8.6 Faseroptische Sensorik
Filtern
Dokumenttyp
- Vortrag (86)
- Beitrag zu einem Tagungsband (56)
- Zeitschriftenartikel (55)
- Posterpräsentation (30)
- Buchkapitel (3)
- Forschungsdatensatz (3)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
- Sonstiges (1)
- Forschungsbericht (1)
Sprache
- Englisch (179)
- Deutsch (57)
- Mehrsprachig (1)
Schlagworte
- Distributed acoustic sensing (29)
- Structural health monitoring (28)
- DAS (21)
- Machine learning (18)
- Distributed fiber optic sensing (17)
- Distributed fiber sensing (16)
- Artificial neural networks (14)
- Verteilte faseroptische Sensorik (12)
- Acoustic sensing (11)
- Distributed sensing (11)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (237)
- 8.6 Faseroptische Sensorik (237)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (28)
- 3 Gefahrgutumschließungen; Energiespeicher (26)
- 8.4 Akustische und elektromagnetische Verfahren (20)
- 7 Bauwerkssicherheit (17)
- 2 Prozess- und Anlagensicherheit (16)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (16)
- 7.4 Baustofftechnologie (14)
- 1 Analytische Chemie; Referenzmaterialien (13)
The use of artificial neural networks (ANNs) is demonstrated for efficient real-time data processing in optical fiber sensing applications. Using ANN-based algorithms, two orders of magnitude improved computation time and improved measurement resolution is achieved for distributed strain sensing using the wavelength-scanning coherent optical time domain reflectometry technique.
The distributed measurement of relative humidity is a sought-after capability for a wide range of applications in civil engineering and structural health monitoring. We show that polymethyl methacrylate (PMMA) optical fi-bers can be employed as a sensor medium to conduct distributed humidity measurement by analyzing Rayleigh backscattering traces obtained by OTDR. We make use of the effect that water penetrates the fiber core and directly influences the local fiber attenuation and Rayleigh backscatter coefficient. We conducted distributed backscattering analysis for two different pulse wavelengths: 500 nm and 650 nm. The 650 nm results are susceptible to both, attenuation changes and backscatter changes, whereas backscatter results at 500 nm are not affected by humidity-induced attenuation and only exhibit a change of Rayleigh backscattered power as a function of humidity. The combined measurement and analysis of both parameters at these two wavelengths has the advantage that cross-sensitivities on backscatter change and attenuation, such as strain and tempera-ture changes, could be separated from the humidity response of the fiber. We present laboratory results for a humidity range between 30% and 90% for both pulse wavelengths: including step responses, humidity cycles and hysteresis analysis. In addition to the attenuation and backscatter coefficient dependence, we also analyze optical runtime changes as a function of humidity. POFs have the advantage that they can be directly embed-ded into materials such as concrete or soil to measure water content or localize water ingress. Standard step-index PMMA POFs can be used as a distributed relative humidity sensor up to 200 m distance.
We present our research on the development of a Brillouin optical frequency-domain analysis (BOFDA) using a perfluorinated graded-index polymer optical fiber (PFGI-POF) as a sensing fiber. The described works include investigations both on the selection of the setup components with respect to mode coupling effects and on the impact of the humidity cross-sensitivity. The suitability of the developed POF-based BOFDA is proved by a distributed measurement on an 86 m long PFGI-POF recorded with the spatial resolution of 6 m.
Humidity is one of principal environmental parameters that plays an important role in various application areas. Distributed humidity/water sensing is sought after in wide range of applications including concrete condition monitoring in civil engineering, SHM of large structures such as dykes or dams, soil moisture measurement in agriculture or leak detection in pipeline or sewage industry. Using humidity-induced strain of specialty hygroscopic coating materials, such as polyimide (PI) seems as the most promising approach so far. In this work, relative humidity and temperature response of different commercial PI-coated and tight-buffer fibers is investigated for the development of distributed humidity sensor.
Humidity is one of principal environmental parameters that plays an important role in various application areas. Using measurement of strain induced in an optical fiber by a water swellable coating represents a promising approach for realization of distributed humidity sensing (DHS). In this work, humidity and temperature response of four different commercial PI-coated fibers and four tight-buffered (TB) fibers is investigated with the aim of evaluating their potential for development of DHS in context of water ingress sensor for high-voltage power cable splices. PI-coated fibers exhibited close-to-linear humidity and temperature response. While the temperature response is relatively coating-independent, magnitude of humidity response was broadly correlated to the relative fiber-to-coating thickness ratio. In contrast, both humidity and temperature response of TB fibers is strongly influenced by buffer type, with Leoni TB900L fiber with Hytrel buffer exhibiting largest humidity and temperature sensitivity. While the response of tight-buffered fibers is generally nonlinear, roughly three-times higher humidity response can be achieved with TB900L compared to the most sensitive PI-coated fiber. Using the TB fiber can be, therefore, advantageous for simpler water detection applications, such as one targeted in this study, when larger sensitivity is more important than the linear response of the sensor.
