S Qualitätsinfrastruktur
Filtern
Dokumenttyp
- Zeitschriftenartikel (34) (entfernen)
Schlagworte
- Certification (3)
- Energy label (3)
- Quality Infrastructure (3)
- Standards (3)
- Abgasanlage (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Circular economy (2)
- Conformity assessment (2)
- Digitalization (2)
Organisationseinheit der BAM
- S Qualitätsinfrastruktur (34)
- S.2 Digitalisierung der Qualitätsinfrastruktur (16)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (11)
- 1 Analytische Chemie; Referenzmaterialien (8)
- S.1 Qualität im Prüfwesen (7)
- 1.6 Anorganische Referenzmaterialien (4)
- 1.1 Anorganische Spurenanalytik (3)
- 1.3 Instrumentelle Analytik (2)
- 1.8 Umweltanalytik (2)
- 5 Werkstofftechnik (2)
- 5.1 Mikrostruktur Design und Degradation (2)
- 9 Komponentensicherheit (2)
- P Präsident (2)
- P.0 Präsident und andere (2)
- 1.2 Biophotonik (1)
- 1.4 Prozessanalytik (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (1)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 6 Materialchemie (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 6.2 Material- und Oberflächentechnologien (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.0 Abteilungsleitung und andere (1)
- 8.5 Röntgenbildgebung (1)
- 9.3 Schweißtechnische Fertigungsverfahren (1)
- 9.4 Integrität von Schweißverbindungen (1)
- 9.5 Tribologie und Verschleißschutz (1)
- PST Präsidiale Stabsstelle (1)
- S.0 Abteilungsleitung und andere (1)
Paper des Monats
- ja (1)
Die Ressourcen der Erde sind nicht nur endlich, sondern werden zudem ineffizient genutzt. Mit dem im Dezember 2015 verabschiedeten Aktionsplan zur Kreislaufwirtschaft fördert die Europäische Kommission den Übergang zur stärker kreislauforientierten Wirtschaft. So werden Anforderungen an Reparaturfähigkeit, Lebensdauer und Recyclingfähigkeit von Produkten zukünftig in der Ökodesign-Richtlinie gesetzt. Die Ökodesign-Richtlinie regelt momentan die Energieeffizienz von energieverbrauchsrelevanten Produkten. Um Anforderungen an den nachhaltigen Einsatz von Ressourcen zu formulieren, fehlen jedoch Normen und Definitionen. Diese Normen werden Momentan geschaffen - erst danach können gesetzliche Anforderungen folgerichtig umgesetzt werden.
The adsorption of water in one-dimensional channels in porous aluminophosphate material AlPO4-5 has been studied by a combination of gravimetric Analysis techniques, neutron and X-ray diffraction and Neutron spectroscopy. Molecular structure of AlPO4-5 consists of 12-membered rings of alternating, corner-sharing AlO4 and PO4 tetrahedra connected by oxygen bridges into sheets in the (a, b) plane. The sheets are connected by oxygen bridges along the c crystal axis and form onedimensional channels of which the largest, formed by the 12-membered rings, have a van der Waals Diameter of about 8.3 Å. Gradually increasing the amount of adsorbed water we could follow the evolution of the confined water mobility in a systematic way and identify the molecular mechanism of water adsorption. We focused particularly on the range of low and medium relative pressures up to p/p0=0.32, where a Change from a hydrophobic behavior to a steep, capillary condensation like water intake has been observed. At the Initial adsorption stages water occupies positions close to the pore walls causing the contraction of channels in the (a, b) plane and the prolongation of the channels along c axis in AlPO4-5. With the progressing intake water molecules form chains along the main channels. The cooperative interactions between water molecules lead to the onset of phonon-like cooperative modes and, surprisingly, to the increase of diffusive-like motion, which slow down only in the final adsorption stages when AlPO4-5 channels are completely filled.
Seit September 2015 gelten für neue Heizgeräte EU-weit einheitliche Mindeststandards: Heizkessel müssen mindestens den Standard der Brennwerttechnik erreichen (ausgenommen sind B1-Gasetagenheizungen für Mehrfachbelegung). Wird ein alter Wärmeerzeuger ausgetauscht, muss daher stets der Schornstein für die Abgasabführung im Überdruck geeignet sein und gegen Kondensat ertüchtigt werden, also feuchtebeständig sein. Handelt es sich um eine mehrfach belegte Abgasanlage der Arten C4, C8 oder B3, sind alle am Schornsteinstrang angeschlossenen Gasgeräte betroffen. In einem Expertengremium des DVGW wurden Handlungsempfehlungen erarbeitet. Einige Lösungsansätze vermeiden einen sofortigen Austausch aller Geräte an einem gemeinsamen Schornsteinstrang.
