8.5 Röntgenbildgebung
Filtern
Erscheinungsjahr
- 2023 (80) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (33)
- Vortrag (27)
- Posterpräsentation (13)
- Beitrag zu einem Tagungsband (6)
- Buchkapitel (1)
Schlagworte
- Additive manufacturing (18)
- X-ray computed tomography (13)
- Residual stress (12)
- Microstructure (7)
- Additive Manufacturing (5)
- Simulation (5)
- Computed tomography (4)
- Laser powder bed fusion (4)
- Röntgen-Refraktion (4)
- Synthetic Training Data (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (80)
- 8.5 Röntgenbildgebung (80)
- 9 Komponentensicherheit (11)
- 5 Werkstofftechnik (10)
- 8.0 Abteilungsleitung und andere (7)
- 9.4 Integrität von Schweißverbindungen (7)
- 3 Gefahrgutumschließungen; Energiespeicher (5)
- 5.1 Mikrostruktur Design und Degradation (5)
- 9.6 Additive Fertigung metallischer Komponenten (5)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (4)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (27)
It is shown that preconditioning of experimental X‐ray computed tomography (XCT) data is critical to achieve high‐precision segmentation scores. The challenging experimental XCT datasets and deep convolutional neural networks (DCNNs) are used that are trained with low‐resemblance synthetic XCT data. The material used is a 6‐phase Al–Si metal matrix composite‐reinforced with ceramic fibers and particles. To achieve generalization, in our past studies, specific data augmentation techniques were proposed for the synthetic XCT training data. In addition, two toolsets are devised: (1) special 3D DCNN architecture (3D Triple_UNet), slicing the experimental XCT data from multiple views (MultiView Forwarding), the i.S.Sy.Da.T.A. iterative segmentation algorithm, and (2) nonlocal means (NLM) conditioning (filtering) for the experimental XCT data. This results in good segmentation Dice scores across all phases compared to more standard approaches (i.e., standard UNet architecture, single view slicing, standard single training, and NLM conditioning). Herein, the NLM filter is replaced with the deep conditioning framework BAM SynthCOND introduced in a previous publication, which can be trained with synthetic XCT data. This leads to a significant segmentation precision increase for all phases. The proposed methods are potentially applicable to other materials and imaging techniques.
Large temperature gradients inherent to additive manufacturing (AM) processes induce large residual stress (RS) in the final part. Because RS can influence the tribological properties, this study focuses on the relationship between wear sliding properties and RS in IN718 coatings. Such coatings were deposited with a Laser metal deposition (LMD) machine using two different scanning strategies.
The wear resistance and RS state were investigated after surface milling. RS were measured before and after wear tests on a reciprocating sliding test apparatus.
Two different X-ray diffraction techniques were employed to measure the surface and subsurface state RS: Laboratory Energy Dispersive X-ray Diffraction (LEDXD) and Synchrotron X-ray Energy Dispersive Diffraction (SXEDD). Due to the milling process, the coatings show similar depth distributions of RS from 22 to 92 μm depth, but exhibit different magnitudes depending on the scanning strategy used. Reciprocating sliding wear tests induced high compressive residual stresses that erased the initial RS state, and a similar wear behavior was observed in the two samples. These samples possess similar texture and grain morphology. This demonstrates that the influence of RS on wear resistance is a second-order effect. Nevertheless, it was observed that RS can still impact the wear performance at the early testing stages of the repaired parts.
The BAMline at the synchrotron X-ray source BESSY II (Berlin, Germany) is supporting researchers especially in materials science. As a non-destructive characterization method, synchrotron X-ray imaging, especially tomography with hard X-Rays, plays an important role in structural 3D characterization. The imaging capabilities allow for in-situ and operando experiments. In this presentation the data handling pipeline is presented.
The BAMline at the synchrotron X-ray source BESSY II (Berlin, Germany) is supporting researchers especially in materials science. As a non-destructive characterization method, synchrotron X-ray imaging, especially tomography with hard X-Rays, plays an important role in structural 3D characterization. The imaging capabilities allow for in-situ and operando experiments. In this presentation the equipment, data handling pipeline as well as various examples from material science are presented.
The lack of traceability to meter of X-ray Computed Tomography (CT) measurements still hinders a more extensive acceptance of CT in coordinate metrology and industry. To ensure traceable, reliable, and accurate measurements, the determination of the task-specific measurement uncertainty is necessary. The German guideline VDI/VDE 2630 part 2.1 describes a procedure to determine the measurement uncertainty for CT experimentally by conducting several repeated measurements with a calibrated test specimen. However, this experimental procedure is cost and effort intensive. Therefore, the simulation of dimensional measurement tasks conducted with X-ray computed tomography can close these drawbacks. Additionally, recent developments towards a resource and cost-efficient production (“smart factory”) motivate the need for a corresponding numerical model of a CT system (“digital twin”) as well. As there is no standardized procedure to determine the measurement uncertainty of a CT system by simulation at the moment, the project series CTSimU was initiated, aiming at this gap. Concretely, the goal is the development of a procedure to determine the measurement uncertainty numerically by radiographic simulation. The first project (2019-2022), "Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU" developed a framework to qualify a radiographic simulation software concerning the correct simulation of physical laws and functionalities. The most important outcome was a draft for a new guideline VDI/VDE 2630 part 2.2, which is currently under discussion in the VDI/VDE committee. The follow-up project CTSimU2 "Realistic Simulation of real CT systems with a basic-qualified Simulation Software" will deal with building and characterizing a digital replica of a specific real-world CT system. The two main targets of this project will be a toolbox including methods and procedures to configure a realistic CT system simulation and to develop tests to check if this replica is sufficient enough. The result will be a draft for a follow-up VDI/VDE guideline proposing standardized procedures to determine a CT system's corresponding characteristics and test the simulation (copy) of a real-world CT system which we call a "digital twin".