In the present study, the impact of static traffic loading on the slight deflection effects in the concrete structure of an existing bridge has been investigated using distributed fiber optic sensors. In the face of increasing traffic density and severe traffic loading, the results of the load tests on the Amsterdam bridge 705 make an important contribution to the understanding of its structural behavior. The concept of the static loading was based on the use of two 36-ton trucks stopped on the bridge at multiple pre-determined locations. The load applied in this way led to location-dependent small deflection effects recorded as longitudinal strain of the sensing fiber embedded at the underside of the bridge. The measurements were performed with a commercially-available solution based on Tunable Wavelength Coherent Optical Time Domain Reflectometry with the measurement accuracy in the range of 0.5 µm/m.
Pipe integrity is a central concern regarding technical safety, availability, and environmental compliance of industrial plants and pipelines. A condition monitoring system that detects and localizes threats in pipes prior to occurrence of actual structural failure, e.g., leakages, especially needs to target transient events such as impacts on the pipe wall or pressure waves travelling through the medium. In the present work, it is shown that fiber-optic distributed acoustic sensing (DAS) in conjunction with a suitable application geometry of the optical fiber sensor allows to track propagating acoustic waves in the pipeline wall on a fast time-scale. Therefore, short impacts on the pipe may be localized with high fidelity. Moreover, different acoustic modes are identified, and their respective group velocities are in good agreement with theoretical predications. In another set of experiments modeling realistic damage scenarios, we demonstrate that pressure waves following explosions of different gas mixtures in pipes can be observed. Velocities are verified by local piezoelectric pressure transducers. Due to the fully distributed nature of the fiber-optic sensing system, it is possible to record accelerated motions in detail. Therefore, in addition to detection and localization of threatening events for infrastructure monitoring, DAS may provide a powerful tool to study the development of gas explosions in pipes, e.g., investigation of deflagration-to-detonation-transitions (DDT).
In the present study, the impact of static traffic loading on the slight deflection effects in the concrete structure of an existing bridge has been investigated using distributed fiber optic sensors. In the face of increasing traffic density and severe traffic loading, the results of the load tests on the Amsterdam bridge 705 make an important contribution to the understanding of its structural behavior. The concept of the static loading was based on the use of two 36-ton trucks stopped on the bridge at multiple pre-determined locations. The load applied in this way led to location-dependent small deflection effects recorded as longitudinal strain of the sensing fiber embedded at the underside of the bridge. The measurements were performed with a commercially-available solution based on Tunable Wavelength Coherent Optical Time Domain Reflectometry with the measurement accuracy in the range of 0.5 µm/m.
Wavelength-scanning distributed acoustic sensing for structural monitoring and seismic applications
(2019)
We introduce wavelength-scanning coherent optical time domain reflectometry (WS-COTDR) for dynamic vibration sensing along optical fibers. The method is based on spectral shift computation from Rayleigh backscatter spectra. Artificial neural networks (ANNs) are used for fast and high-resolution strain computation from raw measurement data. The applicability of the method is demonstrated for vibration monitoring of a reinforced concrete bridge. We demonstrate another application example for quasi-static and dynamic measurement of ground deformation and surface wave propagation along a dark fiber in a telecommunication cable.
Wavelength-scanning distributed acoustic sensing for structural monitoring and seismic applications
(2019)
We introduce wavelength-scanning coherent optical time domain reflectometry (WS-COTDR) for dynamic vibration sensing along optical fibers. The method is based on spectral shift computation from Rayleigh backscatter spectra. Artificial neural networks (ANNs) are used for fast and high-resolution strain computation from raw measurement data. The applicability of the method is demonstrated for vibration monitoring of a reinforced concrete bridge. We demonstrate another application example for quasi-static and dynamic measurement of ground deformation and surface wave propagation along a dark fiber in a telecommunication cable.
Auf der Grundlage der in DIN EN 61757-2-2:2017 beschriebenen Standardisierungsmethoden wurden in dieser Arbeit wichtige Leistungsparameter von vier kommerziellen Messsystemen zur ortsaufgelösten faseroptischen Erfassung der temperatur- und dehnungsabhängigen Brillouin-Frequenzverschiebung untersucht. Gemäß der oben genannten Norm konzentrierte sich hier die Ermittlungsprüfung auf messtechnische Aspekte reiner Temperaturmessungen. Dabei diente die Ermittlung von einem festgelegten Satz dreier Betriebsverhaltenskenngrößen in Form von quantitativen Angaben des Messfehlers, der Wiederholgenauigkeit sowie der räumlichen Unsicherheit einem Vergleich der getesteten Messsysteme.
Alle faseroptischen Messungen wurden mit einer Faserschleife ausgeführt, d. h. als Sensorkonfiguration der Messfaser wurde eine Schleifenanordnung gewählt. Die Messverfahren der getesteten Messysteme basierten somit auf der Brillouin-optischen Zeit- bzw. Frequenzbereichsanalyse. Die Betriebsverhaltenskenngrößen wurden ferner bei unterschiedlichen Werten zweier messtechnischer Parameter, des Frequenzschrittes und der Mittelungsrate, für Standardeinstellungen der Laserleistungswerte der in die Sensorfaser einzukoppelnden Laserlichtsignale ermittelt. Auf diesem Weg lassen sich relevante Aussagen zur Optimierung der Messgenauigkeiten in Bezug auf Messdauer treffen.
