8.5 Röntgenbildgebung
Filtern
Erscheinungsjahr
- 2021 (93) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (38)
- Vortrag (33)
- Posterpräsentation (12)
- Beitrag zu einem Tagungsband (7)
- Dissertation (2)
- Forschungsbericht (1)
Schlagworte
- Additive manufacturing (19)
- Computed tomography (12)
- Residual stress (11)
- Laser powder bed fusion (10)
- Additive Manufacturing (7)
- Residual Stress (7)
- AGIL (5)
- Tomography (5)
- Microcracking (4)
- Neutron diffraction (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (93)
- 8.5 Röntgenbildgebung (93)
- 9 Komponentensicherheit (21)
- 9.4 Integrität von Schweißverbindungen (18)
- 5 Werkstofftechnik (12)
- 5.1 Mikrostruktur Design und Degradation (8)
- 9.6 Additive Fertigung metallischer Komponenten (7)
- 8.0 Abteilungsleitung und andere (6)
- 5.2 Metallische Hochtemperaturwerkstoffe (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (3)
Eingeladener Vortrag
- nein (33)
Performance of calcium phosphate cements in the augmentation of sheep vertebrae - An ex vivo study
(2021)
Oil-based calcium phosphate cement (Paste-CPC) shows not only prolonged shelf life and injection times, but also improved cohesion and reproducibility during application, while retaining the advantages of fast setting, mechanical strength, and biocompatibility. In addition, poly(L-lactideco-glycolide) (PLGA) fiber reinforcement may decrease the risk for local extrusion. Bone defects (diameter 5 mm; depth 15 mm) generated ex vivo in lumbar (L) spines of female Merino sheep (2–4 years) were augmented using: (i) water-based CPC with 10% PLGA fiber reinforcement (L3); (ii) Paste-CPC (L4); or (iii) clinically established polymethylmethacrylate (PMMA) bone cement (L5). Untouched (L1) and empty vertebrae (L2) served as controls. Cement performance was analyzed using micro-computed tomography, histology, and biomechanical testing. Extrusion was comparable for Paste-CPC(-PLGA) and PMMA, but significantly lower for CPC + PLGA. Compressive strength and Young’s modulus were similar for Paste-CPC and PMMA, but significantly higher compared to those for empty defects and/or CPC + PLGA. Expectedly, all experimental groups showed significantly or numerically lower compressive strength and Young’s modulus than those of untouched controls. Ready-to-use Paste-CPC demonstrates a performance similar to that of PMMA, but improved biomechanics compared to those of water-based CPC + PLGA, expanding the therapeutic arsenal for bone defects. O, significantly lower extrusion of CPC + PLGA fibers into adjacent lumbar spongiosa may help to reduce the risk of local extrusion in spinal surgery.
Analyse des gefügeabhängigen Löslichkeitsverhaltens potenziell AKR-empfindlicher Gesteinskörnungen
(2021)
Das gefügeabhängige Löslichkeitsverhalten wurde an folgenden vier Gesteinskörnungen unterschiedlicher Alkaliempfindlichkeitsklassen
untersucht:
• GK1 (EIII-S): quarzreicher Kies
• GK2 (EIII-S): Grauwacke (Splitt)
• GK3 (EI-S): Quarz-Feldspat-Porphyr (Splitt)
• GK4 (EI-S): sandsteinreicher Kies
DiePorenstrukturanalyse erfolgte sowohl an Einzelkörnern mittels vergleichender 3D-CT und BET- Untersuchungen als auch an Korngemengen der einzelnen Kornfraktionen (außer Fraktion 16/22 mm) über die Wasseraufnahme und mit BET. Für die Visualisierung und Quantifizierung der von außen zugänglichen Oberflächenanteile der Einzelkörner wurde ein Softwaretool entwickelt, erprobt und erfolgreich angewandt. Es gelang so u.a. den Nachweis zu erbringen, dass die gebrochenen Einzelkörner der Grauwacke und des Rhyoliths einen deutlich geringeren von außen zugänglichen Oberflächenanteil als die gleichartigen Gesteinskörner aus dem Kies besitzen. Aufgrund der limitierten Ortsauflösung der 3D-CT von 11 bis 16,5 μm wurde mit BET eine um drei Zehnerpotenzen höhere spezifische Oberfläche ermittelt.