Seit September 2015 gelten für neue Heizgeräte EU-weit einheitliche Mindeststandards: Heizkessel müssen mindestens den Standard der Brennwerttechnik erreichen (ausgenommen sind B1-Gasetagenheizungen für Mehrfachbelegung). Wird ein alter Wärmeerzeuger ausgetauscht, muss daher stets der Schornstein für die Abgasabführung im Überdruck geeignet sein und gegen Kondensat ertüchtigt werden, also feuchtebeständig sein. Handelt es sich um eine mehrfach belegte Abgasanlage der Arten C4, C8 oder B3, sind alle am Schornsteinstrang angeschlossenen Gasgeräte betroffen. In einem Expertengremium des DVGW wurden Handlungsempfehlungen erarbeitet. Einige Lösungsansätze vermeiden einen sofortigen Austausch aller Geräte an einem gemeinsamen Schornsteinstrang.
Standardization research is a fairly new and is a still-evolving field of research, with possibly major practical ramifications. This article presents a summary of the authors’ subjective views of the most pressing research topics in the field. These include, among others, standards (e.g. incorporation of ethical issues), the potential impact of standards, the corporate management of standardization and legal issues like Intellectual Property Rights (IPR). In addition, gaps have been identified with a respect to a basic understanding of standardization, suggesting a need for better education in the field.
Highly ordered and highly cooperative water with properties of both solid and liquid states has been observed by means of neutron scattering in hydrophobic one-dimensional channels with van der Waals diameter of 0.78 nm. We have found that in the initial stages of adsorption water molecules occupy niches close to pore walls, followed later by the filling of the central pore area. Intensified by confinement, intermolecular water interactions lead to the formation of well-ordered hydrogen-bonded water chains and to the onset of cooperative vibrations. On the other hand, the same intermolecular interactions lead to two relaxation processes, the faster of which is the spontaneous position exchange between two water molecules placed 3.2-4 A from each other. Self-diffusion in an axial pore direction is the result of those spontaneous random exchanges and is substantially slower than the self-diffusion in bulk water.
Cost analysis of screening methods to find non-compliant models using the example of tumble dryers
(2019)
The European energy label was established to reduce energy consumption in Europe. All classes and values on the energy label are stated by the supplier. The task of market surveillance is to ensure correct labels and to validate their values through compliance tests. However, this can only be done for a small fraction of all models on the market, since physical tests are expensive. Screening methods can be used to narrow down the number of critical products before compliance tests are done to decrease the costs of finding non-compliant models.
This study shows a mathematical approach to analyze the cost benefits of screening methods to find non-compliant models. Furthermore, the analysis presented has been applied to 18 screening methods for tumble dryers. The performance test for tumble dryers consists of seven test runs. All screening methods evaluated are composed of a reduced number of test runs. The most efficient screening method reduces the surveillance costs by 40 %.
Minimum energy performance standards and labels are commonly used tools to reduce the household energy use thus mitigating greenhouse gas emissions. However, the technical foundation for minimum energy performance standards and labels are test procedures for rating and testing of appliances. To de- termine the seasonal cooling performance of air conditioners, the current test standards require fixing of the compressor speed of the units to achieve steady-state conditions; this way of operation, how- ever, differs from real-life use. To make the seasonal cooling performance testing better reflect the real use conditions, this study proposes a compensation method which can be conducted independently from manufacturer data and still allows modulation of the tested units. Our results show that the tested units behave differently under part-load conditions, which results in a lower energy efficiency rating for some of the tested devices.
Extraction, chromatographic separation, and quantification of low-concentration organic compounds in complex matrices are core challenges for reference material producers and providers of calibration services. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2014 the Organic Analysis Working Group (OAWG) initiated CCQM-K95.1 "Low-Polarity Analytes in a Botanical Matrix: Polycyclic Aromatic Hydrocarbons (PAHs) in Tea". This was a follow-on comparison from CCQM-K95 which was completed in 2014.
The polycyclic aromatic hydrocarbons (PAHs) benz[a]anthracene (BaA) and benzo[a]pyrene (BaP) are considered priority pollutants by U.S. Environmental Protection Agency and are regulated contaminants in food, pose chromatographic separation challenges, and for which exist well-characterized measurement procedures and standard materials. BaA and BaP in a smoked tea were therefore selected as representative target measurands for CCQM-K95.1. Ten NMIs participated in CCQM-K95.1. The consensus summary mass fractions for the two PAHs are in the range of (50 to 70) ng/g with relative standard deviations of (6 to 10) %.