Auf der Grundlage der in DIN EN 61757-2-2:2017 beschriebenen Standardisierungsmethoden wurden in dieser Arbeit wichtige Leistungsparameter von vier kommerziellen Messsystemen zur ortsaufgelösten faseroptischen Erfassung der temperatur- und dehnungsabhängigen Brillouin-Frequenzverschiebung untersucht. Gemäß der oben genannten Norm konzentrierte sich hier die Ermittlungsprüfung auf messtechnische Aspekte reiner Temperaturmessungen. Dabei diente die Ermittlung von einem festgelegten Satz dreier Betriebsverhaltenskenngrößen in Form von quantitativen Angaben des Messfehlers, der Wiederholgenauigkeit sowie der räumlichen Unsicherheit einem Vergleich der getesteten Messsysteme.
Alle faseroptischen Messungen wurden mit einer Faserschleife ausgeführt, d. h. als Sensorkonfiguration der Messfaser wurde eine Schleifenanordnung gewählt. Die Messverfahren der getesteten Messysteme basierten somit auf der Brillouin-optischen Zeit- bzw. Frequenzbereichsanalyse. Die Betriebsverhaltenskenngrößen wurden ferner bei unterschiedlichen Werten zweier messtechnischer Parameter, des Frequenzschrittes und der Mittelungsrate, für Standardeinstellungen der Laserleistungswerte der in die Sensorfaser einzukoppelnden Laserlichtsignale ermittelt. Auf diesem Weg lassen sich relevante Aussagen zur Optimierung der Messgenauigkeiten in Bezug auf Messdauer treffen.
For the purpose of increasing payload and reduce freight cost, lightweight composite tank containers used for Transportation have been progressively developed during the last years. Compared to conventionally produced cylindrical steel tanks, the fiber-reinforced solutions allow greater flexibility in the tank design. Despite a number of further material-related benefits of fiber-reinforced composites as non-conductive and non-magnetic behavior as well as corrosion resistance and high strength, the optimization of their thermal degradation properties during combustion is still a challenge. To improve the fire performance of lightweight composite containers, special intumescent fire protection coatings can be applied onto the outside tank surface. This paper presents fire tests on glass-fiber-reinforced plastic transport tanks with complex geometries sheltered with different surface-applied fire protection systems. To evaluate the fire resistance of the tank structures, a fiber optic monitoring system was developed. This system is based on distributed temperature measurements using high-Resolution optical backscatter reflectometry and pointwise reference measurements using fiber Bragg gratings. Thereby, all the fiber optic sensors were directly integrated in the composite layer structure of the tanks. The focus of the presented work is on the demonstration of capability of fiber optic monitoring system in such high-temperature application. Moreover, the fiber optic measurements provide new insights into the efficiency of intumescent coating applied for fire protection of fiber-reinforced plastic transport tanks.
We demonstrate the use of a 3D printed radial collimator in X-ray powder diffraction and surface sensitive grazing incidence X-ray diffraction. We find a significant improvement in the overall Signal to background ratio of up to 100 and a suppression of more than a factor 3⋅10⁵ for undesirable Bragg reflections generated by the X-ray “transparent” windows of the sample environment.
The background reduction and the removal of the high intensity signals from the windows, which limit the detector’s dynamic range, enable significantly higher sensitivity in experiments within sample environments such as vacuum chambers and gas- or liquid-cells. Details of the additively manufactured steel collimator geometry, alignment strategies using X-ray fluorescence, and data analysis are also briefly discussed. The flexibility and affordability of 3D prints enable designs optimized for specific detectors and sample environments, without compromising the degrees of freedom of the diffractometer.
Smart geosynthetics with embedded optical fibers as distributed sensors provide solutions both for applications in geotechnical engineering and for cost-effective monitoring of critical infrastructures. The incorporation of glass or polymer optical fibers (GOFs or POFs) in geotextiles and geogrids allows early detection of mechanical deformations, temperature and humidity. This paper presents selected examples of smart geosynthetics based on Brillouin and Rayleigh scattering effects in incorporated fiber optic sensors for monitoring of large geotechnical structures like dikes, dams, railways, embankments or slopes. The focus of the presented work is on real field tests of measurement capability with respect to the chosen measurement principle and used fiber type.
Kurzfassung. Die meisten Faserverbundbehälter, die in Europa für den Transport gefährlicher Stoffe oder als Speicherbehälter für Wasserstoff oder Erdgas in Fahrzeugen Verwendung finden, werden für eine nicht begrenzte Lebensdauer ausgelegt. In regelmäßigen Abständen sind für diese Druckbehälter wiederkehrende Prüfungen vorgeschrieben, die in der Regel aus visuellen Inspektionen und hydraulischen Innendruckprüfungen bestehen [1]. Die wiederkehrenden Prüfungen sind jedoch weder geeignet, die sichere Betriebsdauer festzulegen noch den Alterungszustand der Druckbehälter zu beurteilen. Aufgrund des weiter steigenden Drucks zur Kosten- und Gewichtsreduktion von Faserverbundbehältern und der damit einhergehenden Ausnutzung der existierenden Sicherheitsmargen gewinnen Methoden zur Beurteilung des Alterungsverhaltens dieser Druckbehälter immer mehr an Bedeutung.