Zu den Porositätsuntersuchungen an den Korngemengen sei angemerkt, dass zum Teil gegenläufige Trends zwischen offener Porosität und spezifischer Oberfläche festgestellt wurden. Dieses ist beim Bezug des bei den Löseversuchen in 0,1 M KOH mit definierter NaCl-Zugabe aus der Gesteinskörnung gelösten SiO2 und Al2O3 von zentraler Bedeutung. Bei den Löseversuchen an den fraktionsspezifischen Korngemengen selbst zeigte sich, dass die stufenweise Erhöhung des NaCl-Gehalts von 0 auf 10 M.-% im Eluat eine erhöhte SiO2-Löslichkeit und eine verminderte Auslaugung von Al2O3 zur Folge hat. Auffallend war hierbei, dass die Al2O3-Löslichkeit bei GK4 ohne und mit geringer NaCl-Zugabe die mit Abstand höchsten Werte annimmt. Bei den zusätzlich durchgeführten Löseversuchen an den tomografierten Einzelkörnern in 1 M KOH-Lösung mit Zugabe von 1 M.-% NaCl zeigte sich, dass nur vereinzelt bei den untersuchten Gesteinsarten eine Korrelation zwischen dem SiO2- bzw. Al2O3-Gehalt im Eluat und der absoluten BET-Oberfläche nachweisbar ist. Dies ist vermutlich darauf zurückzuführen, dass neben der Oberfläche weitere Parameter (z.B. die mineralogische Zusammensetzung der Einzelkörner) das Löseverhalten maßgebend beeinflussen. Bei den parallel zu den Löseversuchen durchgeführten Betonversuchen nach dem ARS 04/2013 zeigte sich, dass die Alkaliempfindlichkeit der GK4 bei beiden Betonversuchen mit Alkalizufuhr unterschiedlich zu bewerten ist. So ist unabhängig von der vorgegebenen pessimalen Betonrezeptur des Fahrbahndeckenbetons ausschließlich bei der Klimawechsellagerung die GK4 als alkaliempfindlich einzustufen. Allerdings konnte der Befund der stark ausgeprägten AKR bei der GK4 mit der Dünnschliffmikroskopie nicht bestätigt werden. Analoges gilt für die Bewertung der Alkaliempfindlichkeit von GK2 mit den Betonversuchen nach der Alkalirichtlichtlinie des DAfStb. So ist auch hier die GK2 nicht im 60 °C-Betonversuch sondern ausschließlich im 40 °C-Betonversuch als alkaliempfindlich einzustufen.
Dienach den verschiedenartigen Betonversuchen durchgeführten LIBS-Analysen am Vertikalschnitt der Prüfkörper zeigen, dass im Kernbereich nach dem 60 °C-Betonversuch mit 10 %iger NaCl-Lösung und nach der Klimawechsellagerung mit NaCl-Beaufschlagung annähernd gleich hohe Natrium- und Chloridgehalte vorgefunden werden. Wider Erwarten treten an den beaufschlagten Prüfflächen Abreicherungen von Natrium und Anreicherungen von Chlorid auf. Im 40°C- und 60 °C-Betonversuch wurde das Natrium bis in eine maximale Tiefe von ca. 30 mm bzw. 20 mm ausgelaugt. Die aufbauenden korrelativen Betrachtungen zwischen den Ergebnissen des 60°C Betonversuchs mit Alkalizufuhr und der Löseversuche an den fraktionsspezifischen Korngemengen in 1 M KOH-Lösung mit definierter NaCl-Zugabe sind durchaus vielversprechend. So zeigt sich beispielsweise beim Waschbeton, dass der fraktionsspezifisch gewichtete SiO2-Überschuss im Eluat nach 56 Tagen mit Zugabe von 0,5 M.-% NaCl ohne Bezug auf die BET-Oberfläche zur gleichen Einstufung der vier betrachteten Gesteinskörnungen wie bei den Dehnungen im 60 °C-Betonversuch mit 3 %-iger NaCl-Lösung führt. Außerdem korrelieren die im 60 °C-Betonversuch mit 10 %-iger NaCl-Lösung ermittelten Dehnungen mit dem gewichteten SiO2-Überschuss im Eluat bei Zugabe von 2 M.-% NaCl ohne Bezug auf die BET-Oberfläche.
Ausschließlich bei den Betonversuchen nach der Alkali-Richtlinie erwies sich der Bezug des im Eluat ermittelten SiO2-Überschusses auf die BET-Oberfläche als zielführend. Aufgrund des Potenzials der Löseversuche mit NaCl-Zugabe für die Bewertung der Alkaliempfindlichkeit der Gesteinskörnung im Fahrbahndeckenbeton wird empfohlen, die vergleichenden Untersuchungen zwischen den Löseversuchen an Korngemischen der einzelnen Fraktionen und den Betonversuchen nach dem ARS 04/2013 mit einer möglichst hohen Anzahl an Gesteinskörnungen und einem präzisierten Untersuchungsumfang fortzuführen.
