8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Filtern
Dokumenttyp
- Vortrag (187)
- Zeitschriftenartikel (111)
- Beitrag zu einem Tagungsband (87)
- Posterpräsentation (64)
- Buchkapitel (10)
- Sonstiges (9)
- Forschungsdatensatz (8)
- Forschungsbericht (4)
- Beitrag zu einem Sammelband (3)
- Dissertation (2)
Sprache
- Englisch (358)
- Deutsch (127)
- Mehrsprachig (1)
Schlagworte
- Concrete (102)
- Ultrasound (87)
- LIBS (63)
- Monitoring (53)
- Non-destructive testing (39)
- Beton (29)
- Zerstörungsfreie Prüfung (29)
- Ultraschall (28)
- NDT (26)
- Coda wave interferometry (21)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (486) (entfernen)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (187)
Nach 1850 wurde zur weiteren Herabsetzung der Einbrenntemperatur von Glasmalfarben Borax (Na2B4O7 · 10 H2O) zugesetzt. Das Verhältnis war nun 1 Teil SiO2, 3 Teile PbO und 0,5 Teile Borax. Der analytische Nachweis von Bor in eingebrannten Malschichten war bisher jedoch nicht möglich.
In Laborversuchen wurden Glasmalfarben mit unterschiedlichem Gehalt an Borax auf Modellgläser aufgetragen, eingebrannt und anschließend unter simulierten Umweltbedingungen zeitraffend im Klimaschrank bewittert. Mit Hilfe von elektronenmikroskopischen Untersuchungen können Malschichten charakterisiert werden und somit Hinweise auf mögliche Schadensursachen liefern. Der Nachweis von Bor erfolgte mit Hilfe von LIBS-Messungen (Laser Induced Breakdown Spectroscopy) an im Labor hergestellten Glasmalfarben mit unterschiedlichem Boraxgehalt.
Nach 1850 wurde zur weiteren Herabsetzung der Einbrenntemperatur von Glasmalfarben Borax (Na2B4O7 · 10 H2O) zugesetzt. Das Verhältnis war nun 1 Teil SiO2, 3 Teile PbO und 0,5 Teile Borax. Der analytische Nachweis von Bor in eingebrannten Malschichten war bisher jedoch nicht möglich.Daher wurden in Laborversuchen Glasmalfarben mit unterschiedlichem Gehalt an Borax auf Modellgläser aufgetragen, eingebrannt und anschließend unter simulierten Umweltbedingungen zeitraffend im Klimaschrank bewittert.
Mit Hilfe von elektronenmikroskopischen Untersuchungen können Malschichten charakterisiert werden und somit Hinweise auf mögliche Schadensursachen liefern. Erste Versuche zum Nachweis von Bor erfolgten mit Hilfe von LIBS-Messungen (Laser Induced Breakdown Spectroscopy) an im Labor hergestellten Glasmalfarben mit unterschiedlichem Boraxgehalt.
Feuchtemessverfahren
(2018)
The detection of delamination, rot, and cracks in wooden construction elements is a key task for nondestructive testing (NDT). Air-coupled ultrasound (ACU) is used to detect defects and damage without altering the structure permanently. Using through transmission it is possible to detect even small holes and missing adhesive. After interpretation of the inspection data, an assessment of the mechanical properties based on an appraisal of internal defects in the material is feasible. Novel ferroelectret transducers with a high signal-to-noise ratio (SNR) enable a high-precision structure recognition. The transducers made of cellular polypropylene (PP) are quite suitable for ACU testing due to their extremely low Young’s modulus and low density which result in a favorable acoustic impedance for the transmission of ultrasonic waves between the transducer and air. Thus, structures with great dimensions, thickness up to 300 mm and material densities under 500 kg/m³ can be inspected. Promising results were obtained under laboratory conditions with frequencies from 90 kHz to 200 kHz. The advantage of ACU transducers is that they do not require contact to the sample, are accurate, and cost effective. Ultrasonic quality assurance for wood is an important attempt to increase the acceptance of wooden structures and towards sustainability in civil engineering in general.