Vor diesem Hintergrund wurde in der BAM das orhaben „Alterungsverhalten von Composite-Druckgefäßen mit Carbonfaser-Compositen unter gekoppelten Beanspruchungen (COD-AGE)“ gestartet, um die Alterung von Faserverbundbehältern mittels verschiedener zerstörungsfreier Prüfverfahren zu untersuchen. Die hier vorgestellten Ergebnisse wurden an einem Typ 4 Hybridbehälter mit Kunststoffliner gewonnen, in den im Rahmen des Herstellungsprozesses optische Glasfasern in verschiedenen Schichten integriert wurden. Der Behälter wurde mittels hydraulischem Innendruck und erhöhter Umgebungstemperatur zyklisch bis zum Lebensende belastet. Zwischen den einzelnen Lastsequenzen erfolgte eine an die wiederkehrende Prüfung im Betrieb angelehnte hydraulische Druckbelastung.
Sowohl die hydraulische Alterung als auch die Druckrampen wurden mittels Schallemissionsprüfung (SEP) und verteilter faseroptischer Sensorik mit dem Ziel einer frühzeitigen Versagensvorhersage überwacht. Durch die Schallemissionsanalyse sollte untersucht werden, ob zum Lebensende hin ein signifikanter Anstieg der Schallemissionsaktivität und -intensität, unterteilt in verschiedene Lastbereiche, beobachtet werden kann. Zusätzlich zum kontinuierlichen Monitoring der Zyklierung sollten die Druckrampen separat untersucht werden, um hier Potenziale für die wiederkehrende Prüfung zu erkennen.
We present the results of distributed fibre optic strain sensing for condition monitoring of a hybrid type IV composite fully wrapped pressure vessel using multilayer integrated optical fibres. During load cycle tests material fatigue could be localised and monitored 17,000 load cycles before burst. Results have been validated by acoustic emission analysis.
Kurzfassung. Die meisten Faserverbundbehälter, die in Europa für den Transport gefährlicher Stoffe oder als Speicherbehälter für Wasserstoff oder Erdgas in Fahrzeugen Verwendung finden, werden für eine nicht begrenzte Lebensdauer ausgelegt. In regelmäßigen Abständen sind für diese Druckbehälter wiederkehrende Prüfungen vorgeschrieben, die in der Regel aus visuellen Inspektionen und hydraulischen Innendruckprüfungen bestehen. Die wiederkehrenden Prüfungen sind jedoch weder geeignet, die sichere Betriebsdauer festzulegen noch den Alterungszustand der Druckbehälter zu beurteilen. Aufgrund des weiter steigenden Drucks zur Kosten- und Gewichtsreduktion von Faserverbundbehältern und der damit einhergehenden Ausnutzung der existierenden Sicherheitsmargen gewinnen Methoden zur Beurteilung des Alterungsverhaltens dieser Druckbehälter immer mehr an Bedeutung.
Vor diesem Hintergrund wurde in der BAM das Vorhaben „Alterungsverhalten von Composite-Druckgefäßen mit Carbonfaser-Compositen unter gekoppelten Beanspruchungen (COD-AGE)“ gestartet, um die Alterung von Faserverbundbehältern mittels verschiedener zerstörungsfreier Prüfverfahren zu untersuchen. Die hier vorgestellten Ergebnisse wurden an einem Typ 4 Hybridbehälter mit Kunststoffliner gewonnen, in den im Rahmen des Herstellungsprozesses optische Glasfasern in verschiedenen Schichten integriert wurden. Der Behälter wurde mittels hydraulischem Innendruck und erhöhter Umgebungstemperatur zyklisch bis zum Lebensende belastet. Zwischen den einzelnen Lastsequenzen erfolgte eine an die wiederkehrende Prüfung im Betrieb angelehnte hydraulische Druckbelastung.
Sowohl die hydraulische Alterung als auch die Druckrampen wurden mittels Schallemissionsprüfung (SEP) und verteilter faseroptischer Sensorik mit dem Ziel einer frühzeitigen Versagensvorhersage überwacht. Durch die Schallemissionsanalyse sollte untersucht werden, ob zum Lebensende hin ein signifikanter Anstieg der Schallemissionsaktivität und -intensität, unterteilt in verschiedene Lastbereiche, beobachtet werden kann. Zusätzlich zum kontinuierlichen Monitoring der Zyklierung sollten die Druckrampen separat untersucht werden, um hier Potenziale für die wiederkehrende Prüfung zu erkennen.