Additive manufacturing technologies provide unique possibilities in the production of topologically optimized, near-net shape components. The main limiting factors affecting the structural integrity of Laser Powder Bed Fusion (LPBF) parts are manufacturing defects and residual stress (RS) because both of them are virtually inevitable. Taking into account the complex thermal history of LPBF materials, a prediction of the material behavior is not possible without experimental data on the microstructure, defect distribution, and RS fields. Therefore, this thesis aims to understand the factors that influence the LPBF Ti-6Al-4V material performance the most, covering both the production and the post-processing steps of manufacturing.
Indeed, a parametric study on the influence of manufacturing process and post-processing on RS, defects and microstructure was performed. It was found that the volumetric energy Density (EV), commonly used for the LPBF process optimization, does neither consider the pore shapes and distribution, nor the influence of individual parameters on the volume fraction of pores.
Therefore, it was recommended not to use EV without great care. It was shown that the Position on the base plate has a great impact on the amount of RS in the part.
The micromechanical behavior of LPBF Ti-6Al-4V was also studied using in-situ Synchrotron X-ray diffraction during tensile and compression tests. Diffraction elastic constants (DEC), connecting macroscopic stress and (micro) strain, of the LPBF Ti-6Al-4V showed a difference
from the DEC of conventionally manufactured alloy. This fact was attributed to the peculiar microstructure and crystallographic texture. It was therefore recommended to determine experimentally DECs whenever possible.
Low Cycle Fatigue (LCF) tests at a chosen operating temperature were performed to evaluate the effect of post-treatment on the mechanical performance. Through the information on the microstructure, the mesostructure, and the RS, the LCF behavior was (indirectly) correlated to the process parameters. It was found that the fatigue performance of LPBF samples subjected to hot isostatic pressing is similar to that of hot-formed Ti-6Al-4V. The tensile RS found at the
surface of LPBF as-built samples decreased the fatigue life compared to the heat-treated samples. The modification of the microstructure (by heat treatment) did not affect the Fatigue performance in the elastic regime. This shows that in the absence of tensile RS, the manufacturing defects solely control the failure of LPBF components and densification has the strongest effect on the improvement of the mechanical performance.
Laser powder bed fusion (LPBF) is an additive manufacturing process for materials which inherently tends to yield various degrees of metastable hierarchical microstructures, defects and high residual stresses in the as-built condition depending on the process parameters. The understanding of the evolution of these typical features during heat treatment and subsequent thermal and mechanical ageing is crucial for the wider acceptance for safety critical structures. A multi-disciplinary research project at BAM studying the development of the microstructure, defects, residual stresses typical of LPBF 316L and their evolution during thermal and mechanical ageing has led to insights into the stability of these inherent features. This presentation aims to give a broad overview of the project with a few specific cases of investigation. Firstly, the formation of residual stresses, the nature of the initial microstructure, the tensile properties and a modelling approach to understand the anisotropy will be presented. This will be followed by examples of studies of their evolution during heat treatment, long term thermal exposure, and room temperature and high temperature mechanical testing compared to a baseline of conventional wrought variant of the same alloy.
Additive manufacturing (AM) technologies are experiencing an exceedingly rapid growth, driven by their potential through layer wise deposition for transformational improvements of engineering design, leading to efficiency and performance improvements. Laser Powder Bed Fusion (LPBF) is an Additive Manufacturing (AM) method which permits the fabrication of complex structures that cannot otherwise be produced via conventional subtractive manufacturing methods. Nevertheless, the rapid cooling rates associated with this process results in the formation of significant and complex residual stress (RS) fields. A large body of both experimental and simulation research has been dedicated in recent years to the control and mitigation of RS in AM. In order to validate simulations with the end goal of being able to model the residual stress state in AM components and to devise strategies for their reduction during manufacturing, experimental methods need to be able to accurately determine 3D residual stresses fields in complex geometries. Several destructive and non-destructive methods can be used to analyze the RS state, the choice of which depends on the geometry and the information required. Diffraction-based methods using penetrating neutron and synchrotron X-rays at large scale facilities offer the possibility to non-destructively spatially resolve both surface and bulk residual stresses in complex components and track their changes following applied thermal or mechanical loads. This presentation will overview the success stories of using large scale facilities by the BAM for the characterization of residual stresses in additively manufactured metallic alloys. In particular, the study of the influence of process parameters on the residual stress state and the relaxation of these stresses through heat treatment will be presented. However there remains challenges to overcome particularly of the hypotheses underlying the experimental determination of residual stresses, which will be discussed.