Ultrasound echo is a widely used NDT technique for determining the internal geometry of structures. Reverse-time migration (RTM) has been recently introduced to NDT applications, as an imaging method for ultrasound data, to overcome some of the limitations (e.g. imaging steeply dipping reflector) experienced by the Synthetic Aperture Focusing Technique (SAFT), the most commonly used imaging algorithm for these measurements.
The standard implementation of RTM also experiences some drawbacks caused by its imaging condition, which is based on the zero-lag of the cross-correlation between source and receiver wavefields and generates high-amplitude low-frequency artifacts. Three alternative imaging conditions, developed for seismic data applications, were tested for their ability to provide better images than the standard cross-correlation: illumination compensation, deconvolution and wavefield decomposition. A polyamide specimen was chosen for the simulation of a synthetic experiment and for real data acquisition. The migrations of both synthetic and real data were performed with the software Madagascar. The illumination imaging condition was able to reduce the low-frequency noise and had a good performance in terms of computing time. The deconvolution improved the resolution in the synthetic tests, but did not showed such benefit for the real experiments. Finally, as for the wavefield decomposition, although it presented some advantages in terms of attenuating the low-frequency noise and some unwanted reflections, it was not able to image the internal structure of the polyamide as well as the cross-correlation did. Suggestions on how to improve the cost-effectiveness of the implementation of the deconvolution and wavefield decomposition were presented, as well as possible investigations that could be carried out in the future, in order to obtain better results with those two imaging conditions.
Advanced ultrasonic imaging for concrete: Alternative imaging conditions for reverse time migration
(2018)
Ultrasound echo is a widely used NDT technique for determining the internal geometry of structures. Reverse-time migration (RTM) has been recently introduced to NDT applications, as an imaging method for ultrasound data, to overcome some of the limitations (e.g. imaging steeply dipping reflector) experienced by the Synthetic Aperture Focusing Technique (SAFT), the most commonly used imaging algorithm for these measurements.
The standard implementation of RTM also experiences some drawbacks caused by its imaging condition, which is based on the zero-lag of the cross-correlation between source and receiver wavefields and generates high-amplitude low-frequency artifacts. Three alternative imaging conditions, developed for seismic data applications, were tested for their ability to provide better images than the standard cross-correlation: illumination compensation, deconvolution and wavefield decomposition. A polyamide specimen was chosen for the simulation of a synthetic experiment and for real data acquisition. The migrations of both synthetic and real data were performed with the software Madagascar. The illumination imaging condition was able to reduce the low-frequency noise and had a good performance in terms of computing time. The deconvolution improved the resolution in the synthetic tests, but did not showed such benefit for the real experiments. Finally, as for the wavefield decomposition, although it presented some advantages in terms of attenuating the low-frequency noise and some unwanted reflections, it was not able to image the internal structure of the polyamide as well as the cross-correlation did. Suggestions on how to improve the cost-effectiveness of the implementation of the deconvolution and wavefield decomposition were presented, as well as possible investigations that could be carried out in the future, in order to obtain better results with those two imaging conditions.
Informationen zu in Betonbauteilen stattfindenden Umlagerungsprozessen sowie Druckspannungsverteilungen können mit konventioneller Messtechnik bislang nicht zweifelsfrei beantwortet werden. Ultraschallmessungen mit eingebetteten Sensoren könnten hier eine sinnvolle Ergänzung zur konventionellen Messtechnik sein. Durch Einsatz der Codawelleninterferometrie (CWI) sind hiermit schon sehr kleine Änderungen im Material detektierbar.
Um diese neue Methodik zu evaluieren, wurde das Forschungsprojekt „Querkrafttragfähigkeit von Spannbetonbrücken – Erfassung von Spannungszuständen in den Spannbetonversuchsträgern mit Ultraschallsensoren“ durch die Bundesanstalt für Straßenwesen (BASt) initiiert. In diesem Projekt wurden durch die Bundesanstalt für Materialforschung und –prüfung (BAM) Ultraschall-Transducer in mehrere Spannbetonträger des Instituts für Massivbau der RWTH Aachen eingebettet, die anschließend bis zum Bruch belastet wurden.