We compare four different sensing solutions suitable for distributed fiber optic humidity sensing in per uorinated graded-index polymer optical fibers (PFGI-POFs). Compared to silica fbers, polymer optical fibers over advantageous beneffits including signifficantly higher break down strain, fracture toughness and humidity sensitivity. Various humidity-related effects in PFGI-POFs have been reported in the last years including measured attenuation and length changes as well as Brillouin frequency and Bragg wavelength shifts. The four aforementioned methods could serve as a basis for distributed and quasi-distributed humidity sensing and are described here closely with an emphasis on plausible cross effects to temperature and strain. The main focus of this paper lies on the comparison of four approaches with regard to method complexity, sensitivity to humidity, spatial resolution, real-time capability and effort to compensate for cross effects.
The application of composite pressure vessels is of great interest due to tremendous weight saving. Nevertheless, ageing of CFRP (carbon fiber reinforced plastic) composites pressure vessels underlies complex interactions between metallic liner and composite and is not fully understood yet. One main challenge is the application of appropriate testing methods for detecting the influences of pressure cycles and creep behavior on the material. This contribution presents results achieved by using conventional eddy current testing (ET) and high frequency ET. Here, we could show that also conventional ET with low frequencies are useable to investigate pressure vessels of different material combinations like aluminum-CFRP and synthetics-CFRP.
Fibreoptic sensors (FOS) represent sensing technology with small footprint, low invasiveness, electromagnetic passivity and immunity, plus potential for remote and real-time monitoring. Modern FOS techniques allow truly temporally- and spatially-continuous monitoring over extended distances; a feature not attainable with any other sensing technology. Moreover, depending on their particular material composition and design, optical fibres can be made resistant to high temperatures, chemicals and ionizing radiation. Due to this unique combination of advantageous properties, ever since their emergence, FOS have been attracting considerable attention for monitoring tasks in harsh, hazardous and difficult-to-access locations. The potential of FOS has been recognized also in the field of radioactive waste management and fibreoptic sensors belong to the most promising technologies for nuclear waste repositories (NWR) monitoring.
Vast majority of distributed fibreoptic sensor applications rely on use of silica-based optical fibres as sensing elements. At the same time, distributed measurement of local temperature and strain along the fibre are the most common monitoring tasks addressed by fibreoptic sensors. Nevertheless, FOS offer much larger flexibility both in terms of utilized sensing fibre as well as targeted measurand. In this contribution, we will review some of more alternative implementations of FOS that are being explored at “Fibre Optic Sensors” division of Federal Institute for Material Research and Testing (BAM), in Berlin. The main focus will be twofold. On one side, we will address FOS applications with polymer optical fibres (POF), that may enable monitoring of large strains (>100%) and high-sensitivity radiation detection. On the other side, we will present our activities in the area of distributed acoustic sensing (DAS); one of the most recent developments in the fibreoptic sensing field enabling highly-dynamic vibration sensing with nanostrain sensitivity. We will introduce the principles of the addressed FOS technologies, present application examples from our case studies, discuss advantages and limitations of the techniques and highlight their potential for NWR monitoring.
The proposed BAM project SealWasteSafe will advance the state of the art for the construction and monitoring of safe sealing systems for underground repositories of radioactive or toxic waste. During this project, a novel salt concrete exhibiting neither significant cracking nor shrinkage will be optimized for use in the sealing systems. The composition of this material will be based on alkali-activated materials, which are characterized by particularly small thermal deformations during the hardening reaction. Quality assurance and continuous monitoring systems developed during this project will be demonstrated not only for high reliability, but also for resistance to highly alkaline environments and to water intrusion along cables or at sensor locations. A variety of sensors will be used in combination with wireless Radio Frequency Identification (RFID) technology to record moisture, temperature, and, if necessary, corrosion activity within the sealing system. Distributed Fibre Optic Sensor (FOS) technology will also be used for strain, temperature, and moisture content measurement. Ultrasound-based measuring methods will be utilized for the detection of cracks and delaminations. Additionally, digital image correlation and acoustic emission analysis will be used for deformation measurements and crack detection. A novel borehole probe and advanced ultrasound imaging techniques will be further developed to track cracks and delaminations within the host rock in 3D. The surface-based Large Aperture Ultrasound System (LAUS) will also be utilized to detect cracks and delaminations deep below the exterior surface of the sealing system. Although the focus of this project will be on the host rock salt, the resulting technologies will be intentionally developed in a way that facilitates their adaptation to other host rocks.
We compare four different sensing solutions suitable for distributed fiber optic humidity sensing in per uorinated graded-index polymer optical fibers (PFGI-POFs). Compared to silica fbers, polymer optical fibers over advantageous beneffits including signifficantly higher break down strain, fracture toughness and humidity sensitivity. Various humidity-related effects in PFGI-POFs have been reported in the last years including measured attenuation and length changes as well as Brillouin frequency and Bragg wavelength shifts. The four aforementioned methods could serve as a basis for distributed and quasi-distributed humidity sensing and are described here closely with an emphasis on plausible cross effects to temperature and strain. The main focus of this paper lies on the comparison of four approaches with regard to method complexity, sensitivity to humidity, spatial resolution, real-time capability and effort to compensate for cross effects.