Successful participation in CCQM K95.1 demonstrates the following measurement capabilities in determining mass fraction of organic compounds, with molar mass of 100 g/mol to 500 g/mol and having polarity pKow −2, in a botanical matrix ranging in mass fraction from 10 ng/g to 1000 ng/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, (3) extraction of analytes of interest from the matrix, (4) cleanup and separation of analytes of interest from interfering matrix or extract components, and (5) separation and quantification using gas chromatography or liquid chromatography.
Solutions of organic analytes of known mass fraction are typically used to calibrate the measurement processes used to determine these compounds in matrix samples. Appropriate value assignments and uncertainty calculations for calibration solutions are critical for accurate measurements. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2015 the Organic Analysis Working Group (OAWG) sponsored CCQM-K131 "Low-Polarity Analytes in a Multicomponent Organic Solution: Polycyclic Aromatic Hydrocarbons (PAHs) in Acetonitrile".
Polycyclic aromatic hydrocarbons (PAHs) result from combustion sources and are ubiquitous in environmental samples. The PAH congeners, benz[a]anthracene (BaA), benzo[a]pyrene (BaP), and naphthalene (Nap) were selected as the target analytes for CCQM-K131. These targets span the volatility range of PAHs found in environmental samples and include potentially problematic chromatographic separations. Nineteen NMIs participated in CCQM-K131. The consensus summary mass fractions for the three PAHs are in the range of (5 to 25) μg/g with relative standard deviations of (2.5 to 3.5) %.
Successful participation in CCQM-K131 demonstrates the following measurement capabilities in determining mass fraction of organic compounds of moderate to insignificant volatility, molar mass of 100 g/mol up to 500 g/mol, and polarity pKow < −2 in a multicomponent organic solution ranging in mass fraction from 100 ng/g to 100 μg/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, and (3) separation and quantification using gas chromatography or liquid chromatography.
The growing market penetration of heat pumps indicates the need for a performance test method that better reflects the dynamic behavior of heat pumps. In this contribution, we developed and implemented a dynamic test method for the evaluation of the seasonal performance of heat pumps by means of laboratory testing. Current standards force the heat pump control inactive by fixing the compressor speed. In contrast, during dynamic testing, the compressor runs unfixed while the heat pump is subjected to a temperature profile. The profile consists of the different outdoor temperatures of a typical heating season based on the average European climate and also includes temperature changes to reflect the dynamic behavior of the heat pump. The seasonal performance can be directly obtained from the measured heating energy and electricity consumption making subsequent data interpolation and recalculation with correction factors obsolete. The method delivers results with high precision and high reproducibility and could be an appropriate method for a fair rating of heat pumps.
In the light of digitalization and recent EU policy initiatives, information is an important asset that organizations of all sizes and from all sectors should secure. However, in order to provide common requirements for the implementation of an information security management system, the internationally well-accepted ISO/IEC 27001 standard has not shown the expected growth rate since its publication more than a decade ago.In this article, we apply web mining to explore the adoption of ISO/IEC 27001 through a series of 2664 out of more than 900 000 German firms from the Mannheim Enterprise Panel dataset that refers to this standard on their websites. As a result, we present a “landscape” of ISO/IEC 27001 in Germany, which shows that firms not only seek certifications themselves but often refer on their websites to partners who are certified instead. Consequently, we estimate a probit model and find that larger and more innovative firms are more likely to be certified to ISO/IEC 27001 and that almost half of all certified firms belong to the information and communications technology (ICT) service sector. Based on our findings, we derive implications for policymakers and management and critically assess the suitability of web mining to explore the adoption of management system standards.
The Industrial Internet of Things (IIoT) poses multiple challenges to traditional standardization, due to the complexity, dynamics, and accelerating speed of technological progress. The need for a timely availability of standards calls for new approaches and tools to enhance standardization processes for smart manufacturing. Industry and standards development organizations worldwide are seeking new solutions. Testbeds have been acknowledged in innovation policy as a powerful tool for knowledge transfer and the further development of emerging technologies. Lately, they have also attracted increasing attention from the standardization perspective as a promising tool for a more agile standards development process. Proponents of such testbeds expect them to support standardization by providing validated solutions and accelerating the processes to meet the growing demands for faster standardization without any detriment to quality. In an explorative, qualitative approach this article is the first to investigate the operation and impact of testbeds in standardization processes based on a multiple case study on testbeds implemented worldwide in the context of the IIoT.