Der Belastungsversuch an einem der Spannbetondurchlaufträger zeigte das große Potential dieser Methodik. Die im Netzwerk erfassten Änderungen der Ultraschallwellengeschwindigkeit geben die Spannungsverhältnisse im Längsschnitt des Trägers schon bei sehr niedrigen Belastungen qualitativ richtig wieder und zeigen bei hohen Belastungen eine gute Korrelation zum Rissbild. Dabei weisen räumliche Anomalien und Änderungen in der Charakteristik der Geschwindigkeitsänderungen oft schon auf Rissbildung hin, wenn diese noch nicht an der Oberfläche sichtbar ist. Dies zeigt das Potential im Hinblick auf eine Frühwarnung. Hierfür und ebenso in Bezug auf eine Quantifizierung der Effekte ist aber noch Entwicklungsarbeit notwendig. Ein Vorteil der Methodik ist, dass die Transducer nicht direkt am Ort der Änderung platziert werden müssen und einen relativ großen Bereich um die Transducer herum erfassen.
Informationen zu in Betonbauteilen stattfindenden Umlagerungsprozessen sowie Druckspannungsverteilungen können mit konventioneller Messtechnik bislang nicht zweifelsfrei beantwortet werden. Ultraschallmessungen mit eingebetteten Sensoren könnten hier eine sinnvolle Ergänzung zur konventionellen Messtechnik sein. Durch Einsatz der Codawelleninterferometrie (CWI) sind hiermit schon sehr kleine Änderungen im Material detektierbar.
Um diese neue Methodik zu evaluieren, wurde das Forschungsprojekt „Querkrafttragfähigkeit von Spannbetonbrücken – Erfassung von Spannungszuständen in den Spannbetonversuchsträgern mit Ultraschallsensoren“ durch die Bundesanstalt für Straßenwesen (BASt) initiiert. In diesem Projekt wurden durch die Bundesanstalt für Materialforschung und –prüfung (BAM) Ultraschall-Transducer in mehrere Spannbetonträger des Instituts für Massivbau der RWTH Aachen eingebettet, die anschließend bis zum Bruch belastet wurden.
Der Belastungsversuch an einem der Spannbetondurchlaufträger zeigte das große Potential dieser Methodik. Die im Netzwerk erfassten Änderungen der Ultraschallwellengeschwindigkeit geben die Spannungsverhältnisse im Längsschnitt des Trägers schon bei sehr niedrigen Belastungen qualitativ richtig wieder und zeigen bei hohen Belastungen eine gute Korrelation zum Rissbild. Dabei weisen räumliche Anomalien und Änderungen in der Charakteristik der Geschwindigkeitsänderungen oft schon auf Rissbildung hin, wenn diese noch nicht an der Oberfläche sichtbar ist. Dies zeigt das Potential im Hinblick auf eine Frühwarnung. Hierfür und ebenso in Bezug auf eine Quantifizierung der Effekte ist aber noch Entwicklungsarbeit notwendig. Ein Vorteil der Methodik ist, dass die Transducer nicht direkt am Ort der Änderung platziert werden müssen und einen relativ großen Bereich um die Transducer herum erfassen.
Four cement-based and four calcium-sulphate-based screed types are investigated. The samples have a diameter of 300 mm and a height of 35 or 70 mm. Up to ten humidity sensors are embedded directly during the concreting of the screed samples. Thus, the humidity over the sample height is monitored during hardening, hydration, evaporation, and oven drying. Furthermore, the screed samples are weighted during every measurement to determine the total mass and the corresponding moisture loss.
To define the pore system precisely, mercury intrusion porosimetry as well as gas adsorption is performed. According to the data, the entire pore volume distribution is known. The measured pore diameters range from 0.8 nm to 100 μm and the total porosity of the examined screeds ranges between 11 % and 22 %.
Based on these measurement data, moisture transport, pore saturation as well as sorption isotherms and their hysteresis may be calculated quantitatively as described by Strangfeld et al.