8.5 Röntgenbildgebung
Filtern
Erscheinungsjahr
- 2023 (5) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (2)
- Vortrag (2)
- Posterpräsentation (1)
Sprache
- Englisch (5)
Schlagworte
- Computer Tomography (2)
- Lithium Ion Batteries (2)
- Tomography (2)
- Copper Deposition (1)
- Deep Discharge (1)
- Li-ion battery (1)
- Lithium ion battery (1)
- Lithium-ion battery (1)
- Litium Ion Cells (1)
- MRI (1)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (5) (entfernen)
Eingeladener Vortrag
- nein (2)
AbstractLithium‐ion cells connected in series are prone to an electrical safety risk called overdischarge. This paper presents a comprehensive investigation of the overdischarge phenomenon in lithium‐ion cells using operando nondestructive imaging. The study focuses on understanding the behavior of copper dissolution and deposition during overdischarge, which can lead to irreversible capacity loss and internal short‐circuits. By utilizing synchrotron X‐ray computed tomography (SXCT), the concentration of dissolved and deposited copper per surface area is quantified as a function of depth of discharge, confirming previous findings. The results also highlight for the first time a nonuniform distribution pattern for copper deposition on the cathode. This research provides insights for safer battery cell design.
Due to their increasing energy density, lithium-ion-batteries (LIBs) play a key role in the traffic energy transition. Regarding their safety behavior, the main challenge of LIB-cells remains the thermal runaway (TR) process. In situ/operando investigations of the TR on commercial cells is possible with radiographic and computer tomographic measurements. Nonetheless, high resolution visualization of the TR persists as a challenge due to the high progression speed of the TR-process itself. Generally, performing abuse tests at cryogenic temperatures allows to slow down or even prevent the TR. Nevertheless, not all abuse methods are suitable for TR investigations at low temperatures. Nail penetration is an appropriate option, however, contains numerous unknown parameters and therefore suffers regarding reproducibility.
Herein, a self-developed high precision nail-penetration-setup is introduced, approaching the necessary mechanically reproducibility with controlled temperatures down to -190°C. The setup allows the preparation of critically abused, however, at cryogenic temperatures stable LIB-cells. These cells were controlled rethermalized to room temperature during synchrotron x-ray computer tomography (SXCT) with a pixel size up to 0.7 μm. During this measurement, the temperature and voltage of the cell is monitored allowing the visualization of the initial internal cell reactions. This study reveals the relation between internal reactions and cell voltage. Finally, the developed set-up enables in-depth analysis of thermal runaway behavior down to material level for various commercial battery cells in the future.
The BAMline at the synchrotron X-ray source BESSY II (Berlin, Germany) is supporting researchers especially in materials science. As a non-destructive characterization method, synchrotron X-ray imaging, especially tomography with hard X-Rays, plays an important role in structural 3D characterization. The imaging capabilities allow for in-situ and operando experiments. In this presentation the equipment, data handling pipeline as well as various examples from material science are presented.
The development of more powerful and more efficient lithium-ion batteries (LIBs) is a key area in battery research, aiming to support the ever-increasing demand for energy storage systems. To better understand the causes and mechanisms of degradation, and thus the diminishing cycling performance and lifetime often observed in LIBs, in operando techniques are essential, because battery chemistry can be monitored non-invasively, in real time. Moreover, there is increasing interest in developing new battery chemistries. Beyond LIBs, sodium ion batteries (NIBs) have gained increasing interest in recent years, as they are a promising candidate to complement LIBs, owing to their improved sustainability and lower cost, while still maintaining high energy density.[1] Initial phases of NIB commercialisation have occurred in the past year. However, for the widespread commercialisation of NIBs, there are still challenges that need to be overcome in developing optimized electrode materials and electrolytes. For the development of such materials and greater understanding of sodium storage mechanisms, solid electrolyte interface (SEI) formation and stability, and degradation processes, in operando methodologies are crucial.
Among the techniques available for in operando analysis, nuclear magnetic resonance spectroscopy (NMR) and imaging (MRI) are becoming increasingly used to characterize the chemical composition of battery materials, study the growth and distribution of dendrites, and investigate battery storage and degradation mechanisms. In situ and in operando 1H, 7Li and 23Na NMR and MRI have recently been used to study LIBs and NIBs, identifying chemical changes in Li and Na species respectively, in metallic, quasimetallic and electrolytic environment as well as directly and indirectly studying dendrite formation in both systems.[2-4] The ability of NMR and MRI to probe battery systems across multiple environments can further be complemented by the enhanced spatial resolution of micro-computed X-ray tomography (μ-CT) which can provide insight into battery material microstructure and defect distribution.
Here, we report in operando 1H and 7Li NMR and MRI experiments that investigate LIB performance, and the identification of changes in the Li signal during charge cycling, as well as the observation of signals in both 1H and 7Li NMR spectra that we attribute to diminishing battery performance, capacity loss and degradation. Additionally, recent operando methodology are adapted and implemented to study Sn based anodes in NIBs. 23Na spectroscopy is performed to monitor the formation and evolution of peaks assigned to stages of Na insertion into Sn, while 1H MRI is used to indirectly visualize the volume expansion of Sn anodes during charge cycling. Battery operation and degradation is further explored in these NIBs, using μ-CT, where the anode is directly visualized to a higher resolution and the loss of electrolyte in the cell, during cycling is observed
Adopting X-ray computed tomography (XCT) for ex-situ characterization of battery materials has gained interest in the past decade. The main goal of this paper is to demonstrate the effectiveness of several X-ray computer tomography techniques to study commercial batteries. General guidelines are provided to select the most suitable imaging equipment and parameters for investigations of lithium-ion batteries, spanning the length scales from cell to electrode, down to particle level. Relevantly, such parameters would also be suitable for operando experiments.
Safety mechanisms and manufacturing inconsistencies at cell level as well as defects and inhomogeneity in cathode and anode is illustrated and quantified. Furthermore, relation of beam energy and sample-detector-distance on contrast retrieved from attenuation and phase shift is inspected using Synchrotron XCT.