Protection against terroristic or accidental scenarios in industrial settings requires suitable designs of structures to resist blast loads. Field testing as well as finite element simulations are among the techniques available to engineers in the understanding of the structural behavior against blast loading.
As blast testing of complex scenarios can be very resource intensive, tests are generally performed for simplified scenarios. Numerical tools can be used to model these scenarios to get better insight into blast loading, structural response, and the resulting damage to the structure. During the next steps, the simplified scenario is successively modified in numerical simulations to incorporate complexities that cannot be covered in blast testing experiments. One of the conditions for this approach to work is that the original simplified numerical simulation is valid. The scopes and challenges encountered in such a validation are the focus of this presentation/article.
A relatively ‘simple’ field test of a horizontal reinforced concrete (RC) slab subjected to blast loading is taken as an example for validation of the performance of numerical tools. The blast test incorporated various measurement techniques to quantify the blast load as well as the behavior of the RC slab. Blast load was measured using flush mounted piezoelectric pressure gauges, whereas acceleration sensors and fiber-optic sensor cables were used to characterize the dynamic behavior of the slab under blast loading. Additionally, damage characteristics were ascertained also using fiber optic sensing. The application of such measurement techniques, along with different numerical software available for the analysis of the scenario in question, demonstrate the scope of our contribution.
When it comes to the challenges, it begins with proper instrumentation of the test specimen followed by the data processing. For numerical modelling, geometric conditions with appropriate boundary constraints, physical conditions such as the configuration of the rebars, as well as material parameters add to this challenge. The issues of choosing appropriate material models and comparison of results with multiple software tools will be discussed. This discussion forms the basis for a coherent approach to technical-safety assessment of blast effects on structures in its broader sense.
Die Nutzung von Sensortechnologien, insbesondere im Bereich der Gasdetektion mit einem Schwerpunkt auf Wasserstoff, spielt eine entscheidende Rolle in verschiedenen Anwendungsbereichen der Wasserstofftechnologie. Sicherheitsüberwachung, Leckdetektion und Prozesskontrolle gehören zu den prominenten Anwendungsgebieten dieser Sensortechnologien. Ein zentrales Ziel ist die Erkennung von freigesetztem Wasserstoff sowie die genaue Bestimmung des Wasserstoff-Luftverhältnisses mithilfe von Gassensoren. Dies ist von entscheidender Bedeutung, um potenzielle Gefahren frühzeitig zu erkennen und angemessene Maßnahmen zu ergreifen.
Ein weiterer Schwerpunkt dieses Beitrags liegt auf der Analytik und der Verwendung zertifizierter Referenzmaterialien in Verbindung mit Metrologie für die Wasserstoffspeicherung. Dies gewährleistet eine präzise und zuverlässige Charakterisierung von Wasserstoff und unterstützt die Entwicklung sicherer Speichertechnologien. Im Rahmen des Euramet-Vorhabens Metrology for Advanced Hydrogen Storage Solutions (MefHySto) wird eine Kurzvorstellung präsentiert.
Der Vortrag stellt zwei zerstörungsfreie Prüfverfahren zum strukturellen Zustandsüberwachung (Structural Health Monitoring, SHM) für Wasserstofftechnologien vor. Insbesondere die Fehlstellenerkennung mittels geführter Ultraschallwellen spielt eine bedeutende Rolle bei der Lebensdauerüberwachung von Wasserstoffspeichern. Ein weiterer Aspekt ist die Anwendung faseroptischer Sensorik zur Schadensfrüherkennung von Wasserstoffspeichern. Diese zerstörungsfreien Prüfverfahren ermöglichen eine präzise und frühzeitige Identifizierung von Schäden, was die Sicherheit und Effizienz von Wasserstoffspeichersystemen entscheidend verbessert.
A safety or security related assessment of explosions, accidental and intentional scenarios alike, often necessitate performance of replication-tests. Such test results are necessary to clarify the causes within the scope of forensic investigations. To gain important insights into the behavior of structures and materials under such loading, field tests may also be performed in accordance with different test standards. To determine the resistance of building-structures after explosions, estimation of the residual load-bearing capacity in addition to the assessment of dynamic structural response and damage to the building components is important. In most cases an evaluation of structural integrity is based only on the visual damage, resulting in an overestimation of the residual capacity.