The in-situ monitoring of electrochemical deposition (ECD) processes is still a challenge regarding the measurement of the effective temperature of the substrate and the formation of mechanical stress in the layer under given plating conditions. Monitoring problems can be solved by applying a pre-coated fiber Bragg grating (FBG) to the electrolytic process as the shift of the Bragg wavelength is affected by both the temperature of the electrolyte near the substrate and the stress formation in the growing layer. The experimental FBG set-up and the quantitative determination of temperature- and stress-related strain is described for a nickel-iron electrolyte.
We present, to our knowledge for the first time, a 100-km Brillouin Optical Frequency-Domain Analysis (BOFDA) employing a 200-km fiber loop. Compared to our previous publication, enhanced sensor length, sensor accuracy and spatial resolution are presented. The performance improvements are achieved by applying distributed Raman amplification (DRA) and a digital high-pass filter. We report on temperature measurements over sensing distances of 75 km and 100 km both with a 12.5-m spatial resolution. Temperature changes of 5 °C have been measured along 75 km sensing fiber. A temperature change of 30 °C has been detected at 99.5 km.
We propose to use artificial neural networks (ANNs) for raw measurement data interpolation and signal shift computation and to demonstrate advantages for wavelength-scanning coherent optical time domain reflectometry (WS-COTDR) and dynamic strain distribution measurement along optical fibers. The ANNs are trained with synthetic data to predict signal shifts from wavelength scans. Domain adaptation to measurement data is achieved, and standard correlation algorithms are outperformed. First and foremost, the ANN reduces the data analysis time by more than two orders of magnitude, making it possible for the first time to predict strain in real-time applications using the WS-COTDR approach. Further, strain noise and linearity of the sensor response are improved, resulting in more accurate measurements. ANNs also perform better for low signal-to-noise measurement data, for a reduced length of correlation input (i.e., extended distance range), and for coarser sampling settings (i.e., extended strain scanning range). The general applicability is demonstrated for distributed measurement of ground movement along a dark fiber in a telecom cable. The presented ANN-based techniques can be employed to improve the performance of a wide range of correlation or interpolation problems in fiber sensing data analysis and beyond.
Die Erforschung des Potenzials faseroptischer Sensorsysteme (FOS) für qualitäts- und verfügbarkeitssteigernde Anwendungen im Bahnbereich führt seit einigen Jahren international zu vielversprechenden Erkenntnissen und einer zunehmenden Dynamik im Herstellermarkt. Die Verfügbarkeit quasi wartungsfreier Lichtwellenleiter (LWL) bieten ökonomisch günstige Rahmenbedingungen.
Daneben bestehen herausfordernde Entwicklungsaufgaben aus den Bereichen FOS, Akustik und Signalverarbeitung. Potenzial und Entwicklungsschwerpunkte werden im Folgenden diskutiert.
Fiber reinforced polymers (FRPs) are a well established material in lightweight applications, e.g. in automotive, aerospace or wind energy. The FRP components are subjected to multiaxial mechanical as well as hygrothermal loads. Common operation temperatures are in the range of 213 K and 373 K (-60 °C and 100 °C) at a relative humidity of 10% to 90%. In spacecraft applications, the environmental conditions are even more extreme. However, the correlation between multiaxial mechanical loading and harsh environment conditions have to-date not been investigated in detail. The project aims to investigate the fatigue behavior of FRPs dependent on multiaxial mechanical loading, temperature, and humidity. Extensive experimental testing is performed on flat plate and cylindrical tube specimens, accompanied by numerical and analytical calculations.
Im Vortrag wird das im Themenfeldprojekt AGIFAMOR eingesetzte verteilte faseroptische Messverfahren DAS (distributed acoustic sensing) vorgestellt, und die im Projekt erzielten Ergebnisse am unbeschädigten Rohr werden vorgestellt. Dazu gehören die Optimierung der Sensorapplikation sowie die Beobachtung von Schallwellen im Rohrmantel und von sich im Rohr ausbreitenden Druckwellen.
Es wird ein Überblick über die Technik der faseroptischen Sensorik zur Zustandsüberwachung von Rohrleitungen gegeben. Im ersten Teil des Vortrages werden einige Verfahren der verteilten faseroptischen Sensorik, insbesondere die akustische verteilte faseroptische Sensorik, sowie der Stand der Technik in Bezug auf die Rohrleitungsüberwachung vorgestellt. Anschließend werden im zweiten Teil die Hauptergebnisse des Themenfeldprojektes AGIFAMOR zusammengefasst und in Hinblick auf weiterführende Untersuchungen diskutiert.