The project series CTSimU was initiated with the goal to develop a set of procedures to enable the determination of the task-specific measurement uncertainty of a CT system numerically by radiographic simulation. The first project (2019-2022) “Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU” was focused on the sufficient physical correctness of the radiographic simulation and created as a result a test framework for simulation softwares and a draft of a VDI standard in the series VDI/VDE 2630 for this application. However, for the realistic simulation of a CT system in a simulation software (i.e. a digital twin), not only the correctness of the simulation software itself is crucial, but also the quality of the parameterization of the CT system in the simulation software - this represents the starting point of the 2nd project “Realistic Simulation of real CT systems with a basic-qualified Simulation Software - CTSimU2” (2022-2024).
The parameterization of a CT system in a simulation software can be divided into four steps: after the data acquisition at the real CT system (step 1) follows the evaluation of the acquired data for the generation of general parameter specifications (step 2). It follows the transfer of the parameters into the specific simulation software (step 3) and the validation of the resulting simulation parameters by a suitable test (step 4). The intended result of the project CTSimU2 is a draft VDI standard (for VDI/VDE 2630) for this test, which contains an informative annex on the state of the art regarding the possibilities for parameter determination.
Die Entwicklung von Werkzeugen zur realitätsnahen Nachbildung eines industriellen CT-Systems in einer Simulationssoftware ist derzeit Hauptaufgabe des WIPANO Forschungsprojektes CTSimU2 Realistische Simulation realer Röntgencomputertomografie - Systeme mit basisqualifizierter Simulationssoftware. Als Voraussetzung dienen dabei Simulationssoftwares, die durch das Testframework aus dem Vorprojekt CTSimU1 basisqualifiziert wurden. Das Testframework testet die hinreichende physikalische Korrektheit und Funktionalität einer Simulationssoftware (Basisqualifizierung der Software). Für eine realitätsnahe Nachbildung ist nicht nur die Güte der Simulationssoftware, sondern insbesondere die Güte der Parametrisierung des realen CT-Systems in der Simulationssoftware ausschlaggebend. Dabei kann das Vorgehen der Parametrisierung in vier Schritte unterteilt werden: die Datenaufnahme am realen CT-System (Schritt 1), die Auswertung der aufgenommenen Daten für die Generierung allgemeiner Parameterangaben (Schritt 2), die Übertragung der Parameter in die spezifischen Simulationssoftwares (Schritt 3) und die Validierung der resultierenden Simulationsparameter durch einen geeigneten Test (Schritt 4). Ziel des Projektes ist es daher neben der Erarbeitung eines Werkzeugkastens mit allgemeinen Methoden zur Datenaufnahme und Auswertung der Daten, die Entwicklung eines Tests, auf dessen Basis die ausreichend korrekte Simulation einer realen Anlage beurteilt werden kann. Die erarbeiteten Ergebnisse sollen wie bereits im Vorprojekt CTSimU1 in einen Richtlinienentwurf für die Richtlinienreihe VDI/VDE 2630 übertragen werden. Dieser Beitrag soll einen Überblick über das Projekt und die ersten Ergebnisse geben.
Virtual CT with aRTist
(2023)
The software aRTist is a simulation tool for the generation of realistic radiographs of virtual radiographic superstructures.
With radiographic simulations, virtual component models can be scanned as in a computer tomograph.
Industrial X-ray computed tomography (CT) enables the non-destructive detection of internal and external surfaces as well as inhomogeneities of technical objects. Virtual CT offers new possibilities for the investigation of parameter influences of this complex testing and measuring technique. In addition to the option of switching physical effects on and off, scanning movements can also be tested before their technical realization.
The virtual CT generates projection images from different directions for the subsequent reconstruction of a volume model of the examined object. The reconstruction of the simulated scans is carried out with the algorithms and programs for real scans. Tomographic scans consist of a large number of projections, which practically cannot be generated individually by the user of a simulation. The software offers various options for the automated simulation of tomographic scans. These range from standard CT to scans on free trajectories or with individual projection matrices.
Structural alloys are largely employed in key industrial sectors and their demand is predicted to rise rapidly for the next decades. Most of these materials require a large amount of energy for extraction and manufacturing, which causes the emission of greenhouse gases and other pollutants. Therefore, strategies for improving the sustainability of structural metallic alloys are urgently needed.
Additive Manufacturing (AM), in particular Laser Powder Bed Fusion (PBF-LB/M), aims to be a sustainable manufacturing process, as it allows the build-up of complex geometry in near net-shape from 3D models, while minimizing material waste and the energy required for the process and post-process treatments.
Nevertheless, the application of additively manufactured parts in structural safety-relevant applications is still hindered by the poor fatigue performance. The cause of this has been mainly attributed to the presence of manufacturing defects and surface roughness. Therefore, a huge effort has been made to optimize the process parameters and to introduce post-process treatments to minimize the defect content. However, material flaws cannot be fully eliminated, but these can be considered in a damage tolerance framework for the prediction of the fatigue performance of additively manufactured metallic materials, which is essential for part design and qualification.
This work aims at presenting different modelling strategies for the prediction of the fatigue limit of AM metals. Simple empirical models and more complex models based on fatigue short crack propagation are proposed. The investigated material is an AlSi10Mg alloy fabricated by PBF-LB/M and subjected to two different low-temperature heat-treatments (265°C for 1 h and 300°C for 2h). The results show that the models can provide good approximation of the fatigue limits and help in the interpretation of the scatter of fatigue data.