The Bundesanstalt für Materialforschung und -prüfung (BAM) operates the Test site for Technical Safety (TTS) on an area measuring about 12 km2 in the Federal State of Brandenburg for execution of true-to-scale explosion tests. At the TTS, building component testing was performed to assess the suitability of different non-destructive testing methods to characterize the dynamic structural response and damage resulting from the detonation of high explosives.
Different blast-loading scenarios were realized by varying the net explosive mass and the standoff distance with all scenarios representing a near-field detonation. The test object was a reinforced concrete wall 2 m high, 2.5 m wide and 20 cm thick, fixed at both vertical edges. The dynamic loading of the wall was characterized with 8 piezoelectric pressure sensors flush-mounted on the front surface, thus measuring the reflected pressures from the shock wave. The tests were conducted with the aim of characterizing the global behavior of the wall under dynamic shock loading and the resulting local damage pattern, respectively. High speed digital image correlation was implemented in combination with multiple acceleration sensors to observe the rear surface of the wall to chart the dynamic deflection during the loading and to determine the residual deformation after the loading had ceased. In addition, one test specimen was instrumented with fiber optic sensor cables, both fixed to the rebars and embedded in the concrete-matrix, respectively. Firstly, these sensors were interrogated during the blast test by a distributed acoustic sensing (DAS) device using a particularly high sampling rate to measure the shock-induced vibrations in the structure with high temporal resolution. This delivers information on dynamics of compression and tension cycles from within the structure. Secondly, the local damage-pattern emerging during the series of blasts was determined via distributed fiber optic strain sensing (DSS) by interrogating the embedded fiber optic sensors with a high spatial resolution DSS device after each blast. This enabled the characterization of non-visual damage to the structure, in particular with regard to the formation of localized cracks in the concrete matrix. The DSS was further complimented by a structure-scanner based on ultrasonic measurements.
Our contribution describes this new test approach in detail. Results of the three datasets, namely dynamic shock loading, global behavior of the test object and the local damage pattern will be presented. The suitability of the implemented measurement methods will be discussed in combination with the challenges in their application for technical safety evaluation of building components under explosive loading.
We present a prototype of a distributed POF sensing system for strain detection in road construction and civil engineering ready to be used in practical applications. The system is based on a cost-efficient digital incoherent optical frequency domain reflectometry (I-OFDR). In this approach, the strain-induced changes in the Rayleigh backscattering profile along a perfluorinated polymer optical fiber (PF-POF) are determined by measuring the complex transfer function of the sensing fiber using a compact digital data acquisition unit. The digital unit replaces an oversized vector network analyzer (VNA) enabling suitability of the measurement system for out-door use and providing a significant reduction of the total system costs at the same time. The entire sensor con-cept includes the use of geosynthetics with integrated PF-POFs as two-dimensional sensor structures for geotech-nical applications. The robustness and the functionality of the distributed POF I-OFDR sensors were proven in the field. The field test involved embedding of two geomats, each with two polymer optical sensor loops, into the embankment of the federal road B 91 in a section near Leipzig. The measurements conducted after the sensor-based geomats had been installed confirmed both the potential of such smart geosynthetics and the functionali-ty of the digital I-OFDR prototype.
While hydrogen is one of the most promising energy carriers, the safety of hydrogen storage technology remains one of the most important factors for technological and societal approval. While the engineering safety factors of the pressure vessels are kept high, the periodic inspection and the limited lifetime are making the application very costly considering manpower, time, money, and material waste. The development of an integrated structural health monitoring system can allow an easy transition from the current situation to cost-effective predictive maintenance. Hence, we propose to integrate three different SHM systems into hydrogen pressure vessels, namely guided wave ultrasonics, acoustic emission, and fibre optic sensing, to continuously monitor the condition and integrity.
In this work, we evaluated the condition of a Type IV composite overwrapped pressure vessel using ultrasonic guided wave propagation. We mounted fifteen piezo-electric wafers on the composite cylinder by shaping three rings containing five sensors each. We acquired data from the sensor network following different boundary conditions with artificial damages on the selected locations. The data were evaluated with guided wave tomography techniques using ultrasonic features (amplitude, frequency, etc.) as well as artificial intelligence (AI). The results suggest that both traditional guided wave fusion techniques and AI-based characterization methods can detect artificial damages. In future work, it is planned to integrate acoustic emission and fibre optic sensing. Moreover, the measurement and the test results will be implemented into a digital twin to derive trends and make predictions on the damage propagation as well as the remaining useful lifetime.
This work has received funding from German Ministry of Economic Affairs and Climate Actions within the QI-Digital initiative (www.qi-digital.de).