Darstellung des Verbundvorhabens "Monalisa" und der im Rahmen des Projekts erzielten F&E-Fortschritte auf dem 2. Statusseminar "Zukunftsfähige Stromnetze" des PTJ zur gleichnamigen Forschungsinitative der Bundesregierung. Präsentiert werden Fortschungsergebnisse zum Thema Zustandsüberwachung von verschiedenen elektrischen Betriebsmitteln (Kabel, Garnituren, Schaltanlagen, Schalter) mittels faseroptischer Sensorik. Das Monitoring bezieht sich dabei auf Temperatur, Vibrationen, eindringende Feuchte, Dehnung, und die Detektion von Teilentladungen
Selbstdarstellung des Verbundvorhabens "Monalisa" auf der Konferenz "VDE Hochspannungstechnik" 2018 der entsprechenden Forschungsinitiative der Bundesregierung Kurzzusammenfassung der Teilprojekte und F&E-Ziele aller beteiligten Partnerinstitutionen (BAM,TU Berlin, HTW Berlin, BeuthHS Berlin, IPH GmbH) zum Bereich Monitoring von elektrischen Betriebsmitteln mit Hilfe von faseroptischer Sensorik.
Verteilte faseroptische Sensorik eignet sich sehr gut für eine Zustands- und Gefährdungsüberwachung von ausgedehnten Hochspannungskabelinstallationen. Basierend auf der Messung von verschiedenen faseroptischen Rückstreueffekten in der Sensorfaser lassen sich ortsaufgelöste Profile von Messgrößen wie Temperatur, Dehnung oder Vibrationen erzielen.
Hier demonstrieren wir die Leistungsfähigkeit verschiedener faseroptischer Sensorikansätze bezüglich dieser Größen anhand von Experimenten u.a. an einem Mittelspannungskabel. Des Weiteren zeigen wir, wie die Verwendung von verschiedenen Sensorkabeltypen mit unterschiedlicher Applikation auf der Kabeloberfläche die Messergebnisse bei einem Biegeversuch beeinflussen und schlussfolgern damit auf die für die Einbettung in Kabeln geeigneten Sensoren.
Es wurde ein Messaufbau realisiert, der die Betriebsedingungen von hydraulisch- pneumatischen Gasdruckkabelsystemen nachbildet und in dieser Veröffentlichung vorgestellt. Mit seiner Hilfe können im Labor diagnostische Messungen und beschleunigte Alterung der Isolierung bei variablen Temperaturen, Druckstufen, Spannungen und Frequenzen durchgeführt werden. Zur Temperatureinstellung wurde im Messaufbau eine Kurzschlussschleife verwendet, die stabile Heizströme über 700 A bei 50 Hz ermöglicht. Der Prüfspannungsbereich während der Verlustfaktor- und Teilentladungsmessungen lag zwischen 1 kV bis 25 kV mit einem Frequenzbereich zwischen 0,1 Hz bis 60 Hz. Um die örtliche und zeitlich lastabhängige Temperatur entlang des Messbelags bestimmen zu können, wurde eine optische Faser (Loose tube) um den Prüfling gewickelt, so dass eine ortsaufgelöste Temperaturermittlung über den Prüflingsmantel erreicht wurde. Aus den erhaltenen Temperaturmessdaten wurde ein einphasiges, planares thermisches Modell erzeugt, das das thermische Verhalten des Prüflings in Abhängigkeit von Laststrom, Raumtemperatur und Materialdaten nachbildet. Dieses wurde mit den aufgenommenen Messdaten verglichen. Aus den Erkenntnissen des einphasigen thermischen Modells soll ein dreiphasiges Modell entstehen, mit dessen Hilfe die Diagnosetemperatur und das Abkühlverhalten von erdverlegten Gasdruckkabeln abgeschätzt werden können. Dadurch kann zukünftig der Temperatureinflusses bei der Interpretation von Vor-Ort-Messungen hinzugezogen werden.
Verteilte faseroptische Sensorik eignet sich sehr gut für eine Zustands- und Gefährdungsüberwachung von ausgedehnten Hochspannungskabelinstallationen. Basierend auf der Messung von verschiedenen faseroptischen Rückstreueffekten in der Sensorfaser lassen sich ortsaufgelöste Profile von Messgrößen wie Temperatur, Dehnung oder Vibrationen erzielen.
Hier demonstrieren wir die Leistungsfähigkeit verschiedener faseroptischer Sensorikansätze bezüglich dieser Größen anhand von Experimenten u.a. an einem Mittelspannungskabel. Des Weiteren zeigen wir, wie die Verwendung von verschiedenen Sensorkabeltypen mit unterschiedlicher Applikation auf der Kabeloberfläche die Messergebnisse bei einem Biegeversuch beeinflussen und schlussfolgern damit auf die für die Einbettung in Kabeln geeigneten Sensoren.
In this paper perfluorinated graded-index polymer optical fibers are characterized with respect to the influence of relative humidity changes on spectral transmission absorption and Rayleigh backscattering. The hygroscopic and thermal expansion coefficient of the fiber are determined to be CHE = (7.4 +/- 0.1) 10^-6 %r.h.^-1 and CTE = (22.7 +/- 0.3) 10^-6 K^-1, respectively. The influence of humidity on the Brillouin backscattering power and linewidth are presented for the first time to our knowledge. The Brillouin backscattering power at a pump wavelength of 1319 nm is affected by temperature and humidity. The Brillouin linewidth is observed to be a function of temperature but not of humidity. The strain coefficient of the BFS is determined to be CS = (146.5 +/- 0.9) MHz/% for a wavelength of 1319 nm within a strain range from 0.1 % to 1.5 %. The obtained results demonstrate that the humidity-induced Brillouin frequency shift is predominantly caused by the swelling of the fiber over-cladding that leads to fiber straining.