The progress of Advanced Manufacturing, which has been identified by the European Commission as a Key Enabling Technology (KET) for future economic and societal progress is strongly reliant on the development of metrology capabilities. EURAMET, the association of metrology institutes in Europe, has established metrology research programs to address the metrology requirements across a spectrum of different thematic areas. In order to leverage the benefits of these developments on the wider industrial landscape, a high-level coordination of the metrology community supporting the Advanced Manufacturing landscape is required. This coordination is aimed to be achieved by the establishment of European Metrology Networks (EMNs), which are intended by EURAMET to provide a sustainable structure for stakeholder engagement and support. The joint networking project 19NET01 AdvManuNet funded by EMPIR for 4 years, started in June 2020 and aims to accelerate the process of establishing an EMN to strengthen Europe’s position in Advanced Manufacturing. The AdvManuNet project aims to support the establishment of an EMN on Advanced Manufacturing via the following specific aims:
1. Creation of a single hub for stakeholder engagement across the landscape of various industrial sectors including relevant societies and standardization bodies.
2. Development of a Strategic Research Agenda (SRA) and roadmaps for Advanced Manufacturing metrology based on the stakeholder engagement activities, considering current gaps in metrological capabilities existing networks and roadmaps.
3. Establish a knowledge-sharing program for Advanced Manufacturing stakeholders, promoting the dissemination and exploitation of the results of the project, including those from previous EU funded research projects.
4. Development of a sustainable web-based platform and service desk for Advanced Manufacturing stakeholders to allow for easy access to European metrology capabilities and support the wider advanced manufacturing community with metrology-based requirements.
5. Develop a plan for a coordinated and sustainable European metrology infrastructure for Advanced Manufacturing via a European Metrology Network.
The project concept followed by the scope and definition of Advanced Manufacturing will be described. The analysis of the current capability of metrology for Advanced Manufacturing and the preliminary concepts for the strategic research agenda will be presented with a focus on dimensional metrology.
Advanced Manufacturing and Advanced Materials have been identified by the European Commission as one of six Key Enabling Technologies (KETs), the full exploitation of which will create advanced and sustainable economies. Metrology is a key enabler for progress of these KETs. EURAMET, which is the association of metrology institutes in Europe, has addressed the vital importance of Metrology for these KETs through the support for the creation of a European Metrology Network for Advanced Manufacturing. The EMN for Advanced Manufacturing (AdvanceManu) was approved in June 2021 and held the formal kick-of meeting in October 2022. The EMN comprises both National Metrology Institutes (NMIs) from across Europe and other designated Institutes (Dis). The EMN is organized in three sections; Advanced Materials, Smart Manufacturing Systems and Manufactured components and products. The aim of the EMN is to engage with stakeholders in the field of Advanced Manufacturing and Advanced Materials (Large & SMEs, industry organisations, existing networks and academia) with the aim to prepare a Strategic Research Agenda (SRA) for Metrology for Advanced Manufacturing. In the shorter term, an orientation paper is aimed to be produce to in the context of the European Partnership for Metrology. In addition to the SRA, the EMN will establish knowledge and technology transfer and promotion plan. This includes leveraging the existing research results from the completed and running EMPIR JRP projects funded through EURAMET.
This presentation will outline the EMN for Advanced Manufacturing, describing the structures and goals, the route to the production of the SRA and the progress made to date identifying the key metrology challenges across the related Key Industrial Sectors (KICs). In particular, the presentation aims to inform the community on how to be involved in the shaping of the strategic research agenda for the future of Metrology for Advanced Manufacturing and Advanced Materials.
Introduction to AGIL
(2021)
Nowadays, teeth are not directly extracted when tooth decay occurs. Whenever treatment of the affected tooth is possible, the carious region is replaced with a suitable filling. The filling material differs according to the position and size of the cavity. Since the restoration will remain in the tooth for many years, a well adhering and sealing interface between filling and healthy tooth tissue is needed. There is continuous development of new materials, but intensive studies of this complex interface between filling and healthy tooth are still lacking. Little is known about possible diffusion of elements from dental materials into healthy tooth tissue forming a socalled interzone with specific chemical and structural properties.
The combination of different analytical X-ray methods at synchrotron radiation facilities and in the laboratory enables an extensive structural and elemental investigation of such interzones. While X-ray fluorescence techniques and X-ray absorption spectroscopy yield elemental distributions and localized chemical speciation, X-ray diffraction, refraction and computed tomography add structural information to the full 3D analysis of model and real life tooth
samples. Within two DFG funded projects, we develop adapted methodologies and investigate
micro-chemical changes in interzones which we hypothesize may lead to sclerotic dentine.
Within the DFG project ‘IXdent’, first results have been achieved on 2D µXRF and X-ray refraction radiography measurements as well as combined 3D confocal µXRF and µXCT investigations at the interface between filling and bovine tooth tissue. The benefit of multiple analytical techniques and the combination of structural and elemental analysis will be demonstrated.