΔCp at Tg affects the hydrogen permeability of the investigated glasses.