The feasibility study „AGIFAMOR. Ageing infrastructures – distributed acoustic monitoring of pipes” is an interdisciplinary research project at BAM internally financed from 2015 to 2018. Therefore, the quite young fibre optic sensing technology of distributed acoustic sensing (DAS) was investigated to possibly be extended towards a global condition monitoring system for pipelines operating in real time.
DAS is a highly dynamic fibre optic sensing technology based on the method of coherent optical time domain reflectometry (C-OTDR). DAS allows capturing strain changes in the range of kHz. For the experimental work, the most suitable application yielding an optimum sensitivity was proven by wrapping a standard single-mode silica fibre around the pipe.
The DAS sensitivity was investigated regarding the detection of 1) incidents that initiate propagation of acoustic waves in the pipe wall, 2) changes inside the pipeline causing altered flow and 3) damage development in the pipe wall. Therefore, several testing setups in laboratory as well as in real scale were realized. For comparison purposes, experiments were accompanied by acoustic emission analyses and by measurements with accelerometers.
DAS was found to be very sensitive to gas ignition and its propagation across the pipe. Furthermore, the ability of DAS to detect and localize acoustic signals associated with pipeline leakage was demonstrated. The detection of crack formation and propagation within the pipe wall by means of DAS was studied during bending tests on several pipe segments, but was not proven so far with certainty. As expected, these studies turned out as the most difficult challenge due to the random occurrence and transient nature of microscopic damage phenomena.
The mechanical stress-strain behaviour of polymer optical fibres (POFs) drawn from various materials was measured, both before and after temperature annealing of the POFs. The POFs were drawn from PMMA (GEHR), Zeonex (480R), PC (Makrolon LED2245) and two different grades of Topas (8007S-04 and 5013S-04). With fibre drawing stresses at or above the elastic (uniaxial extensional) plateau modulus, the polymer chains in the POFs have a high degree of alignment, which has a large impact on fibre mechanical behaviour. The testing was performed at straining rates ranging from 0.011%/s, to 1.1%/s for the un-annealed fibres and a straining rate of 1.1%/s for the annealed ones. The elastic modulus of the tested POFs showed no sensitivity toward variation of straining rate. In the case of Topas 5013S-04 and PMMA, the producer-reported values are the same as the one obtained here for the POFs both before and after annealing. The drawn POFs made of Zeonex, PC, and Topas 8007S-04 exhibit larger elastic modulus than the respective materials in the bulk form. The elastic modulus of these fibres is reduced upon annealing by 10-15%, but still remains above the producer-reported values for the bulk polymers. In the nonlinear elastic region, only the PC POF is statistically unaffected by the changes in the straining rate, while Topas 8007S-04 POF shows insensitivity to the straining rate until 3% strain. All other changes affect the stress-strain curves. The annealing flattens all stress-strain curves, making the fibres more sensitive to yield.
In this work, two novel donor/acceptor (D/A) complexes, namely, diindenoperylene (DIP)/1,3,4,5,7,8-hexafluoro-tetracyanonaphthoquinodimethane (F6TCNNQ) and alpha-sexithiophene (6T)/F6TCNNQ, are studied. The D/A complexes segregate in form of π−π stacked D/A cocrystals and can be observed by X-ray scattering. The different conformational degrees of freedom of the donor molecules, respectively, seem to affect the thin-film crystalline texture and composition of the D/A mixtures significantly. In equimolar mixtures, for DIP/F6TCNNQ, the crystallites are mostly uniaxially oriented and homogeneous, whereas for 6T/F6TCNNQ, a mostly 3D (isotropic) orientation of the crystallites and coexistence of domains of pristine compounds and D/A complex, respectively, are observed. Using optical absorption spectroscopy, we observe for each of the two mixed systems a set of new, strong transitions located in the near-IR range below the gap of the pristine compounds: such transitions are related to charge-transfer (CT) interactions between donor and acceptor. The optical anisotropy of domains of the D/A complexes with associated new electronic states is studied by ellipsometry. We infer that the
CT-related transition dipole moment is perpendicular to the respective π-conjugated planes in the D/A complex.
We present a combined experimental and theoretical study to solve the unit-cell and molecular arrangement of the tetracene thin film (TF) phase. TF phases, also known as substrate induced phases (SIP), are polymorphs that exist at interfaces and decisively impact the functionality of organic thin films, e.g., in a transistor channel, but also change the optical spectra due to the different molecular packing. As SIPs only exist in textured ultrathin films, their structure determination remains challenging compared to bulk materials. Here, we use grazing incidence Xray diffraction and atomistic simulations to extract the TF unit-cell parameters of tetracene together with the atomic positions within the unit-cell.
Die durchleuchtete Brücke
(2018)