Accreditation is one of the pillars of a national Quality Infrastructure, as the competence of conformity assessment bodies is assured through accreditation performed by accreditation bodies. To compare the operation of accreditation bodies in Europe and to identify best practices, a management tool, the Process Maturity Benchmarking Tool, was developed and validated by applying it to European accreditation bodies. The benchmarking project comprised two major phases: In the first phase, the processes of accreditation bodies were systematically analyzed. A process map was developed, and processes of special relevance were identified and underpinned by indicators. In the second phase, the practical applicability of the theoretical model was demonstrated by analyzing the processes of eight European accreditation bodies. The results of this comparative assessment were subsequently discussed in a workshop with experts from those accreditation bodies, giving the opportunity to identify best practices.
This article has a twofold objective. First, to present a method to benchmark European accreditation bodies, based on the European Foundation for Quality Management excellence model. The successful application of the Process Maturity Benchmarking Tool gives evidence that it is a suitable and capable management tool to assess the processes of the European accreditation bodies and to benchmark them. Second, the article presents the results of the first adaption of the Process Maturity Benchmarking Tool. A general trend of process maturity was identified: While processes based on stakeholder involvement tend to have an overall lower maturity on average, internal processes are more mature.
Despite the growing dependence of companies on information technology and the increasingly negative impact of security incidents worldwide, there is little research on the management of information security at the company level. This paper seeks to expand knowledge on the implementation of an information security management system based on the widely used international standard ISO/IEC 27001. We present motives, experienced impacts, and obstacles related to ISO/IEC 27001 implementation using data from a survey of 125 ISO/IEC 27001 certified companies in Germany. Since adoption rates vary between ICT and non-ICT sector companies, we highlight sector-related variations. We classify the adoption of this standard as a preventive organizational innovation and apply Structural Equation Modeling to unearth explanations for the comparatively low adoption of this management system standard among companies outside the ICT sector. We, therefore, derive recommendations for policymakers, standardization, and certification bodies to foster its diffusion.
High spatially resolved quantitative bioimaging of CdSe/ZnS Quantum Dots uptake in two kinds of cells is investigated combining laser ablation inductively coupled plasma mass spectrometry and the spatially resolved analysis of dried pL-droplets from a solution with a known concentration of Quantum Dots. Single cells and dried pL-droplets are morphologically characterized by Atomic Force Microscopy. A number concentration of CdSe/ZnS QDs between 3.5 104 and 48 104 is estimated to be uptaken by several selected single cells, after being incubated in the presence of a QDs suspension added to a standard cell culture medium. Mono-elemental bioimaging at subcellular resolution seems to show a higher number concentration of the CdSe/ZnS QDs in the cytosol around the cell nucleus.
Smart Products Enable Smart Regulations—Optimal Durability Requirements Facilitated by the IoT
(2021)
The challenges and opportunities linked with IoT have been intensively discussed in recent years. The connectivity of things over their entire life cycle and the smart properties associated with it provide new functionalities and unprecedented availability of (usage) data. This offers huge opportunities for manufacturers, service providers, users, and also policymakers. The latter May impact policy areas such as the regulations on resource and materials efficiency under the Ecodesign Directive 2009/125/EC. With the general approach as it is practiced today, legal requirements are usually set for entire product groups without considering the products individually, including user behavior and environmental conditions. The increasing number of smart products and the growing availability of product data are sparking a discussion on whether these requirements could be more product and application-specific. This paper presents a method for calculating the economically and ecologically optimal durability of a product. It allows determining the point in time when a product should be replaced by combining consumer data with product design data. This novel Approach could contribute to making product regulation more flexible and possibly more efficient. In this context, fundamental challenges associated with smart products in policymaking are also discussed.
An alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry. For isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions, ranging from 0.06 to 0.99 mol mol–1, previously determined by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS). The calibration ML model was validated with two certified reference materials (LSVEC and IRMM-016). The procedure was applied toward the isotope amount ratio determination of a set of stock chemicals (Li2CO3, LiNO3, LiCl, and LiOH) and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. The results of these determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9 to 6.2‰. This precision was sufficient to resolve naturally occurring variations, as demonstrated for samples ranging from approximately −3 to +15‰. To assess its suitability to technical applications, the NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification. The results obtained were metrologically compatible with each other.